Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.4 LAccepted-AOC SNEH NAGAR COLONY NEAR ABKARI OFFICE SHIVAJI WARD SAGAR MP 47000 | SAGAR | SAGAR | MP | 47000 | 1 | Accepted-AOC Lowest Bidder | |
| 2 | 2₹4.4 L+₹58,620 (15.5%)Rejected-Finance NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | 2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
18 Jan 2020, 6:00 pmClosed
SANJAY KUMAR AE CIVIL
AGE I DHANA PIN 470228, DIST SAGAR, MP
REPAIR/REPLACEMENT OF STANDBY GENERATOR SETS AND CERTAIN E/M REPAIRS AND APFC PANEL AT MIL STN DHANA
2019_MES_308981_1
8300/DH/47/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I DHANA
Please refer Tender documents
7 documents required · 7 mandatory
₹500
AGE I DHANA
₹9,000
Yes
13 Feb 2020
24 Dec 2019
20 Jan 2020
24 Dec 2019
18 Jan 2020
6 Jan 2020
Amount
M&L for Maintenance and servicing of DG set of capacity 140 to 160 KVA draining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge. (a) Fuel filter element (b) Oil filter elements (c) V-Belt (d) Air cleaner filter (e) Magnet Pickup (f) Hose pipe for radiator (g) Flexible Hose for vent (h) Fuel pipe return
M&L for Maintenance and servicing of DG set of capacity 12.5 KVA draining out of diesel from tank, cleaning the tank thoroughly and refilling drained diesel, drain out engine oil from the oil sump cleaning the sump and refilling the sump with new engine oil of Make K Oil 20W/40, to its maximum level, applying petroleum jelly on the Battery terminals and cleaning the entire DG set, checking and rectification of any defects of output voltage, RPM, exhaust leakages etc. Tightening the foundation & exhaust manifold bolts & nuts and testing as directed by the Engineer in Charge including replacement of following items complete all as directed and specified by Engr -In-Charge. (a) Fuel filter element (b) Oil filter elements (c) V-Belt (d) Air cleaner filter (e) Magnet Pickup (f) Hose pipe for radiator (g) Flexible Hose for vent (h) Fuel pipe return
M & L for preparation of old steel surface by cleaning , stopping and rubbing down and applying two coat of synthetic enamel spray painting on old painted steel surface of existing colour including cabin (inside & outside ) of any type of DG set all as directed and specified by Engr -In-charge.
S & F on pole / wall off load change over switch of capacity 100 Amps, 415 volts, side operated complete all as specified and directed. Make: - INDOASIAN/ HAVELLS.
M&L Engine oil 15W 40 of approved make as approved by EIC complete all as specified and directed. Make :- Servo/BP/Castrol
M&L for dismantling existing unserviceable radiator and carrying out repair by draining out water/coolant, carrying out pressure test and rectifying leakage by brazing/soldering test and reinstalling including topup/filling fresh coolant as on required basis all as directed and specified for DG set upto 160 KVA capacity etc., complete all as specified and directed.
Dismantling of unserviceable self starter 12 volts of DG Set of capacity 160/140/12.5 KVA including replacement of worn out parts like bendex, piston, bush housing etc including refixing and testing etc., complete all as specified and directed by Engr -In-charge.
Dismantling of unserviceable dynamo/alternator of DG Set of capacity 160/140/12.5 KVA including replacement of worn out parts like carbon bushes, solenoid switch bearing, armature etc including refixing and testing etc., complete all as specified and directed. by Engr -In-charge.
S & F in repairs Battery tubular 12 volt 180 AH For DG Set with connection complete all as specified and directed. Make:- Exide,Amron
Supply only distilled water in sealed bottle of one liter capacity complete all as specified and directed.
M&L for Earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized steel strip of size 32X6mm including 40 mm dia light grade protection, pipe 20mm dia watering pipe with funnel, CI hinged cover, PCC chamber and excavation and earth work complete all as described and shown in EP plate No 3 of SSR part I 2009 print and testing on completion all as specified and directed.
Supply and fix in repairs battery terminal made out of brass/bronze heavy duty suitable for 92 AH/180 AH 12 Volt Battery complete all as specified and directed.
Supply only Grease Multipurpose to increase equipment/ bearing life, Excellent resistance to throw off & water wash, Maximum protection offered against rust & corrosion complete all as specified and directed. Make:- Castrol, Servo, Mobil
Comprehensive maintenance and Repair/servicing of APFC Panel of following capacity for maintaining Power factor including by replacing the connected items etc installed for water supply installation complete all as specified and directed. Note :- Capacitor, Contactor, MCB will be measured and paid separately. (a) 90 KVAR APFC Panel at Bannad Pump House
(a) 60 KVAR APFC Panel at Filter Pump House
Taking down unserviceable capacitor and Supply and fix in replacement cylindrical capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 1 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 2 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 3 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 6.5 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 10 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 12.5 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
Taking down unserviceable capacitor and Supply and fix in replacement capacitor metalized poly propylene heavy duty (MPP - H) for three phase 440 V and 50 Hz system for permissible non - linear load 15 % of 25 KVAR capacity complete all as specified and directed. Make:- Neptune, L&T, Epcos
S & F in repair 3 pole contactor for capacitor switching 30 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA30-30-10RA of ABB or equivalent in L &T, Schneider
S & F in repair 3 pole contactor for capacitor switching 12.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA16-30-10RA of ABB or equivalent in L &T, Schneider
S & F in repair 3 pole contactor for capacitor switching 7.5 KVAR capacity, 220-240 Volts, 60 Hz complete all as specified and directed. Make- Cat no. UA9-30-10RA of ABB or equivalent in L &T, Schneider
Painting to existing APFC /LT panel board only one coat of synthetic enamel paint over a coat of red oxide primer after scraping, cleaning of old surface of electric panel complete all as specified and directed.
Taking down unserviceable volt meter and supply and fix digital volt meter range up to 500 Volt complete all as specified and directed.
Taking down unserviceable Amp meter and supply and fix digital Amp meter range up to 300 Amp complete all as specified and directed.
Taking down unserviceable lamp indicator RYB and supply and fix led lamp indicator RYB complete all as specified and directed.
M&L for MCB SP, 240 volt, 5 to 30 Amps complete all as specified and directed. Make:- Havells/L&T/C&S
M&L for MCB TPN, 415 volt, up to 63 Amps complete all as specified and directed. Make:- Havells/L & T/ C & S
S & F in replacement MCCB 4 pole 36 KA 315 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 36 KA 250 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 36 KA 200 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 36 KA 125 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 25 KA 100 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
S & F in replacement MCCB 4 pole 25 KA 63 A suitable for Adjustable type setting complete as specified and directed. Make:-Legrand, Havells, Schinieder
NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 4990.00 /- ]
M/S JAINENDRA KUMAR JAIN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .