Tender Value
₹53.1 L
EMD Value
₹1.1 L
Closing Date
30 May 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Capital (Works)
Above/Below/Par
RN
2 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' OR 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited.The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared / audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Appendix - 5 along with the copies of Audited Balance sheet, duly certified by the chartered Accountant / Certificate from chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed OR substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(a) Three similar works costing not less than the amount equal to 30% of advertised value of the tender, OR(b)Two similar works costing not less than the amount equal to 40% of advertised value of the tender, OR(c)One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar work: Any work of Provision or maintenance of Automatic Fire Detection and Alarm/ Automatic Fire suppression System. OR Any Signalling Work which includes Provision of Automatic fire detection and Alarm/ Automatic Fire suppression System
7 conditions · 6 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Appendix - 2 Any work of Provision or maintenance of Automatic Fire Detection and Alarm/ Automatic Fire suppression System. OR Any Signalling Work which includes Provision of Automatic fire detection and Alarm/ Automatic Fire suppression System (as defined clause 5.2 of Instruction to Tenderer)
Appendix 5 : Contractual Turnover (As per Annexure VI B of KR GCC July- 2022, duly certified by the Chartered Accountant.)
Appendix 11 : Undertaking by Tenderer
Appendix 21 : Affidavit to be submitted/uploaded by tenderer along with the tender documents
Appendix 21A: (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
Schedule C - Annual Rate Contract (ARC) for Five Years (after two-year warranty period) for Equipment & Accessories as per RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd (for terms & conditions of ARC refer clause No 5 of Special conditions of Contract Part B) ( Click here to download Format)
Provision of Automatic Fire Detection and Alarm System with Aspiration Type Air Sampling Detector at 03 stations, namely Ratnagiri, Kankavali, and Kudal, covering all S&T rooms of stations provided with Panel Interlocking and Provision of Aspiration Type Air Sampling Detectors at 10 goomties. The work also includes interfacing with the existing AFDAS at goomties located at Kolad, Mangaon, Veer, Goregaon, and Indapur stations in Ratnagiri Region of Konkan Railway
KR-RN-SG-T-02-2026-27
KR-RN-SG-T-02-2026-27
Open
Works - General
4 Months
Ratnagiri, Maharashtra
₹0
₹1.1 L
30 May 2026
9 May 2026
16 May 2026
30 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 17,04,644.91 | ||
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of UL/EN/FM/Vds/LPCB approved microprocessor based networkable analogue addressable and modular type of fire alarm control panel with display, in built change facility and provision of GSM module suitable to send SMS to mobile etc. The panel should be equipped with sufficient Nos. of loops and provision of expandability The control panel shall be the central processing unit of the system receiving and analysing signals from probe type bimetallic heat detectors, UV & IR f lamedetectors, heat and smoke multi sensors, LHS interface and manual call points, providing audiable and visual information to the user. The panel shall have provision of connectivity of TCP - IP suitable for programming and remote monitoring. The panel shall have dedicated RS232 serial port for direct PC or MODEM connection for interfacing with existing Datalogger, optional remote printer asper RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd. Inspection: RDSO Inspection | — | — | — | 2,64,288.48 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of resettable probe type bimetallic heat as per IS 2189 asper RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd. Inspection: RDSO Inspection | — | — | — | 10,967.07 | |
| — | 33.00 | — | — | ||
| Supply, installation, testing and commissioning of resettable, addressable, multi sensor (heat & smoke) which is fully compatible with analogue addressable protocol, electronically addressed as per RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd. Inspection: RDSO Inspection | — | — | — | 84,364.83 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of addressable, resettable, manual call point with integral short circuit isolator having status LED for alarming & standby mode electronically addressed as per RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd. Inspection: RDSO Inspection | — | — | — | 20,510.28 | |
| Supply, installation, testing and commissioning of UL/EN/FM/Vds/LPCB approved UV/IR type flame detector with required module to communicate on main fire alarm panel as per RDSO Spec No. RDSO/SPN/217/2025 Ver.3.1 with latest Amd. Inspection: RDSO Inspection | — | 3.00 | — | — | |
| — | 408.00 | — | — | ||
| — | 3.00 | — | — | ||
| — | 3.00 | — | — | ||
| — | 150.00 | — | — | ||
| Supply, installation, testing and commissioning of CPVC pipe and all other associated fittings. As per RDSO specification no RDSO/SPN/217/2025 Ver.3.1 or latest. Insp by RDSO. Inspection: RDSO Inspection | — | — | — | 56,346 | |
| — | 3.00 | Lumpsum | — | ||
| Supply, installation, testing and commissioning of FRLS/fire survival circuits integrity cable i.e. Armoured cable & power cable with all accessories for connection of all fire alarm devices as per RDSO RDSO/SPN/217/2025 Ver.3.1 with latest Amd. | — | — | — | 77,139.72 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderdocumentforAFDAS09.05.26.pdf Tender Document AFDAS
ATTACHMENT
KRGCC-July2022.pdf
ATTACHMENT
TenderdocumentforAFDAS09.05.26.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .