Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹87.1 LAccepted-AOC RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹88.2 L+₹1.0 L (1.20%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance other than L1 | |
| 3 | L3₹1.1 Cr+₹19.0 L (21.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L3 | Rejected-Finance other than L1 | |
| 4 | L4₹1.2 Cr+₹31.0 L (35.6%)Rejected-Finance 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | L4 | Rejected-Finance other than L1 |
| Sl No | Description | Qty | Unit | Third Wave Services Pvt Ltd L4 | Commercial Traders L3 | imran construction company L2 | M/S Chhavi Constructions Co L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified. | 4 | Cum | 500 ₹2,000 | 999 ₹3,996 | 100 ₹400 Lowest | 200 ₹800 |
| 2.00 | M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed. | 4 | Cum | 6,200 ₹24,800 | 5,999 ₹23,996 | 3,800 ₹15,200 | 3,000 ₹12,000 Lowest |
| 3.00 | Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. | 2,600 | Sqm | 25 ₹65,000 | 10.99 ₹28,574 | 10 ₹26,000 Lowest | 10 ₹26,000 Lowest |
| 4.00 | Ready mix plastering mortar solution
Base coat (minimum 5mm thickness or as per manufacturers instruction) applying finishing with water vapour permeable mortar, basecoat render for weather resistant & high performance façades with csv compressive strength. Flexural strength 22.5 n/mm2 and water vapour permeability 115 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material, slabs. pillars. roller blind boxes. around the openings/windows, doors, etc.), with fibre glass mesh to avoid cracks as per manufacturer's recommendations. Top coat (final finishing work) (minimum 10mm thickness or as per manufacturers instruction) finishing with the rainwater resistant and water vapour permeable coats rendering mortar, render applied in two for rainproof/weather resistant & decorative facades with a csi compressive strength class, flexural strength ≥ 2.5 n/mm2 resistance to water absorption as W2 (c≤0.2 kg/m2.mino.5), water vapour permeability ≤ 15 as per EN 998-1. The system includes the reinforcement of weaker points/areas (change in the substrate material slabs. Pillars, roller blind boxes, around the openings/windows, doors. etc.), with fibre glass mesh to avoid cracks as per manufacturer's recommendations. The color of the plaster to be selected by GE | 400 | Sqm | 1,000 ₹4,00,000 | 300 ₹1,20,000 | 300 ₹1,20,000 | 200 ₹80,000 Lowest |
| 5.00 | M&L for Ready mix plastering 15mm thick rendering on fair faces of brick or concrete surfaces wall for internal surface, finished even and fair without using extra cement, complete all as specified & directed. | 1,400 | Sqm | 490 ₹6,86,000 | 300 ₹4,20,000 | 190 ₹2,66,000 Lowest | 200 ₹2,80,000 |
| 6.00 | M&L for Ready mix plastering 15mm thick rendering on fair faces of brick or concrete surfaces wall for external surface, finished even and fair without using extra cement, complete all as specified & directed. | 550 | Sqm | 510 ₹2,80,500 | 300 ₹1,65,000 | 235 ₹1,29,250 | 200 ₹1,10,000 Lowest |
| 7.00 | M&L for Ready mix plastering rendering 10 mm thick in ceiling surface on concrete surfaces of ceiling complete all as specified. | 250 | Sqm | 440 ₹1,10,000 | 300 ₹75,000 | 190 ₹47,500 Lowest | 200 ₹50,000 |
| 8.00 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed. | 2,550 | Sqm | 35 ₹89,250 | 50.99 ₹1,30,024.5 | 55 ₹1,40,250 | 20 ₹51,000 Lowest |
| 9.00 | M&L for applying two coats of cement base wall care putty (water proof)1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving weather proof paint of any description, complete all as specified & directed. | 2,200 | Sqm | 35 ₹77,000 | 50.9 ₹1,11,980 | 75 ₹1,65,000 | 30 ₹66,000 Lowest |
| 10.00 | M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed. | 1,500 | Sqm | 35 ₹52,500 | 50.99 ₹76,485 | 55 ₹82,500 | 20 ₹30,000 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
10 Feb 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE NEW DELHI
HQ CWE NEW DELHI
SPL REPAIR TO BLD NO P-10 SINGLE NURSING QTR AT AHRR UNDER GE EM RR HOSP, DELHI CANTT-10
2026_MES_748602_1
CWE-ND/65/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE E/M RR HOSP DELHI CANTT
₹2.0 L
5 May 2026
15 Jan 2026
12 Feb 2026
15 Jan 2026
10 Feb 2026
5 Feb 2026
Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified.
M&L for brick work with sub class 'B' Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
M&L for Ready mix plastering mortar in two coats of overall thickness 15mm and minimum top coat of 10mm thick and the plaster has to be done through manufacturer/applicator complete all as specified & directed. Note-: plaster has to be done from plinth level to first floor roof beam.
M&L for Ready mix plastering 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and fair without using extra cement, complete all as specified & directed.
M&L for Ready mix plastering 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified & directed.
M&L for Ready mix plastering rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling complete all as specified.
M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed.
M&L for applying two coats of cement base wall care putty (water proof)1.5mm thick on plastered surface of wall and making the surface even & smooth for receiving weather proof paint of any description, complete all as specified & directed.
M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed.
M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint, complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed.
M&L for non skid colour ceramic tiles 7-8 mm thick (square/rectangular) area of each tiles exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors,dado/skirting etc, set and jointed with type - II (floor) tiles Adhesive of 6 to 8mm thick and pointed in white or colour grouting to match, complete all as specified & directed.
M&L for coloured glazed ceramic wall tiles as in vertical surfaces of size 600mm x 300mm x 7 to 8 mm thick, set and jointed with type - II (wall) tiles Adhesive of 6 to 8mm thick and pointed in white or colour grouting to match, complete all as specified & directed.
M&L for jointfree double charged Virified Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.72 sqm, in floors etc. set and jointed with type - II (floor) tiles Adhesive of 6 to 8mm thick and pointed in white or colour grouting to match, complete all as specified & directed.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area not exc 1.50 Sqm each, complete all as specified.
Taking down chowkats or frames including shutter (without taking off shutters from the frame) area exc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Providing and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including PVC leapping all as per direction of Engineer In- Charge.
Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER conssisting of density 650 Kg/CBM manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strengh and safety purpose (Confirming as per IS 4020). The door should be water prorf, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos. SS butt hinges size 100mmx25mmx2mm and 33mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws including PVC leapping all around door . etc. complete all as specified & directed. Note:- MTC and Screw out test will be provided by contractor.
S&F aluminium powder coated sliding window comprising of sliding runner of three way aluminium frame section (weight not less than 0.80 Kg/RM) as per series-A, consisting of three sliding shutters made out of section (weight not less than 0.55 Kg/RM) with 5.5mm thick glass and wiremesh (two No sliding glass shutters and 1 No wire mesh shutter) fixed with rubber and aluminium beading including down push type locking arrangement in shutter, fixed the frame with rawl plug complete all as specified and directed.(Note:- min thickness of powder coating not less than 50 micron.)
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified & directed.
S&F 100 mm long butt hinges, medium weight, cold rolled stainless steel and fixed, complete all as specified.
S&F 100 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm size extruded Stainless steel handles, fabricated type complete all as specified and directed.
S&F stainless steel, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections, complete all as specified & directed.
S&F 150 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
S&F in repair mild steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed.
S&F in repairs stainless steel curtain rod 20-22mm dia including brackets, side knobs etc, fixed to walls, complete all as specified and directed.
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length 140mm, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and pointed in any mortar, complete all as specified & directed.
M&L for 16-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.
Taking up or down 20mm bore steel tubing and connections, complete all as specified & directed.
All as per ser item No. 40 here-in-before but 25mm bore.
Supplying and laying of CPVC pipe 20mm dia SDR 11 and plain CPVC SDR 11 brass fittings on walls/ceilings or laying in floors including all necessary fittings complete all as specified.
All as per ser item No. 42 here-in-before but 25mm bore.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, complete all as specified & directed.
M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like incl weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed.
M&L for PVC floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement, including embedding with PCC 1:2:4 type B-1, complete all as specified & directed.
S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed.
S&F in repair white vitreous china wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including 32 mm size brass chromium plated waste coupling, etc, complete all as specified and directed.
S&F in repair European vitretious china wash down water closet pan P or S Trap (excluding flushing cistern but including flush pipe and pvc seat cover white).
S&F in repairs PVC low level flushing cistern, valve less, Syphonic action type, double push bottom, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and making connection complete all as specified.
S&F in repairs bib taps, cast copper alloy, fancy type, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs stop valves/angle valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type), with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm, all as specified & directed.
S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed.
S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed.
S&F in repairs shower rose, chromium plated brass, fancy type, 125 mm with or without swivel joint, any size, including fixing to steel pipe or union, complete all as directed.
S&F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as spd and directed
S&F in repairs 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as spd and directed.
Supply and fix in repair 1000 litres capacity double layer, rotational molded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe including dismantling tank, complete all as specified and directed.
Demolition of cement concrete (unreinforced)/lime concrete/sunken floor of any description and in any position not otherwise specifically provided for by mechanical means (like drill machine, Hilti, pneumatic chisel, etc) complete all as spd & directed.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) of any description and as in kitchen slabs, shelves, chimney, Chajjas etc not other specifically provided for complete all as specified and directed.
M&L of RCC of nominal mix type B0 1:2:4 (12.5mm graded aggreate) as in chajjas and like all as spd and directed by Engr-in-charge.
S&F in repair brass CP wall , sink, washbasin mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified.
S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to pipe all as spd and directed.
S&F factory made 18mm thick 100% solid WPC(Wood Polymer Composite) laminated board of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge.
M&L for followings :-(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr-in-charge may order sand blasting if rust is approved)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris and dust (ii) Applying Epoxy bond coat on the sound substrate using approved apray machine & ensuring that no pin holes are visible (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitoius mortar) of 25-50mm thickness. Note : Application of PMM sghall of preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed within 30mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer cmplete all as specified and directed.
S&F 100mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with lead joints, fixed to walls including dismantling old pipes any type complete all as specified and directed.
S&F 75mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with lead joints, fixed to walls including dismantling old pipes any type complete all as specified and directed.
S&F in repair 100 mm dia cast iron bends/Tee with oval access doors for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed.
S&F in repair 75 mm dia cast iron bends/Tee with oval access doors for spun pipes (any radious) with polymer jointing materials, complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls, complete all as specified & directed.
M&L PCC 1:3:6 Type C1 (using 20 mm graded stone aggregate ) in mass concrete for sunken portion of WC, complete all as specified and directed.
M & L for Water proofing treatment of sunken RCC slab : (i) 15mm thick plater in CM (1:3) mixed with WP compound as per manufacturer's instructions shall be provided on sunken portion while the concrete is green. (ii) Apply cement slury @ 0.488 kg/sqm cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/sqm and the surface will be allowed to air cure for 4 hours. (iii) Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to air cure for 4 hrs. (Make of cement composite compound of Dr. Fixit/Fosroc/Sikka) (iv) Curing the sunken portion with water minimum for 7 days by ponding. (v) Paste 200micron thick poythene film of approved make with approved adhesives to the treated sunken surface. (vi) Joints/Traps/WC/Soil pies shall be properly sealed with approved sealing compound of approved make. (vii) Testing of all traps & joints shall be done after sealing and before filling of sunken slabs and ponding test for 96 hours. (viii) Spout pipe shall be provided for drain out the water in sunken portion. Note : Flat surface shall be measured for payment.
M&L for TMT bars 6 to 8mm dia cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F 75 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
S&F of SS auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as specified.
S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified.
S&F Grating doom 100mm dia of SS (Minimum weight 35gms) all as spd and directed by Engg-in-Charge.
M&L for 25mm thick PCC 1:2:4 TYPE B0 using 12.5mm graded stone aggregate in sub baseof floor complete all as spd and directed.
M&L for machine pressed precast concrete interlocking tiles any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade laid including demolition of old tiles complete all as specified and directed.
M&L for sand filling under floors for cushion bed to interlocking paver block all as specified and directed.
M&L for Preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as spd and directed.
M& L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed.
M&L for Formwork tochullah hoods, chajjas, troughs and similar items including edges and fair finished all as spd and directed
M&L for Drilling & chemical anchoring of new rebars/stirrups :-(i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :-8 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item).
M&L for Drilling & chemical anchoring of new rebars :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 16 & 20 mm dia bar - drilling length 160 to 180 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA) with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete. (The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item).
Supply & fixing 12 mm dia steel sheer connector in grid pattern in between old core and new concrete as wherever directed by Engr-in-charge and as specified by manufacturer including drilling hole of depth of 100 mm and chemical anchoring with pure epoxy resin anchoring mortar (Master flow 935 of BASF or equivalent FOSROC/SIKA). ( The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item) complete all as specified and directed.
S&F powder coated anodised aluminium frame for windows, ventilators, grill with one or more rebates including necessary joining cleat, powder coated aluminium snap beading, screws for fixing etc. complete all as specified & directed. Note: (1) Only aluminium items to be measured. (2) Glass, wiremesh, handles to be measured & paid separately. (3) Minimum thickness of powder coating to be 50 micron.
S&F 4 mm thick pin headed or figured glass and glazing with oil putty in square n exc 0.5 sq. m in each pane including Taking out old serviceable glass of any description, from old wooden or metal frames, or stone, concrete or brick sur rounds, any thickness or size; hacking out old putty or removing beads etc, including making good breakages in taking out and handling removing to store or stacking for reuse , complete all as specified and directed.
M&L for 25mm thick PCC 1:1.5:3 TYPE B0 using 12.5mm graded stone aggregate in sub baseof floor complete all as spd and directed.
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendants, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty and applying colour / white wash finish complete all as specified and directed.
M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including PVC conduit of suitable dia, complete with all conduit accessories, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate / hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. (a) One light/fan/bell/exhaust fan point controlled by one switch.
(b) One 3 Pin socket outlet 5 Amps on Independent board.
(c) One 3 Pin socket outlet 5 Amps on same board.
(d) One light point controlled by two, two way switch
All as per srl item No. 100 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
M & L for point wiring of concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing in existing conduit, GI metal flush box of suitable for modular / conventional switches / sockets / fan regulators with cover plates, blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws etc as applicable will be included in quoted rates. (a) One light/fan/bell/exhaust fan point controlled by one switch.
(b) One 3 Pin socket outlet 5 Amps on Independent board.
(c) One 3 Pin socket outlet 5 Amps on same board.
All as per srl item No.100 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point.
S & F in replacement of Modular Switch 16 Amp, 1 Module with IP-20, single pole one way, ISI marked complete all as specified
S & F in replacement of Modular Socket 6 / 16 A - 2/3 Pin combined 2 module with IP-20 complete all as specified and directed
S & F in replacement of Modular Switch 1 way 6 /10 A, 1 Module with IP-20 complete all as specified and directed.
S & F in replacement of Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module with IP-20 complete all as specified and directed.
S & F in replacement of Modular Switch 2 way 6 / 10 A, 1 Module with IP-20 complete all as specified and directed.
S & F in replacement of Modular Bell push 6A 1 module , with IP-20, 240 Volts complete all as specified and directed.
S & F in replacement of Modular fan regulator step type, 120W, 240 V, with IP-20 complete all as specified and directed.
S & F in replacement of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed.
S & F in replacement of Bell Ding Dong, 240 Volts complete all as specified and directed.
Material and labour in replacement of Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB incl removing old sub main complete incl cutting chases etc all as specified and directed. Note : Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including PVC conduit of suitable size, complete with all PVC accessories and 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB / Panel to sub DB incl removing old sub main complete incl cutting chases etc all as specified and directed. Note : Cutting chases required for sub main wiring shall be finished with cement mortar 1:4 and surface shall be matched with existing shade of surface shall be deemed to be included in the unit rate quoted by the contractor.
Supply and fix Modular AC Box with MCB (25A, SP) Protected Socket, with sheet steel enclosure including Top Pin of 25 A, with indicator complete all as specified and directed
S & F in Replacement Decorative Cover for MCB Box, made of durable photo frame and hard board, with weather-resistant sticker having high-quality adhesive backing. Natural design / photographs as decided by the department will be placed and sticker for bottom line shall be printed with customized bilingual content as follows, SERVING THE SAVIOURS, GE E/M RR HOSPITAL, DELHI CANTT-10, "Save Electricity and Water – Every Watt Matters, Every Drop Counts", बिजली और पानी बचाएं – हर वाट की अहमियत है, हर बूंद की कीमत है", complete with mounting accessories and installation as per site conditions, final design to be approved by GE prior to printing, all as specified and directed for frame size of 18" x 14".
S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F in repairs Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed.
S & F in repair Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 8 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed.
S & F in repairs MCB, SPN, 63 Amps capacity, 240V, B Curve type, 10kA, double pole with over load and short circuit protection complete all as specified and directed
S & F in repairs MCCB, 125 Amps capacity, 415 V, B Curve type, 16 kA, with over load and short circuit protection complete all as specified and directed
S & F in repairs MCB, SP, 40 to 63 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
S & F in repairs MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed
Supply and fix in replacement Surface / wall mounted LED batten 20 W, luminaire made up of Extruded Aluminium Housing with PC diffuser, IP 40. The LEDs used should have a colour consistency SDCM≤5, CRI ≥ 80 and CCT 3000K to 6500K, (warm white to cool white adjustable type LED fitting) ≥ 120 lumen/watt, PF ≥0.95. The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed
All as per item Srl No 124 above but, 10 W and CCT 6500K
S & F in replacement Surface mounted, Microwave Motion Sensor LED light fitting 15 watt, Round Type, 240V, AC, 50 Hz, has an inbuilt Microwave motion sensor to dim the LED in case of no movement (auto-dim on inactivity), as long as the motion is detected, the LED flush Light glows at full brightness and it dims in case of no movement for 3 min, with PC diffuser, IP20 from dust. CRI ≥ 80 and CCT 6500K, ≥ 110 lumen / watt, PF ≥0.90, surge protection of min 2.5KV. The luminaire brand name shall be embossed / engraved on the luminaire / accessory / Endplate / Rim / Frame / end caps & not put using sticker / screen printing. The LED Luminaire & it's driver both should be BIS registered & shall be of the same make / manufacturer as that of LED luminaires complete all as specified and directed.
Supply and fix in replacement energy efficient wall mounted LED bulk head light fitting 10 / 12 watt, Outdoor IP 65, LED Bulkhead Light, CW 6500K , PF>0.95 and Voltage rated 220V to 240V etc complete all as specified.
S & F in replacement of LED street / security light fittings 25 Watt, with day night light sensor, high pressure die cast aluminium housing, IP 65 should have minimum efficiency at level >=110 lumens / watt, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, 240V AC, an operating voltage range of 140-270V complete all as specified and directed.
Taking down carefully and refixing ceiling / wall fan / Geyser of any size carefully and refixing complete with reqd fittings like new fasteners and all accessories reqd on site complete all as directed
S & F Fresh air fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 900 and CFM- 860 with Copper winding of sweep 250 mm complete all as specified and directed.
Labour for Taking down of electric meter with box of any make and type from the site and depositing it to the MES store all as specified and directed by Engr-in-charge
S&F of hot press moulded SMC meter box of inside dimensions 400x300x190 mm with hinged doors fixed in walls alongwith exisiting meter and making good to the disturb surfaces complete all as specified and directed.
M&L in replacement for laying, jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm x 3.5 Core in trench/ on pole/ in duct complete all as specified and directed. Note:- 1. The cost of required thimbles / clamps / fastner and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning, cable cover and Cable joints will be measured and paid separately under respective items of this sch.
Material & Labour for road cutting, including excavation, returning filling in, spreading, leveling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material or with PCC, rolled and compacted for road patch repair work, complete all as directed.
S&F in replacement of GI pipe of 80 mm nominal dia light grade with all fittings laid in trenches or under road crossing or fixed to walls/poles with clamps nuts, bolts and washers complete all as specified and directed.
Excavating in trenches in soft / loose soil, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out complete all as specified and directed.
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed.
Supplying laying, brick sub class 'B' common burnt laid in trenches for cable protection complete all specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 3 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.61 MB
tender65upl.pdf
Tender Documents • 1.79 MB
credit.pdf
Tender Documents • 0.19 MB
BOQ_838362.xls
BOQ • 2.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .