Hyderabad Division: SC-MUE Section: Malkajgiri-Signalling and Telecomunication arrangements in connection with Doubling of Malkajgiri-Moula-ali Gate Cabin & (2) Malkajgiri-Signalling arrangement in connection with Malkajgiri Yard Remodeling: Provision of Down Loop Line and 02 additional lines.
Y-SG-36-2026-27-15
Y-SG-36-2026-27-15
Open
Works - General
18 Months
Hyderabad, Telangana
₹0
₹40.9 L
23 Jul 2026
23 Jul 2026
4 Aug 2026
Item Breakup - A-Schedule- A
Supply of 4.5m long CLS Post 140mm Numbers dia to Specn No. IRS:S 6-81 Rev.3 or latest (Inspection: RITES)
Supply of 3.5m long CLS Post 140mm Numbers dia to Specn No. IRS:S 6-81 Rev.3 or latest (Inspection: RITES).
Supply of CLS Ladder set complete with Set staging/ platform, supports, cast iron ladder base/Shoe - Ladder for 4.5m post as per Drg No. SA 23153, S 2033 or latest (Inspection: RITES).
Supply of CLS Ladder set complete with Set staging/ platform, supports, cast iron ladder base/Shoe - Ladder for 3.5m post as per Drg No. SA 23150, S 2033 or latest (Inspection: RITES).
Supply of Surface Base 140mm Dia CLS Numbers post as per Drg No. S 2011/M (Inspection: RITES).
Supply of Offset Bracket to suit 140mm Numbers Dia CLS post with two numbers of U bolts and nuts complete (Inspection: RITES).
Supply of Calling On Signal Unit Numbers complete with U Bolts as per RDSO Drg No. SA.24351 (Adv.) or latest (Inspection: RITES).
Supply of Junction type/Direction type Numbers route indicator as per Specn IRS:S 66-84 Amd.1 or latest-One way as per Drg No. SA 23401 (Inspection: RITES).
Supply of Junction type/Direction type Numbers route indicator as per Specn No. IRS:S 66-84 Amd.1 or latest - Four way to Drg No. SA.23404 (Inspection: RITES).
Supply of Ground type position light Numbers shunt signal complete with base, pipe, arrow mark and hoods as per RDSO Drg No. SA 23840 or latest (Inspection: RITES).
Supply of Post type position light shunt Numbers signal with hoods, arrow mark and offset bracket to suit 90mm sockets (CLS) with two numbers of 'U' bolts and nuts complete to fix shunt signal below main stop signal as per RDSO Drg No. SA 23840 or latest (Inspection: RITES).
Supply of 'E' type lock of specified ward Numbers as per requirement with one key E-type lock to Drg No. SA3376/ M or latest and Specn No. IRS: S30-64 or latest (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of relay fixing frame for full Numbers location box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx 3mm. The frame shall have suitable holes to fix in full location box (Inspection: Consignee).
Supply of GI termination box (10 SWG) Numbers for point machine of size 45 cmx23 cmx12 cm with double coat of enamel paint (outside: Black & inside: white) along with 2 Nos. of MS angle of size 50x50x6mm of length 1000mm each, 2 numbers of 40mm GI pipe of length 450mm & 150mm with nuts/washers and teak wood plank of size 40mmx 25mm for fixing of terminals (Inspection: Consignee).
Supply of Insulations for Ground Set connections; Insulations for D' clamp switch extension bracket to suit to universal point machine as per Drg RDSO/S3361-62 supplied by Rlys. One set consists of 'D' clamp insulation- 2 Nos., Nylon insulation bushes- 4 Nos., and Nylon insulation washers-8 Nos.) (Inspection: Consignee)
Supply of Insulations for Ground Set connections - Drive lug insulation for universal point machine as per Drg RDSO/S 3361-62 (One set consists of one number central insulation plate, bushes-2 Nos. and washer-4 Nos.) (Inspection: Consignee).
Supply of Insulations for ground Set connection for Point Machine comprising of the following: 1) Switch extension piece insulation -1 set (Each set comprising of S3265 -1 No.; S 3266-1 No; S23199-2 Nos. and S8640-4 Nos.) 2) Stretcher bar insulation-3 sets (Each set consisting of T10367-1 No., T10368-2 No., T10371-4 Nos.) 3) Gauge tie plate insulations-4 sets (Each set consisting of T 10372- 1 No., T10368 -3 Nos. and T10371-6 Nos.) 4) Drive lug insulation- 1set (Each set consisting of S 8804 - 1 No., S 8813 - 2 Nos. and S 8640-4 Nos.) complete with bushes. Note: The type of insulation required will be specified by Engineer in-charge of the work depending on the type of machine proposed (Universal/PTJ Make) as per specification (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Ground connection insulations Set for thick web switch layout facing point (BG) for 52 Kgs/60 Kgs rail fitted with high thrust point machine comprising of the following: 1. Bush as per Drg No. S3463-1no. and Washer as per Drg No. S8640- 2no. for drive (throw) rod 2. Bush as per DrgNo.S 23199-1no and Washer as per Drg No. S 8640-2no for short detector rod. 3. Bush as per DrgNo.S 23199-1no and Washer as per DrgNo.S 8640-2no for long detector rod. 4. Bush as per DrgNo.S 22179-1no and Washer as per Drg No. S 8640-2no for short lock rod. 5. Bush as per DrgNo.S 22179-1no and Washer as per Drg No .S 8640-2no for long lock rod. 6. Bush 'B' as per DrgNo.S 8912 for LH lock slide-1 no. 7. Bush 'B' as per DrgNo.S 8912 for LH lock arm-2 no. 8. Bush 'B' as per DrgNo.S 8912 for RH lock arm -2 no. 9. Bush 'B' as per DrgNo.S 8912 for RH lock slide-1no. 10. Bush as per DrgNo.S 23199 -4no and washer as per DrgNo.S 8640-4no for LH lock slide. 11. Insulating Plate LH as per DrgNo.S 3404 RDSO/S 3593- 1no. 12. Insulating Plate RH as per DrgNo.S 3404 RDSO/S 3592- 1no. 13. Bush as per DrgNo.S 23199-4no and washer as per Drg No. S 8640-4no for RH lock slide (Inspection: Consignee).
Supply of Track feed battery charger to Numbers work on 110V AC for charging 1 or 2 or 3 or 4 lead acid cell of 80AH (10 Amps) used in track circuit as per RDSO Specn No. IRS.S.89/2013 Ver 1.0 latest (Inspection: RDSO).
Supply of Galvanised Wire rope 6/19 Metre steel, 6mm Dia with fibre core as per Specn IRS-S-11 or latest (Inspection: Consignee).
Supply of Plug-in type miniature tractive Numbers armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per Specn BRS 930, IRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QN1-8F/8B, 24V DC. The interlocking code: ABCDF (Inspection: RDSO).
Supply of Plug-in type miniature tractive Numbers armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per Specn BRS 930, IRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QN1-12F/4B, 24V DC. The interlocking code: ABCDE (Inspection: RDSO).
Supply of 24V DC plug-in type miniature Numbers tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QBCA1 - 2HF/4B, Interlocking Code: BCEJK as per Specn BRS 943 or latest (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of 24V DC plug-in type miniature Numbers tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1- 8F/8B, Interlocking Code: ABDGH as per Specn BRS 931 A or latest (Inspection: RDSO).
Supply of 24V DC plug-in type miniature Numbers tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1-12F/4B, DC Neutral Line Relay, Interlocking Code: ABDFH as per Specn BRS 931 A or latest (Inspection: RDSO).
Supply of 24V DC plug-in type miniature Numbers tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QNA1K - 6F/6B, Interlocking Code: CDEKY as per Specn BRS 931 A or latest and RDSO letter No. STS/E/Relays/UEA (PI) dated 30/05/97 (Annexure-II) (Inspection: RDSO).
Supply of 24V DC plug-in type miniature Numbers tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 60-78 Amd.1 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) - QSPA1 - 8F/4B, The interlocking code: ABDEJ, Spec BRS 933A or latest (Inspection: RDSO).
Supply of AC immune, plug-in type, Numbers Style 'QTA2', 2F/1B DC Neutral track relay for Rly signalling track circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per Specns: BRS 939A & 966 or latest, IRS:S 23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable) with interlocking code FGHKX (Inspection: RDSO).
Supply of ECR 4F/4B' for 110V AC lit LED Numbers signals, complete with plug board, retaining clip and connectors as per RDSO Specn No. STS/E/Relays/AC Lit LED Signal/ 09-2002 Amd.1 or latest, BRS 941A, IRS: S 23-88 Amd.1 or latest, IRS: S34-68 Amd.6 or latest, IRS: S 67-85 Amd.3 or latest (as applicable). The interlocking code for this unit shall be ABDHK (with ATC clips) (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Fail-Safe Electronic Time Numbers Delay Device mounted on Q series relay band enclosed within Q series relay cover complete with plug board, retaining clip and connectors as per Specn No. IRS: 61-2000 Amd.3 or latest, IRS: S23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest IRS 67-85 (as applicable). The device shall work on 24V DC and shall give 24V DC output after the specified time delay - Time delay of 60 seconds. Interlocking code: AFHKY (Inspection: RDSO).
Supply of Fail-Safe Electronic Time Numbers Delay Device mounted on Q series relay band enclosed within Q series relay cover complete with plug board, retaining clip and connectors as per Specn No. IRS: 61-2000 Amd.3 or latest, IRS: S23-88 Amd.1 or latest, IRS: S 34-68 Amd.6 or latest IRS 67-85 (as applicable). The device shall work on 24V DC and shall give 24V DC output after the specified time delay - Time delay of 120 seconds. Interlocking code: AFGKY (Inspection: RDSO)
Supply termination rack of size 880mmx2075mm made using 50mmx50mmx6mm (6mm thickness) MS angles. The cable termination rack shall be supplied with stainless steel nuts and bolts for fixing the rack, tripod bases and reel insulators (for K rack, P rack and power rack), cable ladder of 400mm width and 2075mm length with two angles of size 40mmx40mmx 5mm (5mm thickness) and supporting flats of size 25mmx 25mm. Suitable holes shall be drilled to fit hylam sheet as per standard practice (Inspection: Consignee).
Supply of Terminal block: 1 way Poly Numbers butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO Drg No. SA23745/Alt.5 or latest, SA23746/ Alt.5 or latest, S23747/Alt.5 and Specn IRS: S 75-2006 Rev.2.0 (Tentative) or latest, IRS: S 23-88 Amd.1 or latest (Inspection: RDSO).
Supply of Terminal block: 6 way Poly Numbers butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO Drg No. SA23756/Alt.3 or latest, S23757/ Alt.4 or latest and Specn IRS: S75-2006 Rev.2.0 (Tentative) or latest, IRS: S 23-88 Amd.1 or latest (Inspection: RDSO).
Supply of modular terminal block Set (WAGO or similar) as per RDSO Specn RDSO/SPN/189/2004 Ver.3.0 or latest consisting the following parts: a) 2 conductor disconnect terminal block - 6 Nos. b) End/intermediate plate suitable for 2 conductor disconnect terminal - 1 No. c) Screw less end stop similar to WAGO Model No. 249-117 - 2 Nos. d) Insulated jumper WAGO Model 280-402 - 5 Nos. e) Din Rail - 0.1 metre per set (in length of 1 metre for every ten set) (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of non-deteriorating type of fuse Numbers holders and fuse links 240V AC/DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of E1 fuse link type (up to 20A) - Fuse holder 20A capacity (Inspection: RDSO).
Supply of non-deteriorating type of fuse Numbers holders and fuse links 240V AC/DC as per Specn IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of E1 fuse link type (up to 20A) - Fuse link 1A/2A/6A/10A/16A/20A as specified by Engineer in charge (Inspection: RDSO).
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 16/0.2 (16 wires, diameter of each wire is 0.20mm) (0.5sq.mm) wire coil as per Specn IS 694:2010 or latest, IRS: S 76-89 Amd.3 or latest. Length of coil should be 100m. Colour of coil to be specified by Engineer in charge (Inspection: RDSO). (Unit: Coil)
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 28/0.3 (28 wires, diameter of each wire 0.30mm) flexible wire coil as per Specn IS 694:2010 or latest, IRS: S 76-89 Amd.3 or latest. Length of coil should be 100m. Colour to be specified by Engineer in charge (Inspection: RDSO). (Unit: Coil)
Supply of 35 Sq.mm PVC insulated multi- Metre strand, single core, copper conductor 277/0.4 (277 wires, diameter of each wire is 0.4mm) cable as per IS:694 or latest, IRS: S 76-89 Amd.3 or latest. Cable to be supplied in 100-meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO).
Supply of 16 Sq.mm PVC insulated, Metre multi-stand, single core, copper conductor 127/0.4 (127 wires, diameter of each wire is 0.4mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO).
Supply of 10 Sq.mm PVC insulated, Metre multi-strand, single core, copper conductor 140/0.3 (140 wires, diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS: S 76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil (Inspection: RDSO).
Supply of Data Logger with 1024 digital Set inputs and 32 analog inputs capacity for remote monitoring of Signalling parameters and power supply arrangements with network as per Specn IRS: S 99-2006 Amd.3 or latest with 64 input digital card as a spare and fuse monitoring PCBs for monitoring at least fifty 2A fuses with inbuilt modem cards for networking (Inspection: RDSO).
Supply of Protocol Converter for Numbers Electronic Interlocking including software required for networking (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of 4 wire Train Traffic Control Numbers equipment with DTMF Signalling Way Station equipment and Way Station Control Telephone as per Specn IRS:TC 60-2007 Amd.1 or latest (Inspection: Consignee).
Supply of Push Button Corded Auto Numbers Telephone with Caller ID facility of Make: Beetel/Panasonic/Binatone or better (Inspection: Consignee).
Supply of Permanently lubricated HDPE Kilometre Duct with outer diameter of 40mm and inner Diameter of 33mm as per Specn RDSO/SPN/TC/45/2013 Rev.2.0. The length of the Duct shall be 1 km. Two end plugs shall be provided along with the drum (Inspection: RITES).
Supply of basic material to construct Set unit Maintenance Free Earth as per Specn RDSO/SPN/197 Ver.1.0 or latest consisting of the following: a) Copper bonded steel electrode 3m long, 17mm diameter with copper bonding thickness mini 250 micron and UL listed and marked - 1 No. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of minimum 10 Kgs - 3 Nos. c) Copper strip with dimensions 150x25x6mm to terminate earth rod - 1 No. d) Copper strip with dimensions 300x25x6mm Main Equi- potential Earth Bus bar (MEEB) - 1 No. e) Copper strip of with dimensions 150x25x6mm Sub Equi- potential Earth Bus bar (SEEB) - 1 No. f) 35 Sq.mm multi-strand PVC insulated Copper Cable (15 meter) (Inspection: RDSO).
Supply of Copper lugs 10 Sq.mm of Numbers reputed make (Inspection: Consignee).
Supply of Universal Locks with one steel Numbers key for every ten locks or part there of (For example, if locks ordered is 10, 1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19) (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Printing, binding & supply of the Numbers following Registers with latest proforma as given by Engineer in-charge. Each register shall be of 100 pages. (Unit: Register=number)1) Station Asset Register2) Deficiencies3) Officer Inspection Book4) Station Message Book5) Infringement Measurement Book for Signaling Assets6) Route Cancellation Register7) Relay Room Key Register8) Selection Circuit Testing Register9) Cable Testing Register10) Signal Maintenance Record11) Battery Maintenance Register12) Mechanical Signaling Register13) Axle Counter Maintenance Register14) SSDAC/HASSDAC/MSDAC Maintenance Register15) Block Instrument Maintenance Register16) Track Circuit Maintenance Register17) Mechanical Lifting Barriers Maintenance Register18) Electrical Lifting Barriers Maintenance Register19) Electrically Operated Point Maintenance Register20) Electronic Interlocking Maintenance Register21) Location Box Maintenance Register22) Earth Testing Record Register23) Joint Inspection of Points and Crossings Register24) Joint Inspection of Track Circuits25) Joint Inspection of Track Circuits with OHE26) Diesel Generator / Solar Panel Register27) UFSBI maintenance register (Inspection: Consignee).(Unit: per register )
Supply of complete set of ground Set connections for high thrust 220 mm stroke point machine along with insulation as per Drg No. RDSO/S3454 Alt.Bdt 25-01-2023 or latest along with insulation (Inpsection: RITES).
Supply of Double Walled Corrugated Numbers (DWC) HDPE duct of outer Diameter 180mm and inner Diameter 153mm of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The duct shall be supplied along with push-fit type O-ring coupler or end cap (Inspection: Consignee).
Supply of Thermo shrink jointing kit for Numbers jointing underground 0.9mm Dia conductor 6 Quad cable as per Specn IRS: TC 77-2012 Rev.3 (Amd.1 to Amd.3) or latest (Inspection: RDSO).
Supply of Q series Magnetically Latched Numbers (QLI) type Relay, 24V DC, complete with plug board with connectors and retaining clips confirming to BRS 935A and RDSO Specn IRS S:34 & IRS 3:23 or latest - QLI- IIF/4B, The interlocking code: ABDEG (Inspection: RDSO).
Supply of Metallic (MS) colour light Numbers Signal Unit-2 aspect complete as per Drg No. SA.23003/A/M (Adv.) with latest Amdt. andSpecn IRS: 5 26-64 or latest (Inspection: RITES).
Supply of Metallic (MS) colour liqht Numbers Signal Unit 3 aspect complete as per Drg No. SA.23002/A/M (Adv.) with latest Amdt. andSpecn IRS: S 26-64 or latest (Inspection: RITES). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Metallic (MS) colour light Numbers Signal Unit-4 aspect complete as per Drg No. SA.23001/A/M (Adv.) with latest Amdt. andSpecn IRS: S 26-64 or latest (Inspection: RITES).
Supply of 32 Channel NVR as per Specn Numbers RDSO/SPN/TC/ 65/2013 Ver.6 or latest (To be procured from RDSO approved firm) (Inspection: Consignee).
Supply of IP based day and night high Numbers resolution camera spec with IP 66 rated water proof, dust proof for outside application with RDSO Specn RDSO/SPN/TC/65/2013 ver. 6 or latest (Inspection: RDSO).
Supply of 10TB internal hard disc with Numbers power and SATA data cables suitable for 16 channel super NVR Make:Seagate/WD or better (Inspection: Consignee).
Supply of 19" - 42 U Rack complete with Numbers fittings for housing SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment like runaway ladders etc., as per Tech Specn below. It should be able to lock all the equipment with only order wire Telephone outside the rack. The rack should be of APW President/Rittal make or better. The components of the rack are specified below. It includes transportation and installation of rack in prefab/ building at specified stations. 1. Rack S33 42U 600'W x 600D - 1 No. 2. Fixed side panels 42U x 600 D - 2 Nos. 3. Front Glass door plain 42U/600W - 1 No. 4. Rear MS Door Plain 42U/600W - 1 No. 5 . Castor with brakes-2 Nos. 6 Fans directly mounted on the top 48V DC 90 CFM-2 Nos. 7. Krone mounting bracket - 01 No. 8. MCB Mounting panel with MCBs - a. 32 Amps, MCBs (DP) - 2 Nos. & 6 Amps MCBs (DP) - 6 Nos. 9. Earth continuity Kit - 01 No. 10. Equipment Trays - 5 Nos. 11. Channel with cable loops 42U - 2 Nos" (Inspection: Consignee).
Supply of Fuse Auto Changeover System Set of various types of fuses with audio visual indication as per Specn RDSO/SPN/209/2012 Ver.2.0 or latest. One module shall be able to cater for 32 Nos. of fuses (Inspection: RDSO).
Supply of Twelve channel Earth Leakage Numbers Detector (ELD) with configuration specified by Engineer in charge and as per Specn RDSO/SPN/256/2002 or latest with insulated tester, test probes, Mounting stand and Fuse board to isolate from distribution board as per requirement of channels (Inspection: RDSO).
Supply of Hylam sheet of size Numbers 2400mmx1200mmx6mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee).
Supply of Hylam sheet of size Numbers 2400mmx600mmx6mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Hylam sheet of size Numbers 2400mmx600mmx3mm, resin bonded, grade P3 as per IS Specn IS 2036 of 1974 or latest (Inspection: Consignee).
Supply of Ground connections for Set Universal Point Machine 143mm with 'D' type clamp for 52 Kgs/60 Kgs/90R rail as per Drg No. RDSO/S3267-74 (Inspection: Consignee).
Supply of Track lead junction boxes fibre Numbers glass as per Drg No. CWM-00597 of FRP material to and Specn IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx 5mm, 0.9m long, two numbers of Gl pipes of 25 mm Dia, 500 mm long along with nuts and bolts and 500mm long (grommet bushes, 60mm ARA terminals-2 Nos.) (Inspection: Consignee).
Supply of B type chokes to as per Specn Numbers IRS: S65-83 Amd.l or latest (Inspection: RDSO).
Supply of 2V, 80AH Stationary Low Numbers Maintenance Secondary Lead Acid Cells as per RDSO Specn IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs (Inspection: RDSO).
Supply of Hydrometer as per IS: 3104 Numbers (Part II)-1982 or latest (Inspection: Consignee).
Supply of Distilled water for topping of Litre Secondary cells as per Specn IS 1106 or latest (Inspection: Consignee).
Supply of Porcelain Insulators for Numbers Secondary Lead Acid Cells (Inspection: Consignee).
Supply of Track Feed Regulating Numbers Resistance disk type 0 to 30 as per Drg No. SA 20161 66/M or latest. To be procured from RDSO approved firms (Inspection: RDSO).
Supply of 60 core Indoor Cable with Kilometre 0.6mm conductor Diameter as per Specns IS 694:2010 or latest, IRS: S 76- 89 Amd.3 or latest (Inspection: RDSO).
"Supply of Battery Charger of capacity Numbers 230V AC/110V DC, 30A single phase, Signalling/Telecom. Installation as per Specn IRS: S 86-2000 Amd.4 or latest (Inspection: RDSO). Total 25416498.00
Item Breakup - B-Schedule-B
Location survey for cable route and Route Kilo Meter preparation of tentative cable route plan (RKM) as per the instructions of Engineer in- charge. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Excavation of trench Depth of 1200mm Route Kilo Meter and width of 300mm, including marking (RKM) of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer in- charge
Excavation of trench Depth of 600mm Route Kilo Meter and width of 600mm, including marking (RKM) of cable alignment, clearing of jungle, roots of trees, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO /CABLE LAYING/003, as directed by Engineer in-charge.
Cutting of Rock, concreting after cable RMT laying with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, except in bridges, culverts, level crossings, track crossings, cable pits and rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by Engineer in- charge. All the material is to be arranged by Contractor - Depth of 200mm and width of 200mm where rock is visible from surface to a depth more than 300mm up to 550mm, excavation of trench with width 300mm above rock, concreting 200mmx 200mm after laying of cable as per Drg No. SK/CN/NEW/3.
Cutting of Rock, concreting after cable RMT laying-When rock is visible for more than 0.5 Meter and up to 0.8 Meter from ground level, excavating the trench minimum 0.5 Meter and maximum 0.8 Meter, laying cable and concreting 200mmx200mm over the rocky surface after levelling with soil/sand (Chase cutting not required).
Track Horizontal Boring method at culverts/track/pucca road as per SCR Drg No. 5770. This also includes insertion of HDPE pipe of 110mm /GI Pipe of 100mm in the bore drilled (HDPE pipe/GI pipe is to be supplied by Rly). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Trenching under Rails for crossing the RMT track (Track Crossing) and refilling of trenches as per SCR Drg No. 5768. The track crossing shall be done at right angles. The depth of cable trench shall be 1.2 meter below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of Supervisor of S&T and Supervisor of P.Way.
Breaking of metal/tar road and refilling RMT after laying the cables as per Drg No. SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
Cable laying and meggering - Laying RMT different type of cables in the trench. Termination covered elsewhere.
Excavation of coil pit up to a depth of 1 Numbers meter and Dia of 1.5 meter for providing coil at location box, point, signals etc. This includes back filling and ramming of trench/pit after laying the cable and consolidation of soil.
Supply & laying of GI Pipes of 100mm RMT Diameter with medium and threaded collar & coupler, quality to Specn IS.1239 (part-I) 1990 and galvanised to Specn IS.4736- 1986.
Supply, transporting & installation of Numbers Concrete (RCC) Route Indicators at intervals of 50 meters as per instructions of engineer in charge as per Drg No. SK 12/10. They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing. In case of telecom quad cable joint locations it shall be painted with GREEN and ORANGE colour for normal indication of cable path. (Inspection: RITES)
Providing & laying in position cement cum concrete of specified grade including the cost of centring and shuttering: 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
Supply, placing & covering of RCC duct RMT from Home to Home as per SCR Drg No. 5778 (Inspection: RITES). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Excavation of pit, casting concrete Numbers foundation & erection of apparatus case Full size as per SCR Drg No. 5781 and fixing of 1 No. of 'E' type lock for the front door, latching arrangement for backdoor, fixing of Hylam sheet (Hylam sheet supply is covered elsewhere and Wooden Reapers also can be used in place of Hylam sheet for which supply & fixing covered elsewhere) and painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside including painting of termination, equipment and number particular on location box (foundation bolts and nuts, 'E' type lock, cement, river sand, stone jelly of size 20/20mm, paints, varnish, fixing bolts and nuts and all other miscellaneous material required for the work shall be supplied by the Contractor).
Test lamp arrangement in LBs/RE Numbers cuttings (Auto mobile handle type).(Unit: Per location)
Supply & fixing of Teak Wood Reapers Numbers after applying two coats of wood primer suitable for Full Box: 75mm width x 20mm thick and length of 940mm. (Unit:Per Reaper)
Supply & fixing of Teak Wood Reapers Numbers after applying two coats of wood primer suitable for Full Box: 50mm width x 50mm thick and length of 940mm and clamping the cable.(Unit:Per Reaper)
Supply & fixing of Hard wood Planks for Numbers keeping Equipment in the Full Box: 940mmx20mmx300mm approximately after applying two coats of black enamel paint.(Unit:Per Plank)
Supply & fixing of Teak Wood planks of cum sizes as instructed by the site in-charge with smooth finishing surface to be provided where ever required such as in location boxes relay room, equipment room and battery room, Fine wood polish of approved quality to be applied for two times after thorough application of emery paper. Fixing bolts and wood polish supplied by the Contractor. (Inspection: Consignee).
Supply & fixing Hard Wood planks of cum 40mm thick and not less than 200mm width with smooth surface, and painting with black enamel paint painting (Hardwood, paints, fixing bolts is to be arranged by Contractor) (Inspection: Consignee).
Cable terminals, fuses, LDs, Meggering of cables and recording the readings.
Fixing relay bases, wiring in location Per Relay boxes, bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way/1 way terminals/WAGO, ND type fuses, LED indicators for fuses as per type fuses.
Supply, painting & fixing of gland plate Numbers for Location box as per site requirement - Full Location Box. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fixing of Tie Bar Fencing panels supplied Metre by Rlys duly transporting to the site (Goomties/Mid section Locations) from Centralised location. Cutting, drilling, jointing with nut and bolts wherever required as per site requirement for protecting goomties/location boxes. After fixing of the tie bar, panels to be painted with two coats of aluminium paint and levelling the earth wherever required. All required materials other than tie bar fencing panels should be arranged by the Contractor/Agency. (Unit:Per metre)
Fabrication, supply & erection of Numbers conventional Earth to Signalling/Telecom equipments-Excavation of earth and providing earth pipe of size 50mm Dia 3.5mm thick 2.0 m. long GI pipe of heavy quality with masonry tub constructed around at earth locations as specified by site Engineer. Alternate layers of 30 Kgs-charcoal and 30 Kgs- common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per Drg No. SK 10/ 10. The earth pipe to be connected to the function with cable as supplied by Rlys. The reading should be painted on the masonry tub. The masonry tub of 300mmx300mm x300mm (along with Kundi) should be covered with cement slab ((Inspection: RITES).
EMI/Earthing arrangements to achieve Numbers earth value less than 1 Ohm (minimum 8 maintenance free earth) for EI at central location or end Goomties for object controllers as per RDSO Specn as required for the EI system as per Rly Board letter No. 2010/Sig/SGF/EI (Ansaldo) dated 22.06.2011 or latest shall be followed. All materials shall be supplied by the Contractor including Maintenance free earthing (Inspection: RDSO).(Unit: Per Location)
Supply & installation of "FRANKLIN ROD" Numbers as per NFPA- 780 Standards. Installation to be done as per SCR Drg No. 5777. It also includes connection of down conductor with Franklin Rod and running of down conductor through PVC pipes and connecting the same to nearby earth electrode. All material required for installation to be supplied by the Contractor (Inspection: RDSO).
Earthing and soldering of cable armour Numbers as per instructions of site incharge.(Unit: Per cable) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation of single earth (maintenance Set free) including the following: Welding and fixing of copper tape (used as bus bar) welding of cadmium bronze cable to copper plate using material supplied. All the material supplied for mounting of copper tape, exothermic weld materials, tools and fixtures for welding copper tapes shall be arranged by Contractor. a) Digging/Auguring/Boring of single earth pit of 100mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with earth enhancement compound (EEC) in slurry from and backfilling. d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 150X25X6mm. e) Carrying out exothermic weld connection on the copper tape of 150X25X6mm on earth electrode for connecting two 35 Sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0 .5 Mtr. and run the two 35 Sq mm earth conductor (procured against supply item) from earth pit to MEEB. h) Routing and termination of two 35 sq mm earth conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs. i) 300X300X300 mm (inside dimension) concrete earth pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and earth resistance value shall be written.
Routing & connecting all the equipments RMT in the equipment /relay room to MEEB/SEEB with 16/10 Sq mm copper cable using copper lugs with stainless steel nuts and bolts and fixtures. The work includes laying and routing the copper cable in PVC pipes/conduits and fixing them on wall as directed by engineer in charge. PVC pipes/ conduits will be supplied by Rly.
Provision MS flat connection from Earth RMT pit to LBs/Signals including supply and laying of MS Flat of size 40x6mm at site, supply of GI bolt of size M12X40mm with two Nuts along with two plain washers and one spring washer, drilling of holes in MS flat of different sizes at site, cutting with bending and twisting of MS flat as required at site, painting of MS Flat with one coating of red oxide as primary and two coats of anti-corrosive black paint and drilling of holes in Location Boxes at site (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Welding for jointing MS flat 6mm thick X Per Weld 40mm width of different lengths strips connecting from Earth to location boxes/Signal post/Signal Unit for better continuity. Prior approval of welding material to be taken from Engineer In charge.(Unit:Each weld)
Foundation & erection of Colour light Numbers signal which includes a) Excavation of pit, casting concrete foundation as per SCR Drg No. 5772 using metallic templates, for erection of Colour light Signals 4 aspects (foundation bolts, cement, river sand, stone jelly of size 20/20mm Dia and all other miscellaneous materials required for the work shall be supplied by the Contractor). b) Erection of surface base, signal post, mounting of Colour Light Signal up to 4 aspects complete on signal post/offset bracket, LED fixing, plumbing of the signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, termination tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of aluminium/enamel paints. When the aspect is fixed on offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling of hole in the signal pole to prevent the offset bracket from sliding down. (Supply of surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, current regulators and wire coils will be supplied by Rlys). ('U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Colour Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves, enamelled number plates, enamelled marker boards, EWS locks and all other miscellaneous materials for the work shall be supplied by the Contractor).
Foundation & erection of Shunt signal Numbers which includes; a) Excavation of pit and casting concrete foundation as per Drg No. SG/CN/02/10 using metallic templates, for erection of ground type colour light Shunt signal. (Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor). b) Erection of Ground type shunt signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/enamel paint, (Supply of Ground type shunt signal complete including surface base, signal post, LED unit is to be supplied by Rlys). [EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fixing of offset bracket using 'U' bolts Numbers and nuts erection of posts type shunt signal, wiring of LEDs, termination of tail cables, provision of EWS lock, fixing of number plate and painting of one coat of red oxide and two coats of aluminium/enamelled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the offset bracket from slipping down (Supply of Post type shunt signal, LED unit is to be supplied by Rlys). [EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor).
Fixing of Offset brackets using 'U' bolts Numbers and nuts, erecting of Calling On Signals/'A' marker lights, termination of tail cables and wiring, provision of EWS lock, number plates/ markers boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Calling On Signal/'A' marker light, LED aspect/holders and bulbs, wire coils and off set brackets will be supplied by Rlys). ['U' bolts and nuts, through bolts with nut, EWS lock, Enamelled number plates, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor.
Manufacturing, supply, painting & fixing Each of markers of G/P/C/A/AG/IB Markers as per IRSEM Drg No. 19-D10 on MS sheet of thickness 3mm. Miscellaneous material required for fixing Markers is to be supplied by Contractor.
Provision of SCREEN on signals when Numbers they fall within 2 meters from the live conductor by expanding metal (size 20mmx60mm strand 3.25mm wide and 1.6mm thick) as per the instruction of site engineer in charge. This includes supply of all materials including connection with earth electrode as per SCR Drg No. 5767.
Supply and fixing of cross bar on signal Numbers (signal not in use) made of hard wood of size 1000mmx100mmx20mm. The cross bar shall be painted white as per Signal Engineering Manual. All material required for installation shall be supplied by Contractor.
Fixing of universal point machines and Numbers wiring on PSC/ Wooden sleepers as per standard drawing. Wiring as per circuitry includes fixing & wiring of point contactor unit frames and controlling relays, fixing and wiring of point termination box, fixing of crank handle ward plate of required configuration and Ground connections, P-clamp insulations, setting, stretcher bars etc. [All miscellaneous material required such as nuts, bolts, washers are to be arranged by Contractor]. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation, termination of cable in Per Point termination box, wiring, testing and Machine commissioning of High Thrust point Machine. This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc.
Wiring of Track circuits feed end, relay Numbers end complete with TLDs, batteries, chargers, Chokes, track relays, double lead wires, providing insulation etc. Connected with track commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangement has to be done for chargers & batteries. All miscellaneous material required for installation shall be supplied by Contractor.
Drilling of four Nos. of 7.2mm holes, per Each rail joint on web of the rail, providing bond wires with wire rope. (Bond pins single groves are to be supplied by Contractor - Wire rope for bonding will be supplied by Rlys). (Unit: Per Rail Joint)
Supply, erection & fixing of retro Numbers reflective type BPAC Warning boards/IBS Legend Board of size 1000x600x3 mm. The boards shall be provided with Retro Reflective type BPAC Warning boards. MS Angle, stone jelly of size 20/25mm Dia, river sand, cement, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor. (Inspection: Consignee).
Provision of foundation for the signal Numbers warning boards/ calling on boards/all types of boards. (A pit of size 400mm x400mmx1500mm is to be dug and cement concrete foundation in the pit in the ratio 1:3:6 to be casted. The rail post/MS angle is to be erected up right in the foundation.
Supply, installation & wiring of KLCR Numbers relay 24V DC AC immunized with 4F/4B contacts. This also includes termination of cable and required wiring in KLCR box (Inspection: RDSO).
Fabrication & supply of Box suitable for Numbers 8 No's KLCRs as per instructions of site incharge (Inspection: Consignee).
Fixing of approximately 200 Nos. of 6 Set way/1 way terminal block horizontally on 6mm Hylam sheets which in turn to be fixed to rack with all supports as per instructions of SSE in charge. Materials such as bolts, nuts and supporting flats to be supplied by the Contractor only.
Cutting & fixing of Hylam sheet of 6 Lumpsum mm/3mm thickness to suit to 1 way relay rack and fixing the following with Contractors screws, bolts a n d nuts and fixing strips, condensers and resistances of various values - 50 Nos. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fixing of non-deteriorating fuse holders Numbers with LED indications and resistors and negative terminal strips on 6mm Hylam sheet with Contractors screws, bolts and nuts.
Installation, testing & commissioning of Numbers Data Logger which includes the software configuration, validation, taking test print, networking to nominated location for monitoring, changing of EPROMS if any and alterations to data base in HQ/SSE offices where ever required.
Fabrication, configuration of key for point machine for grouping of crank handle as per instructions of site in charge.
Fabrication, supply & installation of Numbers MSDAC/LC gate control cum indication panel of size 30" X 12" (MS sheet type) complete with LED etc., painting, screen printing of gate plan, signals etc., and prewired with four signal knobs and SM's control. All material required shall be supplied by the Contractor (Inspection: Consignee).
Provision of Lookout person round the Man-Days clock in 12 Hours shift beat from Up Home Signal to Down Home signals to avoid theft of signalling assets.
Provision of one skilled and 2 unskilled Month staff round the clock to attend to teething trouble of the installation along with SI/CSI after the installation has been brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the SI/CSI. Unit: per month
Releasing of existing apparatus cases Numbers (Full/Half/Quarter size) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Rly representative at site.
Dismantling & releasing of existing Numbers Colour light Signals complete (up to 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Rly representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
Dismantling & releasing of existing Point Numbers machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Rly representative at site. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Straight through/derivation with/without Each transformer joints: Installation Thermo shrinkable jointing kits for straight through/derivation joints for LC gate, pump houses etc where VF transformers are not required and derivation joint by using 2T transformer (to be housed in the joint). This includes tapping of nominated Quad at a specific location shown by the Rly Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the Contractor. (Unit: per joint)
Laying of HDPE duct 40/33 mm dia in Kilometre the trenches and in protective works already provided.
Blowing of armoured optic fibre cable Kilometre (OFC Cable supplied by Rlys) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE duct from one chamber to another chamber is to be replaced by the Contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.
Excavation of jointing pit and provision Numbers of RCC/FRP joint /Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom cover with hole for drainage and cable entry as per Drg No. RAILTEL/SR/OFC/2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc. The chamber shall be filled with sand mixed with anti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning.
Fixing of junction type Route Indicator - Numbers 1 way to 6 way - complete/fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor] - 4 way route indicator.
Provision & laying cement concrete Sqm (including transportation of all the material) - Centring and shuttering. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Manufacture, supply & fixing of Sighting Numbers Board (size 535mmx1800mm) with higher intensity grade, retro- reflective sheet on 2mm Aluminium alloy, sheet 14 gauge (0.6 Sq.mm/LC) as per Drg No. SK/13/89 with MS angle of 75x75x6mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. (All necessary materials to be arranged by the Contractor).
Circuit diagrams issued by the Rlys of Each (A-2 size) are to be taken on reproduction tracing film and manually entering the relay contact number and other required circuit details if any. (Reproduction tracing film and other consumables are to be arranged by the Contractor). (Unit: pet sheet of A2 size)
Preparation of A-3 size drawings as at Each site. Providing one print on tracing paper on in standard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness. (Polyester tracing film and other consumables are to be arranged by the Contractor). (unit: per sheet of A3 size)
Preparation of A-4 size drawings as at Each site. Providing one print on tracing paper on in standard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness. (Polyester tracing film and other consumables are to be arranged by the Contractor). (unit: per sheet of A4 size)
Arranging rexin cloth bound booklets Each and binding. (Unit: per booklet)
Documentation-"Design of SIP in Auto Set CAD. Initially, Contractor shall submit 3 copies for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, three Hard copies to be submitted for Rly Approval. After approval, Auto CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Five-Line Station.
Preparation of Table of Control based on Per Route SIP issued in Auto Cad in A3 size. Initially, Contractor shall submit 2 sets of document for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, two sets of Hard copies to be submitted for Rly approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and two sets of final approved drawing in properly bound booklet along its scanned copy. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Design in Auto CAD and submission of Set two draft copies of Complete Outdoor Particular such as Cable Route Plan, Cable Corage Plan, Cable Termination Rack/Power Rack Particular, Track Bonding, and Location Box Particular along with NI wiring/NI Relay Disposition chart. One copy will be returned either duly approved or for resubmission for approval after incorporating the changes as required by Rlys. After approval, one approved Tracing film copy & six copies (Ammonia Print or print as approved by Rly) of above drawings along with six copies of SIP and SWRD in Plastic Covers. All above drawing to be scanned including SIP & SWRD, bound in 6 different booklet with Rexin Cover (Each booklet shall have minimum 10 spare plastic transparent sheet) and a soft copy to be submitted in a Pen Drive for following categories of Stations for a Mid-Section LC Gate (Up to 15 Location Boxes).
Design of Circuit Diagrams for a Mid- Each Section LC Gate in Auto CAD consisting of the items as mentioned below & submission of Three paper copies for approval; (i) Wiring Diagrams, (ii) Relay Disposition Charts, (iii) Contact Analysis and Fuse Particulars, (iv) Termination, Chart for Panel Interlocking, (v) CT Rack Particulars (unit: per LC gate)
Design of SWRD in Auto CAD. Initially, Set Contractor shall submit 3 copies for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, three Hard copies to be submitted for Rly approval. After approval, Auto CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Five-Line Station. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply & installation of programmable Numbers Primary Digital Drop Insert Multiplexer fully wired for 30 Channels complete with all accessories from RDSO approved vendor as per RDSO Specn IRS TC 68-2012 Rev.0 (with latest amendment) including connectors and cables required for installation including 100 pair Krone type MDF. Eachchannel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to mm. 60 Channels without additional power supply unit. The MUX shall be wired & equipped with following circuits: 1) 2 Wire/4 Wire E&M VF circuits (Minimum 16 Nos. Ckts) 2) FXO circuits: 6 Nos. 3) FXS circuits Subs/Hotline circuits along with ringer card etc.: 08 Nos. 4) Acquisition card as per design 5) Data User manual. 6) This also includes connecting all pigtails, optical patch cords etc to the SDH equipments. This also includes connection of SDH and primary MUX equipment with all interface cards to the 48V Bus including termination on DDF taking PVC cable over runway or a wall and termination of VF interface circuits to the Krone Termination box. (Inspection: RDSO)
Supply, commissioning of managed expandable rack type STM-4, equipped STM-1, ADM S1.1, as per Tech Specn No. GR No.: TEC/GR/TXISDA-003/ 02/APR-2010 with 2 Nos. STM-1 aggregate Optical interface upgradable to STM-4, 21 Els, and minimum 8 Nos. of 10/100 base T Ethernet port, Order wire, Power supply unit, sub rack, DDF, Installation materials, manuals and other accessories. The equipment should be TEC/BSNL/RDSO approved. The equipment should be fully wired for its ultimate capacity and provide redundancy for Power supply and Synchronisation. It shall be possible to use the full capacity of the equipment by adding additional tributary cards. The up gradation of STM-1 to STM-4 shall be without change of any internal hardware of the STM equipment. The STM equipment shall have in-built L2 switch for Ethernet ports. Make: Tejas or better. (Inspection: RDSO)
Installation, calibration & commissioning Set of Earth Leakage detector 8 to 12 channels as per instructions of engineer in charge
Cable laying & Meggering of cable laid, Each before and after laying (before closing of trench). (Unit: per cable) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Cable Room/Goomties of 1.8m Dia and 1.2 meter depth consisting of brick work of 254mm thickness of proportion 1:6 with sand filling after coiling of cables. The top of sand filling covered with concreting of size 1.3 meter Dia and 200 mm depth of proportion 1:1.5:3. Outside of the duct should be plastered with cement mortar in a ration of 1: 6 to achieve smooth finishing. All materials including cement, chips of size 20 mm and second class bricks etc. to be supplied by the Contractor.
Laying of the HDPE/DWC/Gl pipe using RMT couplers and bends as per Drg No. SK.15/11, drawing of cables through the pipe and refilling of the trench duly putting back the removed ballast in its proper place and shape.
Clearing jungle including uprooting of Sqm rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of cleared jungle to a distance of 50 m outside the periphery of the area cleared (Measurement is to be done as per area cleaned).
Filling boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Rly premises as instructed by Rly representative at site.
Excavation 450mmx450mmx450mm and concreting the same with 1:3:6 aggregate 20mm for erecting the tie bar fencing panels, curing and white washing the foundations.
Fabrication & supply of powder coated Numbers (of approved colour) MS frames for Location boxes of size 955x155mm and made of L angular of size 25x25x3 mm to suit 'Q' series relays duly drilling required holes for relay bases (All materials such as frames, bolts, nuts and washers to be supplied by the Contractor).
Fixing of junction type route indicator - 1 Numbers way to 6 way - complete/fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor] - 3 way route indicator. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Strengthening of foundations of signals, Sqm Full/Half location boxes up to a height of 30 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
Fabrication configuration for points - Fabrication, fixing of required configuration of grouping plate in point machine for grouping of crank handle.
Provision arrangement during Non Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Rly representative at site. all other miscellaneous material shall be supplied by Contractor.
Fixing of Track lead junction box on Numbers angles (50x50x6mm size), drilling one hole on either side of the box of suitable size and fixing track lead junction box by the side of the track, drilling 4 holes of 7.2 mm Dia on Rail, connecting double track leads with bond pins, running track lead wire, termination of track lead wire on ARA terminals duly fixing the same inside the TLJB Teak wood board bolted inside the track lead junction box. (Fixing angles, bolts, nuts and teak wood boards to be supplied by the Contractor).
Initial Charging of Secondary Cells with Numbers uninterrupted Power Supply - 2 volts 80 AH.
Hiring of tarpaulin tents & providing the Each same at places as instructed by Rly representative at site. The spacing inside the tent shall be app 18ftx12 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans. The tents shall be fixed firmly to withstand rain, strong wind etc. (unit: Per Tent Per Day)
Painting of particulars of Glued Joint on Numbers rails/track circuit no. on TLJ boxes as per particulars issued by Engineer in charge. Before painting on surface of the Glued Joint Rails /TLJ boxes shall be cleaned thoroughly. Painting shall be done with approved quality of standard paints like Asian /Johnson/Nicholas/Berger etc. All the men and materials shall be arranged by the Contractor and the colours scheme shall be as per the instructions of Engineer in charge. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fabrication, Supply and fixing of Calling Numbers On Instruction boards, Stop Boards/BSLB/Shunting Limit Board/Auto section board or any other board with engineering grade reflective sticker of size 600x1000 mm GI sheet, with MS angle of 75x75x6mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the Contractor) (Inspection: Consignee).
Fixing of PVC pipes & bends, drawing of Lumpsum required wires through the same up to functions like Control Telephone, Dy.Control Telephone, Magneto Phones inside SM's office as per Circuit Diagram. This includes supply and fixing of required DPDT and rotary switches, PVC pipes and bends 25mm Dia with 2mm wall thickness, Lightening dischargers and painting of particulars.
Erection of CT Rack/Relay Rack l way/2 Each way/4 way with scaffolding suitably concreting tri-pod bases using J-bolts, fixing rack support of size 50x50x6mm on to the wall. Reel insulators are to be provided for insulating the rack from the scaffolding & tri-pod bases.(unit: Per oneway Rack) )
Preparation of Contact Analysis for 'Q' Each style relays as per detailed Tech Specn. (unit: per relay)
Fixing relay bases on the relay frames Numbers erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/multi core cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailed Tech Specn. Numbered ferrules shall be provided for each wire. Different colour codes and sizes of wire to be used as per standard practice. This also includes, provision of all PVC sleeves required to be provided. Copper lugs to suit to 16/02 wire and neat bunching, lacing with Modi Nylon/Twine thread and using PVC dotted tape with buttons. This also includes soldering all the wires in the relay room with Rosin core of IS Spec 1921 60% Tin and 40% Led). Soldering should be done as per standard practice. This also includes inserting the clips, point to point testing as per the circuit diagram and plugging relays to Relay bases (except Inter- cables, relays other materials such as Rosin core, flux, nylon thread. PVC dotted tape should be supplied by the Contractor). Point to point testing should be done in the presence of Engineer-in- charge as instructed in two stages, one before soldering and the other after soldering.
Alteration simulations in Data Loggers and all connected places (like HQ, FEP, Station etc.). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Implementation, commissioning per station of point reversal alarm.
Fabrication, supply & installation of NI Numbers panel of size 12"" x 24"" x 12"" made in 18 gauge MS sheet (Inspection: Consignee).
Fixing of LEDs along with Jewels, Numbers Resistors, Sleeves duly drilling holes and soldering including drawing of wires, bunching and lacing. (All materials to be supplied by the Contractor).
Transportation of materials from any Each Stores to Site and viceversa including loading and unloading - Lead up to 50 Kms. (unit: PTPK)
Testing and commissioning the entire Station Signalling installations jointly with the Rly representative at site at the Stations/LC gates/lBS/Auto Signalling covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. Testing and commissioning of Stations (up to 5 roads).
Documentation-"Design of SIP in Auto Set CAD. Initially, Contractor shall submit 3 copies for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, three Hard copies to be submitted for Rly Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Seven-Line Station.
Design of SWRD in Auto CAD. Initially, Set Contractor shall submit 3 copies for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, three Hard copies to be submitted for Rly approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Seven-Line Station. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Design of Cable Route Plan (Distant to Set Distant) including details of all track crossing/Horizontal boring/Cable Loop /Cable Joints etc. in Auto CAD & submission of coloured paper copies for approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Seven-Line Station.
Design of Cable Distribution Plan in Auto Set CAD & submission of Three paper copies for approval as per the practice of SCR. After approval, Auto CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy - for a Seven-Line Station.
Design of Track Bonding Plan in Auto Set CAD & submission of Three paper copies for approval. After approval, Auto CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet alongwith its scanned copy - for a Seven-Line Station.
Design of Location Box Drawings in Auto Each CAD (Including Contact Analysis, Fuse Particulars, cable particulars etc.) and submission of Three paper copies for approval in A4/A3 white papers. After approval, Auto CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies in Ammonia print of final approved drawing in plastic cover in properly bound booklet along with its scanned copy. (unit: per location box)
Alteration of Existing Circuit Diagrams Sheet consisting of the items as mentioned & submission of Three paper copies for approval; (i) Wiring Diagrams (ii) Relay Disposition Charts (iii) Contact Analysis and Fuse Particulars (iv) Panel Termination Chart (v) CT Rack Particulars (vi) Input & Output Bit Chart for El Systems.
Alteration of Existing Location Box Sheet Drawings (Including Contact Analysis, Fuse Particulars etc) and submission of Three paper copies for approval.
Supply of A3 size Ammonia Prints or Sheet Print as approved by Rly.
Supply of A2 size Ammonia Prints or Sheet Print as approved by Rly.
Scanning of A3 page Documents from Per Page the approved Tracing film. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fabrication & supply of different Boards - Station Preparation of Station Working Order Diagram (SWOD) on non- transparent acrylic sheet of thickness 4mm with aluminium beading and hanging support with screen printing, lettering and yard diagram (Inspection: Consignee). (uniT: PER YARD/PER STATION)
Fabrication & supply of different Boards - Station Preparation of Track Bonding Diagram on non-transparent acrylic sheet of thickness 4mm with aluminium beading and hanging support with screen printing, lettering and bonding diagram (Inspection: Consignee). (UNIT: PER YARD/PER STATION)
Fabrication & supply of different Boards - Each Manufacture and supply of laminated board of size 45cm x 60cm and 12mm thick with printed instructions as directed by engineer in-charge (Inspection: Consignee). (UNIT: PER BOARD)
Making photo copies & binding of the Each SWR literature in English/Hindi/Diglot form as per Rly practice. (UNIT: PER BOOKLET)
Removal of existing 'Q' style/K-50 Numbers contact clips along with its wire from the relay base by carefully tracing out from the bunch of wires and taking out unwanted wires from the same as per the alterations shown in the circuit diagram issued by Rlys. Drawing of fresh new wire from the relay base to another relay base as per the new wiring as shown in the circuit diagram without affecting the other wires. This also includes testing of wires using buzzer of the new wires drawn once before soldering, once after soldering (This includes of wires required for data l o g g e r s ) . (UNIT: PER CONDUCTOR= NUMBER)
Carrying out of alterations to the Sheet working circuits and fixing of relays and relay groups and energization of relays as per approved circuit diagrams. (All materials such as Rosin core, flux, nylon thread, eyelets and PVC dotted tape to be supplied by Contractor. Indoor cables, relays and relay groups, fuses, LEDs, Resistances will be supplied by Rlys. (unit: per sheet of circuit diagram)
Releasing of existing TLD boxes with Numbers stumps terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Rly representative at site.
Supply & fixing of 20 pair CT box and Each termination of jelly filled cable as per details given by engineer at site for LC gates/Pump house (Inspection: Consignee). (UNIT: PER LOCATION=EACH) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
"Supply & installation of Rack 19"" wall Numbers mount 6U/500MM D with front glass door and lock and key including the following: 1. 1 U Cable manager - 1 No. 2. 1 U Cantilever tray - 1 No. 3. AC distribution box 5X5 amps - 1 No. 4. Front panel H/W PKT of 10 Sets - 1 No. 5. Cooling fan of 230V AC operated The rack should be of APW President/Rittal make or better (Inspection: Consignee). Total 50177910.00
Item Breakup - C-Schedule-C
Supply of Hylam sheet, resinbonded, Numbers grade P3 as per IS Specn IS 2036 of 1974 or latest of size: 10mm thick, grade P3 and size 2400mm X 1200mm (Inspection: Consignee).
Supply of FMS (Fiber Monitoring Numbers S o f t w a r e / A p p l i c a t i o n software for monitoring optical fiber network) server application with Google Conduit; a) Basic Fault Management Module for detecting the fault in the optical fibre under surveillance and provide the optical distance and corresponding surface distance of the fault identified. b) Map Integration Module displaying fibre route in GIS/ Google map and display the visual indication of the faults on the map c) Network Analysis Module for analysis of the optical fibres under surveillance and provide trend analysis d) Report Generation Module for customizable report generation e) Modem Interface for SMS based alarm escalation for escalation of alarms through SMS to registered users as defined by admin f) Fibre Database Designer Module h) As Built Drawing/GIS Integrator Module i) Configuration. Module j) Fault restoration Updating Module for tracking of restoration and updating of the restored fibres k) Interface with customer NOC for Trouble Ticketing l) Integration with Field Mobile Application Module. m) Schematics Module n) Port to Port Connectivity module o) Service Provisioning module p) Integration with NMS for Active Link correlation (as per instructions of site incharge) (Inspection: RITES).
Suppiy of server hardware KAID/Online Numbers UPS - 1x Intel Xeon E5-4607 (2.2 GHZ/6 Core/12MB/95w) processor/ 8GB memory or higher/5SFF Drive or higher Cage/No GW ERWC Cantroller Raid/100M CS Platinum Hot Power Supply. Item should be equivalent or superior to the above Specn should support operating systems: Microsoft Windows S01 R2, or binher Support Iov4/Ipv6. Database: MS SQL standard edition with 5 CAL - Antivirus should be installed and regular updates/ signature and support shall be (aIThis item also include supplv of UPS of 2 KVA with 12 V, 100 AH (7 Nos.) Battery (Inspection: RITES). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Cable & Pipe Locator with Numbers integrated RTK-GNSS, having a minimum 10W, 200mA, 60V transmitter with rechargable battery facility (8 hours backup), suitable for underground cable/pipe locating, depth measurement, and GIS mapping. The equipment shall support active/passive detection, direct, clamp, and induction modes, with RTK positioning accuracy of 3-5 cm or better, GPS route logging, Bluetooth connectivity and GIS data export, including a 3-years subscription. The supply shall include one compatible Android smartphone (minimum 12 GB RAM, 256 GB storage, 6.7-inch display and 4700 mAh battery). Make: Telogica, Model: Techmagix (RTK) or better (Inspection: RITES).
Supply of 2 Wire 2Mbps G.SHDSL Pair modem consisting of one E1 unit and one V.35 units with built in power supply AC or DC from single socket which supports pluggable DTE interface card to accommodate G.703 E1, V.35, ETH, EL to V.35 converter, E1 to ETH converter. The unit tohave provision to interoperable with a ceter located rack with SHDSL modules (tec approved interfaces E1, V.35, E1 to V.35 and Ethernet) Model: WL/E1/2W/AC/DC, Make: mrotek/actel/gygnus or better (Inspection: Consignee).
Supply of Office table with plywood Set plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty 'S' type chair with hand rest. The above is of Godrej or similar make (Inspection: Consignee).
Supply of steel stools 18" height neatly Numbers finished and painted (Inspection: Consignee).
Supply of Fiber table of 4 Feet x 2 Feet Numbers one number and fiber chairs two numbers. They should be of standard make and quality like Neel kamal or similar (Inspection: Consignee).
Supply of 48 Core LIU, 19" Rack Numbers Mountable, with fully loaded SC/APC IO connector and Pigtails Make: R&M/ Systimax/Panduit or better (Inspection: Consignee).
Supply of aspiration type smoke Numbers detector. Highly sensitive smoke aspiration system for monitoring of rooms and equipment's for earliest possible fire detection For Relay rooms as per RDSO Specn No. RDSO/SPN/217/2018 Ver.2.0 or latest. (Inspection: RDSO)
Supply consisting of DC-DC converters: 24- 40V/10A- 8 Nos. and 24-32V/10A- 4 Nos. with SPDs installed and dummy slots wired. Statcon make as per RDSO spec RDSO/SPN/165/2012 Ver 3.0 or latest. (Inspection:RDSO)
Supply of Sleeper Clamps for holding Numbers cable for 52kg/ 60kg sizes as per instructions of Site Engineer (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY Total 9496150.65
Item Breakup - D-Schedule-D
Preparation of Cable route planfrom Kilometre raster data, by conducting Lidar equipped Drone with Ground Control Points implemented using DGPS. This includes mapping of S&T assets such as Underground Live cables (Including Track crossings Cables) upto 5 Trenches, Cable joints, Underground Cables, Signals, Point Machines, Axle Counters, LC Gates, Station, IBP, OHE Mast and Hecto metre posts. Measurement Procedures: i) The marking of assets should contain values such as Chainage in meters (as per Rly standards) ahead and behind Reference OHE Mast numbers/Hecto meters. ii) For Underground Cable position details: A) Track to cable andcable to boundary interdistance, B) Height difference values ref. MSL Datum, should be provided, C) The intervals between measured points from track in vertical should be at 5mtrs-1mtr as per requirement. Deliverables: from A) submission of map asa GIS project file, with associated Raster, Vector layers of Data as soft copy, B) Cable route plan in soft and hardcopies (upto 2 copies) as per Rly standards. Marking of allthe existing /newly laid Underground live cables with co-operation with other firms and department (Such as Electrical, Engineering, P.Way),route will be done by Contractor by foot with Rlys staff in field for navigating buried cables. The scope includes integration of Captured orthomap, Topographic data and CAD Drawing data into developed Web-GIS Application Ver.1.2 that Provided in SCR, as per instructions of site incharge.
Installation of Sleeper Clamps for Numbers holding cable for 52kg/ 60kg sizes as per instructions of Site Engineer. Note: Includes installation of clamps, drawing HDPE pipe and 2 core cables and connecting to Rail . (unit: per clamp)
Fencing for Location Box duly providing Set foundation (A pit of size 400mmx400mmx1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted) and fixing the frames/doors and E type lock to the fencing with the supplied material. The rail post/Angular is to be erected up right in the foundation. All the materials are to be arranged and used by the Contractor (Rail post/ angular/frames/E type locks will be supplied by the Rly). Cutting of rail post/angular to the required length, transportation to the site by the Contractor.
Supply & installation of Managed POE, Numbers 24 port Gigbit Ethernet Switch CBS 350- 24P power budget 195W (Inspection: Consignee). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply & fixing of 9U Rack with locking Numbers front glass door and fully vented rear steel door, compatible with standard 19" accessories, top cover with gland plate and fan, with rack cagenuts and screws, fan assembly kit, rack mount shelves, Power Manager, etc., this includes wiring as per the instruction of site incharge. Make: HCL/Vero president/bestnet or better (Inspection: Consignee).
Supply & installation of Air sampling Numbers CPVC Pipes with all required accessories for Aspiration system (Inspection: Consignee).
Supervision, programming, installation, Metre testing & commissioning of Aspiration smoke detection supplied.
Supply & installation of Surge Protection Numbers Device of class 'D' Type for 12V DC supply between power equipment and signaling system complete with MS enclosure and connection wires/cables as per Tech Specn the Model No. SDL- HFF-16 or similar as per the Specn enclosed as per the Specn RDSO/SPN/TC/98/2011 or latest (Inspection: RDSO).
Lime wash on walls/foundations at site Sqm and directed by site incharge one coat with quick lime of approved quality.
Numbering of location box as per Numbers standard practice and writing all Cable (main and tail) termination particulars and equipments inside the location box as per the details. LB serial number on four sides of the box, connected earth pit particulars and implantation to the track.
Preparation of Station Working Rules, Each CRS papers etc as practice in Rlys for yards/LC Gate IBH including xerox. (unit:per application)
Glass type fuse (FST 400 mA, 5*20 mm) Numbers (0034.3113.G) (Inspection: Consignee)
Labour assistance for SE/JE in day to day Man-Days works i.e checking the curves/straight alignment of formation, levels etc. Carrying the tools & equipment etc. watch & ward during the course of execution or work as perr the instructions of concerned SE/JE (as per Chief labour commissioner File No. 1/16 (6)/2022-LS II (Dt.03.04.2023) (unit: mandays)
Supply & installation of Ultrasonice High Numbers Variable Frequency Rat Repellant Make: Varna or better (Inspection: Consignee).
Supply of Designing and UV Printing of Square Foot station working order/Track bonding diagrams of size 6ft x 3ft in moldedaluminum channel with elegant and stainless steel star brackets for hanging arrangement. Printing in UV print and designing in corel draw package.
Painting of S&T gadgets. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply & transportation of RCC Duct Numbers (Trunking and Capping) with 290mm width, 260mm height and 700mm Length as per Drg No. 5778A (Inspection: RITES).
Supply & installation of Highspeed Numbers providing 1/100 Mbps Fast Eathernet port, RJ45 connector suitable to accommodate in Mapple 4 slots Make: MROTEK/Puncum or better (Inspection: Consignee).
Supply & installation of Audio interface Numbers card for user providing ten FXS links per card suitable to be accommodated in PCM multi service integrated access TDM PCM multiplexer suitable for Maple 4C. Make: MROTEK/ Cygnus or better (Inspection: Consignee).
Supply & installation of Audio interface Numbers card for user providing ten FXO links per card suitable to be accommodated in PCM multiservice integrated access TDM PCM multiplexer (Inspection: Consignee).
Supply & installation of 2W/4W E&M Numbers interface module with eight interfaces suitable for Maple 4C. Make: MROTEK /Cygnus or better (Inspection: Consignee).
Supply & installation of multiservice Numbers (chassis 1 U) Integrated access TDM Multiplexer with 4E1 interface up link (120 Ohms balanced RJ 45 connectors) with 3 Module slots with AC/DC power supply model MAPLE - 4C Make: MROTEK or better (Inspection: Consignee). Total 5841689.57
Item Breakup - E-Schedule-E
Supply of QUINT Inverter DIN rail Numbers mounting, Input 24 V DC/110V DC and Output 230V AC/120V AC,600VA pure sine with max. current consumption of 28A and output voltage 120V AC, (Plus minus) 2%, (100V AC/ 6A-130V AC/4.6 A)/230V AC (Plus minus) 2% (200V AC /3A-240 V/2.5A).Manual selection of AC output voltage via signal terminal form of output voltage pure sine. Real power 480W, MTBF (IEC-61709)-532525h (40 0C). Screw connection conductor size 0.2 mm2-4 mm2, with signal output. Ambient temperature (operation)- -25 0C - 60 0C, Max permissible relative humidity (operation)-%u2264 95% stock-20g in all directions (EN 60068-2- 27), vibration (operation)-5 HZ-100HZ, 0.7g (EN 60068-2-6), Noise immunity in accordance with EN 61000-6-2 or latest. Make Phoenix Contact As per Corrigendum of Technical Advisory Note no. STS/E/TAN/3012 Ver.3.0, Date 03/11/2022 at SM Room with redundant feature (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Remote Terminal Unit having Numbers 64 integrated inbuilt optical ports (LC type) for monitoring the dark fibre and capable of covering a monitoring distance of minimum 75 Km from each optical port. Equipment must be of 42 dB or higher dynamic range. RTU shall have power supply unit operating in DC (-72V DC to -36V DC). RTU with 64 inbuilt ports must be able to be fitted in 19" Rack and Maximum 1U Space. It should able to generate wavelength of 1650 nm for monitoring of fibres. RTU shall support operation in temperature range of -40 to 65 degree centigrade. (TEC Std No. TEC 88150:2015 with amendment No. 1 Dated: 22.01.2025) Similar to Model No. ALM-64 port of Adtran make or better. (Inspection:RITES)
Supply of Portable Insulation Monitor Numbers with fault locator kit with fault locator kit for Rly including following; i) iso685-D-P Insulation Monitoring Device (IMD) with integrated locating current injector. ii) EDS 195PM Insulation fault locator. iii) PSA3052 Measuring clamp 52mm. iv) PSA3352 Measuring clamp 52mm. v) EDS195PM Accessories for 1 No. of USB power supply unit. Primary: 100....240 V, 50....60 Hz Secondary DC 5V, +/- 10% Power consumption < 0.5W. vi) iso685- D-P Accessories for 3 Nos. of safety measuring cable black along with clamps and 2 Nos. Safety measuring cable Green/Yellow along with clamps for system connection and 1 No. Auxillary supply cable. Make: Bender or better. (Inspection: RITES) Total 10998908.36
Item Breakup - F-Schedule-F
Supply & installation of MAPLE 4CS with Numbers Fiber, E18 E&M Supply of Multiplexer for DAC/UFSBI to optical, STM/IP-MPLS(E1). Standard 19" Rack Mountable device consisting of four E1 interface, dual optical ports with dual core or Single core path 20 Kms driving distance. ultidirection supporting upto 5 direction either with optical or E1. Ethernet ports for camera connectivity. RS232 interface for RTU connectivity. EM cards with 8* E&M ports with 2W/4W setting. FXO/FXS card support with 10* FXO/FXS ports. Total 4 hot swappable slots for field upgradable Multi service Modular cards. Device Management with Telent& NMS. Unit Support Audio Buzzer Alarm Interface. Potential Free contact. Dual DC with 18-72VDC range. Accessories - AC-DC adaptor, E1 & E&M cable. Power Protection support -DC+DC, DC+AC. Accessories - NMS, AC-DC adaptor, E1& E&M cable. Environment tested as per IEC 60068-2-1 & IEC 60068-2-2 Make: MROTEK or better. (Inspection: RITES) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply & installation of OFC joint Numbers enclosure as per RDSO Specification No. RDSO/SPN/TC/68/2025 (Revision 2.0)and splicing of Optic fibre cable (48 fibres). (Inspection: Consignee)
Supply, installation & commissioning Numbers (SIC) of a high-fidelity, Passenger Address System, featuring proprietary driving software with NTES integration and auto updation of train information with dedicated media and user manuals for each unit. The hardware solution mandates an enterprise-grade workstation equipped with an Intel Core i5 processor, 8GB DDR5 RAM, 512GB nvme M.2 storage, and a preloaded/licensed Windows 11/higher OS, complemented by a 21.5" LED- backlit monitor and full I/O audio suite with all installations subject to final site- specific inspection and certification by the designated Consignee and Rly officials..(Inspection: Consignee) (Unit: per goomty/IBH/Auto hut
Collection, Inward &Inventorization of Each Documents, Preprocessing of documents before Scanning and Handover back physical documents to the Department. (unit: per image)
Scanning of A3 Size and A4 Size. (Unit: Each per image)
Scanning of A2, A1 & A0 Size Pages Each maximum upto 350 mm X 5 meters (unit: per image)
Classification of document images, Each Metadata capturing & Indexing. (unit: per image)
Quality Check post Scanning & Metadata Each Capture and upload Digital documents in to DMS. (unit: per image)
Supply of Iron Mountain DMS application Numbers and configuration as per User requirement. Total 2804769.40
Item Breakup - G-Schedule-G
Supply, design, installation, testing & Each commissioning of Multi Section Digital Axle Counter (MSDAC) Complete System as per RDSO Specn No. RDSO/SPN/176/2013 Ver.3 with latest Amdts STR No. SIQ001 Ver.2.0 Unified PL No. 56040246 or latest. Suitable for commissioning of Yard replacement. Tender shall designthe scheme for provision of required number of evaluators, Track side junction boxes, detection points and Track clearance Relays etc. to be submitted along with the offer, MSDAC should have facility toreset Track Sections. System shall be with cooperate type design and the total cost break up shall begiven against the indent. Design of Axle Counter Circuit indoor installation, testing and commissioning of MSDAC (Per Unit), supply of essential 10% spares covering alltypes of cards, wheel sensors for MSDAC detailed cost and quantity wise break up of all spares should be given (Per Set). Supply of Diagnostic System for Remote Diagnostic (Per 1 No.) Tool set for wheel sensor mounting and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver and gloves and multimeter Fluke 115 (1 No.) Make: Frauscher or better (Inspection: RDSO). Note: As per the General Technical Conditions and Drawing given in Annexure. (unit: Each=per DP)
Supply of Tool Kit for installation and Numbers Maintenance of MSDAC as per OEM requirement. It shall include the exhausive list of tools used for the installation of Indoor and Outdoor Equipment (Inspection: Consignee).
"Supply & installation of Diagnostic Station syste m : 1) It should consist of the diagnostic terminal with minimum 32 inches LED monitor for fault diagnosis. 2) It shall contain fan less embedded Industrial grade computer (similar to Moxa V2406 or better). 3) Connectivity to the MSDAC shall be either on Ethernet or through Optical Fiber Cable. However, Optical Fiber Cable is preferred medium. 4) Suitable arrangements shall be made to fix the terminal in the Station/Goomty as per the instructions of Engineer in charge. 5) Rly will provide single phase 230V AC/110V DC only (Inspection: Consignee)." Total 28094303.30
Item Breakup - H-Schedule-H
Supply & installation of (Kavach) TCAS Set with necessary indoor wiring accessories. Designing of Interface, RFID Tag Layouts, RFID Tag Data, TOC, FAT and SAT. Interfacing of NMS with the existing Network to the Divisional office. (Inspection: RDSO)
Supply and installation of RFID Tags. Set (Inspection: RDSO) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Trenching from Relay Room to Tower Metre including supply of HDPE Pipe, DWC Pipe, GI Pipes and required track crossing if any. (Considered 1000 Mtrs for each station). (Inspection: Consignee)
Supply of 2X25 Sqmm Cable and 24 OFC Metre Cable for drawing cables from Relay Room to Tower and Relay Room to OFC Cabin.
Supply of Q-Series Kavach Repeater Numbers Relays.(Inspection: RDSO)
Modification to the existing RFID Tag Job Layout, TOCs and Tag Data for adjacent Stations. Total 10718147.52
Item Breakup - I-Schedule-I
Supply of Hot Standby Electronic Set Interlocking System (Centralised/Distributed) excluding Panel Processor (Hot Standby) with Signalling functions up to 125 functions as per function table enclosed along with 5% spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. used, tools, manuals and Instruments as per RDSO Specn RDSO/SPN/192/ 2019 ver. 2.0 or RDSO/SPN/203/2011 ver. 1.0 or latest. Note: Payment will be made for only vital bit as per function table attached by Rlys, no payment will be made for non Vital bits such as Counter bits, SM key Bits, Read back bits and any potential free contact bits of DC-DC converter or Modem of EI (Inspection: RDSO).
Incremental rate for vital signalling Each functions in EI System over and above 125 functions under item No 4101 along with spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. to the extent of 5% (Inspection: RDSO).(Unit: per function)
Supply Interlocking miscellaneous items with all IBH/LC/STN/Auto necessary accessories for End Location section (Goomty) for Station/IBH/Auto Hut for Distributed Architecture in connection with Item No. 1 & 2 of SCH-I. (Inspection: RDSO)
Supply of commercial grade operator Numbers VDU of size 55" Full HD, with backlit LED, with HDMI/DVI port, Inbuilt Speaker, required HDMI/DVI cables for connectivity and other miscellaneous item required for installation (Inspection: RDSO).
Supply of fan less embedded industrial Numbers grade computers (Similar to Moxa V2406A or better) with all accessories such as key board, mouse, antivirus etc. of industrial grade as per approved Specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest) (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation, wiring, testing, soldering of El all EI equipments, earthing of EI Equipment, Relay Racks and Power Equipment etc. including supply of power cable and Documents/Manuals (six set) etc. for EI.
Design and Drawing of Interface and El Application Logic for complete indoor signalling work for new EI station up to 200 Routes as per TOC. Initially, Contractor shall submit 1 copy for approval of Rlys. Final copy shall be submitted after incorporating correction if any.
Commissioning of Electronic Interlocking Numbers system.
Training of Rly Personnel in installation, Man-Days commissioning, testing, trouble shooting and in diagnosing faults using diagnostic tools/flow charts including supply of necessary documents
Training on application software for Man-Days designing, change in the logics and converting it suitable for system and loading the programme into the working system for alteration of SIP/TOC. The training should be comprehensive with complete document.
Supply of portable work station to run Numbers along with EI configuration tool, Data Inputs, Simulation, Functional testing, diagnostic and trouble shooting. (Inspection: RDSO)
Fabrication, transportation & fixing of RMT aluminium ladder at site made of Aluminium angle of size 38mmx5mm width 280mm, Flat size 25mmx5mm with powder coated colour as desired by engineer in charge at site and fixing, Drilling of suitable holes for fixing of Hylam sheet 3mm thickness on ladder and 2 Nos. of PVC trough 100mm with cover fixed on Hylam sheet along the ladder with all fixtures necessary ancillary materials required for fixing to be supplied and as directed by engineer in charge at site. (Inspection: RITES)
Supply, fabrication, installation and Numbers fixing of panel operator consol with arrangement to fix 55" VDU's -Reset boxes, and other S&T gadgets. This shall be made of not less than 18mm thick plywood or better materials with storage facility of approved colours with Contractors' materials, lead, lift and manpower as per the instructions of the Engineer-in-Charge and as per the enclosed drawing (Inspection: Consignee).
Supply & installation of offline UPS Numbers 1000VA, 30 min backup as per instructions of Engineer in charge. (Inspection: Consignee) Total 27011573.00
Item Breakup - J-Schedule-J
Modification to the existing EI System at Set Station as per RDSO Specn No. RDSO/SPN/192/2019 or latest, in connection with the Yard modification, as per Specn given in Annexure-XVII (Inspection: RDSO)
Modification/alterations Electronic Interlocking System of Centralized/Distributed Architecture & associated works. as per Specn given in Annexure-XVII (Inspection: RDSO) Total 7994627.00
Item Breakup - K-Schedule-K
Alteration/modification of Station TCAS Lumpsum at Station as per Specn No. RDSO/SPN/196/2012 Ver.3.2 or latest and as per Specn given in Annexure-XVII (Inspection: RDSO). Total 3135684.80
Item Breakup - L-Schedule-L
Supply of Flexible PVC insulated 3-core x Metre 6 Sq.mm multi strand armoured power cables provided for each of the display boards shall conform to specification no.IS: 694:1990 reaffirmed 1995 or latest. Make: Finolex or any IS brand. (Inspection by Consignee).
Supply of STP (Shielded Twisted Pair) Boxes pure copper CAT-6A Cable shall be compliant with latest EIA/TIA-568-B.2-1 standard for MOLEX/NOTOFIRE/FINOLEX/D- LINK/TRICOM or latest each drum/Box of 305 mtrs. (Inspection: RITES).
Supply of single channel triple speed Numbers standalone Giga bit media convertor 10/100/1000 on single mode fiber with all accessories and connecting cables. Make: MROTEK/ HOSTA- UG/DAX/HCL/TeamEngineers/DAX/Netfox or latest (Inspection by Consignee).
Supply of 2M HDMI 2.0 Cable M/M Numbers 30AWG Gold Black /Crestron/Aten/NT CBL-8K-HD-9 or better (Inspection by Consignee).
Supply of Central Data Controller Numbers consisting of with other accessories as per RDSO/SPN/TC/108/2019 (Ver.2.0) A m e n d t . 1 or latest. Announcement recordings in digital format as per details given by Rlys. Software for announcement system, various types of display boards information management & LED/LCD PIS management. Note- This includes CCU Rack with 2 Industrial PCs, Software, CDS, UPS with minimum one hour backup, KVM Switch and all necessory connecting cables etc. (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of 1x4 HDMI splitter model No. Numbers VS481B Make Atten/Kramer/Extron/Crestron HD-DA4- 4KZ-E or better (Inspection by Consignee).
Supply of Multi Cord Binders SIZE 16 Numbers mm Make: MX or better (1.5 mts length) Make: MX or better (Inspection by Consignee).
Supply of Multi Cord Binders SIZE 22 Numbers mm Make: MX or better (1.5 mts length) Make: MX or better (Inspection by Consignee).
Supply of Coach Guidance Display Numbers boards as per RDSO/SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest. (Inspection: RDSO).
Supply of At A Glance Display Board Numbers (32x192) Single sided as per RDSO/SPN/TC/108/2019 (Ver.2.0) A m e n d t . 1 or latest (Inspection by RDSO).
Supply of Single Line Double Faced Numbers Platform Display Board as per RDSO/SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest (Inspection: RDSO).
Supply and installation of UPS 10 KVA Numbers with 6 hour back up along with all accessories including battery rack and connecting cables. Any other items required for installation at site should be arranged by the Contractor with SNMP card. Battery: 12V/200AH minimum capacity. 20 Number of SMF batteries. Microprocessor controlled High input power factor > 0.95. Pure sine wave True double conversion technology. Self diagnostics Large LCD monitor 32 character with UPS operating status. High compatibility with generators. Smart over load & short circuit protection for utility/invertor mode. Integelegent battery monitoring. Make: APC/NUMERIC /EMERSION or better (Inspection: RITES).
Supply of Central Data Switch complete Numbers with all accessories as per RDSO/SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest (Inspection: RDSO).
Supply of 16 port Platform Data Numbers controller as per RDSO Specn No. RDSO/SPN/TC/108/2019. Ver.2.0. Amendt.1 or latest (Inspection by RDSO).
Supply of 12 fibre mono mode armoured Metre optical fiber cable - fibre to have nominal dia. of 8.8 m to 9.8 m and normal cladding diameter of 125 m ± 1 or better. As per RDSO Spec No.IRS: TC 55 2006(Rev.1.0) Amdt.3 or latest Make: Finolex or better.(Inspection: Consignee)
Supply of SC to LC armoured Patch cords Numbers (3 mts length) with 0dB adaptors as per TECspec G/OJC-01/03 Jan 99 or latest. Make:MX/D- Link/Bestnet/legrand/Systimax or better. (Inspection: Consignee) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of SC-SC to SC-SC armoured Numbers patch cords (3 mts length) with 0dB adaptors as per TEC spec G/OJC-01/03 Jan 99 or latest. Make: MX/D- Link/Bestnet/legrand/Systimax or better. (Inspection: Consignee)
Supply of Cat-6 Patch Chord, 1m. Make: Numbers D-link/Bestnet/ Comscope/Molex/Amp or better.(Inspection: Consignee)
Supply of Cat-6 Patch Chord, 2m. Make: Numbers D-link/Bestnet/ Comscope/ Molex/Amp or better.(Inspection: Consignee)
Supply of Cat-6 Patch Chord, 5 feet. Numbers Make: D-link/ Bestnet/Comscope/Molex/Amp or better. (Inspection: Consignee)
Supply of GI pipes of 65mm dia Medium RMT quality to Specn No. IS.1239 (Part-I) 1990& galvanized to Specn IS.4736- 1986 0rlatest and laying/fixing overcement/girder bridges/culvert/FOB/COP/walls, platform etc. lamping arrangement with MS brackets for fixing of GI pipes on bridges/culverts, small holes of 5mm areto be drilled on the pipe before laying ofthe pipes. All required materials are to be arranged by the Contractor. (Inspection: Consignee)
Supply of V600:4 - 4 Channel amplifier - Numbers 150W x 4 = 600W @ 100V (given for 16 pairs for speakers)(Inspection: Consignee)
Supply of Flexible PVC insulated 3-core x RMT 2.5 Sq.mm multi strand power cables provided for each of the display boards shall conform to specification no. IS: 694:1990 reaffirmed 1995 or latest. Make: Finolex or any IS brand. (Inspection: RITES).
Supply of Fiber table of 4 Feet x 2 Feet Set one number and fiber chairs two numbers. They should be of standard make and quality like Neel kamal or better.(Inspection: Consignee)
Supply of Multi Line (5 line) Single face Numbers Train Arrival/ Departure Display Boards as per RDSO Specn No. RDSO /SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest.(Inspection: RDSO)
Supply of Double faced with Red LED Numbers digital clock suitable for platform area asper RDSO Spec No. RDSO SPN TC 62 2008 Rev.3.0 latest (Inspection by RDSO).
Supply of 25W VHF set Make: Motorola/ Numbers XirM6660 with 3 years licence or better. (Inspection: RDSO)
Supply of feeder cable (30mtrs) of Numbers reputed make.(Inspection: Consignee)
Supply of GP antenna 3db Make: Kenstel Numbers or better.(Inspection: Consignee)
Supply of 12V-100AH MF battery Make: Numbers Exide/ Amarraja/HBL or better. (Inspection: Consignee)
Supply of 230V AC/12V DC , 15Amp Numbers SMPS charger of reputed make. (Inspection: Consignee) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Double faced At A Glance Numbers Display Board in single line as per RDSO/SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest (Inspection: RDSO). Total 16374004.47
Item Breakup - M-Schedule-M
Supply & installation of Junction box with Set required MCB as per thesite requirement Make: Lagrand or latest.(Inspection: Consignee)
Supply & installation of rack mounted Numbers 12F FMS fiber part no.fms-1u 12FS 12FP Raychem/Bestnet/Rosen berger make including 12 Nos 0.2db SC/PC adaptors and 12 numbers 900 micron 1.5 meter SCPC pigtails and as specified by supervisor in-charge.(Inspection: Consignee)
Cutting of trench across the platform RMT with cutting machine, laying the cable through PVC/GI pipe and filling the trench after cable laying and restoring the surface with plaster etc. or as per requirement and instructions of site incharge (PVC/GI pipe and cable will be supplied by Rlys)
Supply & fixing/laying of 25mm dia 2mm Metre thick PVC pipe (Sudhakar/SR/Nandi or better) on the walls. All the required accessories such as GI clamps, Deep boxes, Jn Boxes, Normal bends, diversion bends etc are to be arranged by the Contractor, as specified by supervisor in- charge. (Inspection: Consignee)
Supply & fixing/laying of 50mm dia 2mm Metre thick PVC pipe (Sudhakar/SR/Nandi or better make) on the walls. All the required accessories such as GI clamps, Deep boxes, Jn Boxes, Normal bends, diversion bends etc are to be arranged by the Contractor, as specified by supervisor in-charge.(Inspection: Consignee)
Supply & fixing of PVC Flexible pipe RMT (reputed make) of different sizes 25/40/50/60mm dia as per site requirement (Industrial grade). (Inspection: Consignee)
Supply & fixing of 8 way RJ-45 Jack RMT suitable for computer fixed on the modular PVC top covers including termination of cable pairs.(Inspection: Consignee)
Laying of 5 pair screened sheathed/CAT RMT 6/power cable through PVC Pipe/tray as per instruction of site incharge.
Laying of OFC cable on tray as per RMT instruction of site incharge.
Supply & installation of 4 way Spike Numbers busters with 5 mtrs power cable with individual switch and Fused for each socket 16/5A. Make: NAX/Gold medal/ Anchor or better as specified by supervisor in-charge.(Inspection: Consignee) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation, commissioning of Double Numbers Faced Coach Guidance Display Boards in covered area as per the standard procedure and the instructions of site Supervisor. All materials required for installation & commissioning are to be arranged by Contractor. This item also includes supply, installation and commissioning of necessary hardware equipment Junction box etc. for executing.
Installation & commissioning of Double Numbers Faced Coach Guidance Display Boards and integration of CIBs in open area as per the standard proceure and instructions of site Supervisor. All materials required for installation & commissioning to be arranged by Contractor. This item also includes supply, installation and commissioning of necessary hardware equipment Junction box etc. for executing.
Supply & installation of Class D/C type Set Lightning Cum surge protection safety device with Visual indication, pluggable and testable with surge tester and potential free contacts. Outputs suitable for 48V DC applications (Conforming to RDSO Specn No. RDSO/ SPN/165/2012 or latest and should be tested as per IEC 61643) it also includes supply and installation of Surge Protection devices duly wired mounted on din rail with necessary fittings like Nuts and bolts etc. as per the site requirements and the Engineer in charge.(Inspection: RDSO)
Installation, integration & commissioning Numbers of At A Glance Display Board: (32x192) Single sided with IPIS of RDSO/ SPN/TC/108/2019 (Ver.2). All materials required for fixing and installation should be supplied by Contractor.
Installation & commissioning of Single Numbers Line Double Faced Display Boards Platforms. All materials required for installation & commissioning to be arranged by Contractor
Installation of 16 port Platform Data Numbers controller in suitable capacity 9U rack with 8-16 port LIU and rack mountable power sockets and as per instructions of suite incharge. (All required materials for installation are to be arranged by the Contractor).
Installation & commissioning of Central Numbers Data Controller (CDC) and RMS server under supply portion
Installation & commissioning of Central Numbers Data Switch (CDS) vide supply portion
Installation of Multi Line (5 line) Single Numbers face Train Arrival/Departure Display Boards as per RDSO Specn No. RDSO/SPN/TC/108/2019 (Ver.2.0) Amendt.1 or latest as per instructions of site incharge (All required materials are to be arranged by Contractor).
Supply & installation of offline UPS Numbers 1000VA, 30 min backup as per instructions of Engineer in charge. (Inspection: Consignee) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation of Double faced with Red Numbers LED digital clock suitable for platform area as per RDSO Specn No. RDSO/ SPN/TC@ 47>47@/2008 Rev.3.0 as per instructions of site incharge (All required materials are to be arranged by Contractor).
Supply & installation of UPS 6 KVA with 4 Numbers hours back up along with all accessories including battery rack and connecting cables. Any other items required for installation at site should be arranged by the Contractor. Battery: 12V/120AH minimum capacity. 20 Nos. of SMF batteries. Microprocessor controlled High input power factor > 0.95. Pure sine wave True double conversion technology. Self diagnostics Large LCD monitor 32 character with UPS operating status. High compatibility with generators. Smart over load & shor circuit protection for utility/invertor mode. Integelegent battery monitoring. Make: APC/NUMERIC/EMERSION or better reputed make (Inspection: RITES).
Breaking of metal/tar road and refilling RMT after laying the cables as per Drg No. SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
Track Horizontal Boring method at culverts/track/pucca road as per SCR Drg No. 5770. This also includes insertion of HDPE pipe of 110mm /GI Pipe of 100mm in the bore drilled (HDPE pipe/GI pipe is to be supplied by Rly).
Excavation of jointing pit and provision Numbers of RCC/FRP joint /Loop chambers of 90 Cms. Inner dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom cover with hole for drainage and cable entry as per Drg No. RAILTEL/SR/OFC/2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc. The chamber shall be filled with sand mixed with anti-stermic power, back filling and ramming of trench after HDPE duct laying, splicing and commissioning. Total 6671041.96
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-15.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
GCCCorrectionSlipNo.11.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
MakeinindiaPolicy1.pdf
ATTACHMENT
BankGuaranteee-
ATTACHMENT
Experience.pdf
ATTACHMENT
Acceptanceofe-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].