Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.5 L+₹71,472.57 (3.14%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹55,300
Closing Date
20 Jan 2021, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura Cantt
PROVN OF TRANSFORMER AND CONNECTED ITEMS AND RING MAIN SYSTEM FOR RESIDENTIAL COLONY AT HISAR MIL STN UNDER GE HISAR
2020_MES_405878_1
CWE/MTR/HSR/69 of 2020-21
Open Tender
Civil Works
Item Rate
180 days
Hisar
Class D cat b (ii)
7 documents required · 7 mandatory
₹500
GE Hisar
₹55,300
Yes
19 Feb 2021
23 Dec 2020
22 Jan 2021
23 Dec 2020
20 Jan 2021
8 Jan 2021
Amount
Supply, installing, testing and commissioning outdoor type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC, 3 phase, 50 Hz, 250 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural- Air Natural , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at ± 2.5% & ± 5.0% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40°C. The transformer shall be conforming to IS-1180 updated energy efficiency, level-2 complete all as specified and directed and shall comprise of the following :-
(i) Three nos porcelain bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers.
(ii) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods complete with nuts and washers, with cable glands suitable for reception / taking out of 300 Sqmm 3.5 core LT 1100 volts grade PVC / XLPE insulated & sheathed, heavy duty, armoured cables including joint and jointing materials complete.
(iii) Oil conservator with filter type drain valve and oil level gauge.
(iv) De-hydrating breather with first fill of dehydrating agent (silica gel).
(v) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs for complete transformer and as well as core and winding assembly, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four Nos plain solid cast steel detachable rollers.
(vi) One No 100 mm dia, dial type thermometer, vapor pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(vii) Two earthing terminals on tank cover to facilitate fixing of 25x4mm galvanized iron earth strip for earthing of body
(viii) Rating plate and terminal marking plate.
(ix) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
(x) First filling of new and unused transformer oil, IS-335 marked (Make Savita / Power Link) filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes.
(xi) Arcing horns for HT side (01 No per phase)
M&L for switch air brake gang operated triple pole mechanically operated mounted on HT insulators (09 insulator) horizontal type and MS galvanized steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating upto 200 Amps 11000 volts complete with locking arrangement , MS clamps ,bolts ,nuts and washers etc. including two coat of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed. Note : (The quoted rate should be inclusive of jumpers, Aluminium thimbles, connections etc. The handle should be covered with PVC sleeves)
Supply and installation drop out fuse assembly single pole 11 KV, 25 Amps rating complete expulsion fuse element on four pole structure complete all as specified and directed.
S&F lightening arrestor suitable for 11000 voltage expulsion type complete with all fittings, transmission class, discharge capacity 65 KA complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried, directly and vertically in the ground to depth not less than 2.25 mtr below the ground level with top edge of earth plate not less than 1.5 meters below normal ground level connected to galvanised iron earthing strip 25 x 4mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GI pipe light grade 40mm bore for protection of earth lead and GI watering pipe 20mm bore light grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type C-1, 80mm thick pre cast RCC 1:2:4 type B-1 cover reinforced with 8mm #bars @ 100mm c/c both ways earth plate surrounded by alternate layres of packed charcoal salt packed which shall be not less than 15 cm in all sides of earth plate all as shown in electrical plate No-3 MES Sch Part-I complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried, directly and vertically in the ground to depth not less than 2.25 mtr below the ground level with top edge of earth plate not less than 1.5 meters below normal ground level connected to galvanised iron earthing strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, GI pipe light grade 40mm bore for protection of earth lead and GI watering pipe 20mm bore light grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type C-1, 80mm thick pre cast RCC 1:2:4 type B-1 cover reinforced with 8mm #bars @ 100mm c/c both ways earth plate surrounded by alternate layres of packed charcoal salt packed which shall be not less than 15 cm in all sides of earth plate all as shown in electrical plate No-3 MES Sch Part-I complete all as specified and directed. Note :- The unit rate includes for protection pipe and GI strip 32 x 6mm from top of earth plate up to 7.5 meter above ground level.
Supply, laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade (Earthed) of size 95 sqmm 3 core confirming to IS-7098 Pt-II, cable laid in trenches /walls /ducts/ poles complete all as specified and directed.
Supply, laying, testing and commissioning of HT Underground XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11 KV grade (Earthed) of size 120 sqmm 3 core confirming to IS-7098 Pt-II, cable laid in trenches /walls /ducts/ poles complete all as specified and directed.
Supply and jointing testing outdoor type cable end termination (heat shrink type) complying with jointing materials and accessories suitable for 11 KV underground XLPE, HT cable of size 95 Sqmm 3 core (earthed) complete all as specified and directed by Engr In Charge.
Supply and jointing testing outdoor type cable end termination (heat shrink type) complying with jointing materials and accessories suitable for 11 KV underground XLPE, HT cable of size 120 Sqmm 3 core (earthed) complete all as specified and directed by Engr In Charge.
Supply, laying, jointing, testing and commissioning of LT UG XLPE insulated screened PVC beded galvanised steel strip or wire, armoured heavy duty electric power cable with aluminium conductor, 1100 volt grade, cross sectional area, laid in trenches wall / floor complete all as specified and as directed of following size :- Note : Cable may be laid in trenches, under road, across the nallah, along poles / walls and ducts etc. Excavation, earthwork, sand chshioning, cable cover, pipe for cable protection to be measured and paid saprately.
3 ½ core 240 Sqmm
3 ½ core 120 Sqmm
Excavation in trenches in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable etc and for foundation of poles, stays etc, not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Excavation in trenches in hard / dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable etc and for foundation of poles, stays etc, not exc 10 sqm on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick of soft / loose soil in trenches/pit complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L Sand cushioning to underground cable in trenches in layers of 8 Cm deep before laying the cable and 15 Cm deep after laying and stretching the cable complete all as specified and directed. Note : Punned thickness shall be measured and paid for.
M&L for brick covering to underground electric cable using sub class "B" old size brick laid dry flat per pendicular to the direction of cable complete all as specified and directed.
Supplying and laying un-reinforced pre cast concrete cable cover of class HV type1 flat size 300 mm x 180 mm x 40 mm fixed in replacement of any type bricks or PCC covers
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures, and coventional skull and bones, in signal red colour and fixed with MS Clamps, bolts, and nuts of approved size, for HT 25 X 20 cm size complete all as specified and directed.
M&L for Anti-climbing device spikes type fabricated out of MS bars (round, Square and flat) including nuts, bolts, washers, and welding into halves made to shape to suit the cross section of the pole complete all as specified and directed.
M&L for laying 20mm stone aggregate in electrical installation or below 4 pole structure etc complete all as specified and directed.
S&F Steel tubes light grade galvanized with all fittings fixed to walls / floors / poles of following sizes complete all as specified and directed.
80 mm dia
100 mm dia
Supply and fixing HT cable route / joint indicator made of Cast iron fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) of block size 30 x 30 x 20cm on angle iron of size 40 x 40 x 5mm of suitable height with nut, bolt & washers of suitable size complete all as specified and directed.
Supply, installation, commissioning and testing of feeder pillar board Kiosk type, LT(415 Volts, 50 Hz, 3-phase, 4 wire supply) CPRI approved, factory assembled, out door type, weather and vermin proof (Protection Class IP-65) made out of 40mm x 40mm x 5mm angle iron frame and 3.15 mm thick (for external) and 2mm thick (for internal) MS Sheet CRCA sheet duly compartmantalised for each control MCCBs single door system lockable by keys. The outer cell shall have both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with nine tank pretreatment solution prior to a powder coat of SIEMENS grey shade RA 7032 (Berger / Nerolac) (First Quality) over a coat of red oxide primer complete mounted on angle iron 40mm x 40mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including blocks of PCC (1:2:4) type B1 of block size 30 x 30 x 30 cm complete all as specified and directed and comprising of the following:-
(a) Bus bar chamber having 4 Nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB as well as outgoings MCCBs, All spreader terminal of MCCBs should be connected with bus bars.
(c) Outgoing:- (i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 320 amps rating and 36 KA rupturing capacity, adjustable type (Ics = 100%Icu). -01 No. (ii) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 200 amps rating and 36 KA rupturing capacity, adjustable type (Ics = 100%Icu). -01 No. (iii) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 160 amps rating and 36 KA rupturing capacity, adjustable type (Ics = 100%Icu). -01 No. Note : (i) All incoming/ outgoing cables shall be connected by suitable size gland plate / glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar). (ii) Fine wiring with single core copper conductor for instruments / indicating lamps - 01 Job.
Supply, errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 11 mtr long, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete as specified and directed. Note : (i) The conductors / earth wires on existing pole to be shifted on new pole after errection of new pole. The rate shall be include in above quoted rate. (ii) Earth work & PCC shall be measured and paid separately.
M&L for providing 100mm PCC platform on top of brick masonry of Size 6x3 mtrs (outer dimensions) and 1.2 mtr high from ground level and 0.5 mtr below ground level for placing RMU / Transformer chainlink fencing around the platform fixed to angle iron post 1.8 mtr high using angle iron of size 40mm x 40mm x 6mm and 1.00m away from platform with entry gate and steps and applying a coat of black bituminious paint over a coat of red oxide primer on the steel surfaces complete all as specified and directed including provision as under :- (i) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation of brick wall and fencing post including excavation & earthwork, return filling in and removal of surplus soil. (ii) Brick work with fly ash brick in CM 1:6 including 15mm thick plastering in CM 1:4 over exposed surfaces. (iii) 100mm thick hard core using brick bats of grade n.exc 63mm. (iv) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base. (v) 100mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in flooring finished even and fair. (vi) Two coats of cement base paint over a coat of cement primer over plastered surfaces complete. (vii) Chain link MS galvanised fencing of mesh size 75mm x 75mm and dia of wire 3mm complete. (viii) Earth filling including watering and ramming in layers of 25cm inside the platform complete. (Earth obtained from excavation shall be used for filling)
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in mass concrete and filling complete for foundation of pole complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in mass concrete including necessary form work complete for foundation of panel & transformer yard, pole / stay of pole complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate in coping and like including weather slightly rounded or chamfered angles and throaty including necessary form work for pole complete all as specified and directed.
Supply, installation ,testing and commissioning RMU (Ring main unit), outdoor type ,both sides ,extensible type ,SF6 gas filled, 3 functions comprising 1x630 amps load break switches (isolators) incoming and 2x630 Amps VCB (vaccum circuit breaker) in outgoing rated voltage 12 KV rated short duration power frequency withstand voltage 30 kv rated lightening impulse withstand voltage 75 kv ,rated frequency -50 Hz rated normal current 630 Amps rated short time withstand current 13.12 kA rated peak withstand curent -33 kA rated duration of short circuit -3 sec rated operating sequence 0.3 mm CO-3 min CO motorised and suitable to be connected to F-RTU so as to be monitored and controlled manually complete as specified and as directed including the following provisions
(i) Manually operated earthing switch with full marking (ii) Shunt trip coil for external tripping (iii) Self powered non-directional IDMT (inverse definite minimum time) over current and earth fault relays (Microprocessor based) One three element relay having two O/C element and one E/F element shall be provided for this purpose. All these relays shall be of 3 seconds IDMT characteristics, the O/C element current setting variable. (iv) Cable testing facility without disconnection (v) Emergency trip push button (vi) Live cable indicators (vii) Cable box termination of cable for CB (viii) Necessary wiring and installation on foundation as per manufacturer's instructions
SAINI ELECTRIC STORE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .