Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAccepted-AOC 1ST FLOOR H NO 858 P SEC 23 HUDA BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | L1 | Accepted-AOC Low amount | |
| 2 | L2₹10.7 Cr+₹57.2 L (5.66%)Rejected-AOC 1804 SECTOR 2 HUDA 124001 | HUDA | ROHTAK | HARYANA | 124001 | L2 | Rejected-AOC High amount | |
| 3 | L3₹11.4 Cr+₹1.2 Cr (12.2%)Rejected-AOC HOUSE NO 953 SECTOR 23 HUDA BHIWANI 127021 | BHIWANI | BHIWANI | HARYANA | 127021 | L3 | Rejected-AOC High amount | |
| 4 | Not Admitted-Fee/PreQual/Technical HOUSE NO 399 NEAR UNION BANK BARWALA 125121 | BARWALA | HISAR | HARYANA | 125121 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11.3 Cr
EMD Value
₹22.6 L
Closing Date
12 Apr 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Bhiwani W/S Division Bhiwani
Canal colony Bhiwani
Laying HDPE pipeline from abadi area and low lined catchment area of 4 nos village i.e. Mundhal Kalan, Mundhal Khurd, Bandaheri, Talu outfall of various channels and drains.
2022_HRY_214706_1
423-48/9A Dt. 22.03.2022
Open Tender
Civil Works
Works
360 days
Bhiwani W/S Division Bhiwani
Please refer tender documents
2 documents required · 2 mandatory
₹20,000
₹22.6 L
Yes
Bhiwani W/S Division Bhiwani
29 Jun 2022
29 Mar 2022
13 Apr 2022
29 Mar 2022
12 Apr 2022
29 Mar 2022
11 Apr 2022
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.(HSR 4.12.1) | 8,771.78 | Cum | - | - |
| 2 | Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. M-15 PCC (HSR6.23.1.1) | 775.69 | Cum | - | - |
| 3 | Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure in: CM 1:4 (HSR 7.22.1) | 242.22 | Cum | - | - |
| 4 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of cantering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works up to plinth level (HSR 6.25.1) | 405.9 | Cum | - | - |
| 5 | Steel reinforcement for RCC work (HSR6.33.6 &6.34.6) | 43,799.69 | kgs | - | - |
| 6 | Shuttering for foundation concrete &foundation beams etc (HSR 6.29.1) | 130.02 | Sqm | - | - |
| 7 | Centring and shuttering for walls, etc. (HSR 6.30.2) | 2,078.56 | sqm | - | - |
| 8 | Centring and shuttering for roof slabs. (hsr 6.30.3) | 392.37 | Sqm | - | - |
| 9 | Providing and fixing 1 mm thick MS sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S gusset plate at the junctions and corner, all necessary fittings complete including applying a priming coat of approved steel primar. (HSR 13.6.1) | 26.51 | Sqm | - | - |
| 10 | 12 mm thick cement plaster 1:4 on brick walls Side Walls (HSR 11.5.3) | 1,994.74 | Sqm | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
recovered-award.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_282033.xls
BOQ Document • 0.25 MB
95248153.pdf
Tender Document • 2.46 MB
BID1.pdf
Tender Document • 1.42 MB
95248155.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .