Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹34.4 L+₹215.88 (<0.01%)Accepted-AOC | L3 | Accepted-AOC BEING BONAFIDE AND LOWEST | |
| 2 | L1₹34.4 LRejected-Finance | L1 | Rejected-Finance NON BONAFIDE | |
| 3 | L2₹34.4 L+₹72 (<0.01%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance NON BONAFIDE | |
| 4 | L4₹34.4 L+₹216 (<0.01%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L4 | Rejected-Finance BEING LOWEST | |
| 5 | L5₹35.6 L+₹1.2 L (3.39%)Rejected-Finance 129 PANCH SHEEL VENUE DEEP NAGAR JALANDHAR CANTT PB | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹49.9 L
EMD Value
₹1 L
Closing Date
6 Apr 2021, 6:00 pmClosed
Sh ARJUN PATRO,GE (U) Elect Supply
GE U ELECTRIC SUPPLY DELHI CANTT
MANNING OPERATION AND REPAIR MAINTENANCE OF 11 KV SUB STATION AND LT PANEL AT SIGNAL ENCLAVE SANJAY VIHAR ANUJ VIHAR VIKRAM VIHAR YOGENDER VIHAR UNDER AGE U ES NOIII GE U ELECT SUPPLY DELHI CANTT10
2021_MES_431271_1
GE ELECT/D-113/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE U ELECTRIC SUPPLY
₹1 L
Yes
26 Apr 2021
18 Mar 2021
8 Apr 2021
19 Mar 2021
6 Apr 2021
1 Apr 2021
Amount
Manning & Operation in receivng-cum-Distribution sub Stn 11 KV by deployment of electrician in shifts as specified, including Sunday and holidays under the concern Area under GE (U) E/S Delhi Cantt as per the Schedule below (a) Signal Enclave 11 KV Sub Stn (i) 1 st shift from 0000 hrs to 0800 hrs one skilled electrician (ii) 2nd shift from 0801 hrs to 1600 hrs one skilled electrician (iii) 3rd shift from 1601 hrs to 0000 hrs one skilled electrician (b) Sanjay Vihar 11 KV Sub Stn (i) 1 st shift from 0000 hrs to 0800 hrs one skilled electrician (ii) 2nd shift from 0801 hrs to 1600 hrs one skilled electrician (iii) 3rd shift from 1601 hrs to 0000 hrs one skilled electrician (c ) Anuj Vihar 11 KV Sub Station (i) 1 st shift from 0000 hrs to 0800 hrs one skilled electrician (ii) 2nd shift from 0801 hrs to 1600 hrs one skilled electrician (iii) 3rd shift from 1601 hrs to 0000 hrs one skilled electrician (d) Vikram Vihar/Yogender Vihar 11 KV Sub Stn (i) 1 st shift from 0600 hrs to 1400 hrs one skilled electrician (ii) 2nd shift from1401 hrs to 2200 hrs one skilled electrician (iii) 3rd shift from 1601 hrs to 0000 hrs one skilled electrician
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day per shift (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
Dismantling the existing corroded/damaged LT pannel/feeder pillar boxes of any size by disconnecting all the incoming / out going cables, sealing the cable ends, disconnecting incoming / out going MCCB's from bus bar chamber and removing all the items
Labour and T&P only for Taking out LT cable loop of any size by execavation and taking out all material as required for connecting of cable to new LT panel including relaying the remain cables in same trench after making connection and testing complete all as specified and directed.
Supply, installing, testing and commissioning LT Panel outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 50 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). LT panel mounted on 02 Nos, Brick pillars including excavation and earth work (PCC 1:2:4) type B1, brick work 1:4 and 15mm plaster of cement (1:6). The LT Panel should proper spacing to accommodate all accessories, cable connection with suitable size of lugs /thimbles and cable glands comprising of the following :- (a) Aluminium bus bar 3 phase and neutral 600 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 400 Amps, with breaking capacity 35 KA at 415 volts microproccer release, adjustable type - 01 No, (In comming) (c) MCCB, 03 Pole, 250 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 03 No, (Out going). (d) MCCB, 03 Pole, 160 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 02 No, (Out going) (e) Indication lamps R,Y,B LED type with 3 Nos of 5 A MCB SP – 1 set. (f) Digital Amp and volt meter AC. NOTE : All MCCBs should have Ice 100% Ics .
Supply, installing, testing and commissioning LT Panel outdoor type stainless steel (SS 316) cubical enclosure compartmentalized exterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2 mm thick SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 50 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than 20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm). LT panel mounted on 02 Nos, Brick pillars including excavation and earth work (PCC 1:2:4) type B1, brick work 1:4 and 15mm plaster of cement (1:6). The LT Panel should proper spacing to accommodate all accessories, cable connection with suitable size of lugs /thimbles and cable glands comprising of the following :- (a) Aluminium bus bar 3 phase and neutral 400 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) MCCB, 04 Pole, 250 Amps, with breaking capacity 35 KA at 415 volts Adjustable type - 01 No, (In comming) (c) MCCB, 03 Pole, 160 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 02 No, (Out going) (d) MCCB, 03 Pole, 125 Amps, with breaking capacity 25 KA at 415 volts Adjustable type - 02 No, (Out going) (e) Indication lamps R,Y,B LED type with 3 Nos of 5A MCB SP – 1 set. (f) Digital Amp and volt meter AC.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
Ridhi engineers and builders
Buddham Builders
M/s Adhikari construction co.
S S CONSTRUCTION
MV Engineers And Contractors
mayur enterprises
Vijay Electricals
New Era Engineers
Microsys Controls India
Choice india
ENVIRO TECH SERVICES
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .