Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹20.6 L+₹66,755.50 (3.34%)Rejected-AOC HOUSE NO 3809 SAMRIDHI HOMES PEERMAUSHALA POST DHAKOLI MC ZIRAKPUR DISTT SAS NAGAR PIN 160104 | S A S NAGAR | PUNJAB | 160104 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹20.9 L+₹91,488 (4.58%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹21.7 L+₹1.8 L (8.87%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
₹20.9 L
EMD Value
₹41,800
Closing Date
25 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-04/2020-21 ADD/ALTN TO BLDG NO P-13 AT NCVD AND CERTAIN REVENUE WORK UNDER AGE B/R-II OF GE NORTH UDHAMPUR
2020_MES_342355_2
GE/U(N)-04/2020-21
Open Tender
Civil Works
Item Rate
240 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹41,800
Yes
16 Jul 2020
4 Jun 2020
27 Jun 2020
4 Jun 2020
25 Jun 2020
11 Jun 2020
60 days
Amount
Demolition of cement concrete (un reinforced) in ground floor and paving n. exe 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.50m deep and n.exe 1.50 in wide and getting out in any type of soil ., complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and directed by Engr-in-Charge. .
Hard core of broken stone or boulders of gauge not exc 63mm deposited, spread & levelled in layers not exc 15cm thick, including watering and ramming to a true surface complete all as specified and directed by Engineer-in-Charge. NOTE :- Volume of hard core after consolidation will be measured and paid.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface as in hard/dense soil, complete all as specified and as directed by Engr-in-Charge.
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge..
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge..
PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified and directed by Engineer-in-Charge.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete (design mix) M-25 ( using 20mm graded stone aggregate) in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc basement slabs, under reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M-25( using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts & struts etc complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete(design mix) M-25( using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M-25( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed by Engineer-in-Charge..
Use & waste of Form work to sides of concrete foundation, footings, bases of columns raft and raft beams, side and soffits (if any) of foundation and plinth beams, and similar work vertical or to batter for flat rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of Form work to sides of pillars, posts, struts, pears and stanchion square or rectangle or polygonal for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with rough finished surfaces of concrete, complete all as specified.
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. Exc 200mm thick, and flat fair finished surfaces complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking , bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
All as per item No 21 above but 5mm dia and over upto and including 10mm dia as in stirrups spacers and binders.
Framed work as in door or gates of angles or other section with gusset plates/rails/ braces etc complete drilled for fixing of steel sheeting or other covering door etc to be prepared for hanging or sliding with & including either hooks, complete all as specified and directed by Engr-in-Charge. .
Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-W (Gde- E-250) quality- B, complete all as specified and directed by Engr-in-Charge. .
Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-410-W (Gde- E-250) quality- A, complete all as specified and directed by Engr-in-Charge. .
Steel Windows Box type hung shutters including projecting type hinges with steel handle, & steel peg stay, complete with glazing bars with fixing of oil putty all as specified & directed by Engr-In-Charge.
Steel Windows Box type hung shutters including projecting type hinges with steel handle, & steel peg stay, complete without glazing bars all as specified & directed by Engr-In-Charge.
Galvanised mild steel wire cloth,0.63mm nominal dia of wire & average width of aperture 1.40mm & fixed with tinned tacks or galvanised wire staple all as specified & directed by Engr-In-Charge.
3 mm thick sheet glass ordinary quality & glazing with oil putty inh square n exc 0.50 sqm in each pane all specified & directed by Engr-In-Charge.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410
Power Coated door air tight of anodised frame made of size 100 mm x 45mm of section thickness -1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick tinted glass as in panels shutter rail made of 80mm x45 mm of sheet thickness 1.50 mm (Top and bottom rails and stiles) single /double leaf side hung type including necessary jointing cleats /anodised aluminium fillets/ glazing clips with rubber gasket ,with aluminium fittings such as aluminium anodised tower bolt 200mm long 03 No for each door, aluminium anodised bow handles 150 mm 'D' type 02 nos for each shutter , mortice locks 6 lever make - harrison one on each door, door shutter mounted on bottom double action floor spring hydrailically regulated made up of 1.25mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing mild steel heavy duty and door shutter top mounted on aluminium alloy pivot. -01 No on each shutter , bottom and floor stoppers, Complete all as specified. Note : All fitting shall be of ISI marked except cleats ) sizes of each door shall be as per site requirement all as directed and specified .
Aluminium power coated partition of section (44x44)mm & vertical members (44x44) with top,bottom, with vertical members (44x44)mm with 3 ft spacing of each post vertically & horizontaly specing 75cm,5.5mm thick tinted glass/decorative PVC board, all beading rubber gasket & complete builder hard ware , complete all as specified and as directed by Engr-in-Charge.
12 mm thick Plywood,grade BWR,type BB, fixed with screws & timber frame work/iron frame, complete all as specified and as directed by Engr-in-Charge.
Decorative laminate type 1, 0.9mm thickness for surface finish,colour & pattern as approved pattern, Fixed with approved adhesive as per manufacture instruction , complete all as specified and as directed by Engr-in-Charge.
Door closer hydraulically regulated, (aluminium die cast body) designation No. 3, universal type, suitable for door shutter of 851 to 1000mm in width & of weight between 61 to 81 kg & fixed, complete all as specified and as directed by Engr-in-Charge.
Sheet glass, 5.5mm thick ordinary quality & glazing with oil putty in square exc 0.5 sq.m in each pane including necessary jointing cleats /anodised aluminium fillets/ glazing clips with rubber gasket, complete all as specified and as directed by Engr-in-Charge.
Aluminium window air tight of power coated frame made of size 100mm x 45mm of section thickness-1.50mm thick and shutter stiles made of section 80mm x 45mm x 1.5mm thick with or without rebates, with 5.5mm thick tinted glass fixed with aluminium beads, including GAUZED AND GLACED SHUTTER, necessary jointing cleats/anodised aluminium fillets/alluminium glazing clips with rubber gasket, with aluminium fittings such as aluminium butt hinges 100mm long 03 Nos, aluminium anodised tower bolt 100mm long 02 No, aluminium anodised bow handles 100mm 01 No, aluminium hook and eye 150mm 01 No in each shutterm including aluminium grill of 5 to 6 dia, size of mesh not exc 7.5cm in either direction, as approved by GE, complete all as specified. Note:- All fitting shall be of ISI marked except cleats ) sizes of each shutter shall be as per site requirement all as directed and specified .
Anodised Aluminium door air tight of power coated frame made of size 100 mm x 45mm of section thickness -1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick tinted glass as in panels shutter rail made of 80mm x45 mm of sheet thickness 1.50 mm (Top and bottom rails and stiles) single /double leaf side hung type including necessary jointing cleats /anodised aluminium fillets/ glazing clips with rubber gasket ,with aluminium fittings such as aluminium anodised tower bolt 200mm long 03 No for each door, aluminium anodised bow handles 150 mm 'D' type 02 nos for each shutter , mortice locks 6 lever make - harrison one on each door, door shutter mounted on bottom double action floor spring hydrailically regulated made up of 1.25mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing mild steel heavy duty and door shutter top mounted on aluminium alloy pivot. -01 No on each shutter , bottom and floor stoppers, Complete all as specified. Note : All fitting shall be of ISI marked except cleats ) sizes of each door shall be as per site requirement all as directed and specified .
Pre-painted galvalume aluminium zinc cozting GI based corrugated steel sheet 0.50 mm thick of any colour having Profile of sheet to be mentioned tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and screw not less than 03 nos each sheet, complete all as specified and directed by Engineer-in-Charge.
Dismantling floor , hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises, all as specified.
Plain Cement concrete 100mm thick 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floors finished even and rough complete all as specified and directed by Engineer-in-Charge.
Plinth protection 50 mm thick in PCC 1:3:6, type C-1 ( using 20 mm graded crushed stone aggregate ) laid in alternate bays (not exceeding 2 Sqm each) finished even and fair at top and providing joints through out the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as directed at site.
25 mm thick plain cement concrete 1:2:4 type B-0 ( using 12.50 mm graded stone aggregate) as in sub bases of floors finished even and fair.
Vitrified ceramic light shade coloured tiles 9-10mm thick (Square/rectangular) polished area of each tiles size 600x600mm laid in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge
Glazed ceramic tiles 450 mm x 350 mm x 7to8mm/350X250X7mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing coat, complete all as specified and directed by Engineer-in-Charge.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 , complete all as specified and directed by Engineer-in-Charge.
Granite(any type), 18-20 mm thick, (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms and like including laying of 15 mm thick screed bed or bedding layer in CM 1:4 and bedding/ screed pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
60 mm thick glossy rubber mould interlocking machine pressed precast concrete (paver blocks red & yellow colour topping) any shape finished type conforming to IS-15658-2006,M -35 Grade laid dry over and including 30 mm compacted sand bed, size & pattern of tiles all as directed by Engineer-in-Charge.
Priming the roof surface with bitumenous primer conforming to IS-3384 @ 0.3 Ltr/Sqm and applying a coat of semi hot blown 85 / 25 grade blown bitumen @ 1.2 Kg / Sqm and thereafter supply and laying APP modified Polymeric membrane, five layered, of weight not less than 3 Kg per Sqm with centre layer core of 100 micron high molecular density polyethylene film and bonded completely to the surface with overlap of 10cm (overlap to be thermo fused by flame) followed by another coat of semi hot blown 85 / 25 grade bitumen @ 1.2 Kg / Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm including 2 coats of bituminus aluminium paint, complete all as specified and as directed. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
Rendering 15 mm thick on fair faces of concrete surfaces, finished even and smooth (without using extra cement) in cement mortar (1:4) for roof treatment , complete all as specified and directed by Engr-in-charge.
Supply only integral water proofing compound of approved quality, ISI Marked, complete all as specified and directed by Engineer-in-Charge.
15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), including integral WPC by wt of cement as per manufacturer instruction (NOTE : Supply only WPC will be measured and paid for separately), complete all as specified and directed by Engr-in-charge.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling,roof projection,chajja in cement mortar (1:3), complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces of walls and applying two coats of distemper with distemper oil emulsion white or tinted over including one coat primer, complete all as specified and directed by Engineer-in-Charge.
Two coats of cement base paint over a coat of primer on new/undecorated wall surfaces including preparation of surfaces, complete all as specified and directed by Engineer-in-Charge.
Preparing of new plastered or un-decorated surfaces and applying three of white wash on ceiling, complete all as specified and directed by Engineer-in-Charge.
Two coats of synthetic enamel paint over & including a coat of pink primer over new wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over pre-primed surfaces, complete all as specified and directed by Engineer-in-Charge.
Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc primer, complete all as specified and directed by Engineer-in-Charge.
Plastic water closet seat cover ,white/ black,closed pattern with flats bottom and cover and mild steel chromium plated or aluminium hinging device,of approved make and quality etc complete.
S/F Aluminium Grill fixed to aluminium window all as specified & directed by Engr-In-Charge.
Vitreous china wash down water closet pan (pedestal pattern) white, (excluding flushing cistern and flush pipe) with 100mm CI ‘P’ or ‘S’ trap including sheet cover close pattern with flat bottom, CP jet and connection to trap and to flushing pipe etc, complete all as specified and directed by Engineer-in-Charge.
10 ltrs PVC valve less syphonic action type flushing cistern low level (white) with inlet, ball valve float and handle including PVC Connection and 32mm dia PVC long bend for squar pattern etc. set with concrete and making good to floor , complete all as specified and directed by Engineer-in-Charge.
Viterous china Urinals, half stall large coloured including connection PVC waste pipe of adequate dia and size CP grating with hole and urinal push valve including fittings , complete all as specified and directed by Engineer-in-Charge.
Chromium plated shower rose fancy type 125mm dia, swivel type suitble for 15mm bore fitting , complete all as specified and directed by Engineer-in-Charge.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes with pedestal of china ware, complete all as specified and directed by Engineer-in-Charge.
Vitreous china wash hand basin white, oval type of size 520mmx450mm fixed (for hospital use ) and including cast iron cantilever bracket of size 65 x65x 6mmembedded in PCC block with PCC 1:2:4 type B-1 and 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including waste fitting and pedestal of chinaware etc , complete all as specified and directed by Engineer-in-Charge.
Rotational moulded polythene water storage tanks 3 layer (cylindered vertical closed top ) hoisted and fixed in position including necessary connection nipple suitable for inlet, outlet and overflow pipes, all as specified in SSR Part –I of capacity of tanks 500 ltrs , complete all as specified and as directed by Engr-in-Charge.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore, complete all as specified and directed by Engineer-in-Charge.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule & fixed
15mm Bib taps, cast copper alloy, fency type chromium plated, with crtuch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type ,screwed down high pressure, with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe of dia 15 mm , complete all as specified.
PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-Charge.
CP fancy type mixture tap of std quality for mixing hot & cold water as approved by Engr-in-Charge. with centre hole mixer with fittings, complete all as specified and directed by Engineer-in-Charge.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 20mm dia., complete all as specified and directed by Engineer-in-Charge.
Stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm dia., complete all as specified and directed by Engineer-in-Charge.
Towel rail 600mm long aluminium tower bolts 20mm D type, complete all as specified and directed by Engineer-in-Charge.
Jets to EWC`s with long jet pipe (flexible) and connections etc, complete all as specified and directed by Engineer-in-Charge.
Concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete all as specified and as directed. Note:- (i) Thickness of bed belew barrel of pipe -10 cm. (ii) Width of bed :- outer dia of pipe plus 30 cm.
150 mm Reinforced concrete pipes, class NP3 laid and jointed with collars, laid in trenches and jointed in cement, complete all as specified and directed by Engineer-in-Charge.
Cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands coping/cills/ benching, bed plates bed block etc for embedding hold fast including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
Precast cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:6, complete all as specified and directed by Engr-in-Charge. .
Cement concrete 1:2:4 type B-1 ( Using 20 mm graded crushed stone aggregate ) as in surface channel or drain etc, complete all as specified and as directed.
Extra for forming fair finished drain or channel upto 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and directed by Engr-in-Charge. .
Cutting into exising manholes for connecting new drains (internal dia of pipe n.exc 200 mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) smooth finished, and reforming benching , complete all as specified and directed by Engr-in-Charge. .
Supply and lay in replacement XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cuttingof bituminous road/chasing to any surface and making good to the disturbed surface to match the existing.
Dry sand cushioning to under ground cables provided with a layer of sand 8 cm deep before laying the cable, 15 cm depth after laying cable & stretching the cable all as specified and directed.
Supply and lay brick class ‘B’ covering as mechanical protection to cable with well burnt all as spec.
GI tubing light grade with all fitting and fixed in wall and floor or fixed to pole of size 40mm dia.
Cutting of road n.exc 45 Cm depth, and n.exc 30 Cm width for laying of GI tubing for protection of cable ncluding making concrete in ground floors and paving all as per existing all as directed .
Point wiring concealed with 1.5 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), drawing in and including PVC concealed conduit 20 mm dia,cutting chases wall & ceiling and making good to disrurbed surface of wall ,ceiling etc,having wall thickness not less than 1.50 mm with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc), including 1.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for one light /Fan point/Exhaust fan controlled by one switch one way complete all as specified and directed.
All as per description of Serial item No 94 here-in-before but one 3 pin 5 Amp socket outlet on Independent board, complete all as specified and as directed by Engr-in-Charge.
All as per item Srl No 94 herein before but for 3 pin socket outlet 5 Amps on same board, complete all as specified and directed by Engr-in-charge.
All as per description of Serial item No 94 here-in-before but one 3 pin 5/15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete, complete all as specified and as directed by Engr-in-Charge.
Modular Switch one way 10 Amps 01 Module, 240 volt grade , complete all as specified and as directed.
Modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Modular socket 6 amp-2/3 pin combined 2 module complete all as specified and directed.
Modular Socket 6A/16Amps 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge.
Ceiling Rose Surface backilte 65x20mm size two/three terminal ISI marked complete
Modular Electronic fan regulator, step type, two module 60 watt 230 volt and making all necessary connections complete all as specified and directed.
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 1x36W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ syska CAT No SSK SQ2001
Slim linear LED lighting fixture 6W watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection from ceiling rose to fittings including testing complete all as per the direction of Engr-in-Charge. Make of LED -SYSKA as per ordering code SSK-T5-6W or equivalent model of Havells or CG
Sub main wiring with copper conductor cable (2 runs of cable) multistaranded 6 Sqmm PVC ISI marked with all insulated unsheathed in and including rigid PVC concealed conduit 25mm dia, 2mm wall thickness medium grade fitings including 6 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth duly complete including taking down of existing Submain wiring and making good to the distrubed surface of wall & match with existing surface of wall, complete all as specified and as directed by Engr-in-charge. Note: Two runs of 6 sqmm and one run of 6sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
Sub main wiring with copper conductor cable (2 runs of cable) multistaranded 4 Sqmm PVC ISI marked with all insulated unsheathed in and including rigid PVC concealed conduit 20mm dia, 2mm wall thickness medium grade fitings including 4 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth duly complete including taking down of existing Submain wiring and making good to the distrubed surface of wall & match with existing surface of wall, complete all as specified and as directed by Engr-in-charge. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity with indicator complete all as directed.
Supply and fixing 4mm dia GI wire as earth continuty conductor or main earth strip fix to wall on batten or recess or chess or burrid in ground or any other indicated situation for loop earthing etc.
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways. Make: Legrand (Ekinox3) cat no- 507612 Ekinoxe/ schneider(Acti-9)/ Siemens(Betagard-8GB 32).
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 ways. Make: Legrand (DX-3) cat no- 507611 Ekinoxe/ schneider(Acti-9)/ Siemens(Betagard-8GB 32).
MCB SPN 40 to 63Amps 240V 'C' series ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. Make: Legrand (DX-3) cat no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
MCB SP 06 to 32 Amps 240V 'C' series ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc. Make: Legrand (DX-3) cat no- 408587,90,92,93,94,95/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
Supply and hanging ceiling fan of 1200 mm sweep,2star rated white in colour including complete with provn of hanging, connection and testing all as specified and directed by Engr-in-charge.
Supply and fix on load change over switch 240 V , 50 Hz in shaeet metal enclosure Double pole of capacity 63 Amp Make Havells CAT Pt No- IHBFDE0063
M/S BHAGWATI ENTERPRISES
RAMAN KUMAR
jyoti parkash sharma
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .