Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC Bidder is L1 | |
| 2 | L2₹3.0 L+₹13,163 (4.57%)Rejected-Finance | L2 | Rejected-Finance As per NIT | |
| 3 | L3₹3.3 L+₹43,893 (15.2%)Rejected-Finance 2099 6A GALI NO 15 PREM NAGAR NEW DELHI 08 | NEW DELHI | DELHI | 110001 | L3 | Rejected-Finance As per NIT | |
| 4 | L4₹3.5 L+₹56,813 (19.7%)Rejected-Finance NULL | L4 | Rejected-Finance As per NIT | |
| 5 | L5₹3.7 L+₹83,423 (28.9%)Rejected-Finance | L5 | Rejected-Finance As per NIT |
Tender Value
₹4.0 L
EMD Value
₹8,000
Closing Date
25 Aug 2023, 12:00 pmClosed
SUDHIR KUMAR
OLD ZONAL BUILDING
Improvement of electrical installations in Homeopathic Dispensary, Khajan Basti under west zone. Tube fixtures, fans and compound lights.
2023_MCD_164839_2
EE/Elect/WestZone/2023-24/14
Open Tender
Electrical Works
Works
60 days
WEST ZONE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹8,000
13 Sept 2023
18 Aug 2023
25 Aug 2023
18 Aug 2023
25 Aug 2023
18 Aug 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt+/-S%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
supply of 12" (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutters, blades etc as req.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 250 mm X 75 mm deep
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
6 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
3 x 6 sq. mm
6 x 6 sq. mm
Supply of 3 mm thick phenolic laminated sheet
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply of XLPE insulated, PVC sheathed Al. conductor Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes.
2x10 sq mm
2x6 sq mm
P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200xl60x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/lsolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with 55 back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt+/- 5% (b) Luminaire Efficacy>=l00 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
SITC of wall mounted Fan 400 mm sweep rated voltage 220-230 AC rated frequency 50Hz speed 1280-1350 rpm with desire colour
SITC of On-line UPS with inbuilt isolation transformer suitable for single phase AC input and single phase AC output, Floor mounted type, indicative power backup time of 60 mins through SMF batteries. 3KVA
SITC of single phase monoblock pump set complete with all accessories workable on 240/515 volts, 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25x25 mm.
ELECTROMECH ENTERPRISES
ROSE ELECTRICALS
S.N. Enterprises
BEST ELECTRICALS & ELECTRONICS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .