Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹39.3 L+₹2.3 L (6.27%)Rejected-Finance 18 KUSHAL LAYOUT 1ST CROSS KAGGADASAPURA CV RAMAN NAGAR POST BENGALURU 560093 | BENGALURU | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-Finance Being Not the Lowest Tenderer | |
| 3 | L3₹39.8 L+₹2.8 L (7.45%)Rejected-Finance E 27 CWE WELLINGTON | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L3 | Rejected-Finance Being Not the Lowest Tenderer | |
| 4 | L4₹41.4 L+₹4.4 L (12.0%)Rejected-Finance IV 54 DIVYA COMPLEX RAJEEV NAGAR BOY S COMPANY ARUVANKADU THE NILGIRIS 643202 | ARUVANKADU | THE NILGIRIS | TAMIL NADU | 643202 | L4 | Rejected-Finance Being Not the Lowest Tenderer | |
| 5 | L5₹41.7 L+₹4.7 L (12.7%)Rejected-Finance E 37 CWE AF SOUTH BANGALORE A I A II B I | BENGALURU URBAN | KARNATAKA | 560001 | L5 | Rejected-Finance Being Not the Lowest Tenderer |
| Sl No | Description | Qty | Unit | SEMBA ELECTRICALS L5 | m/s prabakaran L4 | UNIQUE INDIA CONSTRUCTIONS L3 | KRA Constructions L1 | RISHAN INFRA ENTERPRISES L6 | TECKXPERT ENTERPRISES L2 | VENKATESH L8 | MSR ENTERPRISES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified and directed. | 100 | Sqm | 80 ₹8,000 | 107.9 ₹10,790 | 120 ₹12,000 | 105.09 ₹10,509 | 40 ₹4,000 | 95 ₹9,500 | 107.9 ₹10,790 | 12 ₹1,200 Lowest |
| 2.00 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed. | 16.04 | Sqm | 80 ₹1,283.2 | 65.32 ₹1,047.73 | 80 ₹1,283.2 | 60.42 ₹969.14 | 40 ₹641.6 Lowest | 55 ₹882.2 | 65.32 ₹1,047.73 | 120 ₹1,924.8 |
| 3.00 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in hard/ dense soil (exceeding 30cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, all as specified and directed. | 49 | CUM | 450 ₹22,050 | 195.51 ₹9,579.99 | 195.51 ₹9,579.99 | 188.22 ₹9,222.78 | 400 ₹19,600 | 160 ₹7,840 Lowest | 195.51 ₹9,579.99 | 200 ₹9,800 |
| 4.00 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in hard/ dense soil (exceeding 1.5cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, all as specified and directed. | 30 | CUM | 450 ₹13,500 | 235 ₹7,050 | 235 ₹7,050 | 225.92 ₹6,777.6 | 400 ₹12,000 | 200 ₹6,000 Lowest | 235 ₹7,050 | 200 ₹6,000 Lowest |
| 5.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/ dense soil complete all as specified and directed. | 117.79 | CUM | 150 ₹17,669.1 | 162 ₹19,082.63 | 162 ₹19,082.63 | 157 ₹18,493.66 | 150 ₹17,669.1 | 145 ₹17,080.13 Lowest | 162 ₹19,082.63 | 150 ₹17,669.1 |
| 6.00 | Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed. | 36.73 | CUM | 250 ₹9,182.5 | 360 ₹13,222.8 | 360 ₹13,222.8 | 361 ₹13,259.53 | 350 ₹12,855.5 | 330 ₹12,120.9 | 360 ₹13,222.8 | 200 ₹7,346 Lowest |
| 7.00 | Plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concreting, complete all as specified and directed. | 15.43 | CUM | 5,000 ₹77,150 | 6,295 ₹97,131.85 | 6,295 ₹97,131.85 | 6,195 ₹95,588.85 | 4,000 ₹61,720 | 5,500 ₹84,865 | 6,295 ₹97,131.85 | 3,500 ₹54,005 Lowest |
| 8.00 | Reinforced cement concrete (Design Mix M-25) using 20mm graded stone agregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete all as specified and directed. | 14 | CUM | 9,000 ₹1,26,000 | 8,670 ₹1,21,380 | 9,000 ₹1,26,000 | 8,633.26 ₹1,20,865.64 | 8,000 ₹1,12,000 | 7,600 ₹1,06,400 | 8,670 ₹1,21,380 | 6,500 ₹91,000 Lowest |
| 9.00 | Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed. | 60 | SQM | 550 ₹33,000 | 357 ₹21,420 | 600 ₹36,000 | 357.89 ₹21,473.4 | 500 ₹30,000 | 315 ₹18,900 Lowest | 357 ₹21,420 | 450 ₹27,000 |
| 10.00 | Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts etc all as specified and directed. | 8.95 | CUM | 9,000 ₹80,550 | 9,810 ₹87,799.5 | 9,000 ₹80,550 | 9,774.5 ₹87,481.78 | 8,000 ₹71,600 | 8,700 ₹77,865 | 9,810 ₹87,799.5 | 6,500 ₹58,175 Lowest |
Tender Value
₹37.3 L
EMD Value
₹74,600
Closing Date
28 Nov 2025, 6:00 pmClosed
GE WELLINGTON
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
PROVN OF 02 X URINAL POT AND 01 X TOILET AT SUP PT ASC AND GUARD REST ROOM WITH TOILET WITH ELEVATED TOWER NEAR REAR GATE AT 35 FD REGT AND OF FENCING VIEW CUTTER AROUND OFFICERS MARRIED ACCOMMODAITON AT COIMBATORE AND MADUKKARAI MIL AREA UNDER GE WE
2025_MES_738860_1
8148/E8
Open Tender
Civil Works
Item Rate
120 days
Coimbatore
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE WELLINGTON
₹74,600
Yes
16 Feb 2026
7 Nov 2025
1 Dec 2025
8 Nov 2025
28 Nov 2025
22 Nov 2025
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in hard/ dense soil (exceeding 30cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, all as specified and directed.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas in hard/ dense soil (exceeding 1.5cm in depth, 1.5m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/ dense soil complete all as specified and directed.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concreting, complete all as specified and directed.
Reinforced cement concrete (Design Mix M-25) using 20mm graded stone agregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, base of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter flat surface rough finished complete all as specified and directed.
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate in columns, pillars, piers, posts and struts etc all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface of concrete complete all as specified and directed.
Reinforced cement concrete M-25 design mix Type B1, 1:2:4 using 20 mm graded stone aggregate for Beams, cantilevers, bressumers, lintels over 1.5m span, complete all as specified and directed.
Use and waste of steel Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Fair finished surfaces of concrete flat complete all as speicified and directed.
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick column, beam etc (Horizontal or sloping) rough finished all as specified and directed.
Reinforced cement concrete M-25 design mix using 20 mm graded stone aggregate for Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks upto 1500 litres etc compelte all as specified and directed.
Use and waste of Formwork to staircases with sloping or stepped soffits including risers and stringers ( excluding landing) complete all as speicified and directed.
Use and waste of form work to edges of concrete flats, treads, breaks in floor, window cills, concrete railing, openings in concrete walls, floor and roof not exceeding 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide all as specified and directed.
Reinforced cement concrete M-25 Design mix using 20mm graded stone aggregate in Chajjas complete all as specified and as directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges,etc compelte all as specified and as directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
Mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips in stirrups, spacers, binders, etc complete all as specified and directed.
Steel reinforcement for concrete with Mild steel TMT bars 5mm dia and over cut and upto and including 10mm dia stirrups, spacers and binders, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips all as specified and directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished fair with WPC @200 ml per bag of cement etc curved well at junction of wall & slab before laying of APP membrane complete all as directed. Note: WPC shall be measured and paid separately.
Roof treatment with following specification completely, complete all as specified and as directed by Engineer-in-Charge :- (i) Applying evenly a tack coat of bitumen primer @ 1.2 kg/ sqm. (ii) Laying APP modified membrane weighting not less than 3 to 4 kg/sqm in 100 mm over laps both longitudinally and transversally and overlaps to be sealed by torch, membrane shall be taken upto the thickness of slab/front fascia. (iii) Cleaning & preparing the surfaces and finally painted at the top with a coat of bituminous aluminium paint all as specified and as directed
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exceeding 15 cm but not exceeding 30 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc.
Plain Cement Concrete (1:2:4) type B0 using 12.5mm graded stone aggregate as in coving,coping and haunching and bed blocks for hold fast including use and waste of form work all as specified and directed.
Moorum / Red bajri filling in floors or pavings laid in layers not exceeding 15cm, spread, levelled and rammed including watering all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface all as specified and directed.
Brickwork with flyash bricks, straight or curved on plan exceeding 6m mean radius, built in modular bricks in cement mortar 1:6 Complete all as specified and directed.
Brick work flyash bricks, straight or curved on plan to any radius in half brick thick wall built in modular bricks in cement mortar 1:6 Complete all as specified and directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished fair and even and smooth with out using extra cement all as directed.
External rendering 15mm thick in cement mortar 1:4 with on fair faces of brick work or concrete surfaces finished even and fair with water proofing compound complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately
Material and labour for rendering to ceiling in 5mm thick on fair faces concrete surface in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed.
Supply only water proofing compound all as specified and directed.
100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of flooring / hard standing complete all as specified and directed.
25mm thick plain cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in flooring finished even and smooth using extra cement all as specified and directed.
Non skid coloured Ceramic tiles 7 to 8mm thick (square/ rectangular) polished, area of each tiles but exceeding 0.18 sqm but not exceeding 0.38Sqm infloors etc set and jointed in cement slurry and pointed in white or coloured cement to match over including 15mm thick screed bed in cement mortar 1:4 all as specified and as directed.
All as per item No 38 here in before, but on vertical surfaces including 10mm thick cement mortar 1:3 as in baking coat of dado/ skirting all as specified and as directed.
Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match the surface over and including 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4 complete all as specified and as directed.
Coloured Glazed ceramic tiles in vertical surfaces 450mm x 350 x 7mm / 350mm x 250mm x 7mm to 8mm thick as in dados, skirting, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigments to match the surface, on including 10mm thick rendering in cement mortar 1:3 as backing coat for fixing dado tiles complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing all as specified and directed.
Factory made solid panel PVC door shutter 30mm (Stile) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed.
Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, lock strike plate etc, and filling with PCC complete all as specified and directed.
Second class HW plain, framed, panelled shutters 30mm thick (any No of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkats all as specified and directed.
30mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, edges of framing, divided in to squares with plain chamfered or rounded fitted with cut and mitred beads for securing glass/ gauze all as specified and directed. Note: Glazing and gauze will be measured and paid separately.
Steel windows with side hung shutters incl projecting type hinges with steel handle and steel pegs stay complete with glazing bars dovetailed or welded with glazing bars complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle complete with out glazing bars dovetailed or welded as fly proof shutters complete all as specified and directed.
Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Steel Ventilators with top hung shutters including hinges, steel peg stay, fixed including welding complete all as specified and as directed (Box type frame and shutters) compelte all as specified and directed.
Applying oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed.
Applying three coats of white wash on newly plastered ceiling surfaces including preparation complete all as specified and as directed
Applying two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces all as specified and directed.
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of new wood surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
4mm thick figured glass,pin head type and glazing with oil putty in squares not exceeding 0.5sqm in each pane all as specified and as directed.
Chimney bars (straight or camber) bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in steel frames, L or T section supports for shelves etc, including welding and similar articles conforming to Fe 290 Gde E-165
Aluminium anodised, barrel tower bolts of extruded section 200 mm long and fixed complete all as specified and directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Butt hinge, 100 mm long medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Aluminium handles, cast type anodised, 150 mm long complete all as specified and directed.
Treating ends of posts, back of chowkats etc., area tarred exceeding 0.10sqm but not exceeding 0.50sqm each including preparation of the surfaces and treated with coal tar or black biuminous paint all as specified and as directed
Sanding newly tarred surfaces with clean sand sharp sand complete all as specified and as directed.
Vitreous China, wash down water closet pan (Pedestal pattern), white including supply and fix of plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
PVC valveless low level, syphonic action type, flushing cistern, 10 litres capacity, white with inlet, ball valve, float and handle, PVC flush pipe, brackets etc complete all as specified and as directed
Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 750mm all as specified and directed.
Bib taps of cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed 15mm bore, fixed in repairs all as specified and directed.
Pillar taps, 15mm, fancy type, cast copper alloy with capsten heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed
Stop / angle valves, 15mm dia, fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and directed.
Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges including suitable bracket complete all as specified and as directed.
20mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
15mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Rotational moulded polyethylene water storage tank, ISI marked three layer (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified and directed.
Ball valve high pressure 20mm dia of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, minimum weight 210 gms, complete all as specified and directed
20mm dia nipple of PTMT, suitable for HDPE water tank min weight 45 gms complete all as specified and directed.
Harrison rails of anodised aluminium alloy fixing with brackets, stops, rollers etc all as specified and as directed.
Vitreous China wash hand basin of size 550 x 400mm white flat back including 32mm dia waste coupling / fittings, brass, chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, including brackets, PVC waste pipe, including cutting for and pinning in ends of brackets or errecting stand, complete all as specified and directed.
PVC (SWR) gully traps 125 x 110 mm, setting and jointing with solvent cement including concrete pedestal etc complete all as specified and as directed
110mm dia PVC (SWR) junction single, (Single T) equal or unequal, fitted with oval access door all as specified and directed.
110mm bore PVC (SWR) bends any radius all as specified and directed.
PVC (SWR) bends any radius, 75mm bore with oval access door complete all as specified and directed.
PVC (SWR) vent cowl of size 110mm bore dia complete all as specified and as directed
PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches or in floors, completed all as specified and directed.
PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed
Anti termite treatment to backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contac with backfill to be measured) all as specified and directed.
Anti Termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
Anti Termite treatment to soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
Anti Termite treatment to soil along with external perimeter of building at the rate of 2.25 litres of emulsion per square meter of perimeter wall complete all as specified and directed.
75mm thick Plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in plinth protection laid and finished in bays not exceeding 2sqm in plain and filling the joints with mastic bitumen complete all as specified and directed.
Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters, walk ways, railing, frame work of water tanks and and simialr work conforming to Fe290 Gde E-165 all as specified and directed.
Machine cut polished kota stone slab flooring/ cills 20-25mm thick over and including 15mm thick cement screed base in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish, complete all as specified and directed.
Machine cut polished kota stone slab 20-25mm thick over cement screed base as in riser, skirting, dado etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing 10mm thick cement plaster as backing coat in cement mortar 1:3 in skirting / dados complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr deep for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth , and gertting out in hard and dense of soil complete all as specified and directed.
Galvanised steel tubing 25mm bore medium grade with screwed and socket joints together with all galvanised steel fittings such as sockets, elbows, bends,tees, reducers, short pieces, unions, caps, plugs etc. laid in trenches including connection, cutting, screwing, drilling etc all as specified and directed
Gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe including fixed in repairs of size 25mm dia all as specified and directed.
Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed of dia 25mm all as specified and directed.
Brick work with sub class ‘B’ bricks, burnt clay bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces or on top of roof slab in cement mortar 1:4 and finished fair and even and smooth with out using extra cement mixed with water proofing compound all as directed. Note: WPC shall be measured and paid separately all as specified and directed.
Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in cement mortar 1:4 including necessary form work complete all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Concrete bed to drain pipes including packing under and haunching against the sides of the pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded aggregate for 100 mm bore pipe all as specified and directed.
Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in forming channel benching inside manhole (1/2 or 3/4 section) smooth finished and benching as required for 110mm dia drain in manholes all as specified and directed.
Precast RCC hume pipe septic tank for 25 users and of dia 1.20m, length 2.40m including transportation complete all as specified and directed
Fixing of Septic tank in position using crane complete all as specified and directed
900mm dia and 1.50m depth precast soakage well including transportation complete all as specified and as directed
Supply only liquid water proofing compound for waterproof plastering complete all as specified and directed.
Powder coated anodised aluminium frame for doors, windows, sliding windows, ventilators with one or more rebates including joining cleat forfixing etc. complete all as specified and as directed. Note: Minimum thickness of powder coating shall be 50 micron
Ground or obscured or frosted sheet glass 3 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.50 sqm in each pane all as specified and directed.
Butt hinges extruded Aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21, with MS hinge pin 100mm size all as specified and directed.
Aluminum handles, fabricated type, anodised extruded section 150mm long all as specified and directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Precast reinforced cement concrete type B1, 1:2:4 using 20mm graded stone aggregate set in cement mortar 1:6 in landings for WHB, cover slab (for manholes etc chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces all as specified and directed. Note: Reinforcement shall be measured and paid separately.
Mild steel flate iron of any size for hold fast, in frame of shutters conforming to Fe-290 Gde-165 all as specified and directed.
PVC (SWR) bends any radius, 110 mm bore with oval access door complete all as specified and directed.
PVC (SWR) vent cowl of size 75mm bore dia complete all as specified and as directed
Brass chromium plated bottle trap 32 mm for wash basins with inlet and outlet screwd for pipe or connections including necessary packing, union and cap all as specified and directed.
PVC connections 15mm size with CP brass nuts of length 450mm complete all as specified and directed.
Stop valves, 15mm dia of cast copper alloy, screwed down, high pressure, with fancy type, chromium plated ank and Cup (concealed type) with long screwed both ends for unions and fixed complete all as specified and directed.
20mm dia Gunmetal, globe or gate valves (half turn type or wheel type), screwed both ends for iron pipe and fixed complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) three layers of capacity 500 Ltr hoisted and fixed in position with proper inlet and outlet connections all as specified and directed.
Ball brass valves high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule of dia 20 mm all as specified and directed.
Compound girders and stanchions, lattice girders, aerial masts, staging for water tank and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates etc Fe-410-W (Gde E-250) quality B complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gussest plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering doors etc, to be prepared for hanging and sliding with and including either hooks and hinges or steel hnging door fittings and slidding bolt/ tower bolt (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete conferming to gde Fe 410 (Gde E-250) fixed in position all as specified and directed.
Miid Steel sheeting 0.80mm thick plain, black, in ridges, hips, valley gutters, drip and straight flashings (length and grith as fixed) complete all as specified and directed.
Removing excavated soil/ material to a distance exceeeding 250m and not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Vitreous China urinal, half stall type complete including waste pipe, flush pipe and providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement etc, and including connection to flushing pipe and outgoing pipes, 32mm waste fittings, brass, chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly-nuts, flange end bedded in red led cement and other end fixed complete all as specified and directed
Supplay and fix china urinal partition white of size 310 x 710 mm all as specified and as directed.
Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in cement mortar 1:6 type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and directed
Pre-cast cement concrete block masnory with solid block not exceeding 10cm in width and setting in mortar 1:4 type C1 1:3:6 using 20mm graded aggregate complete all as specified and directed
15mm thick rendering on brick wall/ concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement all as specified and directed.
5mm thick rendering in cement mortar 1:4 mixed with water proofing compound over 10 mm thick rendering (backing coat) in cement mortar 1:6 as on (external surfaces) of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid seperately.
Cutting into existing manholes for connecting new drains of 150mm dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150mm dia of pipe complete all as specified and directed.
Damp proof course 40mm thick in cement concrete 1:2:4, type B0 using 12.5mm graded stone aggregate to horizontal or vertical surfaces including necessary formwork mixed with water proofing compound complete all as specified and directed.
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work not exceeding 15 cm in width or girth; including cutting to edges, all mi- tres and stopped ends, etc all as specified and directed
Chequered cement concrete tiles with grey cement and pigments, of size 300x300mmx25mm thick set, jointed and pointed in neat cement slurry in floor including 20 mm thick screed bed in cement mortar 1:4 all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints without grooves (thickness of joints except at sharp curve shall not to more making drainage opening wherever required complete all as specified and directed.
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr deep for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth , and gertting out in soft / loose soil complete all as specified and directed.
Site clearance in soft and loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) each in hard /dense soil not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed
Plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundations filling and mass concrete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws and embedded with cement mortar etc required all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet as in ridge , flasing sheet & gutter etc of 0.45mm to 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering c fixed with self tapping screws all as specified and directed.
Mild Steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe 290 Gde E - 165 complete all as specified and directed.
Plain cement concrete 1:2:4 Type B1 (Using 20mm graded aggregate as in coping Plinth course complete all as specified and as directed
Rendering 10mm thick on fair faces of brick/ concrete surface in cement mortar 1:6 finished even and smooth compelte all as specified and as directed.
Supplying and laying reinforced precast concrete cable cover,Class LV, Type I, flat, with peak size 250mm x 150mm x 40mm all as specified and directed.
Supply and spreading clean dry riddled sand in trenches for cushioning all as specified for cable protection in trenches / ducts complete all as specified and directed. Note: The punned down thickness shall only measured for payment.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area size 16 sq mm 4 core complete all as specified and directed. Note: Excavation, earthwork and cable protection measured separately.
Cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 Mtr and depth 0.6 Mtr all as directed and making good the road/hard using all old / new materials as required at site to match with the existing surface all as specified.
GI tubing light grade 32 mm nominal dia in trench/ road/ pole for cable protection complete all as specified and directed.
Well burnt/ ash bricks sub class ‘B’ as in protection of cable laid dry, flat abutting each other width wise complete all as specified and as directed.
Supply & Laying XLPE insulated, screened, PVC bedded, galvanized steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 6 Sqmm 2 core laid in trenches / ducts/ fixed to wall/ pole/ inside panel/ drawn through pipe including cable glands and terminal sockets cable etc complete all as specified and as directed.
Material and labour for Point wiring complete with 1.5 sqmm (nominal area) FRLS grade PVC insulated, unsheathed stranded copper conductor single core cable 1100 volts grade in and including PVC conduit medium grade in concealed complete with conduit fittings/ accessories including 1.5 sqmm FRLS grade PVC insulated unsheathed stranded copper conductor cable for earth continuity conductor and connected to common earth dolly for One light point controlled by one switch 6Amps SP all as specified and directed. Note: 1. Sunken box/ Cover plate for modular plate for modular switches, sockets etc will be measured and paid separately under relevant items and blank plate required if any will be deemed included in the item rate. 2. Cutting chases in stone masonry wall will be measured and paid separately.
All as per Item No 156 hereinbefore but One fan point controlled by one switch 6 amps all as specified and directed.
All as per Item No 156 hereinbefore but One 3 pin 5A switch socket outlet on independent Board all as specified and directed.
All as per Item No 156 hereinbefore but point wiring complete with 4 sqmm for 3 pin 15 A socket outlet on independent board including 4 sqmm FRLS grade PVC insulated unsheathed multi stranded copper conductor cable for earth continuity conductor all as specified and directed.
Modular switch one way 6A 230V AC 50 HZ SP one module all as specified and directed.
Modular switch one way 16A 230V AC 50 HZ SP one module all as specified and directed.
Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified and directed.
Modular socket outlet 2/3 pin combined 16A 240V AC 50 HZ SP two module all as specified and directed.
MODULAR METAL FLUSH BOX 1/2 module all as specified and directed. Make: Havells/ Legrand/ L&T.
MODULAR METAL FLUSH BOX 3 module all as specified and directed. Make: Havells/ Legrand/ L&T.
MODULAR METAL FLUSH BOX 4 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular Metal Flush Box 6 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate with Frame White cover plate with frame, 2 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate with Frame White cover plate with frame, 3 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate with Frame White cover plate with frame, 4 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Modular White Cover Plate with Frame White cover plate with frame, 6 module all as specified and directed. Make: Havells/ Legrand/ L&T.
Stepped type electronic fan regulator flush type as required all as specified and directed. Make : Anchor/ Schneider/ Havells
Ceiling rose surface Bakelite 3 terminals PVC/ Poly carbonate isolated body including base block complete all as specified and directed.
Exhaust Fan, Steel body heavy duty AC single phase 230V of size 300m sweep with blades, frame and louvers shutter, voltage 230V, 50Hz, copper winding, connecting up including provision of three core flexible copper wire of size 23/0.0076 all as specifie and directed. Make: Havells/ CG/ Orient
Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.Make:Havells/CG/Orient
MCB DB, TPN 6 way suitable for three phase 440 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCB's single/double pole complete all as specified and directed. Make:Havells/ Legrand /C&S
Supply and fixing 415V 10KA 'B' curve Isolator four poles and upto 63 amps current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed. Make:Havells/ Legrand /C&S
Supply and fixing 415V, 10 KA 'B' curve miniature circuit breaker (MCB) of four poles and current carrying capacity 16 to 32 AMP, in the MCB DB Complete with connection testing and commissioning all as specified and directed. Make: ABB/ Legrand/ L&T.
Supply and fix MCB SPN 32 amps.all as specified and directed. Make:Havells or equivalent in Legrand / Standard
Supply and fix MCB SP 5 to 32 amps.all as specified and directed. Make:Havells or equivalent in Legrand / Standard
Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings 230V all as specified and directed.
Supply and fix emergency LED bulb operating voltage 120-300 V AC IP 20 wattage 9 CCT 6500K lumen output 900 (Main) 350 (Battery) 4hr backup B-22 holder type all as specified and directed. Make: Halonix Product code - Inverter light 09W B22 CW IP, Panasonic - PBUM13097R1 or equivalent in Bajaj
LED bulk head light fitting 10 W 6500K lumen output 1080 including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make- Halonix Product code - HLBH-02-CW / Panasonic - PBHM03107 / SURYA - SLE BT 10W Arrow
LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed. Make- Halonix Product code- HLB-07-20-CW-IP / Panasonic - PBTM24207 / HAVELLS - LHEXBQP71N1W009
LED light fitting mirror type with high out put diffuser 2 feet, 1x 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specifie and directed. Make :Havells or equivalent Make- Halonix Product code- HLB-07-10-CW-IP / Panasonic - PBTM24107 / HAVELLS - LHEXBQP51N1W009
LED building security street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make- Halonix Product code- HLSLD-E1-36-CWDL-R01 / Panasonic - PSTM29358R1 / HAVELLS - LHETAXU7PN6J045
Cutting chases in brick / stone masonary for concealed water tubing or concealed conduit for wiring, etc. and making good, cutting, exceeding 20cm girth or all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.complete all as specified and directed
Sub main wiring with two runs of single core 1.5 Sqmm copper conductor FRLS cable, PVC insulated, unsheathed multistanded, 1100V grade drawn through non metallic rigid PVC conduit all accessories such as bend, elbow, socket, tee saddles etc., fixed to wall / fixed to ceiling etc including 1.5 Sqmm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100 V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note:- 2 runs of 1.5 Sqmm, one run of 1.5 Sqmm copper cable and one run of PVC conduit will be measured as one length.
Earthing complete with GI earth plate electrode 60cmx60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth wire 4mm dia by means of bolts and nuts washers mase out of GI and earth strip protected by Galvanized pipe light grade 15mm bore, 20 mm bore medium grade watering pipe and connected to main control board all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified.
Material and labour for installation of Air termination, single pointed aluminium rod 12mm dia and 300mm long in repairs all as specified and directed.
Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed.
Earthling complete with GI earth plate electrode 60x60cmx6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip of size 32x6mm by means of bolts and nuts washers mase out of GI and earth wire protected by Galvanized pipe light grade 15mm bore, 40 mm bore medium grade and connected to man control board all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick, RCC 1:2:4 cover slab with 6mm dia MS bars etc complete all as specified.
Integral avation light comprising of aluminium housing with polycorbonate enclosure with LED lamps fixed in position on over head tank minimum height 30 meter staging with provisiong of 1.5Sq.mm 3 core multi stranded copper conductor cable passing through pvc conduit pipe with all fixing accessories incl taking down old unsv light fitting complete all as specified
Point wiring complete with two runs of 1.5Sqmm (for Phase and Netural) PVC insulated unsheathed multistranded copper conductor FRLS cable of 1100V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit medium grade ISI, Marked with conduit accessories on wall / floor and fixed on ceiling / roof/ truss/ columns etc including provision of factory made branded galvanized steel pressed steel terminal box (modular metal flush box) 3mm thick of suitable module of housing the modular switches, sockets, fan regulators etc, complete concealed in walls and provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc for one light point controlled by one modular switch complete all as specified and directed.
All as per Item No 196 hereinbefore but one ceiling/ Exhaust fan point controlled by one modular switch all as specified and directed.
MCB DB, SPN 4 way suitable for single phase 240 volts with 200 Amps rated bus bar, double door type suitable for mounting incoming and outgoing MCBs single/ double pole including dismantling of old existing complete all as specified and directed.
TECKXPERT ENTERPRISES (BID ID -3483168)
UNIQUE INDIA CONSTRUCTIONS (BID ID -3484531)
m/s prabakaran (BID ID -3484456)
SEMBA ELECTRICALS (BID ID -3484009)
RISHAN INFRA ENTERPRISES (BID ID -3482026)
MSR ENTERPRISES (BID ID -3485006)
VENKATESH (BID ID -3483595)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Tender8148.pdf
Tender Documents • 1.14 MB
BOQ_827321.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .