Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | ₹20.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹21.0 L+₹97,000 (4.84%)Rejected-Finance | ₹21.0 L+₹97,000 (4.84%) | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹26.4 L+₹6.4 L (31.9%)Rejected-Finance | ₹26.4 L+₹6.4 L (31.9%) | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹26.6 L+₹6.5 L (32.6%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | ₹26.6 L+₹6.5 L (32.6%) | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹29.5 L+₹9.4 L (47.1%)Rejected-Finance PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | ₹29.5 L+₹9.4 L (47.1%) | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Jun 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR TO ROOF WATER PROOFING TREATMENT, LEAKAGE/ SEEPAGE, SHAFT REPAIR, PARAPET WALL/CHAJJAS, PLINTH PROTECTION AND ALLIED B/R SERVICES AT MD ACCN BANA SINGH ENCLAVE, 180 ORS MAHIPALPUR AND OTM ACCN (35 INF BD, 18 MADRAS, 5/11 GR) UNDER AGE BR-II O
2023_MES_598042_1
GE/DS-20/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹80,000
Yes
6 Jul 2023
24 May 2023
23 Jun 2023
24 May 2023
21 Jun 2023
7 Jun 2023
Amount
Cutting of vegetable plant (girth not exceeding 300mm) from roof, terrace, chajjas etc digging out the roots and making good the surface in PCC 1:2:4, type B-1 with surfaces finished to match complete including scaffolding etc. complete all as specified and as directed.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of mud in roof, any thickness, including plastering and leeping upto two storey bldg including necessary scaffolding arrangement complete (whether full thickness removed or only a part there of) and removing rubbish from cantonment area or as directed complete all as specified and as directed.
M&L for cutting out craks to V-section in existing roof or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
M&L for Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:-
(a) Applying oil bound bituminous primer at the rate of 0.30 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated.
(b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35).
(c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, (weight not less than 160 gm/Sqm) with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface.
(e) Make of APP : "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE.
Note:- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for PCC 1:2:4, type B-0, using 12.5mm gradded aggregate to maintain slope as in roof padding alongwith liquid water proffing compound.
Supply only liquid water proofing compound conforming to relevant IS complete all as specified and as directed.
M&L for cement concrete tiles 20cm x 20cm x 25mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, and cut and polished laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed (Over accessible roof only).
M&L for preparation of surfaces and applying two coats of aluminium paint on top of roof surfaces complete all as specified and as directed (Over non-accessible roof only).
Dismantling of floor of WC with WC seat & taken out the cinder from sunken portion of WC,taking down of cement plaster of any thickness & description of wall & floor. Provide 25mmdia GI pipe spout projecting at least 150mm beyond outer face of wall. 15mm thick plaster 1:4CM with WPC both on floor& wall. Then apply Epoxy Resin Coating polymer (water proofing coating for sunken portion) both on floor as well on wall.Sunken portion filled with graded cinder &laid 50mm thick floor in PCC 1:2:4 (20mm graded stone agg.) floor area not exc. 3.50 sqm complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. over and including 15mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for joint free glazed ceramic coloured tiles in vertical surface 450x300x7mm thick over 10 mm thick cement plaster in CM 1:4 as in backing set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.
Demolition of cement concrete in floors of any description and in any postion complete all as specified and as directed.
Demolition of reinforcement cement concrete of any discription and in any position, including cutting of reinforcement from adjoining RCC component to faciliate demolition complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specially provided for including cutting of reinforcement to facilitate demolition (Parapet wall) complete all as specified and as directed.
M&L for reinforced cement concrete type 1:2:4 using (20 mm graded stone aggregate) as in fins, fascias, louvres, parapets, and railings, newels, balustrade, and the like complete all as specified and as directed.
S&F TMT bars 10 mm dia & over as in reinforcement of columns, beams, RCC, slabs, chajjas, lintels etc cut to length bent to shape required including cranking, bending, spirally hoping for columns, hooking ends and welding the new reinforcement with old steel bars complete all as specified and as directed.
S&F 8mm dia TMT bars, cut to length bent to shape required including cranking bending spirally for hoping for columns, chajjas to parapets etc hooking ends and binding with mild steel wire not less than 0.90mm dia complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work etc. complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quions, pillars, ashlar facings, dressed stone work and precast articles etc. complete all as specified and as directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6mtr mean radius built in cement mortor 1:6 complete all as specified and as directed.
M&L for brick work with fly ash bricks strainght or curved on plan to any radius in half thick in CM 1:4 brick wall built in cement mortor complete all as specified and as directed.
S&F in repairs 15 mm bore GI tubes, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors or in concealed etc. complete all as specified and as directed.
All as per Srl item No.24 above, but 20 mm bore of pipe.
M&L for cutting chases or making holes, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed.
S&F in repairs 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
S&F ball brass valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball ascrewed for iron pipe of 20mm bore and fixed complete all as specified and as directed.
S&F in repairs gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore complete all as specified and as directed.
S&F in repairs PVC connections 450mm long with brass unions at both ends suitable for 15mm bore pipe complete all as specified and as directed.
S&F in repairs 15 mm bore angle valve/ stop valves, cast copper alloy, chromium palted, fancy type screwed down high pressure with crutch and butter fly handles, screwed with iron pipes or for union complete all as specified and as directed.
S&F in repairs bib tap (quarter turn), brass chromium plated fancy type, long body with flange screwed down, screwed for iron pipe 15 mm bore complete all as specified and as directed.
S&F in repairs mixing valve 15 mm dia, CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin, including fittings complete all as specified and as directed.
S&F in repairs 15 mm bore two way angle valve/ stop valves, cast copper alloy, chromium palted, fancy type screwed down high pressure with crutch and butter fly handles, screwed with iron pipes or for union complete all as specified and as directed.
S&F in repairs chromium plated grating with 100mm dia of approved make including fixing with 1:4 CM to floor/ nahni trap etc. complete all as specified and as directed.
S&F in repairs grating doom 125mm dia with waste hole of PTMT (minimum weight 40 gms) etc. complete all as specified and as directed.
S&F in repairs PVC valveless, syphonic action type flushing cisterns 10 ltrs capacity, low level, white, with inlet ball valves, float and handle including brackets and pvc flush pipe 32 mm dia for low level complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin, white, flat back of size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets,complete all as specified and as directed.
Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and as directed.
S&F factory made solid PVC chowkhat/ door frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet and edges will be painted to match with printed PVC sheet reinforced with 19 mm x 19mm MS square tube of 19 gauge including rubber gasket, PVC fastners, screws, brackets, and shown on drawing as per SSR part-II (2020) complete all as specified and as directed.
S&F factory made solid PVC moulded door shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick wood grain printed moulded prelam PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed.
S&F stainless steel butt hinges, size 100 mm complete all as specified and as directed.
S&F stainless steel barrel tower bolts, 150 mm long complete all as specified and as directed.
S&F stainless steel handles, 150 mm long complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, concrete surface etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for 15mm thick rendering with ready mix plaster on faces of brick or concrete surface, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering with ready mix plaster on concrete surfaces of ceiling, chajja,etc finished even and smooth complete all as specified and as directed. Notes for Srl item Nos. 46 & 47 :- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech Readiplast/ACC Accoplast/Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment from internal surfaces of wall by electrically operated grinder, washing and filling of holes with filler material and applying 1 to 2 mm thick wall care putty in two layers on whole wall surface including grinding with sand paper and levelling the surface and than applying two coats of oil bound distemper on white or tinted surfaces over existing prepared putty based surface complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes upto internal dia 150mm jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed.
S&F 110 mm dia UPVC pipes Type 'B', single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and as directed.
S&F 75 mm dia UPVC pipes Type 'B', single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and as directed.
S&F 75mm dia UPVC (SWR) bends type ‘B’ (any radius) complete all as specified and as directed.
S&F 100mm dia UPVC (SWR) bends type ‘B’ (any radius) complete all as specified and as directed.
S&F in repairs UPVC ‘P’ or ‘S’ trap including jointing with solvent cement, dia of outlet 100mm bore complete all as specified and as directed.
S&F 75mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal provided with oval access doors complete all as specified and as directed.
S&F in repairs UPVC floor/ nahani trap including jointing with solvent cement, dia of outlet 75mm bore complete all as specified and as directed.
S&F in repairs 125mm x 100mm salt glazed stone ware gully traps square & round mouthed trap 'P' including case iron grating and fixed, including necessary excavation and earthwork, concrete in bed, surrounds, kerbs etc., and jointing to drains in CM 1:1 complete all as specified and as directed.
Taking down rain water pipe 110mm/75mm bore incl all fittings, head shoes, bends swan necks etc incl cleaning or re-fixing or removal to store(measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed.
S&F 110 mm bore UPVC (SWR) pipes Type 'A', single socketed, in any length with rubber ring joints, laid in trenches or in floor or fixed to walls complete all as specified and as directed.
S&F 110mm bore UPVC (SWR) Bends/Tee type ‘A’ (any radius) complete all as specified and as directed.
S&F holder bat clamps 100mm bore out of 50mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed.
All as per Srl item No.63 above, but 75mm bore complete all as specified and as directed.
Demolition of cement concrete (un reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed.
M&L for cement concrete 1:3:6, type C-2, using 40mm graded stone aggregate in plinth protection, 75 mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8, type D-2, using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
S&F 100mm bore UPVC (SWR) branch piece, single (single Y) equal or unequal provided with oval access doors complete all as specified and as directed.
M&L for removing/demolition of existing CI trap of WC/Bathroom/kitchen and filling the opening with rod and concreting and finishing the existing surface/sunken floor and create a opening in existing wall and connect with existing sewage/drainage line complete all as specified and as directed.
Note :- The contract sum shall be after deducting the amount of Credit shown in Sch of Credit of this Tender.
YP INFRA
P R Constructions
Chaudhary Constructions
M/S Parmod Johar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .