| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.8 LAccepted-Finance | ₹51.8 L | L1 | Accepted-Finance Overall lowest basis |
| 2 | L2₹57.9 L+₹6.1 L (11.8%)Rejected-Finance | ₹57.9 L+₹6.1 L (11.8%) | L2 | Rejected-Finance Overall L2 |
| 3 | L3₹63.0 L+₹11.2 L (21.5%)Rejected-Finance | ₹63.0 L+₹11.2 L (21.5%) | L3 | Rejected-Finance Overall L3 |
| 4 | L4₹1.2 Cr+₹64.8 L (125.0%)Rejected-Finance B 13 2ND FLOOR SUBHASH CHOWK VIKAS MARG LAXMI NAGAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | ₹1.2 Cr+₹64.8 L (125.0%) | L4 | Rejected-Finance Overall L4 |
Tender Value
₹59.4 L
EMD Value
₹1 L
Closing Date
6 Aug 2024, 10:00 amClosed
DGM M AND C
NFL PANIPAT
Repair of Anticorrosive Treatment of Different Plant Inside Factory Area
2024_NFL_202363_1
NFL/PT/CIVIL/811R
Open Tender
Civil Works
Works
304 days
NATIONAL FERTILIZERS LIMITED GOHANA ROAD PANIPAT
6 documents required · 6 mandatory
₹0
₹1 L
17 Jan 2025
24 Jul 2024
7 Aug 2024
24 Jul 2024
6 Aug 2024
24 Jul 2024
24 Jul 2024 - 5 Aug 2024
Amount
Provinding and Supplying the following materials for Repair ofAnticorrosive treatment at various locations in plant area includingcost of materials, transportation of materials from source of supplyto site of work at NFL Panipat, loading, unloading, octroi, royality,sales tax, excise tax, insurance,or any other tax / expenditure, &everheads for bringing and supplying the materials at site of workcomplete :-
Araldite GY - 250 / B-11
Hardener HY - 830 / K-41
Hardener HY - 840 / K-46
Hardener HY - 850 / K-42
Quartz Sand grade mix No. 10
Epoxy painting with Araldite and Hardners on Concrete / Plastered /Metal surfaces in the All Area of Prilling Tower or any Plant at anyHorizontal / Vertical Locations at all heights and depths with allnecessary useful Tools, scafolding / staging for safe and properexecution of work as per instruction of Engineer-in-Charge.(Payment for cost of Araldite and Hardeners shall be made forseparately vide item No. 1 of Material Part)
A) Araldite GY-250 : Hardner HY - 830 : Hardner HY - 850 =100 PBW : 45 PBW : 15 PBW ( PBW = Parts By Weight)
Two Coat-Ist Coat - Primer-Araldite GY-250 : Hardner HY - 840 =100 PBW : 50 PBW : ( PBW = Parts By Weight)-II nd Coat - Painting -Araldite GY-250 : Hardner HY - 830 : Hardner HY - 850 =100 PBW : 45 PBW : 15 PBW ( PBW = Parts By Weight)
Repairing the damaged concrete / plastered /other surfaces withprimer followed by epoxy Mortar / putty prepared by mixing Araldite,Hardners, Quartz sand, in the areas of Urea Plant, Prill Tower, DMPlant, Bagging Plant or any Plant & at Horizontal / Vertical locationsat all heights and depths with all necessary Useful tools scafolding /staging for safe and proper execution of work as per instruction ofEngineer-in-Charge.(Payment for cost of Araldite, Hardeners and Quartz sand shall bemade for separately vide item No. 1 of Material Part)Araldite GY-250 : Hardner HY - 830 : Hardner HY - 850 :Quartz Sand No. 10100 PBW : 45 PBW :15 PBW : 800 PBW (PBW = Parts By Weight)
Laying 5 mm average thickness ( i.e 3 mm to 7 mm thick) epoxyscreeding with Araldite and Hardners on Concrete / Plastered /surfaces in the areas of DM Plant, or at any other location(s), atHorizontal / Vertical locations at all heights and depths with allnecessary materials ,tools & plants , scafolding /staging, as perenclosed Technical Specifications and special conditions of thecontract and as per following formulations : Primer followerd byScreeding of patches and sealed by seal coat of Epoxy with requiredformulationmade for separately vide item No. 1 of Material Part)Primer Coat :Araldite GY- 250 : Hardner HY - 840 =100 PBW : 50 PBW : (PBW = Parts By Weight)Screeding :Araldite GY-250 : Hardner HY - 830 : Hardner HY - 850 :Quartz Sand No. 10100 PBW : 45 PBW : 15 PBW : 800 PBW ( PBW = Parts By Weight)Final CoatAraldite GY-250 : Hardner HY - 830 : Hardner HY - 850 =Araldite GY-250 : Hardner HY - 830 : Hardner HY - 850 =100 PBW : 45 PBW : 15 PBW ( PBW = Parts By Weight)
Dismantling of existing damaged Epoxy screeding / plaster, oldEpoxy Coating from the Concrete / Plastered / surfaces in thevarious areas of NFL Plant, or at anyother location(s), atHorizontal / Vertical locations at all heights and depths , preparingthe areas to receive fresh treatment, with all necessary tools &tackels , scafolding / staging, including collection of dismentalledmaterials and disposal of the same in disposal yards locatedwithin Factory area as per instruction of Engineer-in-Charge.
Providing and laying Acid Resistant Tile on Floor/Walls/Drains orat any required location in plant area by using 228 mm x 114 mmx 38 mm size Acid Resistant Tile Class-1 conforming to IS: 4860with one priming Coat of epoxy primer with 6 mm or more thickbed of epoxy quartz mortar to make proper slope and painting ofjoints with solvent free epoxy paint as per enclosed technicalspecifications. The rate shall include for surface prepration,dismentailing of existing / damaged floor Providing & Fixing Tilewith mortar and disposal of debris to dump yard in factory area.(Note- All Material for Item no-5 i.e- Acid Resistant Tile, Epoxy Mortar,Quartz Sand and other material etc shall be arrange by Contractor forexecution of said item at is own cost)
Note: (1) GST shall be paid extra as per NIT. (2) Bidders may take care of Clause No. 6.0 of GTC & 1.8.0 of STC while quoting the Rates. (3) Bidders must read all the Clauses of STC and Scope of work before quoting rates.
NAYA RANGOLI PAINTS PRIVATE LIMITED
ZEE TECH
ARIEN NEW DELHI PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .