Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹49.5 L+₹3.7 L (8.02%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹52.9 L+₹7.1 L (15.4%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹54.0 L+₹8.2 L (17.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹57.4 L+₹11.5 L (25.0%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
25 Mar 2024, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
ADDITION/ ALTERATION AND SPECIAL REPAIR TO CIVIL AND ELECTRICAL WORKS FOR 08 ORs MARRIED ACCN (BUILDING NO.P-10) AT DSC COMPLEX, DRDL, KANCHANBAGH, HYDERABAD
2024_MES_645572_1
8733/E8
Open Tender
Civil Works
Item Rate
240 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹96,400
Yes
18 Apr 2024
7 Mar 2024
27 Mar 2024
7 Mar 2024
25 Mar 2024
19 Mar 2024
8 Mar 2024 - 15 Mar 2024
Amount
Demolition of brick work in cement mortar manually / by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of Engr -in- Charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing cement concrete manually / by mechanical means including disposal of materials within 50 metres as per direction of Engr -in- Charge.
Dismantling tiles work in floors and roof laid in cement mortar including stacking materials within 50 metres lead. (i) for thickness of tiles 8mm to 25mm
Taking out doors, windows and clerestory window shutters ( steel or wood) including stacking within 50 metres lead :- of area 3 Sqm and below
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Taking down existing roof treatment of any position with bituminous felt including plaster / loose concrete and removing rubbish to a distance exceeding 100 mtr and not exc 250 mtrs and roughing the surface of old concrete by picking, scraping, cleaning and washing down with water to remove all dust etc all as specified and directed.
M&L for 40mm thick grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) complete all as specified.
M&L for rendering 10mm in CM 1:3 over concrete surfaces on RCC roof slab and parapets mixed with WPC @ 3% by weight of cement shall be carried out complete all as specified and directed by Engr-in-Charge. Note : WPC will be measured under separate item of this schedule.
Supply only integral water proofing compound. Make :- SCOTT AQUA PROF/RAILIA
Providing and carry out water proofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar , curing compound etc carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100 plasticised expandive ground admixture supplies in 225 gm pouch,treatment of construction joints using polymer modified mortar prepare by using Nitobond SBR latest's, application of polymer modified batter at floor, wall junction, filling of annular space around rain water outlet using contexture GP2 non shrink cementitious grouts. Undulated surface and pot hole shall be treated with epoxy mortar or putty to obtained sound/ leveled surface. Application of primer Into proof WB primer on sound mortar slab surface. Followed by application of coat of Into proof 600 PF liquid applied single component pitch free polyurethane coating supplied in 25 kg drum coverage @ 2.30 Kg/ m2 to achieve 1.5mm thickness in two coats complete including all tools and tackles as per manufacturers specification. Coating shall be having crack bridging of 2mm, elongation ( ASTMD 124 ) greater than 600 percentage, tensile strength ( ASTM D412) , 2.5 N/MM2 , recovery from elongation ( ASTM D412) , 95 percentage, 85 percentage of solid continents, tear resistance ( ASTM D624) , 15 KN/M, shore A hardness ( ASTM D2240) , 60, water vapors transmission not more than 1 gm / M2 ,water permeability ( DIN -1048) - NIL, services temperature - 40'c to 70 degree 'c , flash point greater than 70'C HSE guidelines :- It is recommended to provide adequate general and local exhaust ventilations, providing protection to Eye, face, Hand and other skin by wearing appropriate grouse, Google, face cilid, respiratory protectionists. directed in SDS of the product. Note:- Work shall be carried out through authorised agent of manufacturer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling CP brass/ stainless steel screws, all complete as per architectural drawings and the directions of engr -in- Charge. (Glazing, paneling and dash fasteners to be paid for separately) :- (i) For fixed portion powder coated aluminium ( minimum thickness of powder coating 50 micron)
Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing windows frame with CP brass / stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per direction of Engr -in- Charge
Proving and fixing glazing in aluminium door, window, ventilator shutters and partitions etc with EPDM rubber / neoprene gasket etc complete as per the architectural drawings and the directions of Engineer-in-charge:- With float glass panes of 5mm thickness ( weight not less than 12.50 Kg/ Sqm)
supply and fix fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching to aluminium window.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of frame size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat of frame size frame size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (woodpowder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 35 mm thick, of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. Note: stainless steel butt hinges and necessary S.S screws shall be paid separately.
Providing and fixing wire gauge shutters using galvanised MS wire gauge of average width of aperature 1.4mm in both directions with wire of dia 0.63mm, for doors , windows and clerestory windows with hinges and necessary screws, 35mm thick shutter withISI marked MS pressed butt hinges bright finished of required size Kiln seasoned and chemically treated hollock wood.
Providing and fixing ISI marked MS pressed butt hinges 100 x 58 x 1.90mm bright finished with necessary screws etc complete.
Providing and fixing IS : 12817 marked stainless steel butt hinges of size 75x47x1.80 mm with stainless steel screws etc. complete :
Providing and fixing aluminium handles 125mm , ISI marked , anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc complete.
Providing and fixing aluminium tower bolts 150 x 10mm, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc complete.
Providing and fixing aluminium sliding door bolts 300 x 16mm , ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nut and screws etc complete.
Providing and fixing aluminium Twin rubber stopper hanging floor door stopper, ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade , with necessary screws complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
M&L Painting to steel surface with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade one or more coats of old surfaces complete.
Providing and fixing factory made door frame ( single rebate ) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62mm width & 32mm thickness , frame will be mitred & jointed with self driven self tapping screws of size 38mm x 4mm & PVC solvent cement including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer -in- Charge.
Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm, painted with primer, all four corners of reinforcement to be welded or sealed. solid PVC extruded bidding ( push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer -in- Charge.Decorative finish ( both side wood grained finish).
M&L 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
M&L 6mm thick cement plaster 1:3 ( 1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams.
M&L for Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing.
Finishing wall New work (Exterior emuslion two or more coats applied @ 1.43 liter/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 liter / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ liter and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives.
Distempring Two or more coats on new work over a coat wall primer with Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / liter of approved brand and manufacture of required shade and colour including applying 1mm thick wall care putty complete as per manufacturer's specification.
White washing on new work of ceiling surfaces (three or more coats) to give an even shade complete.
Providing and laying Double charge vitrified tiles size 600 x 600mm in floor in different size ( thickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved brand & manufacturer, in all colors and shade , laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily.
Providing and laying vitrified tiles in different sizes ( size of tiles 600 x 600 mm) ( thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colors & shade , in skirting, riser of steps , over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete.
Providing and fixing Its quality ceramic glazed wall tiles conforming to IS : 15622 ( thickness to be specified by the manufacturer) of approved make, in all colors, shades except burgundy, bottle green, black of and size as approved by Engr -in- charge , in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 ( 1 cement ; 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying ceramic glazed floor tiles of size 300 x 300 mm or more ( thickness to be specified by the manufacturer) of !st quality conforming to IS : 15622 of approved make in colors and shade except white ivory, Grey, fume Red Brown, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including pointing the joints with white cement and matching pigment etc complete.
Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete.
Disconnecting damaged over head / terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engr -in- Charge.
Providing and placing on terrace ( at all floor levels) polyethylene water storage tank, 1000 ltr capacity IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing ball valve 20 mm nominal bore(brass) of approved quality, High or low pressure, with plastic floats complete.
Providing Half brick masonry with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in super structure above plinth level up to floor V level in cement mortar 1:4 as per direction of Engineering-Charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 15 mm nominal dia , having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc and dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineering-Charge and Concealed work, including cutting chases and making good the walls etc.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 20 mm nominal dia , having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. Exposed on wall ,This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge and Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineering-Charge and all as specified.
Providing and fixing in repair gun metal gate valve 20mm nominal bore with CI wheel of approved quality ( screwed end) complete all as specified.
