Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.9 LAccepted-AOC 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹97.0 L+₹10.1 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹1.1 Cr+₹24.6 L (28.3%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹1.1 Cr+₹25.9 L (29.9%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹1.2 Cr+₹31.1 L (35.8%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
19 Jul 2023, 6:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE LT SWITCHGEARS CAPACITOR BANK UG CABLES BUSBAR CHAMBERS AND OTHER EXTERNAL ELECTRIC WORKS IN RS AREA AND REPAIR MAINTENANCE AND REPLACEMENT OF BURNT DAMAGED LIGHTENING CONDUCTOR DOWN CONDUCTORS EAR
2023_MES_601862_1
8280/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class B and category b(i)
8 documents required · 8 mandatory
₹1,000
GE NW NAVY NAGAR COLABA MUMBAI
₹2.1 L
Yes
28 Aug 2023
7 Jun 2023
20 Jul 2023
7 Jun 2023
19 Jul 2023
28 Jun 2023
7 Jun 2023 - 12 Jul 2023
Amount
M&L for replacement of LT panel board at R-35 bldg, factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including air louvers at both side, rain shed 15 cm all around, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x400mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x5 mm thick, front and rear opening with double shutter and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x8mm suitable length- 04 Nos
Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No.s Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer.
All as per Item No.1 above but for near Motivation Hall and scope of work including provision of housing the following accessories:- Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iii) MCCB 160 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No.s Make: Schneider, L&T or Legrand. (iv) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (iii) MCCB 100 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No.s Make: Schneider, L&T or Legrand. (iv) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer.
All as per Item No.1 above but scope of work including provision of housing the following accessories: Incoming: - (i) MCCB 630 Amp 4 pole 36 KA 415 V with microprocessor release having protection against over current, earth fault, short circuits and inbuilt battery and display system - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 630 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells.
(iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 50x10mm suitable length-04 Nos Outgoing: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (ii) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 04 No. Make: Schneider, L&T or Legrand. (iii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer.
All as per Item No.1 above but scope of work including provision of housing the following accessories:- Incoming: - (i) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 250 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 40x6mm suitable length-04 Nos
Outgoing: - (i) MCCB 160 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (ii) MCCB 125 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iii) MCCB 63 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iv) Power contactor 4 pole 40 Amp, 415 V - 02 No. Make: Schneider, L&T or Legrand. (v) Analog time switch 3 module - 02 No. Make: Schneider, L&T or Legrand. (vi) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer
All as per Item No.1 above but scope of work including provision of housing the following accessories:- Incoming: - (i) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand. (ii) On Load Changeover switch 200 Amp, 415V, 4 pole with open execution with front handle - 01 No. Make: Schneider, L&T or Havells. (iii) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (iv) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability - 01 Nos. Make: Securemeters, Reshab or L&T. (v) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (vi) Tinned copper bus bar strips made of copper of size 40x6mm suitable length-04 Nos Outgoing: - (i) MCCB 63/100 Amp 4 pole 25 KA 415 V with thermal magnetic release, Ics=100% Icu. - 06 No.s Make: Schneider, L&T or Legrand. (ii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 5 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer
M&L for replacement of LT panel board at dhanush sub station, factory made pedestal cubical single door, indoor type, CPRI approved, modular construction fabricated out of 2.0 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front side opening system including air louvers at both side, overall size of each incoming & out going modules should not be less than ( 350mm x300mm x350mm ), platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 50x50x6 mm thick, including grouting of panel with necessary PCC work complete all as specified. The scope of work including provision of housing the following accessories:- (Make of Panel - Incoming: - (i) ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 2000 Amps with complete accessories - 01 No. Make: Havells, L&T or Legrand. (ii) Multifunction meter Digital type with CTs to measure V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events (High-Low), Neutral Current , K Factor with RS485 - 01 Nos. Make: Securemeters, Reshab or L&T. (iii) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (iv) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-04 Nos
Outgoing: - (i) ACB 4 Pole, 415 V, Manual Drawout type with thermal magnetic release of capacity 800 Amps with complete accessories - 01 No. Make: Havells, L&T or Legrand. - 01 No.s Make: Schneider, L&T or Legrand. (ii) MCCB 400 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No. Make: Schneider, L&T or Legrand. (iii) MCCB 250 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 06 No. Make: Schneider, L&T or Legrand. (iv) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 06 No.s Make: Schneider, L&T or Legrand. (v) MCCB 160 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 02 No.s Make: Schneider, L&T or Legrand. (vii) All outgoing MCCB shall be connected through spreader and copper busbar not less than 8 mm thick strip. Note: (i) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (ii) Before fabrication of panel, contractor has to take approval on drawing from accepting officer
M&L for Dismantling and taking out old Capacitor Panel and Supply, fix install testing and commissioning of APFC Panel board 400KVAR (Capacitor Panel) indoor type, cubical shape 3 phase, 4 wire, copper bus bar rating 1200 amps for phases and 1000 amps for neutral made out of CRCA sheet, 2 mm thick ,factory fabricated, CPRI Certfied , powder coated ,dust and vermin proof , provn for ventilation , having seperate compartment /chambers for cable gallery busbar, switch gear,Capacitors, floor mounted type based on angle iron frame and legs 50x50x6 mm thick, front and rear opening with double shutter etc all as specified and comprising of following.
(a) Capacitor bank Heavy duty type,415Volts,Cylindrical type, 50Hz AC. Make:Prabodhan/Epcos/Havells/L&T/C&S. (i) 5KVAR -2Nos (ii)10KVAR-2Nos (iii) 15KVAR-2Nos (iv) 20KVAR-2Nos (v) 25KVAR -4Nos (vi) 50KVAR -4Nos
(b) Contactors Capacitor duty,TP,415Volts,50Hz AC sutable forfollowing. Make: Havells/L&T/C&S/Schneider (i) 5KVAR -2Nos (ii)10KVAR-2Nos (iii) 15KVAR-2Nos (iv) 20KVAR-2Nos (v) 25KVAR -4Nos (vi) 50KVAR -4Nos
(c) MCB, TP, 415Volts, 50Hz Make: Havells/L&T/C&S/IndoAsian/Schnieder (i) 10Amps -2Nos (ii)16Amps-2Nos (iii)25Amps-2Nos (iv)32Amps-2Nos (v) 40Amps -4Nos (vi) 63Amps -4Nos
M&L for in replacement of MCCBs thermal magnetic release,lcs=100% lcu in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testting after complition, all as specified and directed, of following capacities :-
MCCB 63/100 Amps,16 kA, TP, 50 Hz.
MCCB 160 Amps, 36 kA, FP, 50 Hz.
MCCB 200 Amps, 36 kA, FP, 50 Hz.
MCCB 250 Amps, 36 kA, FP, 50 Hz.
MCCB 400 Amps, 36 kA, FP, 50 Hz.
M&L for in replacement of Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos.
M&L for in replacement of Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability complete all as specified.
Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables .
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
Removing excavated material from the site of work to outside MD land complete all as specified.
Supply, filling, spreading levelling and well ramming the river sand around cable in trenches for cable cushioning all as specified and directed. Note : Punned thickness shall be measured and paid.
Supply and laying un-reinforced pecast concete cable covers class LV, Type 1, flat, size 250mmx 150mm x 40mm all as specified and directed.
Cutting existing road surface or hard standing, bituminous topping 15 cm but n exc 30cm girth for laying of pipes/ cables and making good distrubed surface to match with existing complete.
M&L for making good of road cutting upto 450 mm wide, clean the cutting surfaces and filling hard cor and match the existing bitumen surface of road with premix bitumenus material ready to use complete all sa specified and directed by Engr-in-charge.
M & L for cement concrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in foundations, filling and mass concrete finished fair and even comlpete all as specified
Supply, Fixing, testing and commissioning of XLPE insulated armoured, heavy duty electric cable with aluminium conductor of size 300 sqmm 3.5 core, 1100 volt grade laid in trenches, fixed on wall, passing through pipes complete including connecting with MCCB/ busbar with the help of proper size thimble, glands, properly as directed by engineer-in-charge and taking out existing damaged unserviceable cable. Note : Excavation, earthwork and cable protection shall be measured and paid separately under relevant items.
Same as Item No 20.00 above but size 150 Sq mm, 3.5 core
Same as Item No 20.00 above but size 120 Sq mm, 3.5 core
Same as Item No 20.00 above but size 95 Sq mm, 3.5 core
Same as Item No 20.00 above but size 50 Sq mm, 3.5 core
Same as Item No 20.00 above but size 35 Sq mm, 3.5 core
Same as Item No 20.00 above but size 25 Sq mm, 3.5 core
M&L for in replacement of GI pipe ,light grade 50mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
M&L for in replacement of GI pipe ,light grade 80mm dia for road crossing of cable for cable protection or above ground surface including taking out old one all as specified and directed.
M&L for in replacement of GI pipe, light grade 100mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M & L for fixing of old interlocking paver tiles/blocks of any sizes recovered form item SI. No. 17 including laying over 50 mm thick sand bed compacted complete as specified and directed.
M & L for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of existing size and existing type and including laying over 50 mm thick sand bed compacted complete as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, 40mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 75mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
M&L for in replacement of High density poly-ethylene pipes (HDPE) of pressure 4 kgf/cm2 pipe, 100/110mm dia for road crossing of cable or for cable protection of cable above ground surface all as specified and directed.
Material and labour for fault finding on LT cables of any size and any length with fault detective machine by thumbing method and suitable high voltage and all as and directed by Engineer-in-charge.
Supply and fix cable jointing kit Straight Through Joint for 1.1KV grade cable complete with Jointing material (Heat shrinkable) and accessories suitable for 3.5 core XLPE armoured, alluminum conductor cable of size 25 to 95 sq mm after taking out and cutting the faulty cable area, inserting 1 mtr Cable of existing size for jointing Cables if required at site and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
All as per Item No 36.00 above but for 3.5 core XLPE armoured, alluminum conductor cable of size 120 to 185 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
All as per Item No 36.00 above but for 3.5 core XLPE armoured, alluminum conductor cable of size 240 to 300 sq mm and all as directed by Engineer-In-Charge. Make- Denson/3M/M-Seal
M&L for taking out existing Panel and shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed.
Material & labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected including taking out old, U/S lightning rod complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno/Powertrac (Aditec) Industries Ltd or approved by GE.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitable for mounting on building RCC roof with arrangement of neccessary anchoring wire, reducer and PCC work including taking out old, U/S one complete all as directed by Engineer-in-Charge. Make-JEF Techno/Powertrac Industries Ltd or approved by GE.
Supply and fixing of digital electromechanical lightning even counter housed in weather proof resistance including taking out old, U/S copper strip complete all as directed by Engineer-in-Charge. Make-JEF Techno/Powertrac Industries Ltd or approved by GE.
M & L for air termination, single pointed aluminium rod, 12mm dia, 300mm long fixing over the GI Tube with the clamps after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge
S & F Aluminium strip of size 25 x 3.15 mm fixed on walls/roof top with saddles and screws mounted suitable insulators after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge
Supply and fixing or embeded in to the PCC, Tubes medium grade galvanised, with all fitting, 40mm dia after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge.
Fixing only existing loose/hanged aluminium strip on wall/roof of high rise buildings up to 14 Floor with clamp, bracket all as specified and directed.
Supply & fixing of single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x70 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and as directed. Make of cable : Havells/Polycab/Plaza.
Supply & fixing of single core PVC insulated and PVC Innersheathed cable with aluminium conductor cable size 1x50 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and as directed. Make of cable : Havells/Polycab/Plaza.
M&L for PVC conduit pipe 25mm bore, medium mechenical stress for protection of single core PVC insulated 70 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+14 bldgs by proper clamping from roof to bottom complete all as directed.
M&L for PVC conduit pipe 20mm bore, medium mechenical stress for protection of single core PVC insulated 50 sqmm unarmoured aluminium cable fixed on external wall surfaces of G+14 bldgs by proper clamping from roof to bottom complete all as directed.
Supply and fixing test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance.
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) including earthpit with cover as specified in electrical plate No 3 of SSR Part-I after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- Make-JEF Techno/Powertrac Industries Ltd or approved by GE.
M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge
M & L for Galvanised iron strip 25 x 4mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
S & F test point terminal block for connecting the earth pit and down conductor or Aluminium strip, made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw after taking out old/unserviceable one all as specified and directed by Engineer-in-Charge
Taking down old unserviceable aviation light fittings from roof surfaces of G+14 bldg and Supply & fixing of Twin LED aviation light 2 x 6 watt comprising of aluminium housing with polycarbonate diffuser, enclosed with glass cover in frame (with total lumen output not less than less than 100 lumens/Watt) with ingress protection IP 65 and surge protection device of 5 KV capacity etc incl necessary, angle iron supports , clamps etc for installation complete and testing on completion all as specified and as directed. Make:Bajaj/Halonix/Crompton/Wipro
S & F in repairs analog time switch 3 phase of current capacity 16 Amps incl any type of accessories for fixing of time switch after taking out unserviceable one. Make: Legrand/L&T/Indoasian
M & L for armoured electric cable with copper conductor, 1100 volts grade of size 2.5 sqmm 3 core passing through pipes, fixed on wall/ceiling complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables. Make: Polycab/Havells/Plaza/Finolex
M & L for armoured electric cable with copper conductor, 1100 volts grade of size 1.5 sqmm 3 core passing through pipes, fixed on wall/ceiling complete including connecting properly by means of thimbles/bottle lugs and taking out old u/s damaged cables. Make: Polycab/Havells/Plaza/Finolex
S&F in replacement of MCB DB SPN conforming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 4 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.
All as per item No. 60.00 above but MCB DB SPN 8 way.
All as per item No. 60.00 above but MCB DB SPN 12 way.
S&F in replacement of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed.
All as per item No. 63.00 above but MCCB DB VTPN 8 way.
S&F in replacement of MCCB 125A, 16kA, 4P, Thermal magnetic release , Ics=100% Icu .
S&F in replacement of MCB TP 63A, 10kA, 415V.
S&F in replacement of MCB SPN, 32 Amp, 10 KA, 230 Volt.
S&F in replacement of MCB SP 40A, 10kA, 240V.
S&F in replacement of MCB, single pole, upto 20 Amp, 10 KA, 230 Volt.
S & F in replacement with cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
M & L for snap-on trunking system with cover, angles, bends and all accessories and fitting of size 50x80 mm fixing on wall Complete all as specified and directed . Make- Legrand Cat No-075601 or equivalent in Pressfit/Precision.
Taking out existing unarranged UG cables/conduits from wall surfaces/chhajjas fixed with ms clamp after disconnecting from DBs/LT panels and keeping aside, making good for fixing of wall trunking complete all as specified.
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring for one light/Exhaust/Ceiling fan point complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling /floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
All as per item No. 74.00 above but 3 pin socket outlet, 5 Amps on the same board with other switches.
All as per item No 74.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gang box of 8 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
All as per Item No- 83.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 83.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 83.00 above but of modular PVC Gang box, 1/2 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 10 Watt, 240V, 2ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting : Wipro/Crompton/Philips/Bajaj/Polycab
S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with electric bell ding dong, AC, 230V single pole.
Taking down old unserviceable and Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40 x 40 x 5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of CRCA sheet not less than 2 mm thick , vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 400 Amps rated copper bus bar alongwith compartment for fixing of Electronic Smart Prepaid Meters, top and bottom cable entry with proper size glands including provisions of vision glasses for meter readings as directed. Meter cabin panel shall be comprising of the following :- (Make of Panel - L&T/Legrand India Pvt Ltd/Electro Control System/Accurate Ind Control Pvt Ltd/Techno System & S/gear) (a) MCCB 4 pole, 160 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, (as outgoing) Make-Legrand/Siemens/Schneider. (c) MCB SPN 32 Amps 10 KA - 28 Nos Make-Legrand/Siemens/Schneider. (d) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 28 Nos Make-L&T/HPLor other equivelent. (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (f) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T.
(g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-28 Nos. (j) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (k) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel. Note :- (i) Before fabrication of panel the contractor has to take approval from accepting officer on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Tking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
All as per Item No.96.00 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Electro Control System/Accurate Ind Control Pvt Ltd/Techno System & S/gear) (a) MCCB 4 pole, 200 Amps, 25 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, Make-Legrand/Siemens/Schneider. (c) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, Make-Legrand/Siemens/Schneider. (d) MCB SPN 32 Amps 10 KA - 30 Nos Make-Legrand/Siemens/Schneider. (e) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 30 Nos Make-L&T/HPLor other equivelent. (f) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (g) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (h) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (j) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-30 Nos. (k) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (l) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from accepting officer on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Tking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
All as per Item No.96.00 above but scope of work including provision of housing the following accessories:- (Make of Panel - L&T/Legrand India Pvt Ltd/Electro Control System/Accurate Ind Control Pvt Ltd/Techno System & S/gear) (a) MCCB 4 pole, 125 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -01 Nos, (as incomer) Make-Legrand/Siemens/Schneider. (b) MCCB 4 pole, 63/100 Amps, 16 kA, 415 volt, thermal magnatic realease type, Ics=100% Icu -03 Nos, Make-Legrand/Siemens/Schneider. (c) MCB SPN 32 Amps 10 KA - 29 Nos Make-Legrand/Siemens/Schneider. (d) Smart electronic prepaid single phase Meter tamper proof, static meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC. - 29 Nos Make-L&T/HPLor other equivelent. (e) Digital type Voltmeter ( 0-500 Volts), 3 phase, 4 digit, high resolution, LED type with onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (f) Digital type Ampermeter ( 0-300 Amps) three phase with copper wound CT coil assy of suitable ratio & size Class I accuracy, 0.5 VA burden & onsite programmability- 01 Nos. Make: Securemeters, Reshab or L&T. (g) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases. (h) Tinned copper bus bar strips made of copper of size 40x5mm suitable length-(01Set of four) including provision of new vision glasses-29 Nos. (j) Submain cable 2 core 6 Sqmm copper conductor from MCB SPN to each Meters. (k) Making good the disturbed surface of meter cabin room if any damages occures during fixing/shifting of panel.
Note :- (i) Before fabrication of panel the contractor has to take approval from accepting officer on drawing. (ii) All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. (iii) Tking out old electronic energy meters from existing Meter panel and shall be deposited to MES store.
OM SAI POWER SYSTEMS
SHREE JAGDISH FURNITURE CO.
NOEL ENGINEERS
Darpan Construction
AGRAWAL ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .