Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.4 LAccepted-AOC COLABA MUMBAI | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹74.8 L+₹6.8 L (9.93%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹84.5 L+₹16.5 L (24.3%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Not lowest | |
| 4 | Rejected-Technical 15 401 PREM JOT COMPLEX ANIKET CO OP HSG SOC LTD NEAR INDIAN OIL NAGAR GHATKOPAR MANKHURD LINK ROAD GOVANDI CHEMBUR W MUMBAI 400043 | MUMBAI | MUMBAI | MAHARASHTRA | 400043 | - | Rejected-Technical Not approved as not enlisted in appropriate category i.e. b(ii) |
Tender Value
₹76.4 L
EMD Value
₹1.4 L
Closing Date
23 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE (AF) GANDHINAGAR
CE (AF) GANDHINAGAR LEKAWADA PATIA CHILODA CAMPUS GANDHINAGAR
AUGMENTATION OF POWER SUPPLY AND ENHANCEMENT OF ELECTRIC SUPPLY LOAD AT AF STN KANHERI HILLS
2021_MES_460394_1
84192
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) THANE
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (AF) THANE
₹1.4 L
Yes
29 Sept 2021
16 Jul 2021
25 Aug 2021
16 Jul 2021
23 Aug 2021
11 Aug 2021
23 Jul 2021 - 30 Jul 2021
60 days
Amount
M& L for disconnecting HT 22 KV 95 sqmm 3 core cable carefully from transformer/VCB/Four Pole Stucture.
M&L Earthing with Copper Earth Plate Electrode 600x600x 3.15 mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to 20×3mm copper strip as earthing lead by means of Bolts, Nuts, Check, Nuts and Washers of GI protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable Earthing of any description, complete all as per specified and as directed.
M&L for Vacuum Circuit Breaker for HT 22 KV, Enclosure protection-IP4X, I/C entry-Through Rear Bottom, O/G Exit-Through Side Adaptor, Type / Model-VRK-36, testing after completion of the work complete all as specified and directed. System Details : 22 KV one incoming and one outgoing System Indoor type System Voltage : 22 KV Insulation Levels : 24 KVA Frequency : 50 Hz Current Rating : 630 Amps Short time rating : 26.3kA for 3 Sec. Applicable standard Paint shade : Grey as per shade RAL 7032 Busbar Material : (60mmx10mm copper) IEC 62271-2001 Busbar Rating : 630 Amps IS13118 & IEC 298/ IS-3427 Earthbus : 50 X 10mm Copper Indor type Auxiliary Voltage : 230V AC Control Voltage : 24VDC ( Through Power Pack ) Enclosure protection: IP4X, (incoming Entry - Through Rear Bottom) out Going : Through Side Adaptor, Vaccum Circuit Breaker - Horizontal isolation/ Horizontal Draw Out VCB fitted with Manual/ Motor Operated spring charging mechanism with 230V AC Motor, shunt trip coil of 24 V DC, Closing coil of 24 V DC, Aux contact 6 NO/ 6 NC, Mechanical ON/OFF indicator Operation countertesting after completion of the work complete all as specified and directed
Supply and fixing cable HT jointing kit for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 22 KV voltage line with 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as directed.
Supply and fixing cable HT jointing kit for out door termination heat shrink type joint complete with jointing material and accessories suitable for 22 KV voltage line with 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as directed.
Supply and fix Cable jointing kit for 22 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm.
Ring Main Unit 22 KV, 630 A, SF-6, having two incoming isolator and three outgoing breakers rated voltage 24 KV, insulation level 50 KV rated current 630 Amp, having rated short time current 21 KA for 3 second, short circuit breaking current 21 KA, Earth switch short time withstand current 21 KA , Ambient Temperature min 25°C max 50°C, Degree of protection IP67, SF6 Gas filling pressure at 20°C. Load Breaker Switch with following components : 630 Amps, Triple Pole, Single Break, 3 Position (ON, OFF, EARTH) Ring Main Switches, each with Independent manual mechanism and fully rated earth switch qty -2 , air insulated cable boxes with gland plate suitable for bottom entry of single run of 3 core cable qty -2 upto 300 sqmm qty-2, Set (3 Nos) of Cable busting qty-2, Live line Indicator LED Display qty -2, Mimic diagram on front Panel complete with status indicators(ON-OFF-EARTH) QTY-2, Fault passage indicator with remote contact -2, Set of right boots Non touch Proof-2 . VACUUM CIRCUT BRAKER (VCB) WITH FOLLOWING COMPONENTS . 630 Amps, 20 KA Triple Pole Vacuum Circuit Breaker with independent Manual Mechanism and fully rated earth switch with provision for earth cable for Earthing Each -3, Air insulated cable box with gland plate suitable for bottom entry of single run of three core suitable upto 300 sqmm Each -3, Over current & earth with digital displays & Auxiliary power supply Each-3, Set of current transformers for protection circuit mounted on cable bushing /Cable box of ratio 100-200/LA, 5P10, 2.5 VA\set of 3 Nos. -Each3 , Live line LED indicators LED display Each -3, Mimic diagram on front Panel complete with status indicators(ON OFF EARTH) Each -3, Epoxy mounded low energy tripping coil for tripping the circuit breaker in fault condition Each-3, Local 'Push to Trip' mechanism for emergency trip Each -3, Set of potential free contacts for for SCADA compatibility Each -3, Set of right angled Boots Non touch Proof Each -3
RMU 630 A should continuous rated copper bus bar Each 1, set positive standard mechanical interlocks to avoid unsafe operation Each -5, Provision for padlocking for open, close, Earth position in correct sequences Each -10, Manometer for including SF6 gas pressure with red and green zone Each -1, sets of hook stronger enough to take the load of entire unit while lifting by means of crane Each-04, SF6 tank of 3mm stainless steel robotically welded construction Each-1, External stud for earthing connection, SF-6 Gas charging Facility. dully constructed outer cladding constructed.
Taking out old unserviceable underground HT cable of any type from the ground, wall, floor complete all as specified and directed by Engr-in-charge. Note - Excavation and earth work will be mesured and paid seprately.
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 22000 volts, grade cross sectional area 95 sqmm 3 core all as directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of UG Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and in hard/ dense Soil and getting out, complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. (Soil)
Removing surplus excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed. (Soil)
Material and labour sand filling in trenches with clean dry unwashed sand for cushioning of under ground cable complete all as specified and as directed. Note : Punned thickness of sand will be measured.
Taking up reinforced precast concrete cable cover any class any type with any size complete all as specified and directed by Engr-in-charge.
Relaying reinforced precast concrete cable cover of any type complete all as specified and directed by Engr-in-charge.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1, with peak, size 450mm x 230mm x 50mm complete all as specified and directed.
Taking out old unserviceable GI Pipe 100 mm dia of any type from the ground, wall, floor complete all as specified and directed by Engr-in-charge. Note - Excavation and earth work will be mesured and paid seprately.
Supply and laying GI Pipe 100mm dia light grade including fittings using for cable protection at the crossing of canal/guard wall of the hill etc all as directed.
Material and labour for cross arms, bracing, supports, clamps and back plate fabricated from structural steel section including nut, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
M & L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate for fixing cable protection pipes all as directed.
S& F Cable route indicator for HT, 6mm thick CI plate of size 100 mm dia welded to MS angle iron 50x50x6mm embedded in PCC 1:3:6 type C-1 block size 150x150x 160 mm complete all as specified and as directed.
M&L BORING OF HOLES UNDER ROAD, PAVEMENT, TAXI WAY, HARD STANDING BY TRENCHLESS TECHNOLOGY USING ULTRA SOUND TECHNIQUE AND NECESSARY MACHINE INCLUDING LAYING OF GI PIPE OF 100MM DIA all as specified and directed.
Schedule of credit Rs 60485.00
Safe Construction Co.
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .