| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.9 L+₹2.1 L (9.80%)Rejected-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹25.1 L+₹3.3 L (14.9%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹25.5 L+₹3.7 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹27.6 L+₹5.8 L (26.7%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
₹26.9 L
EMD Value
₹53,900
Closing Date
25 Jan 2021, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
SPECIAL REPAIRS FOR REPLACEMENT OF SPLIT ACs, REFRIGERATORS AND WATER COOLERS AGAINST BER UNDER GE(NORTH) SECUNDERABAD
2020_MES_407445_1
CWE(S)/NORTH/TOKEN-29 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE(North) Secunderabad
₹53,900
Yes
12 Mar 2021
28 Dec 2020
28 Jan 2021
28 Dec 2020
25 Jan 2021
12 Jan 2021
Amount
Supply, fix, testing and commissioning of Inverter type hi wall split AC units indoor / outdoor with copper condenser complete with cordless remote control unit duly charged with non-CFC / eco-friendly refrigerant gas and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and capacity of 1.5 TR including necessary PVC drain pipe upto a length of 15m, concealed brick / stone wall / floor by cutting chases and making good, finishing to match the surrounding, copper tubing, standard angle iron frame work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. Notes:- (a) The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed by Engineer-in-Charge. Make : BlueStar, Daikin , Hitachi, Voltas, Carrier
Supply, fix, testing and commissioning of Inverter type hi wall split AC units indoor / outdoor with copper condenser complete with cordless remote control unit duly charged with non-CFC / eco-friendly refrigerant gas and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating capacity of 2.0 TR including necessary PVC drain pipe upto a length of 15m, concealed brick / stone wall / floor by cutting chases and making good, finishing to match the surrounding, copper tubing, standard angle iron frame work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. Notes:- (a) The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed by Engineer-in-Charge. Make : BlueStar, Daikin , Hitachi, Voltas, Carrier
Supply, fix, testing and commissioning of window type air conditioner electric driven (single phase), cooling capacity of 1.5 Ton with copper condenser with 5 star rating, complete with cordless remote control unit duly charged with non-CFC / eco-friendly refrigerant gas concealed brick / stone wall / floor by cutting chases and making good, finishing to match the surrounding, standard angle iron frame if necessary, work mounting arrangement including painting with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. Notes:- (a) The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. (b) The contractor shall make necessary opening on the brick / stone wall for installing the window AC and packing the extra openings around the window AC unit all as directed by Engineer-in-Charge. Make : BlueStar, Daikin , Hitachi, Voltas, Carrier
Supply and fix refrigerator, Double Door, electric driven (single phase), capacity of 284 ltrs or more, With Copper Condensor all as specified and as directed. Note:- The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Make: Samsung, Whirlpool, LG or Godrej
Supply and fix refrigerator, Double Door, electric driven (single phase), capacity of 308 ltrs or more, With Copper Condensor all as specified and as directed. Note:- The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Make: Samsung, Whirlpool, LG, Godrej
Supply, installation, commissioning of water cooler fully Stainless Steel body with Two Faucets, electric driven (single phase), having approx storage capacity of 80 ltrs and nominal cooling capacity of 40 ltrs per hour (40/80 Ltrs ) complete all as specified and directed. Note:- The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Make : BuleStar, Usha, Voltas
Supply, installation, commissioning of water cooler fully Stainless Steel body with Three Faucets, electric driven single phase having approximate storage capacity of 150 ltrs and nominal cooling capacity of 150 litres per hour complete all as specified and as directed. Notes:- The contractor shall furnish the manufacturer's warranty card to the Engineer-in-Charge after satisfactory commissioning of the units. Make : BuleStar, Usha, Voltas
omsai thermax engineers
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
K LAKSHMAN SINGH AND CO
SREE KIRAN ENGINEERS
Srinivash Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .