Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L1 | Accepted-AOC Being reasonable and lowest L1 | |
| 2 | L2₹47.4 L+₹2.6 L (5.79%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L2 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
17 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col SS Bose, CWE
HQ CWE (AF) Chakeri, Kanpur 208008
PREVENTIVE MAINT OF HV PANELS INCLUDING CALIBERATION OF RELAYS AND REPLACEMENT OF DEFECTIVE PARTS AT AF STN CHAKERI KANPUR
2020_MES_362854_2
82157/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
Chakeri, Kanpur
Class D cat b (ii)
8 documents required · 8 mandatory
₹500
GE (AF) E/M Chakeri
₹96,000
22 Dec 2020
17 Sept 2020
24 Oct 2020
17 Sept 2020
17 Oct 2020
3 Oct 2020
60 days
Amount
Disconnecting of HT supply from 11 KV OCB of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution and inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc including draining out and refilling fresh transformer oil of 60KV die-electric strength by replacing old gasket etc complete all as specified & directed.
Disconnecting of HT supply from 11 KV VCB of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution and inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc including checking of vaccume intrupter, tripping mechanism and ratchet wheel & spring charging mechanism etc after servicing complete all as specified & directed.
Disconnecting of HT supply from 33 KV VCB/SF-6 breaker of any make/type/capacity for repair works, servicing and taking out trolley with complete decarburizing the contact points, cleaning with CRC solution inner body cleaning with vaccum cleaner etc and repair/replacement of defective parts found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc including checking of its control panel and power TR protection system such as defferential realy, master trip relay, power TR oil/winding temp, bucozz relay and mechanical system etc after servicing, testing complete all as specified & directed. Note for srl item 1.00 to 3.00 :- (i) Spare parts will be measured and paid for separately under respective item and copper wire and ferule required for wiring shall be included in quoted unit rate of theseitems. (ii) For testing and calibration of relays will be measured and paid separately under respective items.
Supply only following parts of HT OCB required for item No 01 here-in-before :-
Termials spout bushing suitable for 400 Amps HT OCB. Make/Type- As per existing sample.
Male & female contact set, heavy duty for HT OCB. Make/Type- As per existing sample.
Shunt trip closing coil assembly. Make/Type- As per existing sample.
Shunt trip tripping coil assembly. Make/Type- As per existing sample.
Spring charging mechanical assembly with locking arrengement, Make/Type- As per existing sample.
Rack in/out mechanical system with handle. Make/Type- As per existing sample.
ON/OFF position indicator system with colour code. Make/Type- As per existing sample.
Supply and topping up/filling of transformer oil in HT OCB having dielectric strength 60KV/mm in sealed container complete all as specified and directed. Make:- IOC/HP/Castrol.
Taking out IDMT relays from panel. Opening it for repair work, servicing complete with decarburizing the contact points, cleaning with CRC solution and inner body clean with vaccum cleaner etc and repair/replacement of all defective parts if any found during servicing. Reassembling and testing of relays for tripping time setting, over current setting, earth fault setting etc complete all as specified and directed. NOTE :- All parts are deemed to be include in the quoted unit rate required for relay in service condition.
Supply only following parts of HT VCB required for item No 2.00 & 3.00 here-in- before :-
Spring charging motor 24/240 Volt DC/AC for 11KV VCB, Bus Coupler of existing make, type, size & capacity with driving gear suitable for existing VCBs model complete all as specified and directed at site.
Spring charging motor 110/220 Volt DC/AC for 33KV VCB/SF-6 breaker of existing make, type, size & capacity complete all as specified and directed at site.
Spring charging motor 30/240 Volt DC/AC for 11KV & 33KV VCB of existing make, type, size & capacity complete suitable for existing VCBs complete all as specified and directed at site.
Open/Close auxiliary contacts switch suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Plug-Socket connectors of electrical accessories suitable for upto 1250 Amps HT VCB. (Make/Type- As per existing sample).
Door locking handle suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Trolly alignment lever suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Under voltage release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Over voltage release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Under/over frequency release suitable for upto 1250 Amps HT VCB. Make/Type- As per existing sample.
Shunt trip closing coil assembly 110/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip tripping coil assembly 110/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip closing coil assembly 24-30/220 volts, DC/AC. Make/Type- As per existing sample.
Shunt trip tripping coil assembly 24-30/220 volts, DC/AC. Make/Type- As per existing sample.
Series trip coil 24-30/220 volts, DC/AC. Make/Type- As per existing sample.
Spring charging Motor Cut of switch. Make/Type- As per existing sample.
Ratchet wheel Assembly (small, large & middle gear assy). Make/Type- As per existing sample.
Manual spring charging gear assembly complete. Make/Type- As per existing sample.
Breaker IN/OUT handle. Make/Type- As per existing sample.
Local remote switch. Make/Type- As per existing sample.
Test/service position indicator. Make/Type- As per existing sample.
Breaker control switch. Make/Type- As per existing sample.
Mechanism charged/discharge indicator switch. Make/Type- As per existing sample.
Toggle ON/OFF switch for Heater & illumination circuit. Make/Type- As per existing sample.
Mechanical ON/OFF indication.
Door switch. Make/Type- As per existing sample.
Push button. Make/Type- As per existing sample.
ON/OFF Emergency trip push button. Make/Type- As per existing sample.
Indicator lamp LED type complete with holder to read RYB with necessary wiring complete.
Operation counter. Make/Type- As per existing sample.
TNC control switch with pistol grip.
Spring charging handle.
VCB operating handle.
Terminal connectors.
Annunciator, 4 Window with existing dimension on panel for OC/EF/WTI/OTI/ Bucholz trip, with inbuilt PB of mute, ACK, Reset, Accept.
Master relay operating voltage 24V/110V DC or as per sample complete all as directed.
Spacer Heater. Make/Type- As per existing sample.
Thermostate 30-90 Deg.
Hooters. Make/Type- As per existing sample.
Terminal Block for CT wire.
Terminal Block for Remote feedback/within panel/board wire
NO/NC Contacts.
Bridge rectifier.
Auxiliary switch 7NO + 7NC.
"ZZ" micro switch.
Butterfly switch for motor cut off.
Motor cut off switch (Cherry).
Timer for spring charging motor.
Drive link assembly with adjuster.
Big cam with main shaft with bearing & cover.
Trip /Close shaft assembly with springs & closing strips.
11KV, VCB Fixed contact suitable for 400Amp capacity. Make/Type- As per existing sample.
11KV, VCB moving contact suitable for 400Amp capacity. Make/Type- As per existing sample.
11KV, VCB Fixed contact suitable for 630Amp capacity. Make/Type- As per existing sample.
11KV, VCB moving contact suitable for 630Amp capacity. Make/Type- As per existing sample.
11KV, VCB Fixed contact suitable for 800Amp capacity. Make/Type- As per existing sample.
11KV, VCB moving contact suitable for 800Amp capacity. Make/Type- As per existing sample.
11KV, VCB Fixed contact suitable for 1250Amp capacity. Make/Type- As per existing sample.
11KV, VCB moving contact suitable for 1250Amp capacity. Make/Type- As per existing sample.
Spring for trip lever. Make/Type- As per existing sample.
Spout insulator incl hardware suitable for 11KV VCB of various capacity.
Spur gear of sizes as per sample suitable for upward or downward trolly movement mechanism with lock and bushing as required for 11KV VCB/OCB/bus coupler complete all as specified and directed.
Trip shackle lever. Make/Type- As per existing sample.
Ratchet Pin suitable for HT VCB (As per sample) complete all as directed.
Insulated dust proof cover frame. Make/Type- As per existing sample.
Push Rod. Make/Type- As per existing sample.
Under voltage release mechanical override. Make/Type- As per existing sample.
Opening solenoid (MO3) device. Make/Type- As per existing sample.
Rack in out mechanical rod with handle. Make/Type- As per existing sample.
Trip Prop block Assy. Make/Type- As per existing sample.
Fuses holder suitable for cylindrical/DIN fuse.
HRC fuse (link type) having capacity 2 to 6 amp, 415 V, 80 KA.
HRC fuse (link type) having capacity 10 to 32 amp, 415 V, 80 KA.
11 KV, VCB, PT fuse 3.15 Amp complete as per sample.
Stud type terminals of 24V/110V DC suitable for 11KV VCB.
Antipumping Contactor 4NO+4NC, 24V/110V DC, 6 Amp.
Auxilary contactor for contact multiplication 4NO+4NC, 24V/110V, DC, 6 Amp.
Testing and caliberation of HT OCB / VCB 11 KV complete with primary and secondary test as required including checking of wiring of all electrical measuring instrument and resetting of relay and proper alignment mechanical system for smooth functioning and tripping at any type of fault developed in feeders complete all as specified and directed by Engr in Charge. Note :- Contractor will submit primary and secondary test record at the time of caliberation of HT OCB , VCB, SF-6 based panel, TR control panel by current injecting kit duly signed to Engineer In Charge. The rate quoted by tenderer shall deemed to include the cost of this provision incl T&P required for injecting regulated high current, HT megger and other sundary items as required in complaince with relevent IS/IEC codes complete all as specified & directed.
S&F in replacement Vaccum interrupter bottle for vaccum circuit breaker of 400 Amps in HT panel 11000 volts grade incl taking out old interrupter interruter complete all as specified & directed. (Make : L&T/ABB/CG/Areva).
All as per Srl item No 8.00 above but 630 Amps capacity.
All as per Srl item No 8.00 above but 800 Amps capacity.
All as per Srl item No 8.00 above but 1250 Amps capacity.
S&F in replacement indicators flush mounted, high intensity, clustered LED type, insulated from 30/220 V, DC/AC supply with appropriate coloured lense (Red, Green, Blue, Amber, White) complete all as specified and directed.
S&F in replacement Digital Multifuction meter (LCD) 3ph, 3W, IPM 110 V (L-L) 5A, Class 0.5 FM , Flush mounting 96x96mm CT/PT side programmable, Parameters - V, A, F, PF,kW, kVA, kVAR, kWh, Kvah and kVARh, THD, phase angles or power demand etc including fixing arrangment nuts,bolts, washers Hylem sheet, as required at site complete testing all as specified and directed. (Make- L&T, Schneider, Siemens as approved by GE).
S & F in replacement MCB single pole 6 to 10 amps of 10 KA in existing panel with incoming and outgoing connection complete all asspecified & directed. (Make : Legrand/L&T/Siemens as approved by GE)
S & F in replacement of HT VCB Aluminium alloy bus bar air insulated, appropriate size and length with 11KV grade Polipro power line protector (sleeve) for designed to insulate bare busbar to prevent accidents due to electrocution/ ionisation. The protector should have excellent UV resistance, abrasion resistance, fire resistance properties, good dieelectric strength & maintenance free complete all as specified & directed.
S&F in replacement Bus Support insulators, non hygroscopic, track-resistant, high strength epoxy insulators complete all as specified and directed.
S & F in replacement of lugs, tinned copper, pre-insulated fork and pin type as applicable complete all as specified & directed.
Supply, installation, testing and commissioning in replacement of 11KV Current Transformer with Indoor & Resin cast type single pole (Three core type) CTR-150-75/5+5A, STR - 18.4kA/1Sec, Class - 15VA/CL1.0+15VA/5P10 fixing on existing 11 KV panel including necessary connections, any modification required, addition/alteration required for fixing CT in existing 11 KV panel complete all as specified & directed.
All as per Srl item No 18.00 above but CTR-125/5+5A, STR - 18.4kA/1Sec.
All as per Srl item No 18.00 above but CTR-100/5+5A, STR - 18.4kA/1Sec.
All as per Srl item No 18.00 above but CTR-80/5+5A, STR - 18.4kA/1Sec.
S & F in replacement of unsv defective PT unit 3PH, Drawout type, VTR - 11000/110V AC, BA- 100VA/CL0.5 of breaker in VCB make Crompton for model- ALA/XLU including complete dismentling the complete voltage transformer from VCB including, nut bolts, washers, re-assembling the complete parts, complete testing for smooth operation, complete all as directed. (Make - Crompton Greaves of Voltage Transformer Type - 3PH, Drawout type, VTR - 11000/110V AC, BA- 100VA/CL0.5 or equivalent as approved by GE)
Replacement of auxiliary power supply/ battery bank with panel made of 2mm CRCA sheet complete with maintenance free lead acid battery bank mounted on MS rack and provide with connector etc complete in all respect with install capacity 30Volts DC 15Nos each of 2 Volts 60AH including booster charger all as per standard specification and including DCDB for charger complete with DC Amps Meter Volt meter, switches ON/OFF, TRICKEL/BOOSTER complete all as specified and specified & directed.
M & L in replacement of Batteries 12V of 60 AH for Power pack unit 230V AC/110V AC/30 Volts DC suitable for operating 110V/30V closing coil complete. (Make: Exide or equivalent as approved by GE).
M&L for wiring from battery charger to all connected 11KV VCB with 2.5 sqmm, 1100 volt grade multi strand flexible copper conducter with PVC flexible pipe and shall be properly bunched, tied, ferruled for proper indication and crimped with adequate size/types of lugs after wiring testing complete all as specified and directed.
Supply and errection of fire stand of suitable size made out of MS / angle iron/ chanel duly painted with two coats of synthetic enamelled post office red colour over a coat of red oxide as primer and lettering with white paint including providing the following all as directed by Engineer-in -charge:- a) Galvanised MS fire buckets 9 litre capacity - 04 No's b) Portable fire extinguisher CO2 type 4 Kg capacity - 04 No's complete (Make:- Ceasefire / Firex/Omex (ABC)
Material and Labour for painting of HT switch gears VCBs outer surface and inner surface complete with synthetic enamel paint two coats by spray painting approved colour after cleaning of surface/rusted portion including sign writing i.e. MES/SM No Make/ Capacity 11000 Volts" and DANGER" including formation of Bone and Skull of appropriate size etc. complete all as specified & directed.
Supply and fix in replacement Power Pack for 11 KV VCB suitable for incoming supply 220/30 volts AC/DC supply and output 30 volts DC supply all as per existing with wiring all connected VCB complete all as specified & directed. Note : Battery backup of Power Pack shall be not less than 45 minute.
S&F PVC insulated and PVC sheathed cable galvanised steel stip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 1.5 Sqmm 12 core 1100 volt grade incl taking out old cable of any size and type complete all as specified & directed.
All as per item No 30.00 here in before but 1.5 Sqmm 8 core 1100 volts grade.
All as per item No 30.00 here in before but 2.5 Sqmm 4 core 1100 volts grade.
S&F in repair GI nuts, bolts, off sizes complete with 3mm thick washers as per site requirement.
S & F in replacement of HT VCB copper alloy bus bar air insulated, appropriate size and length with 11KV grade Polipro power line protector (sleeve) for designed to insulate bare busbar to prevent accidents due to electrocution/ ionisation. The protector should have excellent UV resistance, abrasion resistance, fire resistance properties, good dieelectric strength & maintenance free complete all as directed by Engr-in-Charge.
S & F in replacement of 33 KV single phase out door oil cooled PT of ratio 33KV/ √3 / 110 V/√3 class 0.5 - 3 . Burden 200 VA. Insulation class 70/170 KV , voltage fector 1.2 cont and 1.9 for 30 sec , confirming to IS : 3156 complete.
S & F in replacement of 33KV single phase out door oil cooled CT of ratio 100/50 + 5 amps class 1.0 - 5P 10 burden 15 VA insulation level 70KV/170 KV as per IS : 2705 complete.
S & F in replacement lighting arrester expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable for 33000 V including taking down old unserviceable lighting arrester.
M&L XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 33000 volts grade of cross section area 300 Sqmm, 3 core complete including taking down U/S cable complete all as specified & directed.. (Make : Havells, Universal, Finolex, Polycab, Gloster).
Supply and fixing cable jointing kit termination outdoor type for HT 33KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 300 Sqmm, 3 core and testing after jointing complete all as specified & directed.. (Make :- Reychem, M- Seal, Cabseal).
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 33/11 KV HT cable by giving high voltage surge and to find out exact location of fault all as specified & directed. (Note : The Item includes transportation, charging machine upto detecting fault at a time)
S&F heat shrinkable straight through cable joint kit for XLPE (earthed) 11KV volt grade of size 120 to 185 Sqmm 3 core aluminium conductor cable complete incl taking out old jointing kit of any make and type all as specified and directed. (Make :- Denson or Reychem or 3M).
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, 3 core cable and testing after jointing complete all as specified & directed.. (Make :- Denson or Reychem or 3M).
Material and Labour for maintenance and repair of ACB up to 1600 Amps capacity including de-assembly all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/ greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re-assembly, fine setting of mechanism and pole assembly and making ACB perfect operational including well cleaning the complete panel bus bars chamber, insulator, partition etc and checking of insulation resistance of ACB and main bus bar complete all as specified & directed. Note:- (i) Spare parts for ACB to be measured and paid separately as supply only. (ii) The cost for replacement of spare parts shall be deemed included in quoted unit rate.
Supply only following parts for ACB item No 43.00 here-in-before:-
Male contacts of existing size & Capacity
Female contacts of existing size & Capacity
Locakable Trip Push Button (LTPB)
Lock in Isolation Position (LIP) assembly
Lock in any position (LAP) assembly)
Door interlock assembly
Shunt Release (SR) of existing capacity
Under Voltage release (UVR)
Earth Fault Release (for DN1)
Vertical terminal adaptor
Spring Charging handle.
S & F in replacement of Air circuit breaker 800 Amp, 4 pole, manual draw out type for over load, short circuit, ground fault protection suitable for rated system voltage 415V. ACB shall conforming to IEC 60947/2 IS 13947 (part 1 & 2), ACB shall have Ics=Icu=Icw=50KA, Icw rating shall be for 1 sec, release shall be provided with LED and must be suitable for fixing in existing space or else shall be provided with separate enclosure with IP65 & necessary connections with existing busbar complete all as specified & directed. Make : L&T (cat No- N-15800SI) or equivalent in Schneider, Havells, Legrand.
Labour only for checking the serviceability of ACB/OCB/ACB/CT/PT panels or any connected electrical switch gear at 11 KV voltage level of any capacity including disconnecting HT/LT supply from any VCB & ACB if needed and testing of different spares / components / parts of panels of any description and in any position, checking functioning of relay, coils, switches, ratchet wheel assy, chrging motor, fuses contactors, MCCBs etc and their replacement if found to be unserviceable, regular cleaning of dust & dirt deposit due to natural effects, removal of carbon deposits it any or as direction of Engr-in-Charge. Replacement of un-serviceable/ damaged /broken part(s) either in single or in combination, re-assembling the panels and making the serviceable, fixing the VCB/ACB in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. NOTE FOR ITEM NO 1.00 TO 46.00:- The above schedule is meant for maintenance of HV panels of AFS Kanpur. The contractor shall depute his representative to Engineer -in-charge or his representative (JE incharge of the contract) on daily basis to collect the complaints. There after contractor shall deploy sufficient manpower to attend the complaints on daily basis. The contractor shall arrange his resources accordingly. Non -compliance of the above on account of contractor's representative to Engineer incharge/JE or deployment of in-sufficient manpower to attend the complaints shall be bound to a penalty of Rs 1000/- per complaint per day after 02 Hrs of communication of complaint by any mode of communication (via SMS, telephone call, what's app etc to contractor/contractors rep) upto a max. of Rs 10000/- per day. Contractor must also mobilise/procure/arrange all tools & machinary like megger, earthing rod, protective gear, test lamp etc for expeditions & safe working compulsary.
Bharat Sales Corporation
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .