Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹28.9 L+₹6,656 (0.23%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹29.5 L+₹66,470 (2.31%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹30.4 L+₹1.6 L (5.40%)Rejected-Finance | L4 | Rejected-Finance Higher | |
| 5 | L5₹32.3 L+₹3.5 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Higher |
Tender Value
₹35.9 L
EMD Value
₹71,800
Closing Date
7 Feb 2022, 6:00 pmClosed
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
SPECIAL REPAIR TO BLDG NO P-63/1 TO 06 (OR MD ACCN) AT JADUNATH ENCLAVE AND OTHER SANCTIONED WORKS UNDER AGE B/R I AT NAMS
2022_MES_500752_1
GE NAMS - 66 / 21 - 22
Open Tender
Civil Works
Item Rate
180 days
NAMS CANTT
Class D
Category a i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹71,800
Yes
19 Feb 2022
11 Jan 2022
8 Feb 2022
11 Jan 2022
7 Feb 2022
24 Jan 2022
Amount
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) nxc 1.50 sqm each all as specified and directed.
Taking down chowkats or frames with shutter’s (without taking off shutter’s from frame) exc 1.50 Sqm & nxc 4.00 Sqm each all as specified and directed.
Taking down shutters of any description exc 1.00 sqm & nexc 2 sqm each complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 12.5 mm graded stone aggregate) as in bed blocks for hold fast and back filling of pressed steel frame etc complete all as specified and directed.
S&F mild steel framed work just as doors, ventilators, and as in hold fast, ladders, railings, Framed Guard bar, railings etc with ends of bars shouldered and/or riveted complete welded hinged and similar work Conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engr-In-Charge.
Material & labour for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter(two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (a) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (b) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (c) MS Tower bolt 150mm long - 2 No per leaf (d) Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (e) Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (f) MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf (g) 8 mm square guard bar, 10 cm centre to centre. (h) 25x4 mm flat iron all around for joint of both frame. (j) Two coat of red oxide primer to MS window and guard bar Note: Including taking down old steel window and making good dismantled portion with PCC 1:2:4 type B0 including hold fast PCC (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-charge.
Material and Labour for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 complete all as specified. (a)10mm Sq Guard bar 10Cm C/C (b)Two coat of red oxide primer to MS window and guard bar Note: Including taking down old steel window and making good dismantled portion with PCC 1:2:4 type B0 including hold fast PCC (four No’s for Each ventilator) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-charge.
Material and Labour glazed skeleton shutter for door 35mm thick 2nd class hard wood(Hollock) open rebated prepapred to receive glass, guage etc ( without sash bars) edges of framing plain, chamfered or rounded,fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I Section 8 Clause 8.24(a) complete all as specified and directed.
S&F 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified.
Supplying and fixing factory made Solid PVC Moulded Door shutter with wood free EPS 28-30mm thick (stiles),with 2 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm Plain colour PVC sheet on back face,supplying & fixing in frame at site as per specification &drawing complete all as specified and directed by Engr-In-Charge. supplying and fixing in the frame at site complete all as specified.
S&F floor door stopper of aluminium alloy body and tongued,anodised,with hard drawn steel spring,fixed complete all as specified and directed.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples.
S & F 150mm aluminum handles, cast type, anodised etc complete all as specified.
S & F 200 mm aluminum anodised barrel tower bolts of extruded sections and fixed complete.
S & F 150 mm aluminum anodised barrel tower bolts of extruded sections and fixed complete.
S & F butt hinges 100 mm size medium weight cold rolled mild steel (zinc chromate coating)complete all as specified and directed.
S&F butt hinges in repair 100mm size medium weight cold rolled mild steel including welding to existing frame and making good complete all as specified and directed.
S&F 250mm mild steel sliding door bolts aluminium alloy anodised, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts,four on bolt plate and two on staple plate and fixed complete all as specified.
S&F 300mm ordinary rat rail rod pattern springs,including roller and roller plate complete all as specified
Supplying and fixing 3mm thick ordinary sheet glass and glazing with oil putty or fixed with wooden beading, in squares not exc 0.50 Sqm in each panes complete all as specified.
Supply and fixing 3mm thick figured glass pin head type and glazing with oil putty in squares not exc 0.50sqm in each pane complete all as specified and dircted.
M & L for two coats of synthetic enamel paint over one coat of primer (Pink Primer) on new wooden surfaces exceeding 10cm width or girth including preparation of surface complete.
M&L for two coats of synthetic enamel paint on new steel surface exc 10 cm width or girth on one coat of primer (Red oxide Zinc crown) incl preparation of old/new surfaces complete.
M&L for two coats of synthetic enamel paint over old steel surface including preparation of old steel surface exc 10 cm width or girth complete all as specified and directed.
Supply and fixing PVC coated curtain rods 25mm dia including, brackets to hold the rod & a set of ABS finials ( as per sample kept in GE's office) of approved quality & appropriate qty of ABS plastic rings complete all as specified .
S&F 20 mm bore dia gate valve,gun metal with iron wheel head,screwed both ends and fixed all as specified and directed.
Supplying and fixing in repairs PVC valve less syphonic action type low level flushing cistern of 10 ltrs capacity with inlet ball valve, float valve, push button type handle including 32mm dia of PVC(Heavy duty) flush pipe including brackets complete all as specified.
S&F in repair rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position 1000 ltr all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position 500 ltr including 20mm dia float valve all as specified and directed.
S&F glass shelf assembly Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
S&F sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass corner shelf with chromium plated bracket guard and railing complete all as specified and directed.
S&F in repair aluminium anodised tubular towel rail,20mm dia,D-type 60 cm long between flanges all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and directed.
M&L for brick work using sub class ‘B’ bricks, straight or corved on plan exc. 6 mean radius in CM 1:6 complete all as specified and directed.
All as per ser item No 35 here in before but except brick
M&L for brick work using sub class ‘B’ bricks, straight or corved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Supply & fixing vitreous china wash down water closet pan (padestal pattern) white with flush pipe for low level flushing cistern including plastic water closet seat white with jet, closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device fixed in repairs complete and directed.
S&F in repair vitreous china squatting pan (orrisa pattern) size 580x440 mm(white) with CI 'P' or 'S' trap, intehral foot rest including trap set include complete concrete & flushing pipe complete all as specified.
Supply and fixing in repair vitreous china wash hand basin(white) flat back of size 550 x 400 mm including bracket, CP waste coupling 32mm, waste pipe, chain, plug and porcelein stopper complete all as specified.
S & F sink made of stainless steel 1mm thick with plug washer and waste coupling, waste pipe including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460mm bowel size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F in repair stainless steel plate Rack of size 750x750x250mm weight not less than 7.5 kg with folded edge gloss finish complete all as specidied and directed.
Taking down G.I tubing 15mm bore including connections & clearing for re-fixing or removal to store.
All as per ser item No 44 above but 20mm bore complete all as specified and directed.
S&F 15mm bore G.I tube medium grade freed to wall or under floor complete including cutting chases and make good in CM 1:3 complete.
All as per ser item No 46 above but 20mm bore complete all as specified and directed.
M&L for PVC connection 45cm long superior quality with PTMT nut on both side .
M&L Intergral Water Proofing compound complete all as specified and directed.
Supply and fixing in repair bib tap long body fancy type 15mm dia chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule
Supplying and fixing in repairs CP wall mixer 3-in-1 system with complete provision and fixing for overhead Shower screwed down high pressure with long screwed both ends for 15mm dia bore GI pipe complete of approved make all as specified and Directed.
S&F in repair 15mm bore stop cock concealed as in repair long shank chromium plated fancy type screwed down high pressure with crutch or butter fly handle.
S&F in repair Angle cock CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed.
Supplying and fixing in repairs 15mm bore centre hole wash basin mixer for wash hand basin cast copper alloy chromium plated screwed down high pressure screwed for iron pipe complete of approved make as per sample all as specified and directed
Supply and fixing in repair 125mm dia , Brass chromium plated , shower rose with swivel joint fixed to GI pipe, complete all as specified.
Supplying and fixing in repairs CP brass towel ring of appropriate size not exc 45cm dia complete all as specified.
Supplying and fixing in repairs toilet paper holder of brass chroimum plated with CP cover plate complete all as specified.
supply and fixing in repair health faucet suitable 15mm dia fixed to GI tubing with CP lead complete all as specified.
Taking down cement plaster from wall’s/ceiling including raking out joints hacking for key scrubbing down with water complete.
M&L for 15mm rendering in cement mortar (1:6) on brick/concrete surfaces finished the surface even and smooth without using extra cement.
M&L for 15mm rendering in cement mortar (1:4) on brick/concrete surfaces finished the surface even and smooth without using extra cement.
M& L for 10mm rendering in cm (1:3) on ceiling surfaces finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of exterior weather coat emulsion over one coat of wall primer complete all as specified and directed by Engr-In-Charge.
M&L for preparation of old plastered surface of walls and applying two coats of exterior weather coat emulsion complete all as specified and directed by Engr-In-Charge.
Material and Labour for preparation of new plastered surfaces and applying two coats of oil bound distemper over coat of primer of chalk whitening on walls complete all as specified and directed by Engr-In-Charge.
Material and Labour for complete removal of existing treatment by wire brushing and washing, rubbing down and stopping of surfaces and applying two coats of oil bound distemper complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces over wall and applying three coats of white wash over new plastered surface over one priming surface complete all as specified and directed.
Material and Labour for preparation of old decorated plastered surfaces and applying two coats of white wash on ceiling complete all as specified.
M&L for applying 2mm thick averaging birla wall care putty over wall/ceiling surface and making surface smooth complete all as specified and directed by Engr-In-Charge.
Supply and fixing light shade vitrified ceramic tiles 10mm thick (square/rectangular)polished, area of each tiles not exceeding 0.36 sqm as in floor,skirting etc set jointed in neat cement slurry and pointed in white/colour cement to match with the colour of tiles over and including15mm thick bedding layer in cement mortar 1:6 including dismantling/roughening of surfaces complete all as specified and directed.
S&F Coloured/printed non skid ceramic tiles 6-7mm thick (Square/rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6 including dismantling/roughening of surface complete all as specified and directed.
M & L for ceramic glazed coloured printed tiles(some portion highlighted with contrast colour) of size 300 x450 x 6-7 mm thick on and incl 10mm thick Rendering in cm (1:4) set and jointed in neat cement slurry and pointed in coloured cement mixed with pigment to match the colour of tiles on vertical surfaces of well as in skirting / dado including dismantling/roughening of surface complete.
M&L 16 to 18 mm thick granite slab as in floor machine cut flooring,skirting,riser etc incl 15mm thick cement mortar 1:6 set and jointed in neat cement slurry and pointed with coloured cement mixed with pigment to match the shade of slab incl cutting rubbing and polishing incl nosing to the edge of granite stone slab including dismantling/roughening of surface complete all as specified and directed by Engr-in-Charge.
M&L for Precast RCC (1:2:4) type B-1 using 20mm graded stone aggregate set in cement mortar 1:6 as in landings,cover slabs for manhole etc,water tank base and similar work complete all as specified and directed including demolition of existing RCC.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Demolition of PCC as in ground floor & Paving n.exc 15cm (Below or above) ground level including disposal of rubbish to a distance nxc 500mtr where directed.
M&L for PCC 1:3:6 type C-2 using 20mm graded stone aggregate as in 50mm thick plinths protection and as in path complete all as specified and directed.
S & F machine pressed factory made precast coloured chequered cement concrete tile 30 cm x 30 cm x 30 mm thk set,jointed & pointed in neat cement slurry with grey cement and pigment in floor including screed bed 20mm thick in CM 1:6 bedded and jointed complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 20mm graded aggregate as in sub base of flooring complete all as specified and directed.
Dismantling cast iron pipe any dia fixed to wall with any type of joints
S&F in repair 100mm cast iron soil, sand cast pipes, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors in repairs.
S&F 100mmdia cast iron bends door diminishing pieces or tapers in repairs.
S&F in repair 100mm cast iron bends diminishing pieces or tapers with oval access oval in repairs.
M&L for 100mm dia cast iron floor trap,with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed.
M&L for repair to RCC Chajjas, roof projection edges ,hanging part of chajjas, edges of chajjas, RCC parapets, under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded agg) incl necessary form work , MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings making edges fair and even and smooth etc completed all as specified and directed by Engr-in-Charge.
S&F for 4mm thick acrylic sheet board of High quality with Media printing of 3m of best quality (size/frame of board, design of bd, type of print on sheet, size of studd, samples of letter, pictures, writing will be provided by accepting officer or Engr-in-Charge) and fixed at any height from GL to 29 Mtr height incl stainless steel studds (min 4 studs at each board / sheet ) complete all as specified and directed incl dismantling of existing damaged sheets. Note : Minimum weight of Acrylic Sheet not less than 4.70kg per sqm (Acrylic sheet make A Cast / Astari / Marka Cipta and stainless steel of grade A-ISI 304(1818).
Supplying and fixing 18mm thick solid PVC board in cup board shelves, shutters etc (in kitchen) complete all as specified and directed of approved make.
All as per Srl Item No. 87 here-in-before but board with one side prelam as in cabinet shutters including piano hinges to fix shutter in length,catcher, 02 Nos per shutter, handle 75mm long stainless steel 01 no per shutter for each shutter complete all as specified and directed of approved make.
Supplying and fixing PVC sheet 5mm thick, in backside of kitchen cabinets complete all as specified and directed of approved make.
M&L for treating perimetre wall or structure from termite mounds using chemical emulsion @2.25 Ltr Per metre including drilling and plugging holes etc in walls/aprons complete all as per direction of Engr-In-Charge. Contractor Should produce guarantee certificate.
S&F in repair CP soap dish fixed with screw to walls complete all as specified.
M&L for green marble 14-16mm thick over cement screed bed laid on 15mm thick CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab/staircase/steps,riser incl rubbing and polishing,moulding rounding to edge of marble & dismantling of existing any type of floor complete all as specified and directed.
M&L for cement concrete type F2 1:5:10 (40mm graded aggregates) as in sunken floor all as specified and directed including demolition of PCC complete all as specified and directed.
M& L for 10mm rendering in cm (1:3) as in sunken portion surfaces including WPC finished the surfaces even and smooth without using extra cement complete all as specified and directed.Note: WPC should be under sepearate item.
S & F in repairs 32mm dia GI pipe in spout of sunken floor all as spesified and directed
Dismantling of brick tiles single layer on roof, jointed and grouted/pointed in cement mortar including cleaning serviceable tiles and stacking properly for reuse, disposal of unserviceable tiles and debries/rubbles from site complete all as specified and directed
M &L for 40 mm thick brick tiles laid on cement mortar 1:6, 15mm thick and jointed grouted, flush in cement mortar (1:3) complete all as specified and directed.
All as per item No.97 above but except tiles.
Demolition of mud in roofs, any thickness including plastering and leaping etc complete all as specified and directed
M & L for PCC (1:3:6) type C1 (20 mm graded stone aggregates) as in roof kerbs, sloping padding in roof slab or mud stops, rounded or chamfered on edges and sunken portion etc.
M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc complete all as specified and directed.
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on roof and sunken portion on bitumen surfaces by forced application complete all as specified.
S&F in repair 100mm cast iron soil,sand cast pipe,wate and vent pipes in any length with or without ears, with cement joints,fixed to walls complete all as specified and directed.
S&F in repair 75mm cast iron soil,sand cast pipes,waste and vent pipes,in any lenth with or without ears with cement jointed,fixed to walls complete all as specified and directed.
S&F in repair 75mm cast iron bends dimnishing pieces or tapers with oval access door in repair all as specified and directed.
S&F cast iron Cowl 75mm bore complete all as specified and directed.
M&L for 18-19mm thick pre-laminated particle board,interior grade,prelaminated one side with decorative choice lamination &other side balancing white lamination,fixed with screws as in kitchen cupboard,almirah etc including magnetic catcher,including external teak wood leaping 6mm thick over particle board and making edge,drilling,making good complete all as specified and directed by Engr-In-Charge.
M&L for continuous piano hinges bright finish electrogalvanised with width of flaps when open 30mm complete all as specified and directed including welding and finishing and making surface clean complete all as specified and directed.
M&L for cement concrete type B-0,1:2:4 using 12.5mm graded stone aggregate as in levelling course in roof finishes even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coat of undiluted thick water based UV resistant elastorneric Polyurethane liquid membrane with UV resistance properties and solar refelctive properties of 109 over one coat of primer (1:3, Dilution:water) Note: Every each coat interval between 6 hrs) ,having solid content more than 80% and elastic recovery @150% elongation %---70 to 75 . complete all as specified and directed.
Taking down shutter of any desctription exc 1.00 sqm but n.exc 2.00 sqm each and refixing in same opening after easing & adjusting including & renewable of unserviceable screws etc complete all as specified and directed.
S & F Pillar tap as in repair, fancy type cast copper alongwith capstan heads, chromium plated, screwed down high pressure , with or without coppered ‘H’ or ‘C’ with long screwed shanks and fly nuts, screwed for iron pipe size 15mm.
Supply and fixing in repair vitreous china wash hand basin(white) wall hung corner type of size 400 x 400 mm including bracket, CP waste coupling 32mm, waste pipe, chain, plug and porcelein stopper complete all as specified.
Material and Labour for preparation of new plastered surfaces and applying two coats of cement base paint on wall complete all as specified.
Material and Labour for complete removal of existing treatment by wire brushing and washing, rubbing down and stopping of surfaces and applying two coats of cement base paint complete all as specified.
M & L for coloured ceramic joint less tile of size 400x400x6-7mm thick over and incl 15mm thick cement screed in CM(1:6) set and jointed in neat cement slurry and pointed with white cement(over floor,skirting,almirah and shelves etc) mixed with pigment to match the colour of tiles including dismantling/roughening of surface complete all as specified.
M&L for RCC (1:2:4) type B-0 using 12.5mm graded aggregate as in slabs supported on walls,beams and columns in floors, roofs, landings, deck slabs, balconies, sunshade and in shelves including chase cutting and hooking/welding to existing RCC and like including demolition of existing reinforced RCC .
M&L For RCC (1:2:4) type B-1 using 12.5mm graded aggregate as in stairways,including steps,staircase railing etc and work of similar type complete all as specified and directed.
M&L for form work to soffits of suspended slab such as roof slab,Floor slab, shelves and chajjas etc and making surface fair finished complete all as specified and directed by Engr-In-Charge.
M&L for demolition of RCC as in beams,chajjas and similar work including cutting reinforcement as required complete all as specified and directed.
M&L for mild steel work as in hand rail, half round or other section for railings and similar work etc complete all as specified and directed by Engr-In-charge.
Material and labour machine pressed precast concrete interlocking coloured paver block any shape and size, IS 15658-2006 Marked, 60mm thick, M-35 grade with grey cement and pigment complete all as specified and directed.
M&L for sand filling under floor including watering and consolidation complete all as specified and directed.
Taking down aluminium/copper point wiring from existing conduit / batten (light, fan, socket or power) complete such as switches, ceiling rose, pendent, regulators, socket, light fittings etc and removing material from site and making good the disturbed surface of wall / floor etc, complete all as specified and directed
M&L for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi stranded copper conductor cable in old PVC Concealed conduit for one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed Note : The cost of sunken boxes and bakellite sheet is included in the quoted rate)
All as per Srl item No 125 above but for one 5 amps socket out let independent complete all as specified.
All as per Srl item No 125 above but on the same board completeall as specified
All as per srl item No 125 here in before but one light point controlled by 2-way switch.
All a per item No 125 above but with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth dolly complete.
Supply and Fixing in replacement switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement switch type regulator 5 step 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 5 pin, 6 Amps flush type 230 volts AC complete all as specified and as directed
Supply and Fixing in replcement of switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed
Supply and Fixing in replacement socket outlet 6 pin 6/16 Amps multi purpose flush type 230 volts AC complete all as specified and as directed
Supply and fixing in replacement ceiling rose 65X50 mm two to three terminals complete all as specified.
Material and labour for replacement of lamp holder insulated body complete all as specified.
Supply and fixing in replacement of Amp rating 240V, 10 KA, 'C' curve miniature circuit breaker (MCB) of Single pole 5 to 32 Amps current carrying capacity in the MCB DB complete with connection, testing and commissioning.
S & F in replacement of MCB 40 amps single pole with neutral, AC 230 volts complete all as specified and directed.
Supply & fixing in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
Supply and Fixing in replacement of bell push 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB and 12 outgoing MCBs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories :- (a) MCCB 100 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. (Note:- Out going MCB shall be measured and paid for separately)
Supply and fix in replacement for sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.0 Sqmm drawing into and including PVC non metallic rigid conduit medium grade of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor(green colour) and including non metallic medium grade rigid PVC conduit, including cutting chases in brick wall, and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 6.00 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 6.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
M&L in replacement of two single core sub main wiring 4 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 4 Sqmm as cotinuous earth wire connecting to common earth including conduit, connections of cable with MCBs or bus bars complete all as specified and directed Note :- (i) Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 4 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
M&L in replacement of two single core sub main wiring 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including PVC insulated copper conductor cable of size 2.5 Sqmm as cotinuous earth wire connecting to common earth including conduit, connections of cable with MCBs or bus bars complete all as specified and directed Note :- (i) Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 2.5 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 2.5 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Supply, laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size 50 mm outer dia and 38 mm inner dia complete all as speified and directed.
Supply and fixing ceiling fan 1200mm Sweep copper winding high speed, Aluminium body with blade, double ball bearing of BEE star rated Including all acessories connector, canopy, Hanging Rod and clamp, including electric connection with pvc flexible twin core copper wire from ceiling rose to ceiling fan complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade ) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PART 1 , with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switche, DBs) complete all as specified & testing on completion.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
Supply and fixing in replacement of LED T-8 tube light box type fitting with single side connection LED tube rod 22 watt, 4 feet MS CRCA box type including rotary type bipin holder and connection with PVC insulalted twin core 23/0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed.
Supply & fix in replacement of LED Street Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens. Note : The contractor will submit gauantee certificate for 01 years and replace complete item in case of any fault. No extra cost will be paid to the contractor for the same.
Supply and fixing in replacement of security light mounting bracket made out of GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat of size 40 x 6 mm and nuts and bolts and painting with aluminium paint,all as direced by Engr in Charge
Sand cushioning to cable with dry fine sand in trenches 8cm below the cable and 15cm above the cable after laying complete all as specified.
M/L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified
Supply and fixing in replacement of bell Ding Dong AC 230 volts complete all as specified and as directed
Taking down ceiling fan, exhaust fan in situ and refixing after servicing, repairing and painting to ceiling fan/ exhaust fan including exhaust fan louvers, scratching old paint and preparation of surface for painting with one coat of white / grey enmeled paint and including cable from ceiling rose to fan complete all as specified and as directed.
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
S&F in LED mirror fitting. 1x8w, 230v Energy efficient , Industrial Box type, housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 8 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engr-in-Charge.
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) distribution board for MCB provisions 240 Volt, 50Hz AC supply for 12 way. fitted with copper bus bar rated 200amps, neutral link , earth bar complete all as specified.
Supply and fix in replacement for MCBs single pole (SP) 40 Amps with 10 KA breaking capacity of 'C' series in distribution boards complete all as specified and directed.
Supply and laying in repair in trenches or fixing or passing through pipe,1100 volt grade heavy duty cable with XLPE insulated aluminium conductor ,served with an inner sheathing of PVC tape armoured with galvanised steel of size 50 sq mm X 3.5 corestranded conductor,complete all as specified and directed by engr-in-charge
Supply and fixing in replacement of Amp rating 240V, 10 KA, 'C' curve miniature circuit breaker (MCB) of SP 40 Amps current carrying capacity in the MCB DB complete with connection, testing and commissioning.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 16 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fix exhaust fan, steel body AC single phase, 230 V of size 300 mm sweep with, blades, and frame and louvers. Note : The quoted rate is include with making suitable hole in existing wall for fixing of exhaust fan.
S &F in replacement of LED bulk head light fittings 10watt white including LED strip as per IP65 in enginnering plastic housing withclear prismatic diffuser and making necessary connections complete all as specified
Supply and fixing geyser 25 Ltrs capacity , BEE 5 Star rated after connecting electric and water connection and screwing nut and bolts to fixed on wall and make surface complete all as specified and directed.
Taking down geyser any type in situ and refixing after servicing, repairing and painting includeding scraching old paint and preparation of surface for painting with one coat of white enameled paint all as specofied and directed.
M/s Vijay Construction Co.
M/s MAHAJAN CONSTRUCTION CO.
sandhu builders
B.J.CONSTRUCTION CO
Jaspal Construction Co.
tarlok singh contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .