Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.0 LAccepted-AOC | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹13.4 L+₹36,245 (2.79%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L-2 | Rejected-Finance Other than L-1 | |
| 3 | L-3₹13.9 L+₹94,651 (7.28%)Rejected-Finance | L-3 | Rejected-Finance Other than L-1 | |
| 4 | L-4₹14.5 L+₹1.5 L (11.5%)Rejected-Finance | L-4 | Rejected-Finance Other than L-1 | |
| 5 | L-5₹17.9 L+₹4.9 L (38.0%)Rejected-Finance | L-5 | Rejected-Finance Other than L-1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
26 Feb 2024, 6:00 pmClosed
Lt. Col Preetham P GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR AND MAINT OF EM ASSETS, FITTINGS, FIXTURES AND ALLIED WORKS FOR AVIATION ASSETS AND ATF PARKING AREA AT MANASBAL UNDER GE 970 EWS
2024_MES_639404_1
GE 970 EWS-63/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MANASBAL
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹48,000
Yes
3 Apr 2024
27 Jan 2024
2 Mar 2024
27 Jan 2024
26 Feb 2024
12 Feb 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody for reuse or for taking credit and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Material & labour for point wiring complete with single core 1.5 Sqmm (nominal area) PVC insulated multistranded, copper conductor cable (FRLSH) drawn through and including PVC casing capping (ISI marked) and accessories complete including cutting ,chases & making good disturbed surfaces), with plastic laminated backlite sheet top cover 3 mm thick (hylum) fixed with nickel polished screws with washers, earth continuity PVC cable(FRLSH), copper conductor 1.5 Sqmm (nominal area) stranded with green insulation earth wire connected with earth dolly One light point / fan point / bell push point controlled by one way switch 5 Amprs and/or through regulator ccomplete all as specified and directed.
Description all as per description of srl item No 2 here-in-before but socket out let 3 pin, 5 Amp on same board with other switch complete all as specified and directed.
Description all as per description of srl item No 2 here-in-before but socket out let 3 pin, 5 Amp on independent board with other switch complete all as specified and directed.
Description all as per description of srl item No 2 here in before but using 2.5 sqmm (nominal area) PVC stranded copper conductor cable with 1.5 Sqmm PVC insulated copper cable for continuous earth continuity conductor for 3 pin socket out let 15 Amps on independent board complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200Amp rated bus bar complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure double door for DBs when MCBs to be used SPN - 12 Way complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosure double door for DBs when MCBs to be used TPN- 12 (4+8) Way with 200Amp rated bus bar complete all as specified and directed.
Supply and fixing in replacement vertical distribution board TPN 4 way (VTPN DB) having pvovison for accommodating and including 100 amp MCCB as incomer and MCBs SP 6-32 amp as outgoing (8 + 12 ) modules as incomer and outgoing inclusive taking down old unsv from position and necessary cutting, chasing, drilling or any other civil work required for mounting the DB at place where directed and making good disturbed surface to match with the existing complete all as specified and directed.
Supply and fixing in replacement two pin and earth metal plug and socket complete with one single pole MCB 20 Amp, 240Volts complete all as specified and directed.
Supply and fixing in replacement MCB TPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement MCB SPN 63 Amp, 240 volts,10 KA, complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing MCB SPN 40 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement MCB SPN 32 Amp, 240 volts,10 KA,C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement residual current circuit breaker (RCCB) Double pole, 30 m Amp,25 Amp, 240 volts ccomplete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement residual current circuit breaker (RCCB) Double pole, 30 m Amp,40 Amp, 240 volts complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing in replacement residual current circuit breaker (RCCB) four pole, 30 m Amp,40 Amp, 240 volts complete all as specified and directed. Make: C&S/ L&T/SCHNIDER
Supply and fixing switch piano, flush type 5 Amps, 240 V One Way complete all as specified and directed.
Supply and fixing socket out let 5 Amps 3 pin flush type complete all as specified and directed.
Supply and fixing switch socket combination 5 Amps 2 in 1 flush type multipurpose complete all as specified and directed.
Supply and fixing switch socket combination out let 5A/15 Amps, 5 in 1 flush type complete all as specified and directed.
Supply and fixing bell push, flush type 5 Amps, 240 V One Way complete all as specified and directed.
Supply and fixing bell, AC, 230 volts, single pole complete all as specified and directed.
Supply and fixing in repair ceiling rose 3 terminal size 50 x 65 mm surface type complete all as specified and directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed.
Supply and fixing in repair 1X18 watt 4 ft long LED lights fitting , 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed : Havells /Philips/CG. Note:- Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in repair 1X9/10 watt 2 ft long LED lights fitting , 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed : Havells /Philips/CG. Note:- Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in repair sub main wiring for power/circuit using FRLS PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC casing capping on walls/roof/floors complete all as specified and directed. Notes:- Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit.
Supply and fixing in repair sub main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC casing capping of suitable size on wall/roof/floor and 6 Sqmm single run for earthing including taking down the old submain wiring complete all as specified and directed. Notes:- Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC conduit shall be measured as one unit.
BLANK
Supply and fixing in replacement decorative outdoor pathway light (landscape lighting) made up of high grade unbreakable polycarbonate materials of capacity 15W LED complete all as specified and directed. Make : Philips/Havells/CROMPTON. Note:- (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion. (ii) The unit rate shall be deemed to include the rates for PCC as required and nut bolts for fixing the light in the quoted rate.
Supply and fixing in replacement LED flood light 50/70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Note:- Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Note:- Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
BLANK
BLANK
Supply and fixing in replacement copper strip of size 20x3 mm as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
Supply and fixing in replacement square LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make: Havells / Bajaj / Philips. Note:- Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in replacement exhaust fan, steel body AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fixing in replacement air circulator wall mounted type for ventilation/cooling of UAV parking space of 600 mm dia,single phase 230/240V,AC, 50 Hz complete all as specified and directed. (Make : CG/Usha/Havells)
Supply and fixing in repair wall mounted fan 300 mm sweep for air ventilation/cooling of space,single phase 230/240V,AC, 50 Hz complete all as specified and directed. (Make : CG/Usha/Havells)
Supply and fixing in replacement new generatiion energy saving, enviornment friendly long life LED bldg security light fitting 30/35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and including suitable dia mounting bracket bend or weld to shape and length as required or complete all as specified and as directed. Make : Havells/Bajaj/Philips/CG Note:- (i) Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in repairs surface/ceiling light 3watt LED circular/square type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. Make : Havells/Bajaj/Philips. Note: Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Supply and fixing in replacement surface/ceiling/wall spot light 6/9 watt LED type with driver, holders & LED lamp suitable for wall/roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed. Make : Havells / Bajaj/Philips. Note: Contractor shall provide 2 years written manufacturer's warranty for the LED fixture complete including driver from the certified date of completion.
Material and labour for servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including replacement of heating element, thermostat,PVC connections and re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
Material and labour for periodical servicing of installed air conditioner of capacity 1.5/2 TR split air conditoner of any make /type, taking down indoor/outdoor units for cleaning dust/deposits, filters,drain hose,drain tray and chicking for gas pressure and replacement of minor spares required if any and refixing on same position complete all as specified and directed.
Material and labour for charging/top up refrigerant suitable for existing model of air conditoners and testing for proper cooling and leakage complete for AC/water cooler/refrigerator of any capacity all complete all as specified and directed.
Taking down or out existing cable of sizes 2/3.5/4 core 16 sqmm to 50 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester) complete all as specified and directed. Note : (1) Excavation and earth work, cutting of road or floor / GI pipe & laying / relaying of cable etc shall be measured and paid for separately under respective item of this schedule 2. Serviceable bricks/pcc cover retrived during taking out shall be reused. The cost of laying of old serviceable bricks / PCC cover shall be deemed to be included in the unit rate quoted.
Relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 2/3.5/4 core 16 to 50 sqmm in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as specified and directed. Note:- The cost of lugs and glands provided shall be deemed to be inclueded in the unit rate quoted.
Supply & Laying XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16sqmm 4 core including necessary cable lugs, glands, insulation tape , complete all as specified and directed.
Description all as per item Sl No 50 above but of size 16 sqmm 2 core complete all as specified and as directed.
Description all as per item Sl No 50 above but of size 25 sqmm 4 core complete all as specified and as directed.
Description all as per item Sl No 50 above but of size 35 sqmm 3.5 core complete all as specified and as directed.
Description all as per item Sl No 50 above but of size 50 sqmm 3.5 core complete all as specified and as directed.
S & F in replacement straight through joint (Heat Shrinkable) for under ground PVC insulated and PVC sheathed armoured heavy duty XLPE cables with aluminium conductor including jointing kit, including making joints for the cable of size 16sqmm x 4 core cables including testing and commissioining complete all as specified and directed. Make : Densons / 3M / Raychem
Description all as per item Sl No 55 above but of size 25 to 50sqmm x 3.5 / 4 core, as per the size of existing UG cable complete all as specified and directed. Make : Densons / 3M / Raychem
Supply & fixing in replacement digital type Ammeter 96X96 mm square Flush mounted case of class 1.0 complete all as specified and directed. MAKE : ELMEASURE / AE / IMP / MECO / MEI / HPL
Supply & fixing in replacement digital type Voltmeter 0-500V, 96X96 mm square Flush mounted case of class 1.0 complete all as specified and directed. MAKE : ELMEASURE/ AE / IMP / MECO / MEI / HPL
Supply & fixing in replacement CT 400 - / 5A, 200/5A or 100/5A for ammeter complete all as specified and directed. MAKE : AE / IMP / MECO / MEI / HPL
Excavation in trenches in soft / loose soil not exceeding 1.5m in width and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables ccomplete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and deposited at a level not exceeding 1.5m above from the starting point complete all as specified and directed.
M&L natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I complete all as specified and directed. Note : punned thickness shall be measured for payment purpose
Supply and lay un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm as protection of cable in trenches complete all as specified and directed.
M&L for cutting existing road / PCC drain for taking out / laying of underground cable not exceeding 50cm deepth and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified and directed.
M&L for 50mm dia GI pipe light grade galvanised for cable protection and sealing both ends including taking out old pipe complete all as specified and directed.
Supply and fixing in repair maintenance free battery 12V, 150 AH for battery bank set including initial filling & Charging complete all as specified and directed. Make: Excide/ Tata/ Microtech
Supply, installation and testing in replacement of automatic battery charger for 12/24/36/48 volt DC from 220/230V AC supply source with boost charging option suitable for charging lead acid/SMF battery and having indication for mains, float charging, boost charging, DC voltmeter,DC fail, AC fail alarm etc with circuit breaker for incoming supply, output load, over voltage, short circuit, reverse polarity and low and high voltage protection all accessories housed in heavy duty sheet metal enclosure, poweder coated finsih floor mounted complete all as specified and directed.
Supply & fixing in replacement 250 A, 4 pole MCCB, 36 KA, 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
Supply & fixing in replacement 250 A, 3 pole MCCB, 36 KA , 415V, 50 Hz, AC supply adjustable type of thermal and megnatic setting including necessary cable lugs & wire etc complete all as specified and directed.
Supply & fixing in repair 63/100 A 3 pole MCCB, 16KA , 415V, 50 Hz, AC supply including necessary cable lugs & wire etc ccomplete all as specified and directed.
Dismantling old unsv conventional earth pit including electrode plate/pipe from position and material and labour for maintenace free modern marconite® conductive concrete based technology earthing system in same or different place where directed with copper earth electrode of suitable size including back fill compound and other accessories as required and recommended by OEM and connecting with copper strip of size 25x3 mm in position (connecting upto 7.5 mtr length max) complete all as specified and as directed and having following specifications :- a) Fixed Carbon 98.5 % b) Ash, Volatile and Water 1.5 % c) Sulphur Content 1.5 % Maximum d) Size Grading (Approx) - 10% below 0.10 mm, 5% above 3.15 mm, 85% between 0.10 mm and 3.15 mm (e) Thermal Stability Between (-) 10% and (+) 60% ambient temperature (f) Ultra Low Resistivity (g) Versatile - shall be suitable for all type of soil and climate (h) Consistent Performance (i) Chemically Inert (j) Non-corrosive (k) Maintenance free and life span.
Supply & fixing in replacement off Load change over switch 100 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed.
Supply & fixing in replacement off Load change over switch 200 Amps, 4 Pole made out of Sheet steel enclosure side operated including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete all as specified and directed.
Supply & fixing in replacement sign board fabricated out of 2mm th mild steel sheet incl welding,bending to shape of size not less than 600x600 mm duly marked with letters/sign of shape and size as per existing or as directed and including necessary mounting arrangement, M.S. frame of angle iron of size 40x40x4 mm, steel work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and necesary PCC work in 1:4:8 type D-2 etc at suitable places complete all as specified and directed.
M/s Jaipal Associates
M/S MIR SAJAD ENTERPRISES
M/s Bilal Construction
M/S B A Traders
M/S BHAT ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .