| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being lowest and competitive | |
| 2 | L2₹41.8 L+₹2.9 L (7.50%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Neither lowest nor competitive | |
| 3 | L3₹44.6 L+₹5.7 L (14.8%)Rejected-AOC BARIYAWAN BARIYAWAN BARIYAWAN BARIYAWAN AMBEDKAR NAGAR UTTAR PRADESH 224210 | AMBEDKAR NAGAR | UTTAR PRADESH | 224210 | L3 | Rejected-AOC Neither lowest nor competitive | |
| 4 | L4₹52.0 L+₹13.1 L (33.6%)Rejected-AOC | L4 | Rejected-AOC Neither lowest nor competitive |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Mar 2021, 6:00 pmClosed
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
REPAIR/REPLACEMENT CGI/PGI SHEET ROOFING FALSE CEILING BATH FITTINGS AND SUNKEN FLOOR ROOF TREATMENT TILING AND MISC ITEMS AT ZONE A AND REPAIR/REPACEMENT OF INTERNAL ELECTRIFICATION OTHER MISC WORKS AT 1 ARMY HQ
2021_MES_419853_1
GE/C-81/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt
₹98,000
Yes
17 Mar 2021
6 Feb 2021
6 Mar 2021
6 Feb 2021
4 Mar 2021
20 Feb 2021
6 Feb 2021 - 20 Feb 2021
Amount
M & L for repair of sunken floor treatment as per following steps and directed by Engr-in-charge : - (a) Demolition/dismentling of sanitary fixtures and fittngs and taking out and removing sunken floor fillinga way from bldg complete all as directed by Engr-in-charge (b) M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 mixed with WPC in mortar complete all as directed by Engr-in-charge (c) M&L for applying one coat of hot blown bitumen 85/25 grade @ of 1.20 Kg per Sqm on the plaster surfaces including verticla surfaces and laying APP polymeric water proofing membrane minimum 3mm thick and weighing not less that 3.5 kg per sqm of make ‘Superthemolay’ by STP Ltd or Hyper Plas Polyester manufactured by M/s IWL or Bengal supermat manufactured by M/s Bengal bitumen or SBS water proofing menbrane manufactured by M/s Modern bitumen Pvt Ltd or Torch tar Brand APP membrane of torchtar membranes & Bitumen products pvt Ltd over compatible bitumen primer @ 0.4 kg/sqm by torching application with a propane or butane gas torch with an overlap of 100mm at the sides and 150mm at the ends all as per manufactures instruction (d) Plain cement concrete type D2, 1:4:8 mix (using 40 mm graded brick aggregate) asin filling of sunken floors complete all as directed by Engr-in-charge (e) S&F 45cm long 25mm dia medium grade GI pipe as in spouts including making holes in RCC and making good in cement mortar 1:1/PCC 1:2:4 complete all as directed by Engr-in-charge. Note-01 : - Rates quoted are inclusive of taking down the existing sanitary fittings carefully i.e flushing cistren,flush pipe connection pipe, traps , CI pipes etc and fixing after completion of sunken floor treatment and fixture fittings required shall be included in quated rate . except floor trap required at site ponding test shall be carried out for 24 hrs for any leakage/seepage. Note -02 . WC and EWC, etc shall be consider under this item . Area of each sunken floor / slab is appx 2 to 2.5 sqm Note: 03 : Contractor shall have to render a guarantee for 10 year for the effectiveness of treatments & a FDR @ 10% of respective item shall be rendered for 10 year.
Taking down cement plaster on brick or stone wall etc. including racking out joints, hacking for key and scrubbing down with water etc. complete all as specified and directed by Enginer-in-Charge.
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and fair complete all as specified and directed by Enginer-in-Charge.
M&L for rendering 15 mm thick in CM1:6 finished even and smooth without using extra cement.including taking down cement plaster and raking out joints and scrapping down with water complete all as specified and directed by Enginer-in-Charge.
M & L for applying two coats of cement base paint on new plaster surfaces including preparation complete all as specified and directed by Enginer-in-Charge.
M&L for preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper(white or tinted) over a coat of chalk whiting on plastered surfaces M&L complete all as specified and directed by Engr in Charge.
S & F in repair 15 mm chromium plated fancy type wash basin mixer for mixing hot and cold water scrrwed down for iron pipe or brass ferrule complete all as specified and directed by Enginer-in-Charge.
S&F in repair health facuet with 1metre long flexible pipe along with nessesary fixing arrengment complete all as specified & directed by Engineer-in-Charge.
S&F in repair looking mirror 600x450mm bevelled edge 5.5mm thick high quality 4mm glass,dual hanging option of Prayag Cat No 553 and fixed to wooden plug with CP brass screws and cup washers complete all as specified and directed by Engr in Charge.
S&F PVC coated aluminium drapery curtain rod 20mm dia coloured with pair of suitable brackets and fennals as approved by GE including taking down old pelmet boxes with curtain rods, complete all as specified and directed by Enginer-in-Charge.
M&L preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Enginer-in-Charge..
M&L preparation of new/old steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Enginer-in-Charge..
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work and pre cast concrete articles complete all as specified and directed by Enginer-in-Charge.
M & L for dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed by Enginer-in-Charge.
M&L for joint less Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rect) area of each tiles exc .11 sqm but not exc 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including provn of 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and directed by Enginer-in-Charge.
M&L for joint less Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rect) area of each tiles exc .11 sqm but not exc 0.18 sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including provn of 10mm thick rendering of backing coat in CM 1:4 etc c complete all as specified and directed by Enginer-in-Charge.
M&L for joint less Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including provn of 15mm thick screed bed or bedding layer in CM 1:6 etc complete all as specified and directed by Enginer-in-Charge.
M & L for Vitrified tiles Dark Shade 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36sqm, but not exc. 0.42 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Enginer-in-Charge.
Material and labour for coloured glazed ceramic tiles 450x350 mm 7 mm thick in vertical surface set and jointed in neat cement slurry and pointing in coloured cement laid/fixed over 10 mm thick cement mortar (1:4) back coat complete all as specified and directed by Enginer-in-Charge.
S&F in repair vitreous china squatting pan (Orissa pattern) long pan (including provision of lime concrete bedding) of size 580x440mm white with intergral footrest including providing 100mm bore CI 'P' or 'S' trap complete all as specified (excluding flushing cistern and flush) complete all as specified and directed by Enginer-in-Charge..
Supply and fixing PVC Low level flushing cistern 10 ltr capacity incl internal fittings,sypons,handle,bend etc incl 2 Nos CI brackets complete all as specified and directed by Enginer-in-Charge.
M & L in repairs PVC connection 15mm dia of standard pattern 450mm long, with two Nos brass check nuts (adopts) and washers etc complete all as specified and directed by Enginer-in-Charge.
S & F in repairs for fancy type wash hand basin vitreous china white glazed flat back, size 550 x 400 mm, including brackets and cutting for and pinning in ends of brackets including provision of bottle trap and coupling etc complete all as specified and directed by Enginer-in-Charge.
S&F PVC waste pipe in repair of standard pattern, 32mm bore socketed end 600mm long for wash basin complete all as specified and directed by Enginer-in-Charge.
S&F 32 mm waste fittings in repair of brass chromium plated for wash hand basin with long screwed shank and flynut flange complete all as specified and directed by Enginer-in-Charge.
S&F solid PVC door frame in repair of size 50 x 47 mm made out of 5mm thick plain colour PVC sheet re-inforced with MS square tube, supplying and fixing in opening as per manufacturers instructions drawings and specifications complete all as specified and directed by Enginer-in-Charge.
S&F in repair factory made solid PVC moulded door shutter, 28 to 30 mm thick (Stiles), with 2,4 or 6 raised panel design with 2 mm thick 3D wood grain Moulded PVC sheet Polyurethane painted on the front face and 2 mm plain color PVC sheet on back face as per specification and drawing complete all as specified and directed by Enginer-in-Charge.
S&F in repair 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed by Enginer-in-Charge.
S & F in repair rotational moulded polyethylene water storage tanks tripple layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, 500 ltrs apacity.including float valve of PTMT 20mm size complete all as specified and directed by Enginer-in-Charge.
M & L for 15mm bore galvanised steel water tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc including taking down old one complete all as specified and directed by Enginer-in-Charge.
M & L for 20mm bore galvanised steel water tubing medium grade with all fittings (ISI Marked) and fixed complete to walls and or laid under floors etc including taking down old one complete all as specified and directed by Enginer-in-Charge.
S&F 15 mm dia Bib tap fancy type cast copper alloy chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrupe and fixed complete all as specified and directed by Enginer-in-Charge.
S & F in repair of ISI marked fancy type Pillar Tap of 15mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Enginer-in-Charge.
S & F in repair galvanised mild steel wire cloth, nominal dia of wire 0.63mm & average width of aperture 1.40mm, and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Enginer-in-Charge.
S&F 35 mm thick 2nd class hardwood glazed and skelton shutters open rebated and prepared to receive glass / gauze etc ( without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitered beads for securing glass etc size of members of shutters as specified in SSRpart-i section 8 clause 8.24(a) including one shop coat of pink primer complete all as specified and directed by Enginer-in-Charge.
S&F 35 mm thick factory made 2nd class hardwood plain framed panelled shutters/ any number member of panels) with panels of timber flat on both sides / feather edges) of veenered particle board medium density wood particle board with commercial face veeners complete all as specified and directed by Enginer-in-Charge.
Taking down chowkhat or frame with shutters (without taking off shutters from the frame exc 1.5 sqm but nexc 4 sqm each complete all as specified and directed by Enginer-in-Charge.
Taking down chowkhat or frame with shutters (without taking off shutters from the frame n exc 1.5 sqm each complete all as specified and directed by Enginer-in-Charge.
S& F steel window including pressed steel frame made of 1.25 mm thick MS sheet of size 125x60mm,double revated with side hung shutters both glazed and gauged incl box type hinges,steel handles and peg stay,tower bolts complete with glaze/gauge bars devotailed or welded incl one shop coat of red oxide primer (Wire gauge and glass panes shall be measured seperately) incl M & L for providing PCC type B-1 ,1:2:4(using 20mm graded stone aggregate) to fill the frame and making good complete all as specified and directed by Engr -in- Charge
S & F 150 mm long allumium anodised barrel tower bolts of extruded section complete all as specified and directed by Enginer-in-Charge.
S & F 150mm Extruded aluminium alloy handles, fabricated type,anodised handles complete all as specified and directed by Enginer-in-Charge.
S & F 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Enginer-in-Charge.
Supply and fix Aluminium alloy, anodised,sliding door bolt 300 mm with hasp,staple (bolt type) and fixingclips of sheet, cast or extrudedsections and fixing bolts andsliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Enginer-in-Charge.
S & F in repairs towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed by Enginer-in-Charge.
S & F in repair 125mm dia MS chromium plated grating with holes fixed in cement mortar (1:3) complete all as specified and directed by Enginer-in-Charge.
S & F Butt hinges, medium weight, cold rolled mild steel,100mm size complete all as specified and directed by Enginer-in-Charge.
Material and labour for 4 mm thick E-board ceiling of approved make as approved by GE, fixed with and including galvanized iron powder coated inverted ‘tees’ or ‘L’ sections (concealed GI frame work) suspended from ceiling with provision of galvanized iron wire 4mm dia and self tapping screws including butterfly clips, hold down clips for fixing the board to frame, including demolition of old ceiling board complete all as per manufacturer’s instructions a) Size of Main Tee- 38x38x1.5mm b) Size of Cross Tee- 29x24.7x0.8mm c) Size of wall angle- 25x25x1.5mm d) Size of grid-600mm x600mm Make : Lafarge, Armstrong, Ramco Industries Ltd.
M&L for roof treatment as per the description below :- Preparation of horizontal/vertical surfaces of brick/concrete /existing roof treatment roof surfaces also removing the , cleaning and washing down and make the surfaces free from dust and other conteminate Supply and fix APP polymeric water proofing membrane minimum 3mm thick and weighing not less that 3.5 kg per sqm of make ‘Superthemolay’ by STP Ltd or Hyper Plas Polyester manufactured by M/s IWL or Bengal supermat manufactured by M/s Bengal bitumen or SBS water proofing menbrane manufactured by M/s Modern bitumen Pvt Ltd or Torch tar Brand APP membrane of torchtar membranes & Bitumen products pvt Ltd over compatible bitumen primer @ 0.4 kg/sqm by torching application with a propane or butane gas torch with an overlap of 100mm at the sides and 150mm at the ends all as per manufactures instruction incl preparation of surface and applying a consistent coat of bituminous aluminum paint over APP surface complete all as specified and directed including taking down existing water proofing treatment and disconnecting water storage tank including connections for carrying water proofing treatment & placing the water tanks & making connections after carrying out water proofing treatment complete all specified and directed by Engineer-in-Charge Note : (The water proofing treatment shall be got carried out by manufacturer or their authorized applicators only) Note: 1. Contractor shall have to be render a guarantee for 10 year the effectiveness of treatments & a FDR @ 10% of respective item shall be rendered for 10 year.
Dismantling loose concrete cover of RCC columns,beams,slabs chajjas and the like as directed, roughening and cleaning concrete surfaces with steel wire brushes, washed with water and allowed to dry including derusting of steel reinforcement to providing fabric mild steel wire mesh 75X75X3 mm dia as reinforcement to concrete surfaces, applying adhesive admixture over steel mesh and providing minimium 40 mm thick (average thickness) guiniting mix using 1 part of ordinary portland cement 53 grade and 2 part of ghaggar sand mixed with the pressure of 2 to 2.5 kg per sqm by guinting machine including necessary plaster in CM 1:4, 10mm thick to match existing surface and surfaces finised even and fair. complete all as specified and directed by Enginer-in-Charge.
S & F in repair CP angle valve fency type 15 mm bore fixed to steel tubing complete all as specified and directed by Enginer-in-Charge.
M&L 75 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling as mass conc complete all as specified and directed by Enginer-in-Charge..
M & L Machine pressed precast concrete interlocking paver block with gray cement and no pigment any shape and size confirming to IS 15658-2006 of 60mm thickness over 25mm thick sand cishning M-35Grade complete all as specified and directed by Enginer-in-Charge.
M & L sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Enginer-in-Charge..
M&L 17 - 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete over and including 20 mm thick screed bed or bedding layer in CM 1:6 finished even and rough complete all as specified and directed by Enginer-in-Charge.
M&L for 19 mm thick block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work including exposed surfaces finished with external teak wood lipping, 6 mm thick fixed with nails complete all as specified and directed by Enginer-in-Charge.
M&L for 19 mm thickPrelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work including exposed surfaces finished with external teak wood lipping, 6 mm thick fixed with nails complete all as specified and directed by Enginer-in-Charge.
S&F of small fittings such as brackets of any type latch and hinge block, shaped door window stops and the like in second class hard wood article not exc 200 cucm each complete all as specified and directed by Enginer-in-Charge.
Supply only 50 mm size butt hinges, medium weight , cold rolled, mild steel and fixed complete all as specified and directed by Enginer-in-Charge.
M&L 40 mm thick cement concrete flooring 1:2:4 type B-1 using 20mm graded stone aggregate finshing even and smooth without using extra cemet complete all as specified and directed by Enginer-in-Charge.
M&L 75mm thick cement concrete 1:3:6 type B1 using 20mm graded stone aggregate as in plinth/sub base. complete all as specified and directed by Enginer-in-Charge.
Supply only intergal water proofing compound complete all as specified and directed by Enginer-in-Charge.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A) including taking down exiting unservisable/rusted truss/post/pruline complete all as specified and directed by Enginer-in-Charge.
S&F in repair Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Enginer-in-Charge.
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Enginer-in-Charge..
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded new metal flush box duly make embossed, concealed in walls with for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:-
One light/Exh fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
All as per item No 66 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 1.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6mm including 3 mm thick laminated top sheet cover including using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth all as specified and directed by Engr-in-Charge.
One light/Exh fan point controlled by one No one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm (nominal dia) FRLS 1100 Volts in existing PVC concealed conduit in new M S steel terminal boxes of wall thickness not less than 1.6 mm including 3 mm thick laminated top sheet cover including using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Enginer-in-Charge.
M&L in replacement switch piano 6 amp SP two way, ISI marked complete all as specified and directed by Enginer-in-Charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Enginer-in-Charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Enginer-in-Charge.
M&L in replacement switch piano flush button type single pole 16 Amps. complete all as specified and directed by Enginer-in-Charge.
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole . complete all as specified and directed by Enginer-in-Charge.
M&L in replacement regulator electronic switch type 5 steps suitable for 1200/1400 mm sweep 230 volts complete all as specified and directed by Enginer-in-Charge.
M&L in replacement bell electric (dingdong) 230 volt, SP complete all as specified and directed by Enginer-in-Charge.
M/L in replacement insulated body, angle holder (metal ring) with back plate ISI marked complete all as specified and directed by Enginer-in-Charge.
S&F ceiling rose surface PVC 65x50 mm type with three terminals. (For Exhaust Fans) complete all as specified and directed by Enginer-in-Charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 10Amps complete with one single pole MCB 'C' series 10 A capacity complete all as specified and directed by Enginer-in-Charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed by Enginer-in-Charge.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Mirror light) complete all as specified and directed by Enginer-in-Charge.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base. complete all as specified and directed by Enginer-in-Charge.
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Enginer-in-Charge.
S &F exhaust fan 300 mm in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor from ceiling rose to fan, length as per requirement at site. complete all as specified and directed by Enginer-in-Charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmmincluding writing MES NO. 2 CM height with synthetic enamelled black paint complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories (Concealed/Surface) in walls complete all as specified and directed by Enginer-in-Charge.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Surface) in walls complete all as specified and directed by Enginer-in-Charge.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified and directed by Enginer-in-Charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified and directed by Enginer-in-Charge.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of exhaust fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl make good of disturbed surface complete all as directed by Engr-in charge.
Supply and Fix in repair 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed by Enginer-in-Charge.
S & F PVC Gang box surface type heavy duty suitable for single 5 Amps switch & socket complete all as specified and directed by Enginer-in-Charge.
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Enginer-in-Charge.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :-
Sheet 4" x 4" single cutting suitable for one piano switch
Sheet 4" x 4" two cuttings suitable for two piano switches
Sheet 4" x 7" three cuttings suitable for three piano switches
Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , complete all as specified and directed by Enginer-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , complete all as specified and directed by Enginer-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 3 core PVC insulated of size 40/.0076 ll as specified and directed by Engr-in-Charge.
S & F hole fastner madeup of MS 6" long with complete nut bolt all complete all as specified and directed by Enginer-in-Charge.
S & F hole fastner madeup of MS 4" long with complete nut bolt complete all as specified and directed by Enginer-in-Charge.
S&F factory made epoxy powder coated switch disconnector fuse unit TPN with sheet metal enclosure confirming to IS 60947-3, 200Amps, positive isolation suitable for DIN & Bolted HRC fuse links fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts. complete all as specified and directed by Enginer-in-Charge.
S&F GI Pipe bracket bent to shape drilled welded made out of light grade GI pipe 25mm dia 1.5 mtr long and fixing on the wall where as directed by the Engr-in-Charge for fixing of building security light fitting including clamps, nuts, bolts and washers complete all as specified by the Engr-in-Charge .
Refixing of Ceiling fan / exhaust fan/ fresh air/ Wall mounted fan including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only.
M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
All as above item No 116 but 1400mm sweep complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge.
S&F in replacement capacitor of 2.5 MFD, complete all as specified and directed by Enginer-in-Charge.
Supply only gun metal bush of any size and make sutiable for ceiling fans 1200/1400 mm complete all as specified and directed by Enginer-in-Charge.
Supply only ball bearing No. 6202, complete all as specified and directed by Enginer-in-Charge.
Supply only ball bearing No. 6203, complete all as specified and directed by Enginer-in-Charge.
Supply only worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as specified and directed by Enginer-in-Charge.
S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Enginer-in-Charge.
S&F Ceiling fan blade suitable for 1400mm sweep of any make with suitable size as per site requirement complete all as specified and directed by Enginer-in-Charge.
M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as specified and directed by Enginer-in-Charge.
Supply only exhaust fan motor capacity 1/4 HP 230 volts suitable for 250 mm size exhaust fan complete all as directed.
Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only.
Supply only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site complete all as specified and directed by Enginer-in-Charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as specified and directed by Enginer-in-Charge.
S&F heating element of 2 KW triangular type with nut bolt washer complete all as specified and directed by Enginer-in-Charge.
M & L non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as specified and directed by Enginer-in-Charge.
M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
M & L chromium plated copper connection pipe 60 Cm long with two brass adopters and connecting up complete all as specified and directed by Enginer-in-Charge.
Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as specified and directed by Enginer-in-Charge.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 20 A capacity complete all as specified and directed by Enginer-in-Charge.
S &F Wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site complete all as specified and directed by Enginer-in-Charge.
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed by Engr-in-charge.
Note :- Total amount of Sch of credit is Rs. 124547.50 as per Sch of credit. Net contract sum shall be total quoted amount of bidder (-) amount of Sch of credit.
M/S ANIL KUMAR
m/s VK construction company
AMIT BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .