| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹39.4 L+₹18,036 (0.46%)Rejected-AOC PLOT NO 76 CIV SOCIETY MUKUND NAGAR AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹39.5 L+₹25,084 (0.64%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹41.2 L+₹2.0 L (4.99%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹42.9 L+₹3.7 L (9.37%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
29 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (05) in the area of AGE B/R I under GE (N) Ahmednagar
2021_MES_473778_1
8565 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹85,000
Yes
14 Oct 2021
9 Sept 2021
1 Oct 2021
9 Sept 2021
29 Sept 2021
24 Sept 2021
60 days
Amount
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortor ,wall tiling etc complete all as specified and directed by Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed by Engineer-in-Charge
Demolition of plain cement concrete (unreinforced) in ground floor not exceeding 15 cm thick etc complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames nexc 1.5 Sq m with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
Taking down shutter exceeding 1.00 Sqm but not exc 2 Sqm etc complete all as specified and directed by Engineer-in-Charge
Taking down steel windows/ventilator n exc 1.5 Sqm,any size with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge
Taking down steel tubing and connections,15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 8 but 20mm bore.
M & L for 75 mm thick plain cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge
M & L for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment and applying 10mm thick cement plaster in cement and sand mortar (1:4). Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished rainforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, area of toilet/bathroom exc 1.50 Sqm but nexc 5.00 Sqm etc after dismantling the existing sunken floor etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair pressed steel frames of size 125mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc incl filling in door frames in plain cement concrete, 1:2:4 type B0, using 12.5 mm graded. etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 35 mm thick factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial plywood. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated etc complete all as specified and directed by Engineer-in-Charge
Supply and fix 35 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge
Supply and fix solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, the shutter shall be fixed with and including stainless steel hinges 100mm size etc complete all as specified and directed by Engineer-in-Charge
S&F steel ventilator with top hung double shutter with side hung shutters i.e. glazed shutter from outside & gauged shutter inside incl hinges with steel handles and steel peg stay complete with guard bar and glazing bars dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge
S&F mild steel barrel tower bolt 200mm long , stove enamelled black, with bright bolt etc complete all as specified and directed by Engineer-in-Charge
S&F mild steel sliding door bolts 300mm long , plate type stove enamelled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed by Engineer-in-Charge
S&F for mild steel pressed handles 150mm long , oval type , stove enamelled black etc complete all as specified and directed by Engineer-in-Charge
S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and directed by Engineer-in-Charge
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix aluminium anodised barrel tower bolt of extruded section 200mm long etc complete all as specified and directed by Engineer-in-Charge
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge
M & L for 18mm thick block boards, grade 1 quality, exterior grade, decorative type with decorative face veneer on one face fixed with screws to timber frame-work etc complete all as specified and directed by Engineer-in-Charge
S&F continuous (piano) hinges, mild steel bright finish or electro galvanised width of flaps (when open) 30 mm etc complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness size,quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads etc complete all as specified and directed by Engineer-in-Charge
M & L for 3mm thich figured glass pin headed type glazing with oil putty, bead in squares n.exc 0.50 Sqm Each as per item above etc complete all as specified and directed by Engineer-in-Charge
M & L for glazing with 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in Each pane etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair wire cloth 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples etc complete all as specified and directed by Engineer-in-Charge
M & L for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed & pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge
M & L for coloured glazed ceramic tiles of size exc 0.06 Sqm and n'exc 0.18 Sqm , 8-10 mm thick as approved by GE as in dado/skirting or on vertical surfaces, over and including 10 mm thick backing coat in cement and sand mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M & L for 60-62mm thick, PCC pavers interlocking tiles glossy finish, any shape & size conforming to IS 15658 of 2006. M-35 grade made up with 12.5mm graded mechanically crushed stone aggregates, factory made over and including 30mm thick sand cushioning and joints filled with fine sand incl levelling & sweeping etc complete all as specified and directed by Engineer-in-Charge
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick, area of tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of floor etc complete all as specified and directed by Engineer-in-Charge
All as per item No 34 (here-in-before) but as in skirting over & including screed, 10mm thick in cement and sand mortar (1:4)
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of Each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor over and including 15 mm thick screed bedding in cement and sand mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed by Engineer-in-Charge
M & L 16-18mm thick pre-polished granite stone slab of approved shade and colour Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills etc or on vertical surfaces including vertical projection, full round moulding the edge laid over screed bed 15mm thick in cement and sand mortar (1:4) jointing , pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite and rubbing polish to achieve mirror finish etc complete all as specified and directed by Engineer-in-Charge
S&F of kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 15mm thick screed in cement and sand mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for machine cut cudappah stone slab 18-20 mm , laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M & L for rendering, 10 mm thick on ceiling surfaces in cement and sand mortar (1:4) surfaces finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 10mm thick in cement and sand mortar (1:6) on brick or concrete surface/ stone surfaces finishing even and smooth with thin layer of sagol finish etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15 mm thick in cement and sand mortar (1:6) on other than fair surfaces of wall finished even & smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
Dismantling of water tanks from any position/location, of any make etc,of capacity exc 500 Ltr & n.exc 1000Ltr with ball valve, etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs tubular towel rail, brass chromium plated 20 mm dia `D' type, 60 cm long between flanges including a pair of brackets etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No U-0911 of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs vitreous China white squatting pan, Orissa pattern of size 580 X 440 mm width with integral foot rest set in cement concrete including flush pipe and connecting to trap / flushing cistren etc complete all as specified and directed by Engineer-in-Charge. Make :- Cat Part No C0117 Of Parryware or Cat Part No 20042 of Hindware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs wash hand basin vitreous China, flat back of size 550 X 400 mm including a pair of brackets, PTMT waste coupling, 32 mm dia PVC flexible waste pipe and connecting to stop valve and nahani trap etc complete all as directed. Make : Cat Part No 10004 of Hindware or Cat Part No C0475 of Parryware or equivalent in makes imentioned in list of makes in Appendix `C'
Supply and fix mild Steel 32 mm dia CP curtain rods with fixing brackets fixed in repairs etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs stainless steel kitchen sink matt finish without draining bowl size 410 X 410 X 230 mm, made out of 1.00 mm thick SS sheet of high quality including a pair of brackets, waste coupling, plug and chain, 32 mm dia PVC flexible waste pipe and nahani trap etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs bib tap, 15 mm dia, CP cast copper alloy with crutch or butterfly handle screwed down for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge. Make:- Cat part No MOR 1020 A(Oriental series) of MARC or equivalent make as mentioned in list of make in Appendix `C'
Supply and fix in repair stop valve, 15 mm dia, cast copper alloy,screwed down high pressure screwed down high pressure with cruitch or butterfly handle screwed both ends for iron pipe or for unions all as directed. Make:- Cat part No MOR 1320 (Orintal series) of MARC or equivalent in in makes mentioned in list of makes in Appendix `C'
Supply and fix 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as directed.Make:- Cat part No MOR 1010(Orintal series) of MARC or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs, shower rose with shower arm etc complete all as specified and directed by Engineer-in-Charge Make:- Cat part No MARC MSR1050 (Shower) and MOR 1260(Shower arm) or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs rotational moulded polyethylene water storage tanks double layer ISI marked (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to irin pipe and connecting etc complete all as specified and directed by Engineer-in-Charge
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed all as specified and as approved by GE/Engineer-in-Charge.
S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 15/20mm dia bore pipe etc complete all as specified and directed by Engineer-in-Charge
Supply and fix repairs PVC valveless, syphonic action type, flushing cistern,low level, all accesories all as directed. Make :- Sleek essence series of Hindware or Cat part No E8303 of Parryware or equivalent in makes mentioned in list of makes in Appendix `C'
Supply and fixing in repairs 15 mm bore galvanised steel tubing medium grade laid in trenches or fixed to walls / ceiling etc complete all as specified and directed by Engineer-in-Charge
All as per items ser No 58 9here-in-before) but 20mm bore.
Supply and fix in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs, grating 100 mm dia of PTMT etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs looking mirror of size 600 mm X450 mm all as directed. Make:- Cat part No C 8606 Of Parryware or equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repairs 75mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with stack clamps FI 50mm by 5mm flat iron clamps to walls incl bolt & nuts etc complete all as specified and directed by Engineer-in-Charge
All as per item No 63 (here-in-before) but 110 mm dia
Supply and fix in repairs PVC (SWR) bends any radius, for 75mm bore of pipe with access door etc complete all as specified and directed by Engineer-in-Charge
All as per item No 65 (here-in-before) but 110 mm dia
S&F 110 mm bore PVC (SWR) branch piece double (single/double Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
S&F 75mm bore PVC (SWR) branch piece double (single/double Y) equal or unequal etc complete all as specified and directed by Engineer-in-Charge
M&L for Preparing unplastered or plastered surfaces of walls and applying two coats of oil bound distemper including 2mm thik wall care putty including smooth roller finish etc complete all as specified and directed by Engineer-in-Charge
M&L for applying two coats of cement paint on newly / old plastered surfaces including preparation surface walls etc complete all as specified and directed by Engineer-in-Charge
M&L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description exc 10 cm width or girth including preparation of surfaces and smooth finish with roller etc complete all as specified and directed by Engineer-in-Charge
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly / untreated steel surfaces of any description exc 10 cm width or girth including preparation of surfaces etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly / old plastered surface and applying 3 coats of white wash on wall etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new / old plastered surface and applying 3 coats of white wash on ceiling etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old wooden surface and applying one coat of synthetic enamel paint over etc complete all as specified and directed by Engineer-in-Charge
M & L for TMT bars 8 to 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not les than 0.90 mm dia etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair nahani trap with 100 mm dia grating incl 75mm dia PVC bend for fixing with drain pipe and repair to floor tiles on broken area n.exc 1.00 sqm area in kitchen or bathroom etc complete all as specified and directed by Engineer-in-Charge
S&F for 32mm dia low density polyethylene pipe (HDPE) of presure rating 6 kg/cm2 fixed complete to wall, ceilings or in floors etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for foundation etc or for walls, shafts, manholes laying of pipe, cable not exc 10 Sqm on plan and getting out, in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Excavation in trenches exc 1.5m wide and not exc 3m in depth for foundation etc or for walls, shafts, manholes not exc 10 Sqm on plan and getting out, in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Blank
Demolition of reinforced cement concrete of any description and in any position not otherwise provided for including reinforced cut as required to facilitate demolition etc complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete (un-reinforced) blocks/RR walling built in cement mortar including coping etc ,of any description in any position etc complete all as specified and directed by Engineer-in-Charge
Demolition and breaking up 200 mm bore drain pipe i.e. salt glazed ware, AC or reinforced concrete pipe , set in cement mortar etc complete all as specified and directed by Engineer-in-Charge
All as per item No 84 (here-in-before) but 300mm bore pipe
All as per item No 84 (here-in-before) but 450mm bore pipe
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cm thick each etc complete all as specified and directed by Engineer-in-Charge
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point in soils etc complete all as specified and directed by Engineer-in-Charge
Material & labour for 200 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional complete all as specified and dircted by Engineer-in-Charge . Note :- (i) Cutting into existing sewer line/manhole shall be measured & paid seperately. (ii) Excavation & earth work shall be measured and paid separetely once either while demolition or while laying pipe.
All as per item No 89 (here-in-before) but 300 mm
All as per Item 89 (here-in-before) but 450 mm bore pipe
Material and labour for reinforced cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as cover slab for drain or manhole including necessary form work and making holes 25 mm dia @ 150 mm centre to centre, set and jointed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:3:6) type C-1 using 20mm graded mechanically crushed stone aggregates as in cills, steps, bands, copings, bed plates, kerbs, hold fasts blocks etc including weathering slightly rounded or chamfered angles of throating including form work etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:3:6) type C-1 using 20 mm graded mechanically crushed stone aggregates as in surface channel & drain etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregates as in foundation, filling and mass concrete or similar works etc complete all as specified and directed by Engineer-in-Charge
M&L brick work with sewer bricks straight or curved on plan exc 6m mean radius for manholes/ Septic tank/soak well etc in built in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
Material & Labour for rendering 10 mm thick in cement and sand mortar (1:4) on concrete or brick surfaces of wall finished even & smooth without using extra cement mixed with water proof compound @ 3 % of the weight of cement as per the manufecturer's instructions etc complete all as specified and directed by Engineer-in-Charge Note :- WPC shall be measured and paid separetely.
Supply only integral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
Cutting into existing manholes for connecting new drains 200mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooh finished and reforming benching as required all as specified.
Cutting into existing manholes for connecting new drains 150mm internal dia of pipe making good to pipe abd rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooh finished and reforming benching as required all as specified.
Supply and fix PVC (SWR) cowl for bore of pipe 75 mm etc complete all as specified and directed by Engineer-in-Charge
Supply and fix PVC (SWR) floor trap 75mm dia plain with PVC grating including jointing with solvent cement etc complete all as specified and directed by Engineer-in-Charge
M&L for cleaning blockage of manholes circular size 1.5 mtr dia (inner) and square size 1200 x 900mm , depth n.exc 1.5 m, incl getting out snd removal of undissolved materials, debries, sewage sludge, plastic, thermocoal, gunney bags, etc accumulated at sewage line using sewage non clog pumps of sutable rating and deposited to a distance exc 500 mtrs from the starting point all as specified and directed.
Material and labour for cleaning of sewer line, of any depth, of any location, manhole of any depth, section, size between the sewer lines sewer line to septic tank/soak well/sump well by means of sewage sucking machine or by way of any other suitable means including disludging foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge/material out side MD land by any means/source keeping the sewage line functional for the 150 & 200 mm bore pipe lines complete all as specified and as directed
Taking down/out the covers from septic tanks/soakage well and dewatering the contaminated/waste material from septic tank/soak well/sump well of any liquid depth/capacity by means of using mechanical pumps diesel driven with fuel or by operator sewage sucking machine or by way of any other suitable means including disludging foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge mixed material/liquid out side MD land by any means/source and refixing the covers back to its original position etc complete all as specified and directed by Engineer-in-Charge Note : Solid contents of waste material will be measure and paid.
Supplying and fixing precast manhole cover (LD) of size 18" x 36" made up of steel fiber reinforced concrete M-30 grade as per IS etc complete all as specified and directed by Engr-in-Charge
All as per above item but of size 18" x 18"
All as per above item but of size 36" x 36"
Surface dressing n. exc 15 cm deep and removal of wild groth / shurps, roots, incl spraying of deweding chemical 1 m each side on both sides along sewage line etc complete all as specified and directed by Engineer-in-Charge
M&L for Moorum/red bajri filling as in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed by Engineer-in-Charge
M&L for Filleting in any position and to any shape in cement and sand mortar (1:4) including all mitres, stops, (exc 25 sqcm but n'exc 50 sqcmetc.
Material & labour for 150 mm bore Reinforced cement concrete pipe, type NP2 , haunching against the sides of pipe in PCC 1:4:8 type D-2 using 40mm graded mechanically crushed stone aggregates and making necessary connection after cutting into existing sewer line/manhole to make it functional etc complete all as specified and directed by Engineer-in-Charge
Supply and fixing Pre cast RCC Hume Pipe septic tank of capacity 25 User and necessary excavation in any type of soil etc complete all as specified and directed by Engineer-in-Charge
M&L for Brick work with fly ash bricks straight or curved on plan exc 6m mean radius and built in cement and samd mortar (1:6), etc complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick plaster on any faces of brick work or concrete surfaces to be finished even and smooth (without using extra lime or cement in cement and sand mortar (1:4) etc complete all as specified and directed by Engineer-in-Charge
M&L for loose filling with aggregates of gauge 80 to 150mm in soakage pits, soakage wells etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories PVC boxes (upto 12 module suitble for Mylinc series of Legrand including white plates with frame upto 12 module of make suitable for Mylinc Series ) for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2.Wiring shall be done as per complaints recd from user only on required basis it is not necessary to do whole wiring of any whole bldg 3. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, ceiling lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One bell point controlled by one switch 5 Amp single pole, one way on independent board
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
One light point controlled by switch 5 Amp single pole two way
All as per Item No 118 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase , Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
S&F bell Multi music type elelctric 230V AC single pole etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 6 Amp, one way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 6 Amp, two way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Switch, 16 Amp, onw way, one Module. etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Socket Outlet 6 Amp, 2/3 pin, combined two module etc complete all as specified and directed by Engineer-in-Charge.
S&F Modular Socket Outlet 6 Amp / 16 Amp - 2/3 pin combined two module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Bell push, 6 Amp, one module etc complete all as specified and directed by Engineer-in-Charge
S&F Modular Fan Regulator Fan step regulator, 120 Watt - two module etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts ,protection class IP-42, suitable for fixing of MCBs etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent makes mentioned in list of makes in Appendix `C'
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs,, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, TPN, AC, 415 volts of 63 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 2.5 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 2.5 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable10 Sqmm, 4 core.
Supply &lay HDPE pipe 40 mm bore light weight with 0.95 gm/cm2 IS: 4984(1995) PN 2.5 for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Taking out/down and opening of existing ceiling fans 1200 mm sweep,from any position, of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by thouroghly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistance including repair /replacement of spare parts/ material /items , making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 Sqmm upto 0.50 Mtr length including using material/parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional complete all as specified and as directed.
Material and labour for preperation of ceiling fans 1200 mm sweep, of any make by cleaning of metal surfaces including painting with spray painting on required gloss with white synthetic enamel paint on complete body of fans and writing MES No with black synthetic enamel paint etc complete all as specified and directed by Engineer-in-Charge
S & F water heater (Geyser) storage type PVC body rating 5 Star, suitable to operate on AC 230 volts, electric driven of capacity 25 Ltrs including PVC connection 2 number, CP angle cock 15 mm, 02 number etc complete all as specified & directed by Engineer-in-Charge.
An amount of Rs 67,147.00 shall be deducted from BOQ on account of schedule of credit
HG PATHAN CONSTRUCTION COMPANY
M/S. M. F. Sharif & Co.
M/S. Z.K.ENTERPRISES, AHMEDNAGAR
M/s Meher Construction
Neha Enterprises
Ms. M.D. Auty
Priyadeep Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .