Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹44.8 L+₹1.8 L (4.14%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | Rejected-Technical RZ 55 1ST FLOOR MOHAN NAGAR PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Not enlisted in appropriate Cat i e d (i) |
Tender Value
₹42.2 L
EMD Value
₹84,440
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
PROVISION OF WORK STATIONS WITH ALLIED FACILITIES AT CERTAIN OFFICES AT GROUND FLOOR AT AFCAO AT CAMERO COMPLEX
2024_MES_674095_1
GE/SP/TOKEN-42/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹84,440
Yes
17 Dec 2024
12 Sept 2024
14 Oct 2024
12 Sept 2024
11 Oct 2024
27 Sept 2024
Amount
S&F Modular partition workstation with 45mm thick with per-laminated top of 25mm thick as per color approved with metal powder coated legs, . Workstation having glass/fabric/white board prating on the top of the table, with three mobile pedestal, keyboard and CPU trolley. Overall size for per seat 2400x600x1200mm.(two seaters) In each workstation.
S&F Modular partition workstation with 45mm thick with per-laminated top of 25mm thick as per color approved with metal powder coated legs, . Workstation having glass/fabric/white board prating on the top of the table, with three mobile pedestal, keyboard and CPU trolley. Overall size for per seat 1200x600x1200mm.(single seaters) In each workstation.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises and removing the debries outside the MOD land complete all as specified and directed by Engr In Charge.
M&L for vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed by Engr-In-Charge.
All as per Ser item No 4 above but as on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and directed
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land complete all as specified and directed by Engr -in - Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
M&L for preparation of old plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick wall care putty on walls complete all as specified and directed by Engr-In-Charge.
Material and labour for false ceilings using GI snap grid system with rool-formed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board, prepainted cement fibre board size 595x595x4mm thick any texture (Lake, Hill, ocean cascade or Electra ) suspended from RCC roof/ structural members of soofits with angle cleat cut out etc to their equired line and shape as per manufactureres recommndations at any height complete all as specified and as directed by Engr-in-Charge
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling conduit wiring terminated in flush metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 Sq mm cable including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and directed.
All as per item No 13 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site.
S&F switch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed at site.
S&F socket outlet 5 pin 5 Amps all as specified and directed at site.
S&F socket 16 Amps, 2 in 1, flush type all as specified and directed at site.
M & L for submain wiring with two run of single core 10.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling surface and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified . Note : 3 Runs of 10.0 Sqmm single core include PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. Note : 3 Runs of 6.0 Sqmm single core include PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. Note : 3 Runs of 4.0 Sqmm single core include PVC conduit shall be measured as one unit length.
Supply and fixing load line vertical distribution board 'G' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP 'A' frame MCCB of 250 Amps =01 No and MCB for outgoing complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 415V 10KA 'C' curve TPN 16 To 32 AMP miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fix of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 36 KA complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- 1. PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. 2. PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L for earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
shakti construction (BID ID -3136665)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .