Loading…
Loading…
Tender Value
₹6.5 Cr
EMD Value
₹13.1 L
Closing Date
9 Jul 2026, 3:30 pm
Similar tender results from the same govt authority in the past 3 years.
Ajmer Division: Provision of Dual VDU by replacing operating panel at 07 Nos. EI stations in (NANA-IQG) section under the jurisdiction of ADSTE/ABR in Ajmer division."
SNT-AII-21-2026-27
SNT-AII-21-2026-27
Open
180 Days
Ajmer, Rajasthan
₹0
₹13.1 L
12 Jun 2026
12 Jun 2026
25 Jun 2026
Description:- Supply of embedded fanless PC based VDU control terminal as per RDSO spec. No.
The size of VDU shall be minimum 42 inch. Note: (i) Technical requirements shall be mentioned in the tender document. (ii) One revolving chair should be supplied with control terminal. Inspection: Consignee Inspection charges: None Payment terms:100% after supply
Description:- Installation, wiring, testing and commissioning of embedded fanless PC based VDU
STS/E/TAN/3007 version 1 dated:02.11.12. Note: (i) Technical requirements shall be mentioned in the tender document by tendering authority. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning.
Description:- Supply of embedded fanless PC based Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12.
the tender document by tendering authority. (ii) One table of suitable size along with revolving chair should be supplied with Maintenance terminal. Inspection: Consignee Inspection charges: None Payment terms:100% after supply
Description:- Installation, wiring, testing and commissioning of embedded fanless PC based
STS/E/TAN/3007 version 1 dated:02.11.12. Note: (i) Technical requirements shall be mentioned in the tender document. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning.
AJMER DIVISION-S AND T/NORTH WESTERN RLY Description:- Supply of Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose pliers etc. & measuring
repair at site). Each set comprises of the following :- * Crimping tool for all types of special cable assembly used in EI system. * Insertion tool for all types of special cable assembly used in EI system. *Removal tool for all types of special cable assembly used in EI system. * Digital multi-meter (Fluke
(Godrej Make/Jalaram) of good quality to store tool, spare cards and documents. * Steel Book rack Size: 1850mm height, 900 mm width and 316 mm depth for keeping documents. (Godrej Make/Jalaram) * Clamp Earth Tester. (as per specs mentioned in tender document.) * Clamp Current Meter (fluke 362 or superior) * Ferrule tagging printer for cable/wires (Supported label tape sizes: 6 /
Description:- Preparation of SWR literature in English along with associated mid-section interlocked gate with all corrections as per approved SWRD & approved SIP. For these all-technical corrections,
for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.
Description:- Translation of Station Working Rules from English to Hindi and framing out in DIGLOT
the contractor and has been covered separately in item no. 01011800 of Chapter 1 of SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.
per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.
Description:- Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the
locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.
Description:- Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spee. No. IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This
racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases (G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.
Description:- Supply & Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos.
back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. (This item is for Operating VDUs of EI system) Inspecting Agency : (i)for inverters and converters : RDSO (ii) for other items : Consignee Inspection Charges: (i) Borne by Railways (ii) None For Supply of Modular power supply arrangement. Payment Terms: 100% after Supply
AJMER DIVISION-S AND T/NORTH WESTERN RLY Description:- Supply & Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos.
back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. (This item is for Operating VDUs of EI system) Inspecting Agency : (i)for inverters and converters : RDSO (ii) for other items : Consignee Inspection Charges: (i) Borne by Railways (ii) None For Installation of Modular power supply arrangement. Payment Terms: 100% after Commissioning
Description:- Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board
Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDE". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board
Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDF". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Twin Neutral Line Relay (QNN1 Type), 6F/2B, 24V DC complete with plug
Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACDEK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Twin Neutral Line Relay (QNN1 Type), 4F/4B, 24V DC complete with plug
Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACEHJ". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC
and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDEG". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24V DC along with plug
Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24V DC along with plug
Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDFH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
Description:- Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible
soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel troughing work. The work shall be done as per approved plan, extant practice on NWR & the instruction of Rly. Engineer at site. Inspection: - Consignee Inspection charges: - None Payment Terms: - 100% after execution
Inspection charges: - Borne by Railways Payment Terms: - 100% after supply.
22 AJMER DIVISION-S AND T/NORTH WESTERN RLY
(0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
Description:- Supply of indoor PVC jumper wire (1x 0.6 mm) of all colours as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Note: wires colours will be specified/decided by site
Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
Description:- Supply of PVC insulated Railway Signalling multi-core Indoor Cable 24 core (1 mm
more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
suitable for 3.3KV to 11KV (Class B) conforming to IS I5652-2006 Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply.
Description:- Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. SDO/ RDSO/E&B/001. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17 mm Dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of
Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply
Description:- Installation of Unit Maintenance Free Earth as supplied under item no. 13010300 above It includes: ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm Dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper
writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. S DO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution and testing.
Description:- Supply of Professional AC/DC clamp meter 3 ¾ digit, true RMS measurement, For Measurement of DC/AC currents up to 60A, AC/DC Voltage up to 600V, resistance up to 40 M, Current
measurement function with set of leads & carrying case. Model - SCM222 or equivalent/ higher make. Motwane/Stanlay/Fluke/Megger Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply.
29 AJMER DIVISION-S AND T/NORTH WESTERN RLY
measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 - 49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement Model - DECT-2 or CET500 or equivalent / higher version make Motwane/Stanlay/Fluke/Megger. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply.
Description:- Standard Tool kit for signal maintenance (suitable for RE area working) with following items (with small size canvas log) (i) Insulated combination plier of 8" = 1no. (ii) Insulated long nose plier of (road wise) 6" =1 no. ( iii) Insulated wise stroper plier of 6"=1 no ( iv) Insulated screw driver
spanner set (6 to 32mm) = 1 set (viii) Adjustable spanner set 8" =1 no (ix) Ball pin hammer 200 gm =1 no (x)Soldering iron 25 watt =1 no ( xi)Torch cell LED (3 cell) Eveready/jeep = 1no (xii) Auto ranging digital multi-meter (Branded) =1 no (xiii) Crow bar steel/ tommy bar =1 no Inspection: Consignee Inspection charges: None Payment terms: 100% after supply
per RDSO Drg. No. SDO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection charges: Borne by Railways Payment terms: 70% after supply, 20% after installation & 10% after commissioning
approved by the site engineer incharge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply. S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () B-NS ITEMS 54667567.01 B 6.00 Numbers 210040.00 1260240.00 AT Par 1260240.00
MLKII Vital Input PCB 24VDC at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 6.00 Numbers 198240.00 1189440.00 AT Par 1189440.00
MLKII Vital Output PCB 24VDC at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning.. B 12.00 Numbers 14160.00 169920.00 AT Par 169920.00
Address Select PCB - 48 Pin at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 12.00 Numbers 2006.00 24072.00 AT Par 24072.00
48-Pin connector housing assembly at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 12.00 Numbers 1062.00 12744.00 AT Par 12744.00
48-Pin connector guide element at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 12.00 Numbers 1121.00 13452.00 AT Par 13452.00
48-Pin female connector at KVJ,PDWA & BNS Stations.Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 300.00 Numbers 64.90 19470.00 AT Par 19470.00
48-Pin female crimp contact at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 18.00 Numbers 25960.00 467280.00 AT Par 467280.00
Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1272040.0 B 3.00 Lot 3816120.00 AT Par 3816120.00 0
BNS Stations.Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 3.00 Lot 389400.00 1168200.00 AT Par 1168200.00 AJMER DIVISION-S AND T/NORTH WESTERN RLY
& BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1012440.0 B 3.00 Numbers 3037320.00 AT Par 3037320.00 0
Monitor at KVJ,PDWA & BNS Stations.Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1103300.0 B 6.00 Numbers 6619800.00 AT Par 6619800.00 0
Monitor at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 45.00 Numbers 46728.00 2102760.00 AT Par 2102760.00
Isolator Supply at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 6.00 Numbers 194700.00 1168200.00 AT Par 1168200.00
cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1362900.0 B 3.00 Numbers 4088700.00 AT Par 4088700.00 0
KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1362900.0 B 3.00 Numbers 4088700.00 AT Par 4088700.00 0
KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning.. 1233100.0 B 3.00 Station 3699300.00 AT Par 3699300.00 0
terminals & installation of few wires, connectors & terminals on account of aforesaid / proposed changes as per approved Signalling Plan at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 3.00 Set 285560.00 856680.00 AT Par 856680.00
Circuit & Interface Circuit in A3 size only) at KVJ,PDWA & BNS Stations. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. 1653975.0 B 1.00 Station 1653975.00 AT Par 1653975.00 0 Description:- Alterations to existing Interface circuits & Application Logic circuits of Medha make EI at Swarupganj (SRPJ) as per the approved circuit diagram. The scope of work includes (i) Redesign of EI Systems with related application logic & interface circuit. (ii) FAT & SAT and commissioning of the station as per modified Logic circuits. (iii)Installation of Modified Program & proposed changes as per approved Signaling Plan. (iv)Supply of Document(It shall be supplied in CD with one set of Application Logic Circuit & Interface Circuit in A3 size only). (v) This includes all material like Various
DC- DC converters, fixtures and accessories etc. required for commission of DUALVDU arrangement. The entire EI system shall be checked for any deficiencies. Necessary peripherals required for loading the logic shall be arranged by the contractor. This wiring of new relays & alteration to existing relays in EI relay rack also included in this scope of work. Wiring of additional inputs of relays from relay rack to EI system shall be done as per the approved Logic Circuits. wiring of additional digital/analogue inputs to existing data logger and validation/upgradation of Data logger database, shall also be done by the contractor. It includes the submission of TSAA & Supply of Alteration ''As made ''documents. Inspection:- RDSO for cards . Execution and other ancillary material - Consignee. Payment Terms:100% after commissioning. B 3.00 Station 650000.00 1950000.00 AT Par 1950000.00
VDU logic at NANA,BMN & IQG stations. B 3.00 Station 500000.00 1500000.00 AT Par 1500000.00
stations. AJMER DIVISION-S AND T/NORTH WESTERN RLY B 3.00 Station 400000.00 1200000.00 AT Par 1200000.00 22 Description:- Activity of FAT at NANA,BMN & IQG stations. B 3.00 Station 300000.00 900000.00 AT Par 900000.00 23 Description:- Activity of SAT at NANA,BMN & IQG stations. B 3.00 Station 90000.00 270000.00 AT Par 270000.00
Operation i.e. Vital Parallel Input Module 50V (12 inputs) at NANA,BMN & IQG stations. B 6.00 Numbers 229100.00 1374600.00 AT Par 1374600.00
Operation i.e.Vital Relay Output Module 50V (8 outputs) at NANA,BMN & IQG stations. B 9.00 Numbers 750000.00 6750000.00 AT Par 6750000.00
Operation i.e.Supply of Control Terminal with Dual Industrial Grade PC and 55" Monitor at NANA,BMN & IQG stations. B 6.00 Numbers 42400.00 254400.00 AT Par 254400.00
Operation i.e.Supply of DC-DC Converters at NANA,BMN & IQG stations. B 12.00 Numbers 13200.00 158400.00 AT Par 158400.00
Operation i.e.Supply of Surge Arrestors at NANA,BMN & IQG stations. B 3.00 Numbers 31900.00 95700.00 AT Par 95700.00
Operation i.e.External SM key box at NANA,BMN & IQG stations. B 3.00 Numbers 70000.00 210000.00 AT Par 210000.00
Operation i.e. Supply of Wiring materials at NANA,BMN & IQG stations. B 12.00 Numbers 250000.00 3000000.00 AT Par 3000000.00
Operation i.e. Communication Equipment-Network Switch at NANA,BMN & IQG stations. B 7.00 Set 7405.43 51838.01 AT Par 51838.01 Description:- Releasing of existing SM's control panel including base plank and other gadgets
neatly at a place as instructed by railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, leveled and cement plastered.Inspection-consignee. B 26.00 Numbers 4956.00 128856.00 AT Par 128856.00 Description:- Supply of Relay AC Immune Plug in type style QNNA1 DC Twin DC Neutral line 24-volt
and connector confirming to BRS 960, IRS:S@58"44@ S:60 and IRS S-23. The interlocking code for this unit shall be CDEHX.Inspection: - RDSO
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
SNT-AII-21-2026-27DUALVDUNANA-IQG.pdf
ATTACHMENT
Download all tender documents and submit your bid