Dismantling CI or asbestos rain water pipe with fittings and clamps including stacking the materials within 50 metres lead :- (i) 100mm dia pipe
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type 'A' including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion single socketed pipes :- (ii) 110 mm diameter
Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type 'A' including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion :- (ii) Bend 110mm dia
All as per item No.50 above but Coupler 110mm dia
Providing and fixing PTMT ball cock of approved quality , colour and make complete with Epoxy coated aluminium rod with LP / HP HD plastic ball :- (i) 20mm nominal bore 120mm long , weighing not less than 198 gms
Providing and fixing C.P. brass stop cock (concealed) of 15 mm nominal bore, standard design and of approved make conforming to IS:8931,
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameter
Providing and laying cement concrete in retaining walls, return walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, sunken floors etc up to floor five level excluding the cost of centering shuttering and finishing :- (i) 1:2:4 (1 cement : 2 coarse sand ( zone -III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources )
Providing and fixing steel E165 (Fe 290) confirming to IS 2062 -2006 work in gratings, frames, guard bars, ladders, railing, brackets, purlings, gates and similar works welded in built up sections / frames work, including cutting, hoisting, fixing in position and applying priming coat of approved steel primer using structural steel as required
Steel reinforcement for RCC work ready to use "cut and bend" and welding rebars of approved make from factory / workshop to construction site including placing in position and binding all complete above plinth level up to 3rd floor roof slab projection and welding where is necessary. (i) Thermo / Mechanically Treated bars of grade Fe- 500D or more
M&L for followings :- (i) Removing plaster, loose concrete & finishes all around the columns, slabs & beams (on all four sidescription of column to full height , three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Removing visible rust along the length of reinforcement using hand tools as approved. (The Engr-in-charge may order sand blasting if rust is approved) (v) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed.
M&L for Providing & Pouring Micro concreting M-40 grade :- Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : Master Emaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labor charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed. Note : The cost of micro concrete M-40 grade & Epoxy bond coat is included in this item.
M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) around (ii) Apply a single coat of Alkaline rust converting primer on around bars new & old as recommended by the manufacture (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars around new & old as recommended by the manufacture. Note : Anti corrosive treatment shall be continuous especially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairly rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacture complete all as specified and directed.
Making the opening in brick masonry for door/ window/ clerestory ventilator for exhaust fan window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba / rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer -in-Charge
Distempering on old work ( wall/ ceiling) ( one or more coats) with 1st quality acrylic distemper ( Ready mix ) having VOC content less than 50 grams/ liter of approved brand over a coat of water thinkable cement primer and manufacturer to give an even shade
Painting on new steel surface ( two or more coats ) including a coat of approved steel primer ( red oxide primer) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade
M&L for preparation of surfaces of cracks in walls and ceilings land filling smart crack filler to any depth while surfaces are dry and sealing cracks completely and flushing with existing surfaces all as per manufacturers instruction. Make : Asian Paints smart cracks filler or equivalent in Dr fixit
Providing and fixing 75mm dia sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors
Providing and fixing square mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber with water tight C.I cover with frame of 300 x 300 mm size ( inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :- (i) 150 x 100 mm size P type with common burnt clay F.P.S ( non modular) bricks of class designation 7.5
Providing and fixing in repairs wash basin with CI brackets, 15mm CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :- (i) White vitreous china flat back wash basin size 550 x 400mm with single 15mm CP brass pillar tap
Providing and fixing PVC waste pipe flexible pipe 32mm / 40mm dia for sink or wash basin and urinal including PVC waste fittings complete
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass ( of approved quality0 complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete
Providing and fixing in repairs CP brass long nose bib cock 15mm nominal bore of approved quality conforming to IS standards and weighing not less 410 gms
Providing and fixing in repairs CP brass angle valves 15mm nominal bore for basin, mixed, geyser, urinal etc points of approved quality conforming to IS 8931
Providing and fixing plasticized PVC connection 15mm nominal bore x 45 cm length pipe with PTMT nuts, collar and bush of approved and colour
Excavation work by mechanical means ( Hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m :- (i) Ordinary rock
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms in bathroom all complete.
Providing and laying cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing,
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Its course of applying cement slurry @ 4.4 kg/Sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound 3% of weight of cement in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per Sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/Sqm).
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approved quality and colour 600mm long
Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer -in- charge beyond 50m initial lead for all leads including all lifts involved.
Returning filling in trenches incl spreading, levelling , watering& well ramming in layers n.exc 25 CM thick
Providing and fixing in repair Stainless Steel A ISI 304 (18/8) kitchen sink, Kitchen sink with drain board, 510x1040 mm bowl depth 250 mm , as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required , waste pipe and making good disturbed portion in CM 1:3 or PCC 1:2:4 as directed by Engineer-in-Charge.
Providing and fixing in repair water closet squatting pan ( Indian type WC pan) with 100mm sand cast iron P or S trap, 10 liter low level white PVC flushing cistern including flush pipe, with manually controlled device ( handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :- (i) white vitreous china Orissa pattern WC, pan of size 580 x 440 mm with integral type foot rests
Making plinth protection 75mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mm nominal size derived from natural sources) of 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand , including necessary excavation, levelling & dressing & finishing the top smooth.
S&F Stainless steel plate rack of size 910x 750x 300mm complete all as specified and directed. (Cat No : P-348 of Prayag or equivalent in Diamond / Nirali
Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked, including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia ( heavy type) curtain rod with nickel plated brackets, including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100 mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. all complete.
Providing and fixing to 125 mm grating with waste hole
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : (a) 75 to 110 mm dia pipe
Providing and fixing on wall face unplasticised Rigid PVC 75/110 mm diameter water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
Providing and fixing Coupler 75 mm
Providing and fixing Single tee with door 75x75x75 mm
Providing and fixing Bend 87.5° of 75 mm bend each
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete .
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete and Distempering with 1st quality acrylic distemper (Ready mix) having VOC content less than 50 grams/ liter of approved brand and manufacture to give an even shade : Old work (two coats) complete as per manufacturer's specification
White washing on old surface and removing of old white wash on ceiling surfaces Old work (two or more coats) Sqm to give an even shade complete
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design: (i) Inside size 90 x 80 cm and 45 cm deep including C.I cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): (a) With F.P.S. bricks with class designation 75.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diameter S.W. pipe
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Point wiring with 1.5 Sq.mmm copper conductor FRLS (multistranded) PVC insulated ISI marked unsheathed cable of any length drawn in and including concealed non metallic rigid PVC conduit of not less than 25mm dia ISI marked with all fitting and other accessories and also including PVC insulated ISI marked unsheathed FRLS cable size 1.5 sqmm copper conductor as earth wire to common earth dolly including galvanised terminal boxes ISI marked fixing into the wall of sizes as required at site and modular plates and frame suitable for fixing switches / sockets / fan regulators etc, and making good the disturbed surfaces matching to the existing surface for one light point/fan point/bell point controlled by one way modular switch 5 Amps 240 volts, complete all as specified and directed
One 3 pin 5 Amps switch socket outlet point on independent board
One light point controlled by two way 5 Amps switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per SI Item No. 100 here-in-before but wiring with 4 Sqmm for 15 Amps modular 3 pin socket outlet on independent board / two pin earth plug and socket including providing 4 Sq.mm PVC insulated multistranded unsheathed FRLS copper earth continuity conductor and connected to common earth dolly, complete all as specified and directed.
Supply & Fixing Modular switch, one module, one way 6 Amp, 240V, complete all as specified and directed.
Supply & Fixing Modular switch 16A, one way, one module, 240 Volts, complete all as specified and directed.
S&F modular switch two way 6 amps 1 module ,240V,50 Hz,complete all as specified and directed.
Supply & Fixing Modular step type, electronic fan regulator, two module, 240 Volts, complete all as specified and directed.
Supply & Fixing modular socket one way 6 Amps, 2/3 pin combination 2 module, complete all as specified and directed.
Supply & Fixing modular socket, 6A/16A - 2 /3 pin combination 2 module, complete all as specified and directed.
S&F Modular Bell push 5 Amps one module,230V,50 Hz complete.
Supplying and fixing brass batten/ angle holder including connection etc. as required
S&F ceiling rose two to three terminal surface backallite type AC 50Hz 230 volts complete
M&L for bell electric AC. 230 V fish type, calling bell including taking down old unserviceable one complete
S&F 1x20W,230V, 6500K CCT surface mounted integral LED batten with extruded aluminium housing with inbuilt electronic driver, polycarbonate diffuser including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting all as specified. Make : Havells cat part No. ENDURALINEARNEOBS20WLED865SPCSS or equivalent in Philips/Wipro/Polycab/Shakti
S&F 1x10W,230V, 6500K CCT surface and wall mounted integral LED batten extruded aluminium housing with inbuilt electronic driver and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting all as specified. Make : Havells cat part No. ENDURALINEARNEOBS10WLED865SPCSS or equivalent in Philips/Wipro/Polycab/Shakti
Supply & Fix Security light fitting 25 W IP 66 protection, color temp (Cool White) pressure die cost aluminium body with high power LEDs as light source and transparent diffuser, inbuilt electronic driver and luminous efficacy of 120lm/watt fixing on the GI bracket of not less than 25mm dia bend to shape as required at site and fixing with necessary GI clamps on the wall including connecting up with three core copper cable all as specified and directed. Make : Havells cat part No. ENDURASUNDOWNSL25WLED765PASYBOPCIHD or equivalent in Philips/ Wipro/ Crompton/Polycab/Shakti
Taking down existing ceiling fan, exhaust fan of any sweep, dismantling the blades and deposit the fans to MES store without any damage complete all as specified and as directed.
S & F for fixing the heavy duty exhaust fan of sweep 300mm,single phase 240V, 900 RPM including aluminum louvers and necessary fastner fixing accessoires to fix on any type of wall all as specified and directed. Make : Havells cat part No. Turbo Force SP or equivalent in Philips/ Wipro/ Crompton Note: Civil work for making hole to install exhaust fan is deemed to be included in the quoted rate.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make: Legrand/ L&T/Siemens/C&S
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of 2 poles and 40 amps current carrying capacity in the MCB DB complete with connection testing and commissioning. Make: Legrand /L&T/Siemens/C&S
Supply and fixing factory made epoxy powder coated Distribution Board VTPN 4 way double door with bus bar rating of 200 Amps including 125 Amps, 25KA, MCCB TPN as incomer & 63Amps, 16KA, TP as outgoing MCCB, with metal door (IP-43 protection, IK-09)as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes including taking down old one complete and making good of destructed surface including taking down old one complete complete all as specified Make: Legrand /L&T /Siemens/C&S
Supply and fixing factory made epoxy powder coated Distribution Board SPN 12 way double door ( MCB DB ) with bus bar rating of 100Amps and MCB DP as In comer, with metal door (IP-43 protection, IK-09)as per IES-61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes including taking down old one complete and making good of destructed surface including taking down old one complete complete all as specified Make: Legrand /L&T /Siemens/C&S Note: MCBs will be measured and paid seperately under respective Sch A item in the schedule
M&L for sub main wiring complete with 2 runs of 06 Sqmm PVC insulated heavy duty and unsheathed FRLS cable with multistranded copper conductor and drawing through in and including PVC conduit of suitable size and connecting terminal ends to meters and DB's including provision of 1 run of 06 Sqmm insulated copper cable for earth continuity conductor and connecting to earth dolly and taking down old u/s one complete all as directed by Eng-in-charge
Taking down carefully existing serviceable electric meters single phase and and refixing the same its original location after completion of building renovation work all as directed
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply earthing complete all as directed. Make: Havells/Crompton/Bajaj/Orient or its equivalent
M&L XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq mm 3 1/2 core
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, including trimming sides of foundations and forming bottom surface to required level, complete all as specified and directed by Engr in charge.
M & L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . NOTE:- Punned thickness shall only be measured and paid.
Supply and laying common burnt clay building bricks, sub-class grade "B" designation 75 Old size bricks all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engr in charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed by Engr in charge.
Material & Labour for steel tubing, medium grade, ISI marked, galvanised including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,) 50mm bore of pipe, complete all as specified and directed.
All as per item no 131 above, but of size 25 mm dia nominal bore,complete all as specified and directed.
All as per item no 131 above, but of size 20 mm dia nominal bore,complete all as specified and directed.
All as per item no 131 above, but of size 15 mm dia nominal bore, complete all as specified and directed.
Material & Labour for Gun-metal, globe or gate valves, conforming to IS 778, with iron wheel head, screwed both ends for iron pipe and fixed, 25mm bore of pipe, complete all as specified and directed.
All as per item No 135 above but of size 20 mm dia, complete all as specified and directed.
Making connection of G.I. distribution branch with G.I. main of 50 mm nominal bore size by providing and fixing tee, including cutting and threading the pipe etc. complete all as specified and directed by Engr-in-Charge
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/dense soil, including trimming sides of foundations and forming bottom surface to required level, complete all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm all as specified and directed by Engr in charge.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed by Engr in charge.
Anjana corporation
ELEVATORS MAINTENANCE ENGINEER WORKS
SUN LIGHT HOUSE
sri vishnu enterprises
S Anjan Reddy
KR PADMAVATHI CONSTRUCTIONS
SRI SAI ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .