Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC BIRD LINE CALICUT POST SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC Being the lowest Tenderer | |
| 2 | L2₹25.8 L+₹2.2 L (9.46%)Rejected-AOC | L2 | Rejected-AOC Not Being the lowest Tenderer | |
| 3 | L3₹26.7 L+₹3.2 L (13.6%)Rejected-AOC | L3 | Rejected-AOC Not Being the lowest Tenderer | |
| 4 | L4₹28.0 L+₹4.5 L (19.0%)Rejected-AOC 79 MAHATMA GANDHI MARKET SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-AOC Not Being the lowest Tenderer |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
1 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer
Commander Works Engineer Military Engineer Services Junlighat Post Minniebay Port Blair 744103
80977 Spl Rep Replacement of old vintage type ACBs GE Minniebay
2022_MES_513636_3
80977 Spl Rep old Vintage type ACBs GE Minniebay
Open Tender
Civil Works - Others
Item Rate
180 days
Port Blair
Class E Category b ii
7 documents required · 7 mandatory
₹500
GE Minniebay
₹42,000
Yes
28 Jul 2022
10 Jun 2022
7 Jul 2022
10 Jun 2022
1 Jul 2022
17 Jun 2022
Amount
M& L for preparation to internal and external old steel surface of LT Feeder Piller Box/ Panel Boards of various size and completely removal of existing treatment by scrapping of chemical and surface painted with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M& L for repair of LT Feeder Piller Box/ Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing warn out shutter frame and fixed with minimum two hinges to existing frame complete all as specified and directed.
Taking down of PCC any grade complete all as specified and as directed by Engineer-in-Charge.
M&L cement concrete in foundations filling and mass concrete of B1 grade with using 20 mm aggregate (1:2:4) complete all as directed.
Material and labour PCC (1:3:6) type C-2 (using 40 mm graded broken stone aggregate) as in coping/collar of poles including necessary form work complete all as specified
Taking down of Old ACBs of any size and deposited to MES Store Yard complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Air Circuit Breaker should have 4-Poles, Manually Operated Horizontally Draw out Type (MDO), rated under Voltage, O/L, S/C, E/F and reverse power protection up to 1600 A operating at 415 V and having a Breaking Capacity of 50 kA for 1sec (143kA peak) and Service Breaking Capacity of the breaker should be 100% of the Ultimate Breaking Capacity and Short Time Withstand Capacity (i.e. Icu = Ics = Icw for 1sec= 100%). The ACB breaking capacity performance certificate shall be submitted for category B according to IEC 60947-2. Mechanical Life Cycle should not be less than 25000 cycles from 800A to 1600A. There shall not be any derating up to 45°C ambient. ACB shall be rated for operational voltage Ue up to 690V, Insulation voltage Ui:1000V and impulse withstand voltage Uimp of 12KV. ACB shall be fully tropicalized as standard with including necesarry fabrication at site if required for fixing of ACBs complete all as directed by Engr -in Charge. Make: Legrand / L&T / Siemens / Schneider/ABB/Indoasian/ C&S.
Supply and fixing Air Circuit Breaker should have 4-Poles, Manuallly Operated Horizontally Draw out Type (MDO), rated under Voltage, O/L, S/C, E/F and reverse power protection up to 1250 A operating at 415 V and having a Breaking Capacity of 50 kA for 1sec (143kA peak) and Service Breaking Capacity of the breaker should be 100% of the Ultimate Breaking Capacity and Short Time Withstand Capacity (i.e. Icu = Ics = Icw for 1sec= 100%). The ACB breaking capacity performance certificate shall be submitted for category B according to IEC 60947-2. Mechanical Life Cycle should not be less than 25000 cycles from 800A to 1250 A. There shall not be any derating up to 45°C ambient. ACB shall be rated for operational voltage Ue up to 690V, Insulation voltage Ui:1000V and impulse withstand voltage Uimp of 12KV. ACB shall be fully tropicalized as standard with including necesarry fabrication at site if required for fixing of ACBs complete all as directed by Engr -in Charge. Make: Legrand / L&T / Siemens / Schneider
Taking Down of Old aluminium Cable Lugs complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair for aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed by Engineer-in-Charge for the following sizes of cables complete all as specified and directed :-
(i) 185Sqmm
(ii) 240Sqmm
(iii) 300Sqmm
Aux Contractor - 12 Nos Aux Relay 24V DC Coil - 12 Nos Power Contactor 18A 230 AC Coil - 02 Nos DC Voltmeter - 02 Nos DC Ammeter - 02 Nos 6W Annunciator - 02 Nos EMG Push button - 02 Nos Push button - 10 Nos Hooter - 02 Nos Battery Charger - 02 Nos 6A SP MCB - 12 Nos 10A DP MCB - 06 Nos OUTGOING:- Out put Through Bus Bar Digital Voltmeter - 01 No Digital Ammeter - 01 No CT 1250/5A, CL-1 set of thee - 01 No Phase indicator lamp R/Y/B Set of three - 01 No complete all as specified and directed by Engineer in Charge. Note : 02 Nos of 1250 Amps ACBs are paid and Measured seperately vide item no. 08 above.
Taking down of Old RMU of any size and deposited to MES Store Yard complete all as specified and as directed by Engineer-in-Charge.
Supply, erect, test and commissioning of Indoor type (IP54) fully factory built metal enclosed Ring main unit (4way) as per IEC 62271-100/102/200 SF6 filled in hermitically sealed, gas tight, welded stainless steel tank with degree of protection IP67, Extensible type, manual spring charging , capacitive Voltage presence indicator, Operating mechanisms with integral mechanical interlocking and switch position indication, manometer for SF6 pressure monitoring with following incomer and outgoing:- Incomer 1: VCB, 11 KV, 630 A, STC 21 KA for 3 Sec, Rated power frequency withstand voltage of 28kV, rated lighting impulse withstand voltage 75kVp with self-powered numerical protection relay for Short circuit, Over current and Earth fault . Make C&S type CSPR-V5 or equivalent, Low energy release series trip coil for VCB tripping circuit, Low voltage ring type CT : 50/1A, Class 5P10 , 2.5VA for each phase ,Make Narayan Power tech/Reco/Gemini, Shunt Trip circuit for external trip signal etc.
Incomer 2: VCB, 11 KV, upto 630 A, STC 21 KA for 3 Sec, Rated power frequency withstand voltage of 28kV, rated lighting impulse withstand voltage 75kVp with self-powered numerical protection relay for Short circuit, Over current and Earth fault . Make C&SS type CSPR-V5 or equivalent, Low energy release series trip coil for VCB tripping circuit, Low voltage ring type CT : 50/1A, Class 5P10 , 2.5VA for each phase, Make Narayan Power tech/Reco/Gemini, Shunt Trip circuit for external trip signal etc Outgoing 1: Load Break Switch, 11 KV, upto 630 A, STC 21 KA for 3 Sec,, Rated power frequency withstand voltage of 28kV, rated lighting impulse withstand voltage 75kVp power frequency withstand voltage of 28kV, rated lighting impulse withstand voltage 75kVp. Outgoing 2: Load Break Switch, 11 KV, 630 A, STC 21 KA for 3 Sec,, Rated power frequency withstand voltage of 28kV, rated lighting impulse withstand voltage 75kV.
Dismantling / Taking down of GI Chequre sheet complete all as specified and as directed by Engineer-in -charge.
S&F Plates (plain or chequered) of 4mm thickness including channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment as indicated or directed and inclusive of complete all as specified and as directed by Engineer-in -charge.
Dismantling / Taking down of old unserviceable earthing complete all as specified and as directed by Engineer-in -charge.
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete all as specified and as directed by Engineer-in -charge. NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL (ii) If the desired earth resistance is not acheive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
Taking down of unserviceable GI earthing strip any size complete all as specified and as directed by Engineer-in -charge.
Supply and fixing in repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed by Engineer-in -charge.
Taking Down of Old unserviceable Bus Bar of any size complete all as specified and directed by Engineer-in -charge.
Supply and fixing of Aluminium Bus Bar of existing Size in the existing panel board on site on required shape post insulators, complete all as specified and as directed by Engineer-in -charge. Make .Hindalco.
Supply and fixing in repair LED Indicating lamp (Red-Yellow-Blue) complete all as specified and as directed by Engineer-in -charge.
C KUMAR
OPS Associates
Gulmarg Electrical Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .