Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L1 | Accepted-Finance being L1 | |
| 2 | L2₹1.1 L+₹800 (0.74%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance L2 | |
| 3 | L3₹1.1 L+₹2,800 (2.61%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
Closing Date
6 Jan 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
36 LBS MARG
JOB WORKS
2020_MES_408584_1
3002/EM/JOB/99/E3
Limited
Job Works
Works
30 days
GE E/M Lucknow
As per NIT
2 documents required · 2 mandatory
₹0
Exempted
31 Mar 2021
1 Jan 2021
7 Jan 2021
1 Jan 2021
6 Jan 2021
1 Jan 2021
90 days
Job Work to be required to be carried out for Repair/replacement of 15 KVA DG Set Against BER at CMDC Training centre under GE E/M Lucknow
Installation testing and commissioning of 15 KVA DG Set complete all as specified including required arrangement water potter, Diesel, FOL, cable etc done by contractor, included in Quoted rate Note - 15 KVA DG set should be issued by department store yard
M&L for PCC platform/plinth with PCC 1:2:4 Type B2 with 40 mm graded aggregate, and required brick, cement, mortar etc for 01 feet depth below ground level and 01 feet on the above ground level of size 05 feetX08 Feet of suitable for fixing of for mounting of 15 KVA DG set complete all as specified
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polethylene (LXPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi standed, heavy duty 1100 volts grade of size 50 sqmm cross sectional ara, 3.5 core, complete all as specifed laid in trenches/laid under floor or fixed naked with walls/on poles/in ducts/in GI pipes etc. With and including MS Clamps, nuts, bots, washers complete all as specifed and directed
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. And getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, fillings in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specifed and directed.
Removing excavated material (soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specifed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed. Note:- Punned thickness shall only be considered for payment
M&L Laying well burnt old size bricks, sub class B bricks straight or curved on plan, laid flat with width equal to lenght of brick, laid dry over electric cable for protection all as specifed.
Boring/drilling (horizontally) manually under existing road (maximum 10 M in width) suitable for passing GI Tuing of 40 to 80 mm bore complete all as specified.
S&F GI tubing Light grade 40MM for cable protection fixed in poles/walls /laid under roads/crossing etc incl taking out rusted pipes of following sizes, complete all as specified and directed.
Earthing complete with galvanished iron earth plate 60cmX60CMX6mm thick electrode, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanished iron earth lead strip of size 32x6 mm up to test point by means of copper nuts, bolts, check nuts and washers of copper including excavation and earth work, PCC 1:3:6 type C-2 pit, GI Pipe, PCC pit cover 1:2:4 type B-1 with handle, 8 mm TMT bar 100c/c both ways. Funnel, wire mess etc complete as shown in electrical plate No. 5 of SSR part-I connected to earthing test point all as specified or including testing on completion.
Industrial Traders
M/S Sanjai Sales & Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .