14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where:- V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
(a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
SIMILAR NATURE OF WORK: For satisfying eligibility criteria for the subject tender, similar nature of work means "Any Railway Signaling work of EI OR PI OR RRI in Passenger carrying System." The successful bidder shall submit an undertaking from RDSO approved El OEM, before the supply of material, to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.
34 conditions · 12 needing a document upload
Undertaking that the item will be procured from RDSO Approved firm.
Statement of Deviation
Power of Attorney
Certificate to be submitted / uploaded by tenderer along with the tender documents (Annexure V), Part I of GCC.
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
EMD Submitted
List of personnel, organization available on hand and proposed to be engaged for the subject work.
List of plant & machinery available on hand (own) and proposed to be inducted (own and hired to be given separately) for the subject work.
List of works completed in the last three financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given
List of works on hand indicating description of work, contract value, approximate value of balance work yet to be done and date of award.
Copy of PAN card
Documents for Turnover for financial eligibility criteria
Documents for technical eligibility criteria - Performance certificates for single similar nature of work
NEFT Details
GST Registration Certificate Copy
Bid Security Declaration in lieu of EMD Submitted
Organization details
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where: - V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Client certificate from other than Govt Organization should be duly supported by Form 16A/26AS generated through TRACES of Income Tax Department of India.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Power of Attorney
Annexure-V(A), Part I of GCC (This certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV)/Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.)
(Bid Security) Bank Guarantee Bond from any scheduled commercial bank of India (Annexure VI(A)
NEFT Details
Copy of PAN card
Organization details
GST REGISTRATION/ A CERTIFCATE FOR NON-APPLICABILITY OF GST REGISTRATION
Signal and Telecommunication Work in connection with Development of Ballast depot for increasing the ballast capacity at Doravari Chatram (DVR) in Chennai Division.
M-SG-2026-494-DVR_BD~SR
M-SG-2026-494-DVR_BD
Open
Works - General
6 Months
Chennai, Tamil Nadu
₹0
₹2.4 L
6 Feb 2026
14 Jan 2026
23 Jan 2026
115 items across 1 schedule · ₹1,11,97,552.07 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply a n d Provision o f Earthing a s per R DSO Specification RDSO/SPN/197/2008 or l a t e s t ( a s p e r Te c h n i c a l Specification enclosed) | Numbers | 2.00 | 28,118.51 | 56,237.02 |
| 2 | Supply of earth electrodes (GI) as per Drg no SG/CN/02/13 | Numbers | 18.00 | 1,618.75 | 29,137.5 |
| 3 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 18.00 | 1,707.55 | 30,735.9 |
| 4 | Supply of Stackable type VRLA batteries 2V, 200Ah - 1 cell as per RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 180.00 | 4,074.88 | 7,33,478.4 |
| 5 | Supply o f Low maintenance secondary cells o f t h e following capacities w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply o f Secondary cells - 2V- 80AH capacity | Numbers | 48.00 | 3,379.2 | 1,62,201.6 |
| 6 | Supply of track feed battery charger IRS:S 89-2013 | Numbers | 15.00 | 4,375.25 | 65,628.75 |
| 7 | Supply of 'B type choke IRS:S 65-83 | Numbers | 30.00 | 2,855.6 | 85,668 |
| 8 | S u p p l y , i n s t a l l a t i o n a n d w i r i n g of Transformer rectifier 110VAC/24V D C - 2A capacity a t Power r o o m / apparatus cases and connecting i t t o t h e relevant circuit as per approved circuit diagram using wire PVC 3/0.75mm copper and painting of particulars as per Railway practice. (As per IRS Spec. No. IRS:S 91-2014).[Transformer rectifier 110V AC/24VDC - 2A capacity, wire PVC 3/0.75mm copper and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 2.00 | 9,557.1 | 19,114.2 |
| 9 | Supply of 24 Core x 1.5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S- 63/2014 REV.4 | Metre | 5000.00 | 388.15 | 19,40,750 |
| 10 | S u p p l y o f 1 2 Cx1 .5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 5000.00 | 215.92 | 10,79,600 |
| 11 | " S u p p l y o f 2 x 2 . 5 s q . m m P V C insulated Armoured, unscreened, underground Railway Signalling Copper cable as per spec IRS.S.63/2014(Rev.4.0) or latest" | Metre | 3000.00 | 98.76 | 2,96,280 |
| 12 | Supply o f Underground jelly filled 6 QUAD, 0.9MM D i a a s p e r spe c IRS:TC 30-05 with amd 5 or latest | Metre | 2000.00 | 301.05 | 6,02,100 |
| 13 | Supply o f 4 8 Fibre armoured O F C cable as p e r R D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest | Metre | 3000.00 | 126.32 | 3,78,960 |
| 14 | Supply a n d provision o f normal joint using Thermo shrink jointing k i t (RDSO specs No TC/7 7 /2 0 1 2 ( R e v . 3 ) w i t h amendment N o . 1 & 2 o r l a t e s t . & j o i n t i n g k i t t o be inspected b y R D S O ) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f j o i n t p i t o f s i z e 1mX1.5mX1.5m and closing t h e same after completion o f cable j o i n t a s p e r t h e instruction o f Railway representative at site. | Numbers | 4.00 | 4,628.91 | 18,515.64 |
| 15 | S u p p l y a n d installation o f 4 8 fi b r e Joint enclosure f o r armoured optical fi b r e cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 4.00 | 20,060 | 80,240 |
| 16 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" a s p e r t h e i n s t r u c t i o n s o f Railway representative a t s i t e . ) as per drawing enclosed | Numbers | 115.00 | 262.65 | 30,204.75 |
| 17 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included i n this schedule) | Metre | 2750.00 | 64.1 | 1,76,275 |
| 18 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying o f cables i s n o t included i n this schedule.) | Metre | 400.00 | 32.05 | 12,820 |
| 19 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth o f 0 . 6 m t o accommodate t h e additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r the instructions of Railway Representatives at site. (Laying of cables is not included in this schedule). | Metre | 100.00 | 314.41 | 31,441 |
| 20 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating i t a s per the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation o f trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. T h e depth o f 1 m trench shall be from the bottom of sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 60.00 | 385.45 | 23,127 |
| 21 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f D W C / R C C p i p e s with couplers/collars is not included in this schedule). | Metre | 60.00 | 501.03 | 30,061.8 |
| 22 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 60.00 | 208.54 | 12,512.4 |
| 23 | Provision o f G I p i p e s (50/100mm d i a ) for cable laying in hard rocky area with off sets a t b o t h e n d s d u l y supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes s h a l l b e c l o s e d w i t h b r i c k masonry abutments work so that no cable is exposed, T h e w ork shall be carried o u t a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Metre | 140.00 | 182.87 | 25,601.8 |
| 24 | L a y i n g o f signaling/power/ telecommunication cables a s per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule). | Metre 15000.00 | — | 18.18 | 2,72,700 |
| 25 | Placing of one row of country bricks of size approximately 220mm x 100mm x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 2750.00 | 62.99 | 1,73,222.5 |
| 26 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating t h e t r e n c h by ramming and levelling." | Metre | 2750.00 | 15.4 | 42,350 |
| 27 | "Digging of pit to a depth of 800mm of size 3 0 0 m m X 3 0 0 m m , c a s t i n g o f concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d refilling t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at an interval of 20 M t r s . w i t h i n statio n l i m i t s a n d 5 0 Mtrs. outside station limits throughout t h e cable r o u t e , d i v e r s i o n s a n d a l s o a t every track/road crossing." | Numbers | 115.00 | 123.35 | 14,185.25 |
| 28 | Excavation o f c a b l e c o i l p i t t o a s i z e of 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n rea r o f relay rooms/ A F TC huts, apparatus c a s e s e t c . T h e w o r k includes coiling the underground cables a n d placing closely o n e layer o f country bricks o f size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 1.00 | 949.05 | 949.05 |
| 29 | " Ro a d crossing/ Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: T h e pilot used for HDD should be of sufficient size to s u i t insertion o f H D P E / D W C p i p e o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 4 0 m m d i a HDP E pipe o r a n y other combination a s d i r e c t e d b y t h e site engineer) ( S u p p l y o f H D P E p i p e i s not covered in this schedule)" | Metre | 280.00 | 1,351.45 | 3,78,406 |
| 30 | B lo w in g /D ra w in g o f O F C cable/Power cable/Signalling c a b l e i n s i d e permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid lubricated HDPE pipe. ( This includes Transportation o f materials from nominated stores to site) | Metre | 1000.00 | 23.43 | 23,430 |
| 31 | Supply of Main LED Signal Aspect - Green as p e r R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 8.00 | 10,030 | 80,240 |
| 32 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 16.00 | 8,850 | 1,41,600 |
| 33 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 8.00 | 9,233.5 | 73,868 |
| 34 | Supply o f subsidiary Signal Aspect - Route L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 20.00 | 5,703.33 | 1,14,066.6 |
| 35 | Supply of subsidiary Signal Aspect - Calling o n L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 6.00 | 5,726.13 | 34,356.78 |
| 36 | Supply o f subsidiary Signal Aspect - Shunt L E D a s p e r R D S O Specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 22.00 | 5,740.7 | 1,26,295.4 |
| 37 | Supply o f subsidiary S i g n a l A s p e c t - "A" m a r k e r a s p e r R D S O specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 5.00 | 5,150.7 | 25,753.5 |
| 38 | Supply o f Colour light Signal p o l e 140mm d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4.6m tall and 140 mm dia(Galvanised) | Numbers | 3.00 | 5,841 | 17,523 |
| 39 | Supply o f Colour light Signal p o l e 140mm d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3.6m tall and 140 mm dia (Galvanised) | Numbers | 5.00 | 4,737.7 | 23,688.5 |
| 40 | Supply o f surface base t o s u i t C L S Signal pole 140mm d i a w ith necessary inspection a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 8.00 | 6,814.5 | 54,516 |
| 41 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. a)Supply o f ladder with platform (4.6m) for CLS(Galvanised) | Numbers | 3.00 | 5,698 | 17,094 |
| 42 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary inspection a s p e r specification/ drawing/ description e n c l o s e d i n this document. b)Supply o f ladder with platform (3.6m) for CLS(Galvanised) | Numbers | 5.00 | 5,494.5 | 27,472.5 |
| 43 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as p e r specificatio n/ d r a w i n g / description enclosed in this document. | Numbers | 5.00 | 5,087.5 | 25,437.5 |
| 44 | S u p p l y o f G r o u n d t y p e s h u n t s i g n a l - complete w i t h surface b a s e , s i g n a l pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 4.00 | 7,463.5 | 29,854 |
| 45 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal unit (4 aspect) | Numbers | 3.00 | 19,470 | 58,410 |
| 46 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 5.00 | 14,278 | 71,390 |
| 47 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers | 1.00 | 22,260.7 | 22,260.7 |
| 48 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 6.00 | 3,663 | 21,978 |
| 49 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of "A" marker light | Numbers | 5.00 | 2,596 | 12,980 |
| 50 | Supply o f Off-set brackets - l a r g e / small made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 2.00 | 3,569.5 | 7,139 |
| 51 | Supply o f Off-set brackets - l a r g e / small made of cast iron with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 5.00 | 2,645.5 | 13,227.5 |
| 52 | Supply o f cable termination b o x (FRP type) w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. | Numbers | 10.00 | 7,788 | 77,880 |
| 53 | Supply of Signal post telephone with facility o f p a g i n g a n d talk-back including voice communication e q u ip m e n t w i t h suitable switching arrangement a t t h e Signal post a n d a t S M ' s r o o m a s p e r specification enclosed i n t h i s document. T h i s includes drawl of tail cable through GI pipe 25mm dia and 2 mtrs long duly clamped to Signal post with bend as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. T h e wiring shall b e d o n e using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box , w i r e PVC 16/0.20mm a n d all other miscellaneous materials required for the w o r k s h a l l be supplied by the Contractor]. | Numbers | 2.00 | 11,897.35 | 23,794.7 |
| 54 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 4.00 | 4,945.51 | 19,782.04 |
| 55 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set | 2.00 | 8,786.26 | 17,572.52 |
| 56 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d P o i n t contro l circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved circuit diagram a n d painting the particulars.[Wire P V C c o p p e r , 3 / 0 . 7 5 m m and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , f o r fixing resistors and condensers, MS flats 2 5 m m x 6 m m brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set | 1.00 | 11,355.02 | 11,355.02 |
| 57 | Concreting and erection of cable termination r a c k 500/210/140 Terminals capacity on teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as per standard practice.(Supply of cable termination racks a r e not included in this schedule).[Foundation b o l t s a n d nuts with washers, cement, sand, stone jelly, teak wood base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d all other miscellaneous materials required for the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity | Numbers | 1.00 | 9,752.74 | 9,752.74 |
| 58 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm w ith Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rac k shall be covered with phynolic s h e e t o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w o r k also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T F u s e b l o c k s i s not covered in the schedule) [Wire P V C 3 / 0 . 7 5 m m copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 200.00 | 167.99 | 33,598 |
| 59 | Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper bus bar for supply terminals, wiring, provision o f termination particulars diagram board using plywood of thickness 1 2 m m - teakwood finish of size 1800mm x 1200mm w ith Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rac k shall be covered with phynolic s h e e t o f thickness 3 m m wherever required. T h e termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e w o r k also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f PBT terminal blocks 25mm & 60mm centers and P B T F u s e b l o c k s i s not covered in the schedule) [Wire P V C 3 / 0 . 7 5 m m copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6 m m thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint a n d a l l o t h e r miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 20.00 | 201.27 | 4,025.4 |
| 60 | Supply of BIS listed Semi-automatic Stainless Steel preventive device w i t h UL approved c l e a n g a s w i t h A u t o manual Reverse Stainless S t e e l v a l v e ' N A S A 400 MAR' or similar having capacity of 4kg, and made of stainless steel 304 grade with Indian Railway logo put on each unit. | Per Unit | 2.00 | 35,219.46 | 70,438.92 |
| 61 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 1.00 | 23,192.34 | 23,192.34 |
| 62 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 1.00 | 33,510.29 | 33,510.29 |
| 63 | S u p p l y o f O T D R ( m i n i ) w i t h standard accessories f o r 1310/1550nm w i t h all standard accessories as per TEC specification GR/OTD-02/02 J a n 2 0 0 5 or latest, ( this item should h a v e v a l i d TEC approval certificate) as per Technical specification | Numbers | 1.00 | 3,07,856.22 | 3,07,856.22 |
| 64 | Supply o f Digital Insulation tester (Megger) 50V-500V/1000 mega ohm battery operated w i t h a l l c o m p l e t e accessories, a s per Technical specification | Numbers | 1.00 | 11,844.52 | 11,844.52 |
| 65 | Supply of Portable Cable Fault Locator as per Technical specification | Numbers | 1.00 | 1,86,694.53 | 1,86,694.53 |
| 66 | S u p p l y o f Fu s i o n Splicing M a c h i n e with accessories as per Technical specification | Numbers | 1.00 | 2,95,000 | 2,95,000 |
| 67 | Supply o f Double walled corrugated pipe - 103.5mm i n n e r d i a & 1 2 0 m m o u t e r dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2 ) : 2 0 0 1 w i t h o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification | Metre | 120.00 | 365.19 | 43,822.8 |
| 68 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 200.00 | 1,119.16 | 2,23,832 |
| 69 | Supply o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s p e r specification N o . I S 4984: 2016 with latest amendments a n d Material Grade:PE 80 | Metre | 280.00 | 853.55 | 2,38,994 |
| 70 | Supply a n d laying o f P V C Warning Tape colour Orange, width o f 250mm ( 1 0 " ) by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 2750.00 | 46.15 | 1,26,912.5 |
| 71 | Supply o f HDP E Pipe 4 0 m m (outer dia)/33 mm (inner dia) with couplers | Metre | 1000.00 | 60.93 | 60,930 |
| 72 | S u p p l y a n d I n s t a l l a t i o n o f Wall/Rack mountable 4 8 Fi b r e management system ( F M S ) conforming t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE m a k e o r better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos of Patch cords o f required length (All other materials required for splicing are to be supplied by contractor) | Numbers | 4.00 | 32,885.01 | 1,31,540.04 |
| 73 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. | Numbers | 30.00 | 1,622.5 | 48,675 |
| 74 | Supply of Track Feed Resistance | Numbers | 30.00 | 287.77 | 8,633.1 |
| 75 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 830.00 | 61.44 | 50,995.2 |
| 76 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 270.00 | 93.02 | 25,115.4 |
| 77 | S u p p l y o f P B T terminals 2 5 m m / 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 90.00 | 103.84 | 9,345.6 |
| 78 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe f o r cable entry a n d o n e G I pipe 150mm long 32mm dia for drawl of jumper w i r e s f o r P o i n t machines e t c . , fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. | Numbers | 8.00 | 5,029.69 | 40,237.52 |
| 79 | Installation of combined type point machine- I R S t y p e a n d c o n n e c t i n g a l l ground connections including wiring and termination i n p o i n t m a c h i n e a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision o f insulation to stretcher bars, throw b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat w ire P V C 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. | Numbers | 8.00 | 16,383.88 | 1,31,071.04 |
| 80 | Installation of Signal post telephone (paging and talk back) | Numbers | 2.00 | 5,392.75 | 10,785.5 |
| 81 | Filling e a r t h a r o u n d location boxes/signal foundations for a width of 0.5m on all sides, u p t o a level 150mm below t h e foundation top. This work includes consolidation of earth by watering and ramming.The earth shall be taken from Railway premises as instructed by Railway representative at site. | cum | 2.00 | 231.3 | 462.6 |
| 82 | Excavation of pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 8.00 | 9,213.28 | 73,706.24 |
| 83 | "Erection o f s u r f a c e b a s e , s i g n a l pole, mounting o f c o l o u r l i g h t s i g n a l u p t o 4 aspects complete o n S i g n a l p o l e / Off-set bracket, ( f o r L E D / fi l a m e n t b u l b s ) with lenses, t r i p l e p o l e l a m p holde r, filament switching u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h p l a t f o r m c o m p l e t e and concreting o f ladder shoe, fixing o f number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d w h e r e v e r necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3 / 0 . 7 5 m m copper, provision of EWS locks, and painting of one c o a t o f r e d o x i d e a n d t w o c o a t s of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall b e provided by drilling a hole i n t h e signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, l a m p holders, l a m p s , filam e nt switching u n i t a n d CLS transformer is not covered in this schedule). ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia , M sand, S i g n a l C o l l a r R i n g s , w i r e P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, l e a d w o o l , p a i n t s P V C / N y l o n sleeves, enameled number plates. enameled marker b o a r d s , E W S l o c k s , a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 8.00 | 8,287.08 | 66,296.64 |
| 84 | "Excavation o f p i t a n d casting concrete foundation as per Drg, No.SG/CN/02/10 using metallic templates, f o r erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 4.00 | 4,645.17 | 18,580.68 |
| 85 | "Erection o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, L E D aspects/ lense s, b u l b s w i t h holders (whichever i s applicable), fi x i n g o f lens guards, number plate, termination o f tail cables, wiring o f signal unit w ith P V C wire 3/0.75mm copper, provision o f E W S locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint.(Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule).[Wire PVC 3/0.75mm copper, lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 4.00 | 3,170.44 | 12,681.76 |
| 86 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f P o s t t y p e shunt Signals, termination o f tail cables a n d wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting o f one coat o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S post a n d provision o f a through bolt with nut to prevent the Off- setbracket from slipping down." | Numbers | 5.00 | 2,306.03 | 11,530.15 |
| 87 | Fixing o f junction type route indicators - 1 way to 6 ways - complete/ fixing of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply o f junction type Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS l o c k s , w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d w i r i n g of direction type route indicator - 3 way | Numbers | 1.00 | 2,679.26 | 2,679.26 |
| 88 | Fixing o f junction type route indicators - 1 way to 6 ways - complete/ fixing of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply o f junction type Route Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS l o c k s , w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. g)Fixing a n d w i r i n g of additional limb to existing route indicator | Numbers | 2.00 | 1,083.64 | 2,167.28 |
| 89 | Excavation o f p i t a n d construction of m a s o n r y p l a t f o r m a s p e r d r a w i n g No. SG/CN/02/12 w i t h country b r i c k s o f size 220mmx 100mmx60mm (app) at the foot of s i g n a l p o s t t e l e p h o n e s a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm ( a p p ) , cem ent, M sand a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 5,355.94 | 5,355.94 |
| 90 | H o t d i p Galvanization o f signal p o s t and ladder (4.6m tall, 140 mm dia /3.60 m tall,140 mm dia), clamps, point roddings and o t h e r m a t e r i a l s r e l a t e d t o Signalling. Minimum DF thickness shall be 80 microns. Transportation o f materials from site/stores t o galvanization workshop a n d b a c k to site/stores n o t i n c l u d e d i n this schedule.Transportation charges w ill b e as per "relevant SOR schedules. Test certificate showing t h e D F T , t y p e o f galvanization, materials used etc., from galvanizing firm for each batch to be submitted.(Unit is calculated based on the weight of the Signal poles, ladders, clamps, rodding's etc.,)" | Kg | 200.00 | 25.31 | 5,062 |
| 91 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 10.00 | 8,914.5 | 89,145 |
| 92 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 10.00 | 7,145.44 | 71,454.4 |
| 93 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 5.00 | 4,234.65 | 21,173.25 |
| 94 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling plan. This work includes provision o f d o u b l e bonding a n d parallel jumpers, provision o f b o n d w i r e c l i p s , wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 5.00 | 3,850.31 | 19,251.55 |
| 95 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly o f size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d all other miscellaneous materials required for thework shall be supplied by the Contractor.] | Numbers | 10.00 | 11,333.1 | 1,13,331 |
| 96 | " E x c a v a t i o n o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' t y p e l o c k f o r t h e f r o n t d o o r and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]""" | Numbers | 6.00 | 8,787.04 | 52,722.24 |
| 97 | E x c a v a t i o n o f p i t , e r e c t i o n o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm long a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for e a c h p i p e f o r c a b l e throughing, fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside w ith o n e coa t of red-oxide and two coats of aluminium paints. (Supply o f C T boxes i s n o t covered i n this schedule. Rails o f different length shall be supplied b y Railways. T h e contractor shall cut lengthy rails wherever required.) [ C e m e n t , M s a n d , s t o n e j e l l y o f size 20/25mm, paint, varnish, GI Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for e a c h p i p e , fi x i n g b o l t s a n d n u t s with washers, E W S locks, paints a n d a l l other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 8.00 | 4,999.16 | 39,993.28 |
| 98 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination racks a s p e r approved circuit diagram. The terminal particulars a r e to be r e p a i n t e d /correc te d o n t h e d o o r s of a p p a r a t u s c a s e s / b a t t e r y b o x e s / cable termination boxes and FTOT index board as instructed by Railway representative at site. T h i s w o r k includes c l o s i n g t h e opening created f o r e n t r y o f n e w c a b l e s i n the apparatus cases w i t h masonry brick work a n d sealing t h e bottom o f t h e apparatus cases/ cable termination racks w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit | 300.00 | 73.59 | 22,077 |
| 99 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." a)Termination o n 25/60mm P B T terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 600.00 | 172.14 | 1,03,284 |
| 100 | Termination o f m a i n , t a i l , Signaling and power cables and internal wiring on terminal/ fuse blocks i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , fi x i n g o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit e a c h a p p a r a t u s c a s e , v a r n i s h i n g all teakwood items, fi x i n g o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, w i r i n g , identifica tio n o f c a b l e s using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable p l a n , painting o f particulars o n sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M sand u p t o b a s e level a n d t h e bottom s u r f a c e s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not covered in this schedule)." b)Termination o n P B T f u s e b l o c k (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 40.00 | 209.93 | 8,397.2 |
| 101 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. a)Termination o f cables o n 2 5 / 6 0 m m PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 300.00 | 151.09 | 45,327 |
| 102 | Termination o f m a i n , t a i l , Signaling and power cables a n d internal wiring b y fixing additional terminals/ f u s e b l o c k s o n the existing terminal boards of apparatus cases, c a b l e termination b o x e s e t c . T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves and also o n the inner side o f t h e doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and t h e bottom surface s h a l l b e s e a l e d with sealing compound. b)Termination o f cables on PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 30.00 | 188.86 | 5,665.8 |
| 103 | Charging and installation o f secondary cells o f t h e following capacities, o n existing battery stand/ RCC slabs in the battery room. T h e w o r k involves charging of secondary cells, fi x i n g a n d connecting the batteries with strips, manufacture and fixing of t e a k w o o d t e r m i n a l b o x , termination of c a b l e s , w i r i n g w i t h s u i t a b l e w i r e PVC 7/1.40mm a n d 3/0.75mm c o p p e r through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame in the relay room. The particulars shall b e digitally using good quality "laminated gum sheet, provision of hydrometer -1 No. on a stand and battery tester-1 No. Charging of secondary cells shall b e d o n e b y the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [Teakwood plank 25mm thick for manufacturing termination box with locking facility, w i r e P V C 7/1.4mm a n d 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, a n d a l l other miscellaneous materials required f o r t h i s w o r k s h a l l be supplied by the contractor]." d) Installation o f 2V-40/80AH c e l l o n existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 48.00 | 615.08 | 29,523.84 |
| 104 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 3.00 | 3,972.14 | 11,916.42 |
| 105 | Provision of HDPE Pipe of dia 40/33 mm | Metre | 1000.00 | 26.11 | 26,110 |
| 106 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along w i t h rails, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. Also the resultant pits shall b e re-surfaced a n d consolidating by ramming and levelling" | Numbers | 1.00 | 1,580.36 | 1,580.36 |
| 107 | Releasing o f existing apparatus cases (Full/ H a l f / Quarter s i z e ) without d a m a g e after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, ' E ' t y p e l o c k s , e t c . , and breaking t h e c o n c r e t e foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. T h e released materials shall b e accounted a n d stacked a t a p l a c e a s instructed by Railway representative at site. | Numbers | 10.00 | 3,006.71 | 30,067.1 |
| 108 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with o r w i t h o u t R o u t e Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. T h e work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling. | Numbers | 5.00 | 3,083.03 | 15,415.15 |
| 109 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections and other accessories available c o m p l e t e w i t h o u t a n y d a m a g e t o the gadgets, accounting a n d s t a c k i n g them neatly a t a place a s instructed b y Railway representative at site. | Numbers | 10.00 | 2,698.69 | 26,986.9 |
| 110 | Releasing of existing TLD boxes with stumps a n d terminals after releasing a l l t h e bond w i r e s . T h e r e l e a s e d materials s h a l l be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 20.00 | 159.29 | 3,185.8 |
| 111 | Protection adjustments a n d re-instating of S & T gears by deputation of Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 50.00 | 847.59 | 42,379.5 |
| 112 | Protection, adjustment a n d reinstating of S & T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., f o r executing additional S & T p o r t i o n of w o r k s . T h e w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting b r i c k w o r k , wiring alterations, cable j o i n t i n g e t c a s per instruction of Railway representatives at size. | Man- Days | 25.00 | 1,073.45 | 26,836.25 |
| 113 | Transportation o f Signalling materials by r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also i n c l u d e s l o a d i n g a n d u n lo a d in g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 2000.00 | 22.75 | 45,500 |
| 114 | Transportation o f Signalling materials more than 100km | MT-Km | 500.00 | 13.91 | 6,955 |
| 115 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling any infringing structures, clearing and removing debris etc., w i t h a l l l e a d s a n d l i f t s etc., complete and a s p e r t h e instruction of Railway representative at site. | Hour | 32.00 | 1,202.5 | 38,480 |
| Schedule total | ₹1,11,97,552.07 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .