Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAccepted-AOC 858 SECTOR 23 127021 | BHIWANI | HARYANA | 127021 | ₹10.1 Cr | L1 | Accepted-AOC Low amount |
| 2 | L2₹10.7 CrRejected-AOC 1804 SECTOR 2 ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹10.7 Cr | L2 | Rejected-AOC High amount |
| 3 | L3₹11.4 CrRejected-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI TEHSIL AND DISTRICT BHIWANI | BHIWANI | BHIWANI | HARYANA | ₹11.4 Cr | L3 | Rejected-AOC High amount |
| 4 | Not Admitted-Fee/PreQual/Technical HOUSE NO 399 NEAR UNION BANK BARWALA 125121 | HISAR | HARYANA | 125121 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.3 Cr
EMD Value
₹22.6 L
Closing Date
12 Apr 2022, 5:00 pmClosed
Executive Engineer, Bhiwani W/S Division Bhiwani
Canal colony Bhiwani
Laying HDPE pipeline from abadi area and low lined catchment area of 4 nos village i.e. Mundhal Kalan, Mundhal Khurd, Bandaheri, Talu outfall of various channels and drains.
2022_HRY_214706_1
423-48/9A Dt. 22.03.2022
Open Tender
Civil Works
360 days
Bhiwani W/S Division Bhiwani
Please refer tender documents
2 documents required · 2 mandatory
₹20,000
₹22.6 L
Yes
Bhiwani W/S Division Bhiwani
29 Jun 2022
29 Mar 2022
13 Apr 2022
29 Mar 2022
12 Apr 2022
29 Mar 2022
11 Apr 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.(HSR 4.12.1)
Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. M-15 PCC (HSR6.23.1.1)
Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure in: CM 1:4 (HSR 7.22.1)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of cantering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works up to plinth level (HSR 6.25.1)
Steel reinforcement for RCC work (HSR6.33.6 &6.34.6)
Shuttering for foundation concrete &foundation beams etc (HSR 6.29.1)
Centring and shuttering for walls, etc. (HSR 6.30.2)
Centring and shuttering for roof slabs. (hsr 6.30.3)
Providing and fixing 1 mm thick MS sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S gusset plate at the junctions and corner, all necessary fittings complete including applying a priming coat of approved steel primar. (HSR 13.6.1)
12 mm thick cement plaster 1:4 on brick walls Side Walls (HSR 11.5.3)
Tile Terracing over roof slab (HSR 7.35)
Supply and Fixing of Gantry with chain pulley block (testing for 1.5 times the rated capacity) with travelling trolley of appropriate lifting capacity as per IS Code 3177:1999 with up to date amendment for handling of pumping sets capable of moving along the girders including cost of suitable sized RCC pillars to be provided in pump house complete in all respects as per directions of Engineer-in-charge. (HSR 20.73.4)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm (HSR 4.16.1.3)
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for water supply application as per IS 4984:2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 315 mm Outside Dia
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 for water supply application as per IS 4984:2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Note: E/w to be measured and paid separately. Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 710 mm Outside Dia
Supplying erection testing and commissioning of Submersible motor pumping set non cling for sewerage having head 10.00 m as per the indicated requiremants of discharge in LPM and power capacity in BHP as per IS marked including all accessories (Like SS Pipes, SS chaina(Shackle chain), SS foundation bolt, complete base frame, mono railchain guideline, auto compling , duct food bend(D/F Bend) etc.complete in all respect.
Supply erection testing and commissioning of submersible motor pumping set non cong for sewerage having head 15.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (Like SS Pipes, SS chaina(Shackle chain), SS foundation bolt, complete base frame, mono railchain guideline, auto compling , duct food bend(D/F Bend) etc.complete in all respect.
Supplying of fully automatic electric control 2.0 No. panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing Min switch of suitable range with HRC tuse, 1 no. Fully autocratic air brake starter suitable for Motor of the following capacity Min switch of suitable range with HRC fuse, 1 no vott meter (o to 500 volts) 1 no amp Meter of 0 to 100 arnp .3 sets of indicating lamp capacitor of suitable capacity and suitable electing energy meter wing in Eluting Contro Panal Beard complete in all respect as per specification green in Schedule No,II. Including MCB. Suitable Capacitor. Wooden Box etc as per sit requirement complete in fat respect.
Providing, lowering, cutting, jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot & socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked anti-ternmite as per site into Trenchesfor all depth. (HSR 21.95.10) 1200 mm dia
Providing and laying 80 mm Thick factory made cement concrete interlocking paver block of M-35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 60 mm thick compacted bed of course sand, filling the joints with lime sand etc. all complete as per direction of Engineer-in-charge.
Brick work with common burnt clay non-modular bricks of class designation 10.5 in Foundation and plinth in: CM 1:4(HSR 7.21.1)
Narender Singh Contractor
MAHA LAXMI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid