Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder and reasonable rate quoted | |
| 2 | L2₹27.9 L+₹80,400 (2.97%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.0 L+₹1.9 L (6.98%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹29.7 L+₹2.6 L (9.68%)Rejected-Finance PULGAON | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹30.8 L+₹3.7 L (13.8%)Rejected-Finance BHAWANI KRUPA GANDHI CHOWK PULGAON | PULGAON | WARDHA | MAHARASHTRA | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN-442303
REPAIRS AND REPLACEMENT OF LIGHTENING PROTECTION A B C AT DEPOT AREA UNDER GE PULGAON
2021_MES_436629_1
8887/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE PULGAON
As per NIT
8 documents required · 8 mandatory
₹500
GE PULGAON
₹50,000
Yes
21 Jun 2021
16 Apr 2021
21 May 2021
16 Apr 2021
15 May 2021
30 Apr 2021
16 Apr 2021 - 28 Apr 2021
60 days
Amount
Supply and fixing in repair of air termination single pointed aluminium rod of 12 mm dia and 300 mm long connecting to condutors including taking down existing damaged unserviceable rod all as specified and directed
Supply and fixing in repair of air termination single pointed copper rod of 12 mm dia and 300 mm long connecting to condutors including taking down existing damaged unserviceable rod all as specified and directed.
Supply and fixing in repair of copper strip 20mmx3.15mm with saddles with wooden supports and fixing screw etc for roof conductor and down conductor along the walls including taking down existing damaged unserviceable strip all as specified and directed .
Supply and fixing in repair of aluminium strip 25x3.15mm with saddles with supports and fixing screws etc for roof and down condutor along the walls including taking down existing damaged unserviceable strip all as specified and as directed .
Dismantling and refixing the existing aluminium strip any size after repairing & straightening the same as required with GI saddles with wooden supports and fixing screws etc for roof and down conductor all as specified and as directed .
Dismantling and refixing the existing copper strip any size after repairing & straightening the same as required with GI saddles with wooden supports and fixing screws etc for roof and down conductor all as specified and as directed.
Supply and fix in repair test point terminal block made out of gun metal or phosphorous bronze of size 75 mm x 75 mm x 25 mm, drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screws including taking down existing damaged unserviceable block all as specified and directed .
Supply and fix in repair PVC module SEMC box terminal box of size (100 x 100 mm) to accommodate test terminal block and thickness not less than 1.00 mm including taking down existing damaged unserviceable box complete all as directed. Make: ISI approved
Supply and fixing in repair of GI earth continuity conductor 4mm dia fixed to wall on batten or recess or chases or drawn in conduit/pipe or fix to pole or any other situation for loop earthing etc including taking down existing damaged unserviceable box all as directed.
Taking down existing bent air terminals aluminium rod of any size and refixing the same properly after repairing & straightening with new flat iron 25mmx5mm thick and 40cm long with new nut and bolts, clamps etc fixed/clamped to existing GI pipes/poles complete all as specified and directed .
Taking down existing bent air terminals copper rod of any size and refixing the same properly after repairing and straightening with new flat iron 25mmx5mm thick and 40 cm long with new nut & bolts, clamps etc fixed/clamped to existing GI pipes/poles complete all as specified and directed
Restringing of existing copper ropes of size 18x14 SWG binding to shackle type insulators including fixing clamps with new nut & bolts to roof post all as specified and directed .
Supply and fix in repair shackle type porcelain vitreous, white insulator for working pressure 1100 volts of 90 mm dia and 75 mm height including galvanized mild steel strips of 30mmx3.00mm size 12 mm dia insulator, bolts, washers, nuts etc all as specified and directed .
Supply and fix in repair GI pipe 40 mm bore light grade including bends, sockets etc for earth strip laid in ground/floor, fixed on wall with proper clamping all as specified and directed .
Material and labour for PCC 1:3:6 type C 1 (using 20 mm graded stone aggregate) for making block of size 400x400x200 mm including necessary form work if any for fixing GI pipe/air termination rod all as specified and directed.
Testing of lightening conductor earth resistance by using earth tester in presence of Depot user representative and MES representative and record the reading in user register & MES register respectively and duly countersigned by OC of users & AGE E/M all as specfied and directed . (Note :- (i) Qty of (2x2900) is for testing of lightening conductor for subsequent Half year ending. (ii) Contractor has to submit testing sheet of earthing of each sub depot duly signed by sub depot Cdr/users rep with stamp.)
Material and labour in repair for earthing complete with copper earth plate electrode of size 60cmx60xcmx3.15mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below the normal ground level connected to copper earth strip 20x3mm size as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, protected by GI pipe medium grade 32mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm bore medium grade etc and testing on completion complete all as specified and directed. (Note :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100 mm c/c both ways, funnel with watering pipe 20mm bore medium grade, GI protection pipe medium grade 32mm bore and wire mesh and adequate quantity of charcole and salt complete. Note No 2 :- Rate of copper earthing strip and GI protection pipe up to 7.5 m shall be included in unit quoted of the this item
M&L for earth pit outer size 450mm x 450mm x 450mm in heigth & inner size 300mm x 300mm x 300mm in height with PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate and one number suitable size RCC 1:2:4 type B-1 cover 50mm thick reinforced with 8mm dia TMT bar @ 100 mm c/c both ways including excavation returning filling etc complete all as specified and directed (Note :- Unit rate shall also include for excavation / earthwork in hard/dense soil)
Earthing complete with galvanized steel earth plate electrode of size 60cm X 60 cm X 6 mm buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5 m below the normal ground level connected to GI earth strip 32 X 6 mm dia GI earth lead as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, protected by GI pipe light grade 40mm bore all as shown on electrical plate No 3 of SSR Part-I connected to earth test point electrode, PCC pit with RCC cover, funnel with wire mesh, watering pipe 20mm dia protection pipe etc and testing on completion complete all as specified and directed. (Note No 1 :- The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B-1 cover 50 mm thick reinforced with 8 mm dia TMT bar @ 150 mm c/c both ways, funnel with watering pipe 20 mm dia medium grade, GI protection pipe light grade 40 mm dia and wire mesh and adequate quantity of charcole and salt complete. Note No 2 :- Rate of GI earthing strip and GI protection pipe up to 7.5 m shall be included in unit quoted of the this item
S&F in repair galvanised iron strip 32 x 6mm as earth continuity conductor, beyond earth test point or as ring conductor, fixed to wall on GI saddles or burried in ground or drawn in pipe or any other situation including taking down existing damaged unserviceable strip complete all as specified and as directed.
M/s MM TRADERS
SHRI RANI SATI TRADERS
M/S Maa Durga Constructions,Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES AND ENGG WORKS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
SHUBHAM SALES AND ENGG WORKS
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .