| 1 | L-1₹1.2 CrAccepted-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.2 Cr+₹2.3 L (1.87%)Rejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | ₹1.2 Cr+₹2.3 L (1.87%) | L-2 | Rejected-Finance Other than L-1 |
| 3 | L-3₹1.2 Cr+₹3.6 L (3.00%)Rejected-Finance | ₹1.2 Cr+₹3.6 L (3.00%) | L-3 | Rejected-Finance Other than L-1 |
| 4 | L_4₹1.4 Cr+₹19.6 L (16.2%)Rejected-Finance | ₹1.4 Cr+₹19.6 L (16.2%) | L_4 | Rejected-Finance Other than L-1 |
| 5 | L-5₹1.5 Cr+₹32.8 L (27.2%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹1.5 Cr+₹32.8 L (27.2%) | L-5 | Rejected-Finance Other than L-1 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
5 Feb 2022, 6:00 pmClosed
Sh A K Dubey IDSE SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO P-1 (1-8), P-2 (1-8), P-3 (1-4), P-4 (1-8), (TOTAL 28 X ACCNS) BEING USED AS OR MD ACCN AT WKSP MORH OF 14 EME BN (COMD) UNDER GE (NORTH) UDHAMPUR
2021_MES_492921_1
CA NO CWE/U(N)-82/2021-22
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE NORTH UDHAMPUR
₹2.0 L
Yes
25 Feb 2022
7 Dec 2021
7 Feb 2022
7 Dec 2021
5 Feb 2022
27 Jan 2022
Amount
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished even and smooth without using extra cement as in slabs facias, chhajjas and the like, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 6 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 8 above but of frame size 105 mm x 60 mm.
M&L Factory made 2nd class hard wood 35mm thick flush door shutter solid core with particle board exterior grade as per IS-22002 of 1983 (Part-I) flush door shutter shall be lipped decorative / commercial / designer faces on both sides as per relevant clause of SSR Part-I. Flush shutter solid panel construction with both commercial/designer, complete all as specified and directed by Engr in Charge.
Description all as per item No 10 above but gauzed and skeleton shutter with sash bar for glass/wire gauge.
Powder coated (not less than 50 micron) aluminium frames for door/ windows/ ventilators of approved design with one or more rebated including jointing cleats with all fixing arrangement in repair, complete all as specified and directed by Engr-in-Charge.
Powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc., complete, all as specified and directed by Engr in Charge.
Supply and fixing of powder coated aluminium grill of 5 to 6 mm dia size of mesh not exc 7.5 cm in either direction (deco grill - 104) including aluminium channel, complete, all as specified and directed by Engr in Charge.
Providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for, filling as in the pressed steel door frame/hold fast complete all as specified.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
4mm thick Sheet glass, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old wooden or wood based surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint , complete all as specified.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
Mild steel butt hinges medium weight cold rolled, 100mm size, complete all as specified and directed.
Mild steel butt hinges medium weight cold rolled, 75mm size, complete all as specified and directed.
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
100 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and as directed by Engr-in-Charge.
Mild steel, 300 mm, ordinary rat tail rod pattern door spring including roller and roller plate complete all as specified.
Vitreous china water closet, 'Orissa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision,fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 incl PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete, all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat Part No AV-8965/ Cera Cat Part No F1018201 or equivalent make as mentioned in Particular Specifications.
Brass chromium plated shower rose 125mm size with arms, round shape, swivel type, Chrome plated fixing in repair, complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No ALTON SHR22040/ Cera Cat Part No F7010102SS or equivalent make as mentioned in Particular Specifications.
Stop valves, fancy type, chromium plated, cast copper alloy, with long shank and cup (concealed type) screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm fixing in repair , complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No FLR-5083NK ABS-4 inch/ Cera Cat Part No F4050102 & F1018351 or equivalent make as mentioned in Particular Specifications.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No CAN-CHR-1111NM/ Cera Cat Part No B2210106 or equivalent make as mentioned in Particular Specifications.
Soap dish, vitreous China white, approximate size 160x 160x90mm complete, in repairs, complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No CAN-CHR-113N/ Cera Cat Part No S9010109 or equivalent make as mentioned in Particular Specifications.
Bib taps , fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No OPP-CHR-15037PM/ Cera Cat Part No F1017151 or equivalent make as mentioned in Particular Specifications.
CP mixture 15 mm bore for mixing hot & cold water for wash hand basin, screw down for iron pipe, complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No CON-CHR-169KNB/ Cera Cat Part No F2008461 or equivalent make as mentioned in Particular Specifications.
15mm bore wall mixer, non telephonic shower arrangments with connecting legs & wall flange , complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No CON-CHR-219KN/ Cera Cat Part No F1017401 or equivalent make as mentioned in Particular Specifications.
S&F for sink mixer with regular swining spout wall mounted with connecting legs & wall flanges, complete all as specified and as directed by Engr-in-Charge.Make : Jaquar Cat Part No CON-CHR-309KNB/ Cera Cat Part No F1016501 or equivalent make as mentioned in Particular Specifications.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Machine cut single piece kota stone slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Machine cut single piece kota stone slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including over 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified and as directed by Engr-in-Charge.
150mm wide strip of makrana white marble 18-20 mm thick as in shelves, cupboards etc. machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified.
Glazed coloured ceramic jointfree/rectified tiles of size 300x200mm /450x300mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished rough for receiving tiles, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over & including 15mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge
Preparing newly plastered or unplastered surfaces of wall and applying two coats of exterior weather coat emulsion over a coat of suitable primer, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of new plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty (JK Birla) including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed by Engr-in-Charge.
RCC 1:2:4 type B-1, using 20 mm graded crushed stone aggregate. as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
RCC 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and as directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exceeding 20 cm wide, etc. to obtain rough flat finished surface of concrete complete all as specified and as directed by Engineer-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions etc, square, ractangular or polygonal, to obtain rough finished flat surface of concrete complete all as specified and as directed.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as direceted by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, upto 100 mm internal dia jointed in cement mortar and taking out of trenches or fixed to wall, if required complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, all as specified and as directed by Engr-in-Charge.
Description all as per item No 72 above but 75 mm bore pipe.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 mm bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 mm bore, fitted with oval access door as in repairs complete all as specified and as directed.
Stack clamps out of 50mm by 5mm flat iron and 16 mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and as directed.
Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, all as specified and as directed by Engr-in-Charge.
Description all as per item No 78 above but 75 mm bore pipe.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, but except brick complete all as specified and as directed by Engr-in-Charge.
50 mm thick, Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in sub base to floor finishes , complete all as specified and as directed by Engr-in-Charge.
18/19mm thick Prelaminated particle board, termite proof, chemically well pressed, exterior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified.
Continuous ( piano) hinges mild steel ,bright finish or electrogalvanised , width of flap (when open ) 30mm , complete all as specified.
Rotational moulded polyethylene water storage tank , three layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10cm and not exceeding 20 cm girth complete all as specified and directed.
S&F in repairs 25 mm dia SS antique type curtain rods with bracket fixed to wall with suitable screws and onion type end brackets all as per approved design/colour/pattern fixed as directed in Engr-in-Charge.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 25 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
25 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Applying bituminous primer on roof surfaces @ 0.3 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
Applying two coats of aluminium paint on roof complete all as specified & directed by the Engr -in-Charge.
Plate rack made of stainless steel,900 x 1000X200mm including fixing as per manufacturers instruction complete all as specified.
Stainless steel sink , 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor, complete all as specified and as directed by Engr-in-Charge.
Factory made, Machine pressed / vibro mechanically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with glossy finished, with topping of cement with imported pigment including 25-30 mm thick sand cushioning bed including spreading levelling watering if required, Shape shall be approved by Engr-in-Charge.
Chequered Cement concrete glossy finish terecota tiles 20cm x 20cm and 25mm thick, machine pressed; set jointed and pointed in neat cement slurry with grey cement and in floors, and cut and polished , over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed by Engr-in-Charge. complete all as specified. complete all as specified.
Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including concrete bedding and haunching complete all as specified and as directed by Engr-in-Charge.
Concrete bed to drain pipes of 150mm to 300mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregates, complete all as specified and as directed by Engr-in-Charge. NOTE: Thickness of bed is 10 cm and width of bed is 30 cm plus external dia of pipe.
Concrete bed to drain pipes of 200mm bore, including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregates, complete all as specified and as directed by Engr-in-Charge. NOTE: Thickness of bed is 10 cm and width of bed is 30 cm plus external dia of pipe.
Reinforced concrete pipes 150mm bore ,class NP2,laid and jointed complete with coller all as specified and as directed.
Reinforced concrete pipes 200mm bore ,class NP2,laid and jointed complete with coller all as specified and as directed.
Precast RCC M-25, design mix (using 20 mm graded crushed stone aggregates) in cover slab, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and necessary form works, and setting in mortar 1:6 complete with joints to match complete all as specified and directed by Engr-in-Charge. Note : Design/Sectional detail of RCC structure shall be decided by Engr-in-Charge as per ground requirement.
Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling, sub base and mass concrete all as specified.
Extra for forming fair finished drain or channel exc 30cm inner girth in cement concrete ,using extra cement ,incl forms moulds ,mitered/stopped ends etc
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as requiredcomplete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitious composite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours, including taking down old/existing treatment with wire brusing and clearing the dust and foreign material before new treatment, complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of acrylic based polymer modified cementitious composite compound or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for modular type switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn into and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with and also including 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 118 here-in-before but for one bell/buzzer controlled by one push button on the independent board complete all as specified and as directed
All as per description of Serial item No 118 here-in-before but one 3/5 pin 5 Amp socket outlet on independent board , complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 118 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 118 above but for light point controlled by 2-two way switch
Description all as per item No 118 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Switch piano type 5 Amps single pole one way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole two way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole ,fixing in repairs, complete all as specified and as directed by Engr-in-Charge.
Bell push 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Taking down old serviceable/ unserviceable LED lighting fixture 4/5W, 10/12W, 18/20W and Bulk Head fitting 9/10W from existing position carefully refixing including making good to disturbed surfaces , complete all as specified and as directed by Engr-in-Charge.
Refixing of existing Slim linear LED lighting fixture 4/5 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
Refixing of existing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete., complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the directions of Engr-in-Charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging all as per the directions of Engg-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.
Contd Srl item No 137...... (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down old serviceable/ unserviceable MCB/ DB of any type and capacity with MCB etc after disconnecting for reuse for credit , complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions , complete all as specified and as directed by Engr-in-Charge.
MCCB 4 pole, 415 volts 160 Amps with breaking capacity 16 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications , complete all as specified and as directed.
MCB SP, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
Taking down old serviceable/ unserviceable Electric meter including meter box from existing position carefully refixing including making good to disturbed surfaces , complete all as specified and as directed by Engr-in-Charge.
Re-fixing only,serviceable Electric meter including meter box as obtained against item No 137 complete including minor repair to existing fitting occure while dismentling, complete all as specified and as directed by Engr-in-Charge.
Refixing of existing Slim linear LED lighting fixture 20 Watt LED Batten, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge.
Refixing of existing Bulk Head Light 9/10 watt LED energy saving with IP65 complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of any cap from 5 to 32 Amps of breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 16 sqmm 4 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed by Engr-in-Charge.
Refixing of 15mm bore steel water tubing medium grade galvanized with and including all fittings including short lengths etc., fixed to walls, concealed in wall and ceiling or laid in floors complete with all fittings such as tees, bends, elbows, short pieces, caps and plugs, unions etc complete all as specified and as directed by Engr-in-Charge.Old 15 mm bore steel water tubing obtained from Srl Item No 93 shall be re-used.
Refixing of 20mm bore steel water tubing medium grade galvanized with and including all fittings including short lengths etc., fixed to walls, concealed in wall and ceiling or laid in floors complete with all fittings such as tees, bends, elbows, short pieces, caps and plugs, unions etc complete all as specified and as directed by Engr-in-Charge.Old 20 mm bore steel water tubing obtained from Srl Item No 94 shall be re-used.
Refixing of 25mm bore steel water tubing medium grade galvanized with and including all fittings including short lengths etc., fixed to walls, concealed in wall and ceiling or laid in floors complete with all fittings such as tees, bends, elbows, short pieces, caps and plugs, unions etc complete all as specified and as directed by Engr-in-Charge.Old 25 mm bore steel water tubing obtained from Srl Item No 95 shall be re-used.
M&L for removing all loose scale and corrosion deposits of the exposed corroded steel including surface preparation, corroded steel should be cleaned all around including the back of exposed reinforcement with the clearance/ gap between steel & concrete as recommended by manufacturer, then applying rust remover with brush by complete wetting the material surface by rust remover & leaving for 24 hrs and thereafter surface preparation of coated bars and applying 2nd coat of rust remover & leaving the same for the specific period as per manufacturers instructions and further again preparing and cleaning the steel surfaces for treatment complete all as spd & directed by the Engr-in-Charge. Make :- Sika Rustoff 100/ Fosroc Rebacklens/ BASF Emaco S420 or equivalent.
Corrosion Resistance Coating: M&L for applying passivator/ anti corrosion coating to the prepared reinforcement steel surfaces of items No-158 above. The materials shall be cement based polymer modified coating for corrosion protection and shall be applied aqs per manufacturers instructions. Make:- Sika Armatec 108/ Fosroc Nito cole AP-35/ Equivalent in BASF. Note:- Site for application is at various locations and height varies up to 15.0M Proper stable Scaffolding is must for working.
M & L for preparation of old RCC/concrete surface and applying a coat of (two components solvent free) epoxy bonding agent using brush after cleaning of surface from all dust or laitance all as per manufactures instructions and as dir by Engr-in-Charge. Make : Sika Siadur 32 LP/Fosroc Nitobond EP/Equivalent in BASF Note : Site for application is at various locations and height varies up to 15.0M Proper stable scaffolding is must for working.
Providing and applying ready to use single component high strength polymer modified cimentious repair mortar 25 mm thick with water/powder ratio as specified by manufactures so as to achieve the following parameters :- (i) 28 days compressive strength >=50N/nm2 (ii) Flexural strength at 28 days >=5N/nm2 Make :- Sikatop 122 HS/Fosroc Nito Mortars/Equivalent in BASF Note : Site for application is at various locations and height varies up to 15.00M Proper stable scaffolding is must for working .
Curing compound :- M&L for applying high efficiency water based film forming curing compound over the fresh concrete cementious surface to form a continuous non-penetrating coating providing ad barrier to moisture loss ensuring more efficient cement hydration, improved durability and reduced shrinkage. The compound shall be applied by sprayer only as per manufacture instructions to ensure complete and proper coverage, pump pressure should be maintained to give an even fine spray and finish as per the manufacturer specifications.
M&L 1 mm thick external wall care putty on newly plaster surface for only item Nos 158 to 162 above, complete all as specified and directed by Engr-in-Charge .
Taking down serviceable/unserviceable electric water heater including all connection pipes from existing position carefully and refixing the same including making good to disturbed surfaces (Note : Disturbed surfaces should making good by plastering/distempering/color washing/white washing to match with existing surfaces and required fastener bolt) complete all as specified and as directed .
Notes:- For Srl Item No 01 to 164: The rates include for items of surfaces finshes Bldg upt G+3 height above all external/ internal surface finishes and the following:- 1. Use of all scaffolding, trestles, ladders, cradles etc. necessary for execution of work and protective measure for. 2. Removing of nails, making good holes, cracks etc. 3. Work in patches, and in narrow/ widths, bands, cornices, plasters etc and cutting in edges to line where necessary. 4. Spreading and removing covering to doors, windows, floors, fitting etc to protect them from splashes. 5. Removing and replacing furniture, movable cupboard, chicks, blinds, etc washing floors, cleaning glass, joinery, electric fittings, wiring, etc of drops and splashes and leaving premises, clean and tidy.
M/s Khajuria Construction Co.
d d builders
M/S Inderjit Sharma and Co.
R K BUILDERS
Mehar Enterprises
M/S VED PARKASH GUPTA
JINDAL BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .