Assistant Engineer / Assistant Engineer (Elect), S
SHQ BSF JAMMU
Replacement of Underground Electric Cable Being Used for BFL On International Border Under Frontier HQ Jammu SH Repair, Maintenance and Replacement of Defective UG Cable in AOR of 36 BN BSF under SHQ BSF Jammu
2022_BSF_683292_2
DIG/Engg/ e-Tender/SHQ/ Jammu/2022-23/4423
Open Tender
Electrical Works
Item Rate
180 days
In AOR of 36 BN BSF under SHQ BSF Jammu.
Please Refer Tender Documents
7 documents required · 7 mandatory
₹0
₹59,619
9 May 2022
11 Apr 2022
25 Apr 2022
11 Apr 2022
23 Apr 2022
11 Apr 2022
11 Apr 2022 - 23 Apr 2022
Amount
Supplying and Laying of one number Aluminum conductor PVC insulated and PVC sheathed armored UG cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC HDPE pipe as required. at a depth upto 75 cm., as required.
3.5 x 25 Sqmm
3.5 x 150 Sqmm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required
63 mm dia (OD-63 mm & ID-51 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following sizes of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3.5 x 25 Sqmm (28 mm)
3.5 x 150 Sqmm (50 mm)
3.5 x 240 Sqmm (62 mm)
SITC of cubical canopy type of Bus bar box made out of 2 mm thick CRCA sheet of size 300 mm x 250 m x 150 mm deep with front openable door having locking arrangement, having IP-55 protection, box have to be fixed on existing Octagonal poles/MS Pole with help of bracket, necessary nut & bolt (of G.I.),with provision of 3.5 core x 25 sq.mm inlet & outlet cable connections with gland, 04 nos aluminium bus bar strip suitable for 32 A,220 V capacity with suitable insulated support for AL bus bar complete as required. (i) Sample of box to be got approved by Department before procurement.
SITC of cubical canopy type out door hut type Junction box having size 450 mm (L) x 300mm (D) x 450mm (H) fabricated with CRCA sheet 2 mm thick mounted on 04 Nos 35mm x 5mm thick angle iron frame, erected in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling,hinged front & back doors with locking arrangements,,cable tray with provision of fixing of glands at hte bottom,antirust design, air ventilation grooves, water drop proofing arrangement ,insluators,earthing studs,nuts bolts etc.as required including connections,painting with primer & finish paint with synthetic enamel paint 04 nos aluminium bus bar strip suitable for 200 A,415 V capacity with suitable insulated support for AL bus bar complete as required.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
Providing and fixing 90 mm dia (6 kg/Sqcm) 1.2 Meter (Approx.) PVC pipe (in Black/Grey color) from ground level to CG Box for cable protection along with 8 meter high GI octagonal pole (having bottom dia 200 mm and top dia 90 mm) / 11 meter high M.S. swaged pole (having bottom dia 205 mm) i/c bends, socket etc. and 1 No. GI clamp of 20 mm x 3 mm GI strip to hold the PVC pipe.
Supply & Fixing of reinforced PVC flexible pipe 30 mm dia (ID) with Puff seal between Existing CG Box & Bus bar box for laying and connection with 1 No. 2.5 sqmm flexible 3 core copper unarmoured cable etc. as required.
Supplying and laying following size PVC pipe (in Black/Grey color) ISI marked complete etc. complete with fitting and cutting, jointing etc. on the existing culvert/fixing on wall with the help of C-clamp, fastner, bends etc. complete as required. (for culvert)
75 mm dia. Pipe for 3.5 x 25sq.mm size cable
110 mm dia. Pipe for 3.5x 150 sq.mm size cable
Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 600 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1000 mm x 1000 mm x 300 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department. Incomer i) MCCB 04 Pole 200 Amp 38-45 Ka , L frame, adjustable thermal and adjustable magnetic setting, Havells/C&S .02 nos with spreader terminals (Both these MCCBs are to be interlocked in such a way that only 01 shall ON at at time.) ii) 3 Phase Digital Ammeter CL-1.0 - 1 No. (Make :- L & T) iii) 3 PhaseDigital Voltmeter CL-1.0 - 1 No. (Make :- L & T) iv) CTs 200/5A, CL-1, 15 VA, Cast Resin for metering - 3 Nos. (Make:- AE ) v) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoings i) MCCB 04 Pole 200 Amp Havells/C&S Fixed type 38-45 Ka breaking cap. = 01 nos with spreader terminals ii) MCCB 04 Pole 100 Amp Havells/C&S Fixed type 26-30 Ka breaking cap. = 02 nos with spreader terminals
Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 600 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1000 mm x 1000 mm x 300 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department. Incomer i) On Load Changeover Switch open execution type 04 Pole 250 Amp Havells/C&S - 02 Nos i) MCCB 04 Pole 250 Amp 38-45 Ka , L frame, adjustable thermal and adjustable magnetic setting, Havells/C&S.02 nos with spreader terminals (Both these MCCBs are to be interlocked in such a way that only 01 shall ON at at time.) ii) 3 Phase Digital Ammeter CL-1.0 - 1 No. (Make :- L & T) iii) 3 PhaseDigital Voltmeter CL-1.0 - 1 No. (Make :- L & T) iv) CTs 200/5A, CL-1, 15 VA, Cast Resin for metering - 3 Nos. (Make:- AE ) v) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoings i) MCCB 04 Pole 200 Amp Havells/C&S Fixed type 38-45 Ka breaking cap. = 02 nos with spreader terminals
Supplying, installation, testing and commissioning of outdoor hut type feeder pillar suitable for 415 V, 3 phase, 4 wire, 50 Hz AC supply system fabricated in compartmentalized design from 2 mm thick CRCA sheet, double door type with inbuilt locking arrangement, 3 mm pasivated gland plate, depth not less than 300 mm and all connection (incoming and outcoming) will be taken out in cable alley. The panel shall be cleaning, processing and finishing with 7 tank process for powder coating in approved shade and supplied with suitable pedestal of 50mm x 50 mm x 6 mm angle iron frame with 600 mm long legs, 200 Amp 4 nos high conductivity aluminium bus bar with DMC/SMC support, earth bus as the same size as the phase bus running across the length of the panel, solid connection from main bus bar to switchgear, control wiring with 1.5 sqmm FRLSH insulated multi stranded copper conductor with cable alley, including providing and fixing following switchgear, fixing LED phase indicator and following accessories etc complete as required. The panel shall be mounted on suitable cement concrete foundation 30 cm below the ground level and 30 cm above the ground level. The panel should not less than 1000 mm x 1000 mm x 300 mm as CPRI approved. Note:- (i) Panel size indicated is nominal. The actual size shall be as per the drawing approved by the Department. Incomer i) MCCB 04 Pole 125 Amp 26-30 Ka , L frame, adjustable thermal and adjustable magnetic setting, Havells/C&S = 02 nos with spreader terminals ii) 3 Phase Digital Ammeter CL-1.0 - 1 No. (Make :- L & T) iii) 3 PhaseDigital Voltmeter CL-1.0 - 1 No. (Make :- L & T) iv) LED Phase Indicating Lamps - 1 Set of 03 Nos. Outgoings i) MCCB 04 Pole 100 Amp Havells/C&S Fixed type 26-30 Ka breaking cap. = 03 nos with spreader terminals
M/s Sharma Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .