Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC 361 D SHAKTI NAGAR NEAR KHAN DAIRY INDIRA NAGAR LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.2 L+₹1.6 L (5.48%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.9 L+₹2.2 L (7.59%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹33.9 L+₹4.3 L (14.6%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹35.4 L+₹5.8 L (19.7%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
29 Apr 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPECIAL REPAIR/REPLACEMENT OF OVERHEAD CONDUCTOR TO UNDERGROUND CABLE POORVA ENCLAVE, RCS SCHOOL, SHOPPING COMPLEX AT 11 GRRC, PROVN OF 01 X WAITING SPACE FOR OFFICERS WAITING AT ADM BLOCK AT CH CC AND PROVN OF BARBED WIRE FENCING WITH ANGLE IRON
2024_MES_648993_1
GE/EM/LKO/EXT(ELECT)/T-10 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹88,000
Yes
15 Jun 2024
2 Apr 2024
1 May 2024
2 Apr 2024
29 Apr 2024
16 Apr 2024
Amount
Taking down existing ACSR conductor including disconnection after taking proper written shut down from HT/ LT OH line all as specified and directed by Engr-in-Charge.
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed by Engr-in-Charge.
Dismantling of GI wire any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing LT/HT insulators any types and any size all as specified and directed by Engr-in-Charge
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, / laying of pipe / cable etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft loose soil complete.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removing excavated soil n.exc 50 m and depositing where directed at a level n.exc 1.5 m above from the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engr-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L for laying well burnt old size bricks, sub class "B" bricks, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Deployment of manpower / tools for Boring / drilling (Horizontally) manually / mechanically under existing road max 10 M in width) suitable for passing tubing 40 to 100 mm bore complete all as specified and directed by Engineer in Charge
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4.0 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and including MS Clamps, nuts, bolts, washers complete all as specified and directed. Note- Excavation, earth works, and sand cushioning, protection bricks / tiles / blocks and pipe shall be measured and paid seprately.
All as per item No. 11 above but LT UG cable of size 16 Sqmm 4 core.
All as per item No. 11 above but LT UG cable of size 35 Sqmm 3.5 core.
All as per item No. 11 above but LT UG cable of size 50 Sqmm 3.5 core.
All as per item No. 11 above but LT UG cable of size 70 Sqmm 3.5 core.
All as per item No. 11 above but LT UG cable of size 95 Sqmm 3.5 core.
All as per item No. 11 above but LT UG cable of size 240 Sqmm 3.5 core.
M&L for 4 mm dia galvanised iron wire as earth continuity conductor or main earthing lead laying in trenches or fixed to pole complete all as specified & directed.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core, 25 to 50 Sqmm XLPE armoured aluminium conductor cable. Note:- Excavation and earth work, extra cable if required will be measured & paid separately under respective items of this BOQ.
S&F Cable jointing kit for straight through joint, heat shrink type joint for 1100 V grade cable complete with jointing material and accessories suitable for 3.5 core, 70 to 95 Sqmm XLPE armoured aluminium conductor cable. Note:- Excavation and earth work, extra cable if required will be measured & paid separately under respective items of this BOQ.
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for cutting of PCC / Hard standing / road etc not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using PCC (1:3:6) type C-1 complete all as specified and directed .
S&F in replacement weather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimension 333 mm x 233 mm x 120 mm, inside dimension 300 mm x 200 mm x 105 mm, single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelain insulator including S&F MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing / painting of danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 6mm thick of size 600 x 600 mm buried directly and vertically in ground with top edge of the plate not less than 2.25 mtr from GL, connected with galvanised iron strip 32 x 6 mm all as shown in Plate No-3, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx50mm with handle for lifting made out of 8mm dia MS rod, funnel, wire mesh, 50 mm dia light grade GI tubing for protection of GI Strip 32x6mm, charcoal and salt in alternate 150mm thick layers around GI earth plate, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion
Supply, installing, testing and commissioning in replacement factory made, tested , CPRI approved powder coated Timer panel board (Dimension of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm), cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet, 40 x 40 x 6 mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50 x 50 x 6 mm duly coated with Zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos Note - Platform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crushed stone ,15 cm thick in foundation, brick work in CM 1:6 with sub class B old size bricks ,rendering 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel. The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
Supply, installing, testing and commissioning in replacement factory made, tested, CPRI approved powder coated LT Panel board (Dimension of Cubical / enclosure not less than 1400 mm x 1200 mm x 500 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50 x 50 x 6mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm duly coated with Zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 315 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 300/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 25 KA thermal magnetic release - 02 Nos
All as per item No 29 above but comprising with following:- Size 1200mmx900mmx600mm (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole,63Amps 50 Hz 415 Volts,25 KA thermal magnetic release -05 nos.
All as per item No 29 above but comprising with following:- Size 1200mmx800mmx600mm (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole,160 Amps 50 Hz 415 Volts,25 KA thermal magnetic release -02 nos. (i) MCCB 4 pole,100 Amps 50 Hz 415 Volts,25 KA thermal magnetic release -01 nos.
All as per item No 29 above but comprising with following:- Size 1900mmx1200mmx900mm (a) Incoming :- (i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Outgoing (i) MCCB 4 pole,100Amps 50 Hz 415 Volts,25 KA thermal magnetic release -01 nos. (ii) MCCB 4 pole,63Amps 50 Hz 415 Volts,25 KA thermal magnetic release -05 nos.
M&L in replacement out door type busbar panel board (Dimension of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Volts, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Material & Labour for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable of green colour as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size with laminated white top sheet cover of 3.00 mm thick complete.
All as per Item No 35 above but for one 5 pin 5 Amp socket outlet point on independent board.
All as per Item No 35 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
S&F Polycarbonate switch piano flush type, SP,5/6 Amps, one way complete all as specified &directed
S&F Polycarbonate switch piano flush type, SP, 16/20 Amps, one way complete all as specified &directed
S&F Polycarbonate socket out let 2 in 1 socket 5 pin, (6 Amps) flush type controlled by one switch, complete all as specified &directed
S&F Polycarbonate socket out let 6 pin, 20 Amps complete all as specified. & directed
S&F ceiling rose polycarbonate body surface type three terminal complete as directed.
S&F epoxy powder coated distribution box Double door type SPN 4 way, with 200 amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door all as specified and directed.
S&F in repair MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in repair MCB, single pole & neutral 40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
Supply and fix wall / surface mounting luminaires integrated LED Batten (4 feet) 20 W, 6500 K, 230V , system efficiency not les than 100 lumens / watt, with extruded aluminium housing with frosted PMMA / PC diffuser & integrated electronic driver fixed in position and connecting with ceiling rose complete all as per specified and directed by Engr-in-charge.
Supply & fix ceiling fan 1200 mm sweep, BLDC copper wound motor, AC single phase, 230 volts, white colour complete with fan blade, down rod, canopy and Provn of connection with three core flexible copper wire cable of size 1.50 Sqmm from ceiling rose to fan, writing of MES Nos as approved size of letter complete all as specified and directed.
Supply, installing, commissioning and testing , non-inverter type split Air Conditioner of capacity 1.5 TR with inbuilt ioniser and plasma filter for better air quality, front panel display, wireless LCD remote control, precoated aluminium fins, 5 star rated, electric driven, suitable for working on 230 volts, single phase, 50 Hz supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall complete, all as specified and directed.
Supply and fix recess type 36 watt LED light fittings of size 600 mm x 600 mm, made of CRCA powder quoted housing, fully covered by PMMA acrylic Lumio Diffuser, LED Used shall be SMD type, fixed in 15 feet hight false ceiling of any pattern / material by cutting opening of suitable size, including electrical connection all as specified and directed.
M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, using bricks of size 230 mm x 110 mm x 70 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
S&F 0.50 mm thick Pre- painted Galvalume aluminium zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall or roof, fixed with self tapping screws as specified and as directed by Engineer-in-charge
S&F 0.50 mm thick Pre- painted Galvalume aluminium zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof ridge / cladding to wall or roof, fixed with self tapping screws as specified and as directed by Engineer-in-charge
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for RCC 1:2:4 type B1, using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels & similar RCC works all as specified and directed.
S&F mild steel work as in hold fasts and similar articles conforming to Fe.290.Gde-E-165
M&L for Cement concrete type D2 1:4:8 (using 40mm graded stone aggregate's) as in foundations, filling and mass concrete all as specified and directed.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete wall surfaces including mixing only water proofing compound as per manufacturers instruction and finishing the surface even and smooth without using extra cement complete all as specified. Note:- Waterproofing compound will be measured and paid separately.
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on brick work or cement concrete wall surfaces including finishing the surface even and smooth without using extra cement complete all as specified.
Supply only integral WPC of approved quality
M&L for preparation of new plastered surface of walls and applying two coats exterior emulsion weather coat paint of make Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) over one coat primer with 2 mm thick cement base wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of primer over and including 2 mm thick cement base wall care putty complete all as specified and directed by Engineer-in-charge.
M&L for 40 mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) Damp proof course to horizontal or vertical surfaces including necessary formwork and including mixing only water proofing compound as per manufacturers instruction complete Note:- Waterproofing compound will be measured and paid separately.
M&L for 75 mm thick cement concrete 1:4:8, type D-2, using 40 mm graded stone aggregate, as in Sub base / path / flooring complete all as specified and as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil
S&F powder coated aluminium extruded sections (conforming to IS) (minimum thickness of powder coating 50 micron) three track sliding window shutter with frames comprising series-C (20 mm) , duly fitted with neoprene beading, glazing clips, locking devices, heat absorbing glass 4.8 mm thickness (in 2 shutters) and with SS wire cloth of 0.46 mm nominal dia of wire and average width of aperture 1.4mm (in one shutter) complete all as specified and directed.
S&F Powder coated Aluminium sections (conforming to IS) door frames with single / double leaf shutters complete duly fitted with neoprene rubber beading, heat absorbing glass panes 4.8 mm nominal thickness, Alu anodised with rubber shoe floor door stoppers- 2 Nos, floor spring 2 Nos, Handle 2 Nos in each shutter, Aluminium tower 1 Nos in each shutter and necessary locking arrangement with mortice lock with duplicate key complete all as specified and as directed (Note:- (i) floor spring measured and paid separately.
Supply & fixing in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of mild steel heavy duty fixed.
M&L for seamless ceiling comprising of Gypsum Board 12 mm thick in ceiling fixed with screw or as per manufacturers instructions, with necessary jointing and taping, and applying two coat oil bound distemper over one coat primer fixed over and including Gl frame work comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, including applying 2 coat distemper oil emulsion over 2 mm thick cement base putty complete all as specified & directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete.
S&F Mild stee bars (TMT bars) 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire [annealed] not less than 0.9 mm dia or securing with clips.
Use & waste Form work to sides and soffits of floor or roof beams, lintels cantilever etc for rough finished surface complete all as directed.
M & L for 75 mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection, surfaces finished even and smooth without using extra cement all complete all as directed by Engineer -in-charge.
M&L for Hardcore of gauge n exc. 63 mm, of broken bricks, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for double charged colour vitrified ceramic tiles 10 mm thick (square) polished, area of each tiles n.exc 0.36 sqm in floors etc laid over and including 15 mm thick cement screed base in CM 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete.
Demolition of brickwork or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including sides and soffits of beams, fascias, parapets etc and applying two coats of cement base paint over one coat of primer, colour and tint as ordered, complete all as specified and directed by Engineer-in-Charge.
M&L plain cement concrete cast 1:2:4 type B1 using 20.00 mm graded stone aggregate as in copings, PCC for fixing of post and other similar work and the like including weathering, slightly rounded or chamfered angles and throating etc including use & waste form work all as specified and directed
S&F Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, as in repair etc as directed (each line of wire to be measured)
M&L for mild steel work in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
abhinav enterprises
M K Engineers and Contractors
FUTURE Inc.
OM NAMAH SHIVAY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .