Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹34.4 L+₹5.7 L (19.9%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹49.2 L+₹20.4 L (71.1%)Rejected-Finance 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Firm is not enlisted in appropriate category i.e. b(iii). | |
| 5 | Rejected-Technical | - | Rejected-Technical Firm is not enlisted in appropriate category i.e. b(iii). |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/REPLACEMENT AND IMPROVEMENT TO 33 KV GANTRY STRUCTURE,CONTROL AND TRIPPING SYSTEM AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
2022_MES_503047_2
8121/SAR-66/E8 REPAIR/REPLACEMENT AND IMPROVEMENT
Open Tender
Civil Works
Item Rate
183 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹60,000
Yes
30 Apr 2022
25 Feb 2022
14 Mar 2022
25 Feb 2022
12 Mar 2022
26 Feb 2022
25 Feb 2022 - 26 Feb 2022
60 days
Amount
Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge. Note : 18 cm thick only will be considered for pryment purpose.
M&L for precast concrete cover class HV type 1, flat size 300mmx180mmx40mm laid in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply, laying testing and commissioning in replacement trenches /passing through pipes/ on poles etc cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with stranded aluminium conductor, 11000 volts, grade of size of cable 185 sq mm 3 core suitable for earthed system including taking out unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note :- ( Excavation & Earth work, Sand cushioning and precast concrete cover shall be measured and paid separately under relevant items of Sch. ‘A’).
Disconnecting HT/LT cable and earthing connection of defective HT AVR 33 KV of capacity 2 MVA, i.e, regulator and transformer unit, taking up & down from site of installation with the help of Hydra/Crane and transporting the same to workshop for repair by suitable transport means i. e compatible in size with 2MVA HT AVR, dismantling both the unit i. e, regulator and transformer, draining the transformer oil, taking out the core assembly, removing burnt out winding, finding faulty /UNSV parts, dehydrating the core assembly, filtered /dehydrating topping up new oil, testing , reassembling AVR after repairing including transportation back to site, installation with suitable fastening element making cable connection and earthing connection, testing and commissioning complete all as specified and directed by the Engr-in-Charge
Dehydration and filtration of the existing transformer/servo voltage stablizer oil by Dehydration plant to achieve di-electric strength of 40 KV at the gap of 2 mm complete all as specified and directed by Engineer-in-charge.(Dehydration plant shall be brought at site by the Contractor) and shall also include the following provisions :- a) Testing of transformer /servo voltage stablizer oil before & after dehydration shall be carried out as directed. b) The Unit of Payment under this item shall be per liter of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every eqpt as per format given by Engr-in-charge and submit the same to Engr-in-charge.
Supply and filling transformer oil for topping up or replacement in different existing transformers outdoor/indoors/AVRtype of any capacity located and installed at different places and different height complete all as specified and as directed by the Engineer-In-Charge. Note: - Transformer Oil:- The complete material shall be brought at site and then as per requirement oil should be shifted to site.
S&F new aluminium conductor steel conductor steel reinforced (ACSR) ( weasel), straining properly on insulator and binding with aluminium tape/ binding wire connector, PG clamps, jumper etc after taking down/out conductor as existing at site complete all as specified and as directed . Note:- 3% for sag shall be added in straight measurement.
Taking down/out old unservieable air break gang operated switch,removing GOD including supply ,erection testing and commissioning of 33 KV isolator 3 pole single throw double break three posts per phase central pole roatating type manually operated in horizontal plane and shall have high pressure relieving type fixing contacts made of hard drawn electrolytic copper . The switchblades forming the moving contacts shall be siliver plated. Each isolator shall be provided with bimetallic clamping type of connector suitable for ACSR 0.2 Sqm inch. The isolator shall have on , off indicator pad locking arrangements complete all as specified and as directed.
Cleaning and painting to all metal parts of 33/11 KV main receiving station yard comprising of incomer structure , 04 Nos 33 KV ways MS structure with complete accessories , chain link facing around yard and applying two coats of aluminium paint on all metal parts and white wash to PCC/Brick structure, external surfaces of transformer platform including fire walls etc complete all as specified and as directed.
Supply and fixing in replacement three phase Amp meter ranging from 0-100 Amps digital type, of size 100 mm complete all as specified and as directed.
Supply and fixing in replacement three phase Voltmeter ranging from 0-15 KV digital type of size 100 mm complete all as specified and as directed.
Supply and fixing in replacement LED indicator lamps set (RED / YELLOW / BLUE) complete all as specified and as directed.
Supply and fixing 3 phase over current and earth fault relay with instantanteous high set functions after taking down/out relay as existing at site complete all as specified and as directed. Make L&T or equivalent in Legrand and Crompton Greaves.
Taking out old unsv existing control cable of any type/any size of 1 MVA/2 MVA transformer or AVR breaker panel installed in 33 KV yard from trench/duct with proper safety arrangement complete all as specified and as directed by Engr-in-charge.
Supply and fixing control cable to 1 MVA/ 2 MVA transformer or AVR breaker panel installed in 33 KV yard of size 2.5 sqmm 12 core solid armoured copper cable with necessary fastening elements and with saddles complete all as per site requirement and specified by Engr-in-charge.
Supply and fixing control cable to 1 MVA/ 2 MVA transformer or AVR breaker panel installed in 33 KV yard of size 2.5 sqmm 16 core solid armoured copper cable with necessary fastening elements and with saddles complete all as per site requirement and specified by Engr-in-charge.
Supply and fixing control cable to 1 MVA/ 2 MVA transformer or AVR breaker panel installed in 33 KV yard of size 2.5 sqmm 8 core solid armoured copper cable with necessary fastening elements and with saddles complete all as per site requirement and specified by Engr-in-charge.
Material and labour for re location of 11 KV VCB panel after removal of incoming & outgoing HT cable connections & control wiring complete coupling VCB with busbar of existing VCB panels including making necessary modification to cupler bus bar of 630 Amps rating to accomodate these VCBs as continous bus bar complete all as specified and as directed.
Material and labour for re location of 33 KV/11 KV control and relay panel after removal of incoming & outgoing HT cable connections & relocate the 33 KV control and relay panel in substation,then doing the control wiring after that relocate the cable & make the conections of incoming & outgoing HT cable & make it functional complete, according to direction of Engr-in-charge complete all as specified and as directed.
Material and labour to convert 11 KV VCB into 11 KV bus bar coupler completed with modification to bus bar, internal wiring , electrical and mechanical interlocking with existing system complete as per direction of Engr-in-charge complete all as specified and as directed.
Taking out trolley of vacuum circuit breaker 630/800 Amps 11 KV from the cabinet and opening top cover, de-carbonizing moving and fixed contacts if required, lubricating, inspecting the wiring of Micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system complete and placing back the breaker trolley in its original position all as specified and as directed by Engr-in-Charge.
M&L for replacement of fixed contact block complete suitable for 630/800 Amps, 11 KV HT VCBs complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of moving contact block complete suitable for 630/800 Amps 11 KV HT VCBs Complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of mechanical castle interlock assembly with key suitable for HT 11 KV VCB of rating 630 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of closing coil assembly 230 volts AC/ 24 volts DC, complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Tripping coil with plunger assembly 230 volts AC/24V DC, complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of closing coil plunger with 24 volts DC, Complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of spout bushing 11 KV for VCB complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of HT 11 KV PT HRC Fuse complete all as specified and directed by Engineer-in-Charge.
Callibration of microproccessor E/F and O/C relay of VCB complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with main grid for proper functioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing only in replacment of Vaccum interruptor type WL-33379 (4 inch dia) suitable for HT VCB 630/800 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement trip push button suitable for HT 11 KV OCB/VCB.
S&F in replacement of shunt trip coil 30 volts DC for HT OCB/VCB all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement motor and gear assembly 110 volts AC/24V DC UMG-14 type complete all as specified and directed by Engineer-in-Charge.
Supply & Fix in replacement of isolating contact assembly suitable for 630 Amps HT VCB complete all as specified and directed by Engineer-in-Charge.
S&F in replacment of Power pack with battery backup 110V AC/30V DC &nconnected to HT PT secondary circuit including testing for triping complete. complete all as specified and directed by Engineer-in-Charge.
Supply and installations as in replacement of voltage transformer (PT) 3 phase, 3 limb indoor type primary voltage 11 KV and secondary voltage 110 volts type VA class complete all as specified and directed by Engineer-in-Charge.
Supplly & Fix in replacement of Master trip relay suitable for working voltage 30 Volt DC and connecting the circuit with existing over current and earth fault relas complete all as specified and directed by Engr-in-charge.
Opening the front and rear cabinate of the RMU 3way 630Amps 11 KV de-carbonizing moving and fixed contacts if required, lubricating, checking the pressure of SF-6 gas, inspecting the wiring of micro processor EF/OC relay, tripping coil electrical and checking for manual/auto tripping system complete and placing the SF-6 VCB and isolating unit in its original position all as specified and as directed by Engr-in-Charge. Note: (i) The various unsv items required to be replaced shall be paid seperately under item No. 44 to 53. (ii) Calibration of relays shall be paid seperately under item No. 52.
Supply and fixing in replacement of plug in type voltage presence indicator system (VPIS) type WIM for 11 KV, RMU complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of SF-6 Ring Main unit fuse 11 KV by opening fuse canisters of RMU positioned behind interlocking cover complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of terminal contact piece with silicone coupling for SF-6 Ring Main unit 11 KV by opening the terminal cover complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of pressure indicator manometer for SF-6 Ring Main unit 11 KV by opening the front cover complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of ring type current transformer 50/1 Amps for SF-6 Ring Main unit 11 KV by opening the cable compartment cover of fixed the CT on cable elbow plug/T plug complete all as specified and directed by Engineer-in-Charge.
Supply and filling SF-6 gas in safe ring/safe plus by SF-6 gas bottle by removing front cover and on screw manometer and reduction valve and maintained the pressure 14 bar absolute complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Trifurcation boot 11 KV capacity for cable termination joint of RMU incoming and outgoing terminals including taking out old defective trifurcation boot complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of HT bushing with gaskit for SF-6 Ring main unit 11 KV complete all as specified and directed by Engineer-in-Charge.
Callibration of microproccessor E/F and O/C relay of RMU complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with main Tech area power house incl replacement of relay battery for proper functioning complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement of earth fault protection and indicator relay for Ring main unit including callibrating the relay with existing load and tripping timming complete complete all as specified and directed by Engr-in-Charge.
Cleaning and prepartion of surface of VCB panel of 33/11 KV main receiving station and applying two coats of existing siemens light gray paint over a coat of zinc oxide primer complete all as specified and as directed. Noted-1. Quaoted rate included the identification mark sheet plate fitted on each feeder with matching color of VCB .
Supply and fixing in replacement of epoxy resin cast insulator cylinderical shape with capicity11 KV complete all as specified and as directed.
Repair ,maintenance & servicing of 33 KV ,2000 KVA AVR regulator unit complete by lifting of coil assembly with hydra, checking/cleaning of all cable connections removal of carbon /dust particles, checking alignment of carbon roller assembly and replace of defctive parts and lowering of coil assembly and testing complete .(Note: Defectives parts shall be measured & paid seperately)
Supply only following parts of 2MVA 33 KV AVR unit Carbon roller assembly
Tag & tail assembly
B4c limit switch
PCB relay
Supply and installation of rated voltage 33 KV, Highest system voltage 36 KV, single phase, out door oil cooled CT of ratio50-25/5+5A Amp, class 1.0 / 5P20, burden 30 VA- 30VA, PS class, Vk≥600V at lower ratio, Ie < 30 ma at Vk/2 in lower ratio, Rct<10 Ω at higher ratio, rated short circuit current 20KA for 3 sec, Rated Dynamic current 50 KA(Peak), conforming to IS-2705-1992 (part-IV)/IEC- 185, IEC-60044 2 years warranty from date of installation of any part of equipment all as specified and directed by Engr-in-Charge.
Disconecting HT conductor and Earthing connections of burnt/defective oil cooled 33 KV PT 3 phase from pole from pole, taking down from site of installation carefully and transportation of the same to workshop for repairs, draining out the oil, dismantling complete and taking out the core assembly and removing brunt out windings, dehydrating the core assembly, reassembling PT after rewinding, filtred/ dehydrated, topping up new with new oil, carrying out routine tests, including transportation back to site, testing full load after making conductor and earthing connections complete all as specified & as directed.
Disconecting Primary & secondary side cable and Earthing connections of transformers of capacity 1000 KVA , 33 kv/11 KV volts 3 phase shifting to open space within the yard with the help of crane for repair / increase of Transformer plinth foundation PCC height and shifting back of Transformer after proper curing of PCC work of foundation making cable connection complete all as per original. (Note:- PCC will be measured and paid saperately).
M&L for pcc 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface broken stone or boulders
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt all around earth plate, test point of phosphorous bronze / gun metal of size 75 mmx 75 mm x25 mm, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Material and labour for rewinding of 33 KV, HT AVR 2 MVA capacity outdoor type, HT/LT side coil/strip with super enameled copper wire/strip of suitable size/gauge as per original, fixing the coil/strip in position in core assembly and making connection as per manufacturer specification complete all as specified and directed by the Engr-in-Charge Note; all work pertaining to 33 KV, 2MVA AVR i.e, rewinding & servicing to be carried out through vender having expertise in repair/maint in such type of jobs and having following minimum testing facility :- (a) HV test- 70 KV (b) DV test - 485 X 2V (c) DF test - 50x2Hz (d) Oven dimension- 12X12 Ft (e) Proof of above shall be submitted to Engr-in-Charge before execution of the work.
Supply and fixing in replacement 32 x 6 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engineer-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified & as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing Kit for 11 KV (E) grade cable for straight through heat shrinkable type joint with jointing material and accessories for 95 sqmm 3 core XLPE, HT cable including cutting after taking down/out joint kit as existing at site complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
Supplying, fixing, connecting, testing and commissioning cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
Supply and fixing in replacement of Annunciator 24V , 9 Window suitable for 33KV C&R panel complete all as specified and directed by Engr-in-charge.
SHRI RAM ENTERPRISES
KAPOOR ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .