Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹11.5 L+₹35,975 (3.24%)Rejected-AOC KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹11.7 L+₹60,300 (5.43%)Rejected-AOC 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹14.7 L+₹3.5 L (31.9%)Rejected-AOC | L4 | Rejected-AOC L4 QUOTED | |
| 5 | L5₹14.8 L+₹3.7 L (33.1%)Rejected-AOC | L5 | Rejected-AOC L5 QUOTED |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
28 Oct 2019, 6:00 pmClosed
GE (AF) SRINAGAR
GE (AF) SRINAGAR,AIR FORCE STATION,SRINAGAR-190007
REPAIR/REPLACEMENT OF PERIMETER SECURITY LIGHTS WITH LED LIGHTS AND OTHER MISC WORKS AT AIR FORCE STATION SRINAGAR
2019_MES_287728_1
GE(AF)-27/2019-20
Open Tender
Street Lighting
Item Rate
180 days
SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF SRINAGAR
₹30,000
Yes
27 Jan 2020
7 Oct 2019
31 Oct 2019
7 Oct 2019
28 Oct 2019
21 Oct 2019
7 Oct 2019 - 14 Oct 2019
Amount
Taking down unserviceable light fiting (HPSV/HPMV/HPMH/LED/Aviation lights from Pole/wall or any other location any capacity ,any height, any situation, repairs to the extent by removing connections from the system, checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location or other location (as directed) including replacement of three core copper cable of suitable size and tesing complete all as specified and directed by Engineer-in-Charge. Note : (a) Spares required for repair (except connection cable) shall be measured and paid separately as supply only items here-in-after 2 to 13 and the cost of connection cable shall be deemed to be included in the quoted rates.(b) The contractor shall provide all type and safety equipment to electrician (c) In case any accident/injury of any person deputed by contractor, contractor shall be held responsible for setting all claims/compensation. (d) Contractor to provide one vehicle and ladder as required at site for 24 hours for repair of perimeter light/security light with one electrician and two helpers
Supply only Open construction copper wound ballasts 250 Watts suitable for HPSV/MH fitting etc of existing make and type complete all as specified and directed Engineer-in-Charge.
Supply only Open construction copper wound ballasts 150 Watts suitable for HPSV/MH light fitting etc of existing make and type complete all as specified and directed Engineer-in-Charge.
Supply only 250 watt HPSV/MH Lamps tubular type/double ended type etc of existing make and type complete all as specified and directed Engineer-in-Charge.
Supply only 150 watt HPSV/MH Lamps tubular type/double ended type etc of existing make and type complete all as specified and directed Engineer-in-Charge.
Supply only Ignitor/capacitor suitable for HPSV/MH fittings of capacity 150 to 250 watt etc of existing make and type complete all as specified and directed Engineer-in-Charge.
Supply only porcelain lamp holder thread/pin type suitable for HPSV/MH lamps 150 to 250 watt fittings complete all as specified and directed Engineer-in-Charge. Make: Havells/HPL/C&S
Supply only LED lamp 40 watt suitable B-22/E27 type lument out put 3400 lm color temp 6500K etc complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply only LED driver of capcity 15 Watt suitable for 240 volts complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply only LED driver of capcity 30 Watt suitable for 240 volts complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply only LED driver of capcity 50/60 Watt suitable for 240 volts complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply only LED driver of capcity 100 Watt suitable for 240 volts complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply only LED driver of capcity 150 Watt suitable for 240 volts complete all as specified and directed Engineer-in-Charge. Make- Crompton/ Philips/Wippro
Supply and fixing in repairs MCB SP 16 Amp 240 V and rupturing capacity 10 KA complete all as specified and directed Engineer-in-Charge. Make-Legrand/Havells/Schinder
S&F SMD LED flood light with pressure die cast aluminium housing complete with all accessores of capacity 60 watt complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LF19-711-060-57-XX or equivalent in performance in Crompton/ Philips as approved by GE
S&F SMD LED flood light with pressure die cast aluminium housing complete with all accessores of capacity 100 watt complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LF20-122-060-57-G2 or equivalent in performance in Crompton/ Philips as approved by GE
S&F SMD LED flood light with pressure die cast aluminium housing complete with all accessores of capacity 150 watt complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LF20-192-060-57-G2 or equivalent in performance in Crompton/ Philips as approved by GE
S&F powder coated pressure die cast aluminium SMD LED street light with heat resistance tounghned glass with lens and dimming driver (1V-10V DC input control voltage for 10% to 100% dimming of capacity 70 watt etc complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LR02-781-XXX-57-G2 or equivalent in performance in Crompton/ Philips as approved by GE
S&F powder coated pressure die cast aluminium SMD LED street light with heat resistance tounghned glass with lens and dimming driver (1V-10V DC indput control voltage for 10% to 100% dimming of capacity 100 watt etc complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LR02-112-XXX-57-G2 or equivalent in performance in Crompton/ Philips as approved by GE
S&F decorative post top lantern 60Watt for 360 C indirect light resistant to impact and corrosion, Glare free and better uniformity IP-65 protection miliky version with all accessories complete all as specified and directed Engineer-in-Charge. Make Wipro Model No LP07-671-XXX-57-CL or equivalent in performance in Crompton/ Philips as approved by GE
Excavation in trenches n.exc 1.5 M wide and n.exc 1.5 M depth and getting out for laying of cable etc in any type of soil complete all as specified and directed Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing of excavated soil to a distance n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed Engineer-in-Charge.
M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc complete as specified and directed.
M&L for laying of bricks well burnt sub class B (old pattern) laid flat for cable protection width equal to the length of bricks complete all as specified and directed
Supply, laying, jointing, testing in repair XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, conforming to IS 1554 Part I / ISI marked, including cable glands , cable lugs etc as suitable to the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc complete of following sizes OF Make : NICCO/HAVELLS/PLAZA/KALINGA :-
6 sqmm 2 core
10 Sqmm 2 core
16 sqmm 4 core
25 sqmm 4 core
35 sqmm 3.5 core
Supply and fixing in repair galvanised iron tube ` light grade' for protection of copper strip at wall and duct/road/trench for 32 mm dia of pipe complete all as specified and directed Engineer-in-Charge. Make: JINDAL/BST/PRAKASH SURYA
Supply and fixing in repairs Junction box factory made of mild steel 1.6 mm thick of size 300 mm x 250 x 200 mm including 04 Nos alunimum bus bar of 3 mm thick duly fitted on the suitable insulator with fixing arrangement and including SP MCB 6 Amps clamped with pole/fixed on wall and taking out old unserviceable boxes complete all as specified and directed by the Engineer-In-Charge. Make: L&T/HPL/Sintex/Havells/Hensal
Supply and fixing in repairs repairs for two run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay copper conductor and drawn through pole from junction box to street light connection, complete all as specified and directed by Engr-in-Charge. Make: HAVELLS/FINOLEX/GLOSTER/PLAZA
Supply and fixing in repairs 10 sqmm twin core insulated screened PVC bedded un armoured service wire with aluminium conductor complete all as per specified and directed by Engr-in-charge. Make: HAVELLS/FINOLEX/GLOSTER/PLAZA
Supply & fixing in replacement GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer and fixed to pole / walls etc complete all as specified. Make of pipe: JINDAL/BST/PRAKASH SURYA
S&F sheet metal enclosure for DB SPN 2 ways, 240 V complete fixed properly on pole/wall with suitable size MS flat iron with nut bolts washer etc complete as specified and directed. Make : Legrand /Schiender/Seimens
Supply,install,testing and commissioning of out door FPB cubical factory made CPRI approved/ tested , dust and vermin proof fabricated to 3.0 mm thick CRCA sheet and mounted on angle iron and tee section frame of size 35x30x6mm and double door front/rear opening and locking arrangment floor mounted, bus bar chember with 100 amps capacity aluminium bus bar with insulated slips fixed on post insulator inclduing painting with powder coated as specified and pre-wired with suitable size pvc insulated sheathed copper conducotr cable , cable gland, incl earth & pcc works complete in all respects and including the following :- (a) MCCB 4 pole 100 Amp 36 KA-01 Nos (b) Digital voltmeter with slector switch (0-500)-01 No (c) Digital Ammeter with suitable capacity CTs/slector switch-01No (d) indicator lamp set of 03 -01 Set (e) Digital time switch suitable for 24 hours running 415V-02Nos (f) Power contractor suitable 40 Amps 415 volts -02 Nos
M&L for painting of steel tubular poles approximately 7/7.50 meter above GL in height including cross arms and bracings with two coat of aluminium paint painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint including numbering of the pole in yellow and black paint in circle of 10cm dia complete all as specified and directed.
Note for all items: Make of components replacement if not specifically mentioned in the relevant item same shall be of the existing make.
M/S RATHER CONSTRUCTION CO
MIR AND CO
M/S M.Y Enterprises
M/S ABDUL KARIM RATHER
M/S Vijay Punj Constructions
M/S Sky Engineers
M/S Abdul Ahad Rather
M/s Jaipal Associates
M/S GHULAM HASSAN AND SONS
M/S Thakur & Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .