Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC MOHALLA KAMA KHAN WARD NO 07 HOUSE NO 88 DISTT POONCH J K | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.9 L+₹1.6 L (6.12%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹29.8 L+₹3.4 L (13.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹29.8 L+₹3.5 L (13.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹29.8 L+₹3.5 L (13.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
SPL REPAIR TO BLDG NO T-16 AND T-28 (KOTE) AT JHALLAS UNDER GE 881 EWS
2022_MES_551883_1
GE/PNH-49/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE 881 EWS
₹77,000
Yes
17 Dec 2022
14 Sept 2022
20 Oct 2022
14 Sept 2022
13 Oct 2022
29 Sept 2022
Amount
B&R PORTION:- Dismantling plain or corrugated asbestos sheeting, any gauge, thickness, in roof covering complete all as specified and directed.
Dismantling of timber scantling 40sqcm and over in section unframed work,as in any position, complete all as specified and directed.
Dismantling mild steel work of any description complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and directed.
Taking down cement plaster of any description on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkhats with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) any thickness including cover fillets complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work, complete all as specified and directed.
S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified and directed.
S&F rolled mild steel works as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle, channel or flat sections) including distance pieces, cleats etc Fe 290(Gde E 165), complete all as specified and directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples; chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, valley gutter and similar works fixed with self tapping screws complete all as specified and directed.
M&L for two coats of synthetic enamel painting on new steel surfaces over 10cms width or girth over a coat of red oxide primer etc complete all as specified and directed.
S&F Suspended false ceiling using E- board suspended ceiling grid system of grid size 600mmx600mmx4mm incl fixing of frame work made up of special section MS galvanised sheet with zinc coated cellular intro painting and consisting of angle cleats of size 25 mm wide, 1.6 mm thick with flag fixing to the ceiling with dash fastener 12.5mm x 40 mm long or with 2 mm dia GI wire or fixed with bolts in GI channel main runner 35 x 25mm sheet thickness 0.5mm, cross runner 25 x 25mm sheet thickness 0.5mm for fixing E-board incl fixing of E-board with ceiling section and perimeter of channel 25 x 25 x 1mm thick, 27 mm high flange of 20mm to 30mm long extra, complete all as specified and directed.
M&L for walling of random rubble stone/boulder masonry brought upto course, well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
All as per Srl item No. 18 above but except stone complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base and flooring, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/Rectagular) area of each tile exceeding 0.18 Sqm but not exc 0.38 Sqm in floor etc, set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including cement screed bed 15 mm thick in cement mortar 1:6 base complete all as specified and directed.
All as per Item No 22 above but as in skirting/dados including 10mm thick screed bed in CM (1:4), complete all as specified and as directed.
M&L for 20-22 mm thick machine cut Kota stone slab flooring, bedded and jointed with grey cement slurry and pointed with grey cement with admixture or pigment to match the shade of Kota stone slab as approved by GE, laid over and including screed bed or bedding layer of mortar 20mm thick in Cement Mortar (1:6) including cutting, grinding and mirror polishing complete all as specified and directed.
All as per Item No 24 above but as in skirting/dados including 10mm thick screed bed in CM (1:4), complete all as specified and as directed.
M&L for 300x300mmx25mm thick chequered cement concrete tiles set and jointed in neat cement slurry and pointed in white or coloured cement mixed with mixture of pigments to match with the colour of tiles laid over and including 20mm thick screed bed in CM (1:6), including demolition of existing floor tiles complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) laid in alternate bays (not exceeding 2 sqm each) as in plinth protection, finished the surfaces even & fair, including filled the joints with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-1(using 20mm graded crushed stone aggregate) as in surface channels and drains, complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:6 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick or stone masonry wall surfaces in cement mortar 1:4 and finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices plaster etc, and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of newly plastered / unplastered surfaces of wall including cornices pilaster etc, and applying two coats of OBD over & incl a coat 1mm thick wall care putty complete all as specified and directed.
S&F pressed steel frame of size 125X60mm for doors as per IS 4351 using PBI Sheet of 1.25 mm thick with double rebated including mild steel hinges medium weight 100mm long and 25X3mm flat iron in holdfast. tie bar including necessary fixing lugs, lock strike plate and fixing arrangement etc. complete all as specified and directed.
M&L for 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, section 8, clause 8.24 (a) complete all as specified and directed.
M&L for 35mm thick 2nd class hardwood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered paticle board medium density, wood patilcle board with commercial face veneers complete all as specified and directed.
S&F Steel windows or ventilators comprising of tubular frame and shutter made out of 1.25mm thick pressed steel frame with glazed & gauged shutters (combination), side hung / top hung type with or without glazing bars as directed including box type / projecting type hinges and steel peg stay, handle, MS tower bolts 150mm long for each leaf and 8 mm square grill/guard bars at spacing as directed and welded to MS flat iron frame work, PCC blocks for hold fast etc complete all as specified and directed.
M&L for plain cement Concrete 1:3:6 type-C1 (using 20mm graded crushed stone aggregate) as in copings, hold fasts plinth band, bed blocks and like slightly rounded or chamfered angles as directed including necessary form work, complete all as specified and directed.
S&F 300mm ordinary rat tail mild steel rod pattern springs including roller and roller plate, complete all as specified and directed.
S&F Mild steel butt hinges, medium weight, cold rolled, 50mm long complete all as specified and directed.
S&F Second class hard wood small fittings such as brackets of any type, latch and hinges blocks, shaped doors and windows stops and the like, including all necessary labour, articles not exceeding 200 cu.cm each complete all as specified and directed.
S&F aluminium anodized barrel tower bolt of extruded section and fixed complete of size 150 mm long complete all as specified and directed.
S&F aluminium alloy handles, cast type, anodised of size 150 mm and fixed, complete all as specified and directed.
S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
S&F Sheet glass, ordinary quality, 3mm thick and glazed with oil putty or wooden beads, in square n exc. 0.5 Sq m each pane, complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed.
S&F in repair 25 mm dia MS powder coated tubular curtain rails, fancy type complete all as specified and directed.
S&F in repair MS powder coated, decorative type knobs with bracket of fixing at end of pelmet rod suitable for 25 mm dia, complete all as specified and directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer on new untreated wooden surface of any description, not otherwise described over 10 cm width or girth, incliding preparation of surfaces complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
Taking down carefully unsv main switch / DBs alongwith MCBs any type / capacity and making good disturbed surface to match with the existing surface, complete all as specified and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One light controlled by 2, two way switches 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per srl item No 53 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole, two way, (ISI marked), complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 5 pin, 6 Amp flush type, complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 6 Amp flush type, complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 6 & 16 Amp flush type universal, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair LED street light fitting 35 Watt cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB SPN 6-32 amps, breaking capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair MCB single pole 6 to 32 amps, capacity 10 KA, 'C' series complete all as specified and directed.
S&F in repair submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable, 1100 volts grade of size 4 Sqmm (nominal area) each and one single core 4 Sqmm cable as earth continuity conductor to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover complete all as specified and as directed. Note : Three runs of 4.00 Sqmm cable and one run of PVC conduit shall be measured as on unit
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
Supply, laying and testing of cable in trenches/ poles XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 16 sqmm including taking down complete all as specified and directed.
M&L for sand cushioning to UG cable 8 cm thick before laying and 15cm thick after laying complete all as specified and directed. Note: 1.Dry fine sand of best available quality shall be used. 2.Punned down thickness of 18 cm shall be measured and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth for foundation etc for shafts, wells,cesspits, man holes, pier holes etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil, complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
S&F in replacement of GI pipe light grade 40 mm bore for cable protection fixed on poles or laid in trenches, under floor, ducts etc with fixing clamps, nuts bolts etc complete all as specified and directed.
ROMESH CHANDER GANDOTRA
M/S BADRI NATH GUPTA
M/S KEWAL KRISHAN SANJEEV KUMAR VAID
SUNIL KUMAR SANGEET KUMAR AND SONS
VIKAS ENTERPRISES
NATIONAL TRADING COMPANY
M/S KIRAN CONSTRUCTIONS
Modh Hafiz Khan
M/s Anil Engineers & Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .