Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.3 LAccepted-AOC | L-1 | Accepted-AOC tender accepted due to the lowest tenderer | |
| 2 | L-2₹18.6 L+₹294 (0.02%)Rejected-Finance | L-2 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE(I) N-29 OF 2023-24 REPAIR AND MAINT TO RMUs VCBs AND CONNECTED ITEMS AT NIWARU MIL STNUNDER AGE (I) NIWARU
2023_MES_601212_2
AGE (I)/N-29 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) Niwaru
CLASS E
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹40,000
Yes
2 Nov 2023
9 Sept 2023
2 Oct 2023
9 Sept 2023
30 Sept 2023
16 Sept 2023
Amount
Material and labour for routine preventive / breakdown maintenance & repairing of 11KV to 33 KV rating (Drawout / non drawout trolly type) Vacuum Circuit Breaker (VCB) doing the follwing work :- (i) Taking out VCB trooly from panel and carry out the cleaning dust / durt / any type of spark, general maintenance, oiling, greasing the mechanical / electrical parts such as spring charging motor mechanism, gears, lever spring, operating rod, male & female electric contacts ( Jaw contact assembly), bus bar shutter, tightening of nuts and bolts, cleaning any type of arc/ burning patch (ii) Repairing / Checking the AC/DC wiring, circuit including control fuses, CT & PT fuse and circuit jack, on/off push button, all type of commanding electric tripping / closing coils, all type of IDMT numerical / degital / analog relays, indicating lamp, voltmeter, ammeter, PF meter, gear box mechanism and springs etc., (iii) Relacement and testing of defective / unservisible electrical / mechanical parts. (iv) Reinserting the VCB in panel and setting of all types of relays as per load (v) Doing all type of standered tests and calibration of different type of relays such as Over current & earth fault relay, Trip circuit supervision relay, Master trip relay, Fuse failure relay, .Digital multifunction relay, Auxilary relay for Buch, WTI, OTI trip & alarm, Auxilary relay for PRV trip & MOG Alarm by injucting artificial electric load in the form of overload, short circuit current , and earth fault for tripping function & testing of all relays complete in all respect all as specified and submetting testing report as directed by Engineer-in-Charge.
Notes :- (i) Unserviceable items required to be replaced shall be measured and paid separately. (ii) Minor parts such as oil, grease, rust/ carbon cleaner, Nut/ bolts, wires is included in the unit rate quoted above. (iii) Unit rate quoted against this item shall include the engineer, electrian & labour required for repair / replacement of unserviceable spare parts. (iv) The above work shall be carried out only and only by the OEM of CG ( Crompton Greaves ) Engineer, Electrian. No local / any other ageny, Company Engineer / Crompton greves dealer will be allowed to carryout the work. Engineer will come directy from OEM CG ( Crompton Greavs) company. Contractor will submit the evidance in this regard and will take permission before starting the work. (v) All the mechanical, electrical parts / relays / coils to be replace will be of same make and type as per existing installed on site. (vi) The contractor shall check the existing system of VCBs for maintenance of VCB parts before quoting the tender. (vii) The maintenace of VCB once measured will not be paid again in this contract if any other type of fault come after the servicing. Only spare parts will be paid. No any other type of labour/ Electrian / Engineer cost will be paid saperatly (viii) As the VCB is a critical equipment from the safety point of view for the electric supply system. If any fault comes in the VCBs the contractor will have to attend and rectify the same with in 48 Hrs .Failing to attend the fault within given time a panelty will be imposed @ 500 / day till the rectification of fault.
Supply and fix in replacement, making connection and testing of numerical based Overcurrent and earth fault protection relay of make Schneider electric / Alstom, model No:- MiCOM P127 having 08 Nos LED indicator for showing different type of signals, operating on VX 24-250 Vdc 48-240 Vac, Protection type:- Overcurrent ANSI code: 50/51, Recloser ANSI code: 79, Cold load pick-up Earth fault ANSI code: 50G/51G, Lockout ANSI code: 86, Negative sequence overvoltage ANSI code: 47, Under voltage ANSI code: 27, Overvoltage ANSI code: 59, Rate of change of frequency ANSI code: 81R, Neutral voltage displacement ANSI code: 59N, Thermal overload protection ANSI code: 49RMS, Under frequency ANSI code: 81L, Phase undercurrent ANSI code: 37, Breaker failure ANSI code: 50BF, Negative sequence overcurrent ANSI code: 46, Restricted earth fault ANSI code: 64REF, Directional earth fault ANSI code: 67N, Directional phase overcurrent ANSI code: 67, Over frequency ANSI code: 81O, Voltage-restrained overcurrent ANSI code: 50V/51V,
Number of inputs:- 4 - current input CT...X/5 A and X/1 A, 3 voltage, 12 discre, Number of outputs:- 9 discrete, Communication port protocol :-DNP3, IEC 60870-5-103, Modbus RTU, Control and monitoring type:- Circuit breaker/contactor control, Network and machine diagnosis type:- Fault recording, Event recording, Disturbance recording15 s, Switchgear diagnosis type:- CT/VT supervision Trip circuit supervision ANSI code: TCS, Display type:- Backlit LCD: 2 lines of 16 characters, Discrete input voltage:- 24...250 VDC 19.2 V standard variant, 48...250 VAC 19.2 V standard variant, Communication port support :-RS232 RS485, Type of measurement:-Current, Height 177 mm total: 156 mm embedded:, Width 155 mm, Depth 249.6 mm total: 223 mm embedded, Device mounting Flush all as directed and specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based fuse failure relay, 3 pole , Vx 110 AC 50 Hz, type VAPM31AF of Make Alstom all as per existing installed and as directed and specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Triping relay, Vx 24-27 V, DC, type VAJH13YF of Make Alstom all as per existing installed & directed and as specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Trip circuit supervision relay, 3 pole, Vx 24-27 V, DC, type VAX31ZG of Make Alstoma as per existing installed and as directed and specified by Engineer-in-Charge.
Supply and fix in replacement Electro mechanical based Auxiliary relay, 3 pole , Vx1 110-125 V, AC type VAA33ZG of Make Alstom all as per existing installed directed and as specified by Engineer-in-Charge.
Supply and fix in replacement Tripping coil along with solenoid operating on 24 V DC, R 1.7Ω +-5% as per existing installed on site in 11 KV rating VCB.
Supply and fix in replacement closing coil along with solenoid operating on 24 V DC, R 1.7 Ω +-5% as per existing installed on site in 11 KV rating VCB.
Supply and fix in replacement Tripping coil along with solenoid operating on 24 V DC, R20 3.0 Ω +-5% as per existing installed on site in 33 KV rating VCB.
Supply and fix in replacement Closing coil along with solenoid operating on 24 V DC, R20 3.0 Ω +-5% as per existing installed on site in 33 KV rating VCB.
Supply and fix in replacement Spring charging motor operating on 220 V AC / DC supply, FL Watts 150, type PMR 5 of make DELCO as per existing installed on site in 11 KV rating VCB.
Supply and fix in replacement Spring charging motor operating on 230 V AC/DC, type C36, O/P 0.1KW of Make:- KPT shirol, as per existing installed on site in 33 KV rating VCB.
Supply and fix in replacement high voltage Porcelain material H.R.C CT / PT ( Current transformenr / Potential transformer) fuse 11 KV rating 1 Apms- of make Bussmann of suitable length and diameter to be install in 11 KV rating VCB.
Supply and fix in replacement high voltage Porcelain material H.R.C CT / PT ( Current transformenr / Potential transformer) fuse 33 KV rating 3.15 Apms of make Bussmann of suitable length and diameter to be install in 33 KV rating VCB.
Supply and fix in replacement DC power pack of capacity 7AH, 220 / 110 V AC incoming and 24 V DC outgoing all as per existing installed in 11 KV VCB
Supply and fix in replacement rechargable battery of capacity 7 AH , 12 V / 24 V all as per existing installed in DC power pack of 11KV VCB.
Supply and fix in replacement Breaker control Switch Three position :-Trip, close and neutral control switch (TNC) for operation of 11KV / 33 KV VCB all as per existing installed on site.
Supply and fix in replacement three phase, 4 digit Digital type ammeter meter having indicators for each phase, accuracy class 0.5, to be install in 11KV VCB as per existing installed specification. Make:- Elmeasure / ABB / L&T
Supply and fix in replacement three phase, 4 digit Digital type voltmeter meter having indicators for each phase, accuracy class 0.5, to be install in 11KV VCB as per existing installed specification. Make:- Elmeasure / ABB / L&T
Supply and fix in replacement HRC fuse link type NSD type FA 02 Amps to 20 Amps, 500 V.
Supply and fix in replacement LED pilot lamp Indicator working on AC/ DC power supply on any voltage to be install in 11 KV VCB in any colour as per requirement on site & as per existing installed on site.
Supply and fix in replacement Ammeter / Voltmeter Switch, four position :R ,Y, B and off position slelection for operation in 11KV / 33 KV VCB all as per existing installed on site.
Supply and fix in replacement push button NO / NO type all as per existing installed on site and directed and specifiec by Engineer-in-Charge.
Supply and fix in replacement Bridge Rectifier Diode all as per installed in 11 KV VCB all as per specified and directed by Engineer-in-Charge.
Supply and fix in replacement Epoxy support Insulator 40mm dia, 11KV, single holes of 12mm dia type, 150mm long as per existing make & model. specified and directed by Engineer-in-Charge.
Supply and fix in replacement Epoxy support Insulator 100mm dia, 33KV, 4 holes of 16mm dia type, 300mm long as per existing make & model specified and directed by Engineer-in-Charge.
Supply and fix in replacement CT ( current teansformer) type BWP3, STC 18.4 KA for 1 sec, core 1 :15VA class 0.5, core 2 : 15VA class 5P10 of make CG ( Crompton greaves) , copper wound, P1/P2 type of ratio 100-50/5-5A, 50 Hz as per IS-2705/1992, Ins. Class B, suitable for 11 KV VCB Panelas per existing and directed and specified by Engineer-in-Charge.
Supply and fix in replacement CT ( current treansformer) copper wound, P1/P2 type of ratio 100-50/5+5A, 50 HZ as per IS 2705-1992,CT frame HF-CT-401, Ins. Class B, HSV/IL : 36/70/170KVp, 50 Hz, Str-25 KA / 1 Sec, VA/class for core 1 - 15 VA /class 1.0 and for core 2 - 15 VA /class 5P10 make : CG ( Crompton greaves) suitable for 33 KV VCB as per existing make and model or as directed by EIC.
Supply and fix in replacement PT ( Potential transformer) suitable for 11 KV VCB Panel, copper wound, P1/P2 type of ratio 11000/110 Volt as per IS 2705-1992, Ins. Class B, 50 Hz, Str-25 KA / 1 Sec, as per existing make and model or as directed by EIC.
Supply and fix in replacement PT ( Potential transformer) suitable for 33 KV VCB Panel, copper wound, P1/P2 type of ratio 33000/110 Volt as per IS 2705-1992, Ins. Class B, 50 Hz, Str-25 KA / 1 Sec, as per existing make and model or as directed by EIC.
Supply and fix in replacement LV plug connector suitavle for 11 KV VCB controlling all as per existing and specified and directed by Engineer-in-Charge.
Supply and fix in replacement Male & female Jaw contact set of rating 11 KV, 800 Amps to be install in 11KV VCB all as per existing installed and specified and directed by Engineer-in-Charge.
Supply and fix in replacement HT vaccum interrupted assembly bottel with flex connection suitable for 11 KV VCB 800 Amps capacity for RYB phases as per installed complete all as specified and as directed by Engineer-in-Charge.
M & L arrangement of Crompton greavs company engineer for technical visiting of 3.15 MVA, 33 KV / 11 KV transformer and finding of the fault / causes for overheating of transformer , calibration of WTI ( winding temprature indiactor ) and OTI (Oil temperature indicator) and testing of oil sample as per different paramater as per IS 335 amended 2018, (i) Appearance (ii) Viscosity at 40 ºC (iii) Viscosity at 0 ºC (iv) Density at 20 ºC (v) Flash Point (vi) Interfacial Tension (vii) Water content (viii) Breakdown Voltage (ix) Acidity (x) Electrostatic Charging Tendency (xi) Sulphur Content alla sdirected and specified by Engineer-in-Charge. Note:- If the insulating oil fails in any requirement, two more samples shall be drawn from the same consignment and tested for those particular requirements
M & L for onsite trasformer repairing for preventing oil leakage / any other type of minor fault such as HT / LT bushing replacement / gasket replacing / gate valve replacement by draining out the oil and refilling after filteration & dehydration and testing all as specified and directed by Engineer-in-Charge. Note:- (i) Rate of any type Rubberised cork/neoprine gasket and filtration of oil is included in the unit rate quoted above. (ii) HT / LT Bushing as supply only will be paid saperatly.
Material & Labour for disconnecting of defective/ unservisible transformer (indoor/outdoor type) 11KV/433 volts copper wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted and transporting the same to workshop in the presence of rep of AGE (I) and opening the transformer cover, draining out of transformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts i.e.windings, tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all parts including taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint and preparing the same for re-assembling after carrying out required repair and installation on existing 2/4 pole structure/ platform with necessary fixing arrangement including connecting up electrically, commissioning and testing etc complete all as specified and directed by Engineer-in-Charge and specified in particular specification of the following capacity :- NOTE: (i) Repair cost is deemed to be included labour,transportation, balancing or alignment of core etc in the quoted rate; and Unserviceable items required to be replaced shall be measured and paid separately. (ii) The burnt transformer oil will be contractor property & any new oil will be measured and paid separately under respective item. (iii) The coils and the oil shall be inspected for repair/replacement by department rep detailed by AGE (I). (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (v) Rate of any type Rubberised cork / neoprine gasket and filtration of oil is included in the unit rate quoted above
(a) 63 KVA to 200 KVA capacity
(b) 350 KVA to 400 KVA capacity
Supply only following parts for indoor /outdoor transformer :-
Supply only new copper wire wound coils for LT / HT winding of transformers with super enameled copper winding wire of suitable gauge so as to match with the working capacity of transformer and all as per manufacturer’s design and specification including providing Class-E insulation and fixing HT / LT coils in position and connecting electrically in core assembly of capacity 63 to 630 KVA for replacement during repair of transformer.
Supply only HT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer :-
(a) 63 KVA to 160 KVA capacity
(b) 350 KVA to 400 KVA capacity
Supply only LT porcelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer :-
(a) 63 KVA to 160 KVA capacity
(b) 350 KVA to 400 KVA capacity
Supply and filling new mineral grade transformer oil (ISI marked) EHV type conforming to latest IS-335 for filling and for topping up in transformer duly filtered with filtration plant to obtain high dielectric strength 50 KV to 60 KV complete all as specified and as directed. Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor . Nothing extra shall be paid on this account. If oil is used for top up no schedule of credit will be issued. Only in replacement case old oil will be issued under schedule of credit.
Supply and fix in replacement fresh Silica Gel into the silical gel breather complete all as specified and directed
Supply and fix in replacement stainless steel analog oil Temperature gauge along with prob, thermal based to be install in 400 KVA transformer all as directed and specified by Engiineer-in-Charge.
Supply and fix in replacement analog oil Temperature gauge along with prob, thermal based to be install in 3.15 MVA transformer all as directed and specified by Engiineer-in-Charge.
Supply and fix in replacement R1 size silica gel breather assembly along with silica gel, made of aluminium head and bottom, to be install in 400 KVA transformer all as directed and specified by Engineer-in-Charge.
Supply and fix in replacement R2 size silica gel breather assembly along with silica gel, made of aluminium head and bottom, to be install in 3.15 MVA transformer all as directed and specified by Engineer-in-Charge.
Material and labour for Repair & maintenance of unserviceable auto tap changer and its control panel for transformer of capacity 3.15MVA , 33 KV / 11 KV, 50 Hz, auto tap changer capacity of 17 step for +5% to -17.5% to make it fully functional complete all as specified and as directed. REair will be carried out only by the OEM Engineer all as specified and directed and specified by Engineer-in-Charge.
Supply and fix in replacement Automatic voltage regulating relay Make Pradeep model No FX 4000 for operation of auto tap changer installed in 3.15MVA, 33KV /11 KV transformer of all as specified and diredted by Engineer-in Charge.
Material & Labour for taking down old MS structure, channels, airbreak gangoperated devices, dropout fuse carefully, dismantling existing 11 Meter PCC pole and Supply and erectection of 11 meter PCC pole with excavation, removal , returning and PCC for foundation of pole, and refixing all channels / GOD, DO complete all as specified and directed by Engr-in-charge. Note: - Excavation, PCC work is included in the quoted rate. Old MS structure such as clamps, channels, Airbreak gangoperated device, Dropout device shall be refixed without any cost.
Supply and fix in replacement polymer (silicon rubber) material (GOAB switch) Switch air break, gang operated outdoor, vertical operated type, HT 11 KV, Triple pole ( three phase), 200 Amps, 3 insulator per phase, tilting/rocking vertical type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts without drop out fuse assembly and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, fixed in repairs, complete all as specified and as directed.
Supply and fix in replacement polymer (silicon rubber) material Drop out expulsion fuse assembly with fuse carrier, triple pole ( three phase), HT 11000 Volts, 200 Amps, outdoor type (having two Nos post insulator mounted on MS channel for each pole) and jumpers with conductors line taps, clamps, colour coated HT sleeves and fitting, fixed in repairs, complete all as specified and as directed.
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 Volts, 240 Sq mm, 3 core cable grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing in repair, complete all as specified and directed. (Note:- Old cable is under hadrstanding hence complete length shall not be available under schedule of credit.)
Supply and fix cable end jointing kit for 11 KV grade cable for Outdoor termination, Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified.
Supply and fix cable end jointing kit for 33 KV grade cable for outdoor termination, Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified.
S.R.Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .