Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-Finance VILL BALIPOTA P O NARAJOLE P S DASPUR DIST PASCHIM MEDINIPUR PIN 721211 WEST BENGAL | NARAJOLE | PASCHIM MEDINIPUR | WEST BENGAL | 721211 | ₹10.9 L | L1 | Accepted-Finance LOWER BID |
| 2 | L2₹11.2 LRejected-Finance | ₹11.2 L | L2 | Rejected-Finance HIGHER BID |
| 3 | L3₹11.5 LRejected-Finance | ₹11.5 L | L3 | Rejected-Finance HIGHER BID |
Tender Value
Refer Docs
EMD Value
₹21,956
Closing Date
15 Dec 2025, 1:00 pmClosed
EE/KNED, PWD
P-5 CIT Road, Kolkata700014
SITC of Air conditioning Machine with allied EI work at Calcutta Technical School 110 SN Banerjee Road Kolkata 700013
2025_WBPWD_951634_1
WBPWD/EE/KNED/eNIT14/25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Calcutta Technical School
Please refer Tender documents
7 documents required · 7 mandatory
₹21,956
Kolkata North Electrical Division, PWD
3 Feb 2026
18 Nov 2025
17 Dec 2025
18 Nov 2025
15 Dec 2025
25 Nov 2025
24 Nov 2025
Dismantling the existing wiring with all allied accessories carefully & providing temporary arrangement and mending good damages to building works and hand over to competent authority as par direction of E.I.C.
Supplying and fixing 415V, 63A TPN Sheet steel Main Switches on angle iron frame on wall ( make- L&T, HPL)
Supplying and fixing double door 4 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING- Supplying and fixing 415V 63A FP MCB Isolator on din rail of existing DBs and necessary connection. -1 No. OUTGOING-Supplying and fixing 240V 32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-12 Nos. Blank Plate- 0 nos. (Make: Legrand / ABB / L&T)
Supply, carrying, handling, cutting, testing, sealing and laying on wall incl S&F of MS saddle with earthing attachment for 1.1 KV Grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098 (Part-I):1988 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith: [Gloster / Polycab / Havells / RR Kabel / KEI/ Mescab] a) 4 core 35 sq mm XLPE Al Ar cable (Panel to 4 way HTPN)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) 4 core 35 sq mm XLPE Al Ar cable
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : a) 4 core 35 sq mm XLPE Al Ar cable
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make : polycab/ Gloster/ RR kabel) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ for A.C]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5sqmm
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket ( make Legrand myrius), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing of timer control unit for single phase AC machine with front door locking arrangement , earthing attachment on wall consisting of the following items including necessary interconnection by suitable size of 1.1KV. Grade standared PVC insulated Copper wire ( Fire Retarant) and suitable AUTO/ MANUAL arrangement. a) Single door 12 way SPN DB or timer DB ----1no b) 40Amp DP MCB Isolator ----1no c)DIN mounted digital time switch with daily & weekly programmable basis , min switching time 1 min, ON/OFF programs,6 yrs. Battery backup, settable DST & key pad lock features. d) DIN Mounted 32ADP Power contractor with 250V, magnetic coil with two pole having one NO & one NC contact ---1nos e) Centre OFF 2-way toggle switch 1 no f) 32A barrier type Terminal ....1no g) One no. RED and one no. Green ,240V, LED indicator for indicating AUTO/ BYPASS indication---1 set h) 2x4+1x2.5 Sq mm Cu wire (Gloster/KEI/RR Kabel) ( Make: L & T/ ABB/ CRABTREE/ Havells)
Supply, installation, testing and commissioning of Split type AC machine having Cooling capacity 1.5 Tr with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating-3(ERR range 3.5 to 3.99), air flow range CFM(560-600), both condenser and cooling coils made of copper tube connecting cord with plug top including MS bracket confirming to IS 1391(Part-I & Part-II) with all amendments . (Make-Mitsubishi Electric/Mitsubishi Heavy/Daikin/ O-General)
Supply, installation, testing and commissioning of Split type AC machine having Cooling capacity range 2.25 Tr to 2.5 Tr with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating-3 (ERR range 3.5 to 3.99), air flow range CFM(925-1000), both condenser and cooling coils made of copper tube connecting cord with plug top including MS bracket confirming to IS 1391(Part-I & Part-II) with all amendments . (Make-Mitsubishi Electric/Mitsubishi Heavy/Daikin/ O-General)
Supply, installation, testing and commissioning of Split type AC machine having Cooling capacity range 1.8 Tr to 2.0 Tr with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating-3 (ERR range 3.5 to 3.99), air flow range CFM(780-850), both condenser and cooling coils made of copper tube connecting cord with plug top including MS bracket confirming to IS 1391(Part-I & Part-II) with all amendments . (Make-Mitsubishi Electric/Mitsubishi Heavy/Daikin/ O-General)
SITC including vacumization and nitrogen of testing of following normal size of soft/hard drawn copper refrigerent piping for package/ VRV/VRF/RAC system complete with fittings with adjustable ring type hanger supports jointing/brazing including accessories insulated with XLPE class O tubular insulation/with Class O closed cell elastometric nitrile rubber tubular sleeves section of specified thickness as given bellow for suction and liquuid lines. all accessories as per specification etc. as required. 1/4'' (6.4 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
5/8'' (15.88 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19 mm thick insulation.
Supply & laying PVC Drain pipe 25 mm dia with 6mm thick Nitrile Rubber insulation. (Suprime/Oriplast)
Supply & fixing of 3 core 2.5 sq mm Cu cable for inter connecting the indoor & outdoor units
Supply, fabrication,& fixing of MS U-channel of 6mm thick of size (75x40x40 mm) for making base frame/platform for installation of outdoor unit of above mentioned AC machines incl.drilling 2 nos holes in each chanel cutting holes into the wall and grouting the same with sand cement concrete (1:1& 1/2:3) fabricated with horizontal angle of 25x25x6mm and supporting angle 50x50x6mm in each platform in outer edge for transmitting the load centrally through two nos (50x50x6mm) angle inserted into the existing wall incl. fiber sheet shade as per direction of EIC.The entire Structure must be safe to carry out maintance of ODU as per direction of EIC
Note: 1) All the above rates should be quoted inclusive of all taxes & duties as applicable.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 1.15 MB
BOQ_2274859.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid