Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.5 L+₹75,996 (2.64%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.8 L+₹4.0 L (14.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹33.4 L+₹4.6 L (16.1%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.9 L+₹8.1 L (28.3%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
10 Jun 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR REPLACEMENT OF HIGH MAST LIGHT, GARDEN LIGHTS AND OTHER CONNECTED ITEMS AT VARIOUS LOCATION UNDER GE NAGROTA
2024_MES_653367_1
CA NO GEN-10/2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAGROTA
Class D category b i
8 documents required · 8 mandatory
₹500
Yes
GE NAGROTA
₹80,000
Yes
14 Sept 2024
10 May 2024
18 Jun 2024
10 May 2024
10 Jun 2024
28 May 2024
Amount
SCHEDULE ‘A’ PART-I Supply and fixing in replacement of automatic street light switch astronomical time switch 32 Amp for automatic switching of street light. The time switch along with suitable power contactor, MCB and support terminal should be enclosure made of rust proof, electric shock proof as per manufacurers recommendation, IP 66 conforming to IEC including contactor and incoming - outgoing MCBs rating of suitable capacity including necessary connection by providing circuit copper wiring with minimum 10 Sqmm cable incl taking down old one complete all as specified and directed. Make: IndoAsian -TL032ASO or equivalent make as specified in PS
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 60 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. incl taking down old unsv light fittings complete all as specified and directed. Make: Orient Cat part No LSFS-060-PC or equivalent make as specified in PS
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Incl taking down old unsv light fittings complete all as specified and directed. Make: Orient Cat part No LSFS-090-PC or equivalent make as specified in PS
S&F of 120W LED Flood Light made up of pressure die cast Aluminium Housing with toughned glass and high power LEDs and secondary lenses with IP 66 protection. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Incl taking down old unsv light fittings complete all as specified and directed . Make : Orient Cat part No LFSM-120-C-V3 or equivalent make as specified in PS
S&F of 180W LED Flood Light made up of pressure die cast Aluminium Housing with toughned glass and high power LEDs and secondary lenses with IP 66 protection. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Incl taking down old unsv light fittings complete all as specified and directed . Make : Orient Cat part No LFSM-200-C-V3 or equivalent make as specified in PS
S&F in replacement old broken post top Lantern of capacity 20 W energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable for working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including 15 Watt LED Bulb complete with electrical connection with fixing arrangement 50 mm Conduit pipe/ GI pipe complete all as specified and directed .HPL Cat part No HPLLEDPCR 20W or equivalent make as specified in PS
S&F in replacement old broken post top Lantern of capacity 12 W energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable for working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including 12 Watt LED Bulb complete with electrical connection with fixing arrangement 50 mm Conduit pipe/ GI pipe complete all as specified and directed .HPL Cat part No HPLLEDPDC12W or equivalent make as specified in PS
Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc. Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge. (Note- Accessories/components required for replacement i.e Driver, Surge protection device shall be measured and paid separately under relative item of Sch 'A' ) Note : Contractor responsibility is to liase with the department concerned for LT supply shut down required to carry out the work & also ensure the safety of labour employed by giving them safety equipments like helmet, gloves, safety belt , discharge rod etc and nothing extra shall be permisissible in this account.
Supply and fix 9 W LED bollard light fitting with opal arylic diffuser and IP 65 protection powder coated square extruded aluminium housing. Mushroom Shape Opal acrylic diffuser is fixed in die cast aluminium frames on four sides for pleasant light output with inbuilt driver with 4.5 kV surge protection.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal.LEDs mounted on top die cast aluminium housing and can be separated from base plate for easy maintenance. Make HPL cat part No HPLLEDB9W or equivalent in Bajaj,CG,Havells
S&F Mounting arm for installation of LED light made from 40mm bore GI pipe light grade of total length 1.5 mts (to be fabricated as per approved design), to be supplied alongwith mounting clamps-02 Nos,fabricated from (65mm x 5mm)MS providing 04 no Nut Bolt washer including dismantling taking down old unsv bracket of any type with clamps , nuts bolts etc complete all as per directed. Note : The Contractor should fix the clamp as per site requirment.
Supply & fix hot Press moulded junction box of size 400mmx300mmx 190mm hinged type including 04 No aluminium Bus Bar of suitable capacity with fixing arrangement like suitable size clamps, Nuts, bolts and washers etc and including SP MCB 6 Amps clamped with Pole complete all as specified and directed
Supply and fix 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmm for electrical connections to the street lights fittings complete all as specified and directed.
M& L for Cleaning, preparing and painting with one coat of aluminium paint to steel tubular pole 9 m long complete with cross arms, MS channels, angle iron, frame work, etc incl numbering of pole with black enameled paint from stencil complete all as specified and directed.
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed. Make CG cat part No S0DRVES-36-700-25W or equivalent make as specified in PS
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 72 to 100 W capacity complete all as specified and directed. Make CG cat part No X075C070V107FNY1BO or equivalent make as specified in PS
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed. Make CG cat part No X150C070V210FNI1BO or equivalent make as specified in PS
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed . Make CG cat part No SRPS-5K-440 or equivalent make as specified in PS
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking down existing MCB complete all as specified and directed.
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking down existing MCB complete all as specified and directed.
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking down existing MCB complete all as specified and directed.
Supply laying & testing of cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 3.5 core 35 Sqmm complete all as specified and directed.
All as per ser No 21above but 25 Sqmm 4 core
All as per ser No 21 above but 16 Sqmm 4 core
All as per ser No 21 above but 10 Sqmm 4 core
All as per ser No 21above but 16 Sqmm 2 core
All as per ser No 21 above but 10 Sqmm 4 core
All as per ser No 21 above but 06 Sqmm 2 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Laying only of old bricks covering with width equal to length of brick as mechanical protection to cables using old retrieved bricks from excavation complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete all as specified and directed
M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed
M&L for Service cable/wire 1100 Volt flat twin core aluminium solid conductor of size 4 Sqmm complete all as specified and directed.
M&L for Service cable/wire 1100 Volt flat twin core aluminium solid conductor of size 6 Sqmm complete all as specified and directed.
M&L for Service cable/wire 1100 Volt flat twin core aluminium soild conductor of size 10 Sqmm complete all as specified and directed.
M&L for Service cable/wire 1100 Volt flat twin core aluminium soild conductor of size 16 Sqmm complete all as specified and directed.
S&F in repair for fabrication and installation of feeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket and with MCB TPN 63 Amp for incoming and outgoing cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm long as per sample including taking down complete all as specified and as directed.
Supply and fix aluminium lugs of any type / shape of capacity from 10 Sqmm to 25 Sqmm complete all as specified and directed
Supply and fix aluminium lugs of any type / shape of capacity 35 Sqmm to 95 Sqmm complete all as specified and directed
Supply and fix aluminium lugs of any type / shape of capacity 120 Sqmm to 240 Sqmm complete all as specified and directed
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
Supply and laying or fixing or passing through pipe or fixing on wall with clamp 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sqmm 2 Core stranded conductor Complete all as specified and directed.
S&F in repair for fabrication and installation of feeder pillar box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket suitable for upto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm, 400 mm long as per sample including taking down complete all as specified and as directed.
Supply and laying GI Tubing Light grade 40 mm Bore dia as Cable Protection fixed on walls/ poles by using the suitable size clamps , nuts , bolts etc or laid in trenches complete all as specfied and directed.
Supply and laying GI Tubing Light grade 25 mm Bore dia as Cable Protection fixed on walls/ poles by using the suitable size clamps , nuts , bolts etc or laid in trenches complete all as specfied and directed.
Supply and fix 7 Mtr High hot dip Galvanized octagonal pole made up of 3 mm thick sheet along with Nuts and bolts brackets , suitable size base plate and 04 no of J type foundation bolts with template as suitable for pole complete all as specified and directed. Note : The Rate includes for Earthwork & PCC in foundation of pole shall be as per manufacturer design and recommendation
M&L for taking down by manual / motorised handle high mast light fittings at 15 to 20m height and refixing after necessary repairs including all necessary staging, etc. for cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: The quoted Rate is inclusive of taking down hig mast ligth & transportation to and fro from MES store/site to civil workshop & reinstalling at same or other location as directed .
M&L for repairing and rewinding of High mast motor of capacity upto 3 HP/2.4 KW of any make/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etc complete all as specified and directed. Note: The quoted Rate is inclusive of taking down hig mast ligth & transportation to and fro from MES store/site to civil workshop & reinstalling at same or other location as directed .
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer incl dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed.
Note: The work under subject BoQ (item No. 1.00 to 54.00 ) are meant for maint of Security light/street light in Nagrota Mil Stn ( Including Katra, Sanjhi Chat, Charli Hill ). The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply at Station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
M/S Shankardass Devidass
PAWAN KUMAR GOVT. CONTRACTORS
MAMTA ENTERPRISES
M/S A K ENGINEERS & CO.
slathia construction works
M/S ANMOL TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .