Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹28.4 L+₹1.2 L (4.23%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹28.9 L+₹1.7 L (6.24%)Rejected-Finance SHOP NO FF03 SHRISHTI PLAZZO COMMERCIAL SAINT XAVIER SCHOOL ROAD AVANTI VIHAR RAIPUR CHHATTISGARH 492006 | RAIPUR | CHHATTISGARH | 492006 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹32.4 L
EMD Value
₹64,700
Closing Date
28 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jabalpur
HQ Commander Works Engineer, Supply Marg, P B No. 54, Jabalpur
Provision of UGR of 50000 Gallons and connected E/M items at Naya Raipur under AMWP works
2020_MES_373182_1
86038/RPR/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
AGE (I) Naya Raipur
As per NIT
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹64,700
Yes
25 Jan 2021
29 Aug 2020
30 Sept 2020
29 Aug 2020
28 Sept 2020
14 Sept 2020
29 Aug 2020 - 14 Sept 2020
60 days
Amount
Basic Rate : Refer Schedule'A' Notes
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard/ dense soil complete all as specified and directed.
Excavation over areas, not exceeding 1.5m deep and getting out in hard/ dense soil complete all as specified and directed.
Excavation over area, exceeding 1.5m but not exceeding 3m deep and getting out in hard/ dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/ dense soil complete all as specified and directed.
Excavation in trenches in hard/ dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out including forming bottom surfaces to required level and slope complete all as specified & directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Moorum/ red bajri filling in floors or pavings, laid in layers not exc. 15cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
Supply and laying Sub Class 'B' old size bricks laid in trenches as cable cover all as specified and as directed.
M&L for Hard core of stone (granite/ basalt/ trap) boulders or broken stone of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and sub base of path/ paving etc complete all as specified & directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors and the like etc complete all as specified and directed.
PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate as in plinth courses, copings, benching, bed plates, bond stones, kerbs or mud stops etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
Supply only Integral water proofing compound (liquid) of make as approved by GE complete all as specified & directed.
M&L for providing precast reinforced cement mortar jallies 35 mm thick (measured solid) including all mouldings and wire reinforcement, set in cement mortar 1:4 complete all as specified & directed.
M&L for RCC design mix M-25 (using 20 mm graded stone aggregates) as in foundations, footing, plinth beams, bases for columns, mass concrete and the like etc for boundary wall complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for RCC design mix M-25 (using 20 mm graded stone aggregates) as in beams, cantilevers, bressummers & lintels over 1.50m clear span and the like etc; for boundary wall complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for RCC design mix M-25 (using 20 mm graded stone aggregates) as in columns, pillars, piers, posts and struts and the like etc; for boundary wall complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for RCC design mix M-30 (using 20 mm graded stone aggregates) as in foundations, footing, plinth beams, bases for columns, mass concrete and the like etc for UGR complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for RCC design mix M-30 (using 20 mm graded stone aggregates) as in walls, retaining walls, ballast walls and the like etc for UGR; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for RCC design mix M-30 (using 20 mm graded stone aggregates) as in slabs supported on walls in dome shape, beams and columns and the like etc for UGR; any thickness; complete all as specified & directed. Note:- Reinforcement shall be measured & paid separately under respective item of BOQ.
M&L for Brick work with fly ash bricks using modular size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation of UGR and the like etc for rough finished curved surfaces of concrete complete all as specified and directed.
M&L for form work to faces of curved walls of UGR, retaining walls, abutments, parapets and similar works including attachment pilasters, buttresses, columns etc vertical or to batter for fair finished curved surfaces of concrete complete all as specified and directed.
M&L for form work to soffits of suspended slabs such as roof slabs in dome shape and similar work etc; not exceeding 200mm thick (Horizontal or Sloping), for fair finished curved surfaces of concrete complete all as specified and directed.
M&L for form work to sides & soffits of lintels over 1.5 m clear span, floor or roof beams, cantilevers and the like etc of UGR for fair finished flat or curved surfaces of concrete complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams of compound wall and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for form work to sides & soffits of lintels over 1.5 m clear span, floor or roof beams, cantilevers, etc of compound wall for fair finished flat surfaces of concrete complete all as specified and directed.
M&L for form work to sides of square or rectangular columns, pillars, posts and struts etc of compound wall for fair finished surfaces of concrete complete all as specified and directed.
M&L for mild steel work of sections conforming to Fe.290.Gde-E-165 as in doors or gates of angle or other section with gusset plates, rails, braces, etc, drilled for fixing of steel sheeting or other covering; doors etc to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings inclusive of steel sheeting, running rails & guides and hanging, fastening & fixing complete all as specified & directed.
M&L for mild steel conforming to Fe.290.Gde-E-165 as in brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screws, ladders; and all other framed or unframed work of steel sections as required UGR, railings and similar work including applying one coat of red oxide zinc chromate primer before fixing to UGR complete all as specified & directed.
M&L for mild steel TMT bars 10mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia as in reinforcement for concrete, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 5 to 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Supply and fix plain, galvanised mild steel sheeting 0.63mm thick with grade of zinc coating 275 as in wall of RCC UGR, fixed to walls as a water seal as specified in TD drawing or any other means as directed complete all as specified. Notes:- For fixing details, refer TD drg No. CEJZ/ TD/ 984/ 2017 Sheet 1/1 dt 03 Nov 2017. Make:- Sail/ Tata/ Jindal as approved by AGE(I).
M&L for 50mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate with water proofing compound @ 2% by wt of cement or as per manufacturer's instructions as in floors of UGR, finished even & smooth using extra cement all as specified and directed. Note:- WPC shall be measured and paid separately under respective item of BOQ as "Supply Only".
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement forming joints to full depth at every 3M intervals and at every change of direction and filing with bitumen sand mixture 1:3 by weight complete all as specified and directed. Note:- Integral water proofing compound if asked for mixing, same shall be measured and paid separately under respective item of BOQ as "Supply Only".
M&L for 80mm thick rubber mould reflective factory made coloured pre cast PCC interlocking paver blocks/ tiles confirming to IS 15658-2006, M-40 designation of section as approved by AGE (I) in hard standing, laid dry over & including 50mm thick sand cushion and filling the voids of paver blocks/tiles with dry sand complete all as specified & directed. Make:- Mehtab Tiles, Indore (MP) or Nitco, Mumbai or Mayur Tiles & Interlocking pavers, Lucknow or Star Tiles & Industries, Ramadevi, Kanpur as approved by GE.
M&L for 10mm thick rendering in CM 1:4 with water proofing compound @ 2% by wt of cement or as per manufacturer's instructions on fair faces of concrete surfaces as in ceiling of dome, finished even and smooth without using extra cement complete all as specified & directed. Note:- WPC shall be measured and paid separately under respective item of BOQ as "Supply Only".
M&L for 15mm thick rendering in CM 1:4 with water proofing compound @ 2% by wt of cement or as per manufacturer's instructions on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed. Note:- WPC shall be measured and paid separately under respective item of BOQ as "Supply Only".
M&L for prepration of new plastered or concrete surfaces of walls/ dome and applying two coats of cement base paint over & including a coat of primer complete all as specified & directed.
M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over and including a coat of red-oxide primer complete all as specified & directed.
M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over already primed surfaces complete all as specified & directed.
Supply and fix CI work grade FG 150, unmachined, gully traps, gratings, railing, frames, man hole cover and similar articles for UGR complete all as specified and directed.
Supply and lay 150mm bore galvanized steel water tubing medium grade with & including all fittings heavy duty (ISI marked), laid in trenches complete all as specified & directed. Note:- Excavation and earth work shall be measured and paid separately under respective items of BOQ.
Supply and fix 100mm bore galvanized steel water tubing medium grade with & including all fittings heavy duty (ISI marked), fixed on walls/ ceiling/ floors etc complete all as specified & directed.
Supply and fix cast iron sluice valve 150mm bore, class PN-1.6 of make as approved by AGE (I),conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed.
Supply and fix cast iron sluice valve 100mm bore, class PN-1.6 of make as approved by AGE (I),conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed.
Supply and fix cast iron air release valve 150mm bore having double orifice (ball chamber) of make as approved by AGE (I), conforming to IS-14845, flanged end including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed.
Supply and fix cast iron air release valve 100mm bore having double orifice (ball chamber) of make as approved by AGE (I), conforming to IS-14845, flanged end including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed.
Supply and fix cast iron foot valve 100mm bore of make as approved by AGE (I), conforming to IS-4038, flanged end including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed.
Supply and intallation, connecting, testing & commissioning of monoset centrifugal pumps of capacity not less than 15.0HP having discharge capacity of 1200 LPM (minimum) at 34M head, three phase, 415 volts AC, electric driven complete all as specified & directed. Make:- Crompton Greaves/ KSB/ Kirloskar as approved by AGE(I).
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70sqmm, 3.5core including jointing materials such as cable glands & lugs etc and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by AGE(I).
Supplying and fixing/ laying of 50mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings ISI marked & necessary clamps, nuts, bolts, etc as required for fixing/ holding of pipe as in cable protection complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M/S INDIA ENTERPRISES
R K BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .