Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.6 LAccepted-AOC 62A OFFICER COLONY AZAD NAGAR HISAR 125001 | HISAR | HARYANA | 125001 | L-1 | Accepted-AOC Quoted rates are lowest | |
| 2 | L-2₹34.0 L+₹68,786.63 (2.07%)Rejected-AOC | L-2 | Rejected-AOC Quoted rates are higher | |
| 3 | L-3₹34.9 L+₹1.6 L (4.77%)Rejected-AOC | L-3 | Rejected-AOC Quoted rates are higher |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Feb 2023, 4:00 pmClosed
Director
Maharaja Agrasen Medical College Agroha (Hisar)
Replacement of Old PVC Water Storage Tanks and Precast CC Water Storage Tanks into New PVC Water Storage tanks with around MS Jali (Wire mesh) on various buildings at MAMC Agroha
2023_HRY_256691_1
MAMC/Engg./678 Dated 03-02-2023
Open Tender
Civil Works - Others
Works
45 days
Maharaja Agrasen Medical College Agroha (Hisar)
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Yes
₹60,000
Yes
28 Mar 2023
4 Feb 2023
24 Feb 2023
4 Feb 2023
23 Feb 2023
4 Feb 2023
Amount
Civil Works Items Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: HSR 6.1 6.1.1 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for 6.30.3 Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level HSR 6.33 Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6.33.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : HSR 7.22 7.22.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping. HSR 10.14
15 mm cement plaster on the rough side of single or half brick wall of mix : HSR 11.6 11.6.1 1:4 (1 cement: 4 fine sand)
Pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand): HSR 11.26 11.26.1 Flush/ Ruled/ Struck or weathered pointing
Applying priming coat: HSR 11.68 11.68.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. HSR 11.114
Providing and fixing hard drawn steel wire fabric 75 mm X 25 mm rectangular mesh with 3.25 mm dia wire fixed on steel windows of standard rolled sections with 3 mm thick flat iron cover moulding of 12.5 mm width fixed with machine screws welded complete in all respect. HSR 13.18
Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. HSR 30.19
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. HSR 13.29 13.29.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Public Health Work Items Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge :HSR 5.55 5.55.1 15 mm to 40 mm nominal bore
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. HSR 30.89
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. HSR 22.87 External work 22.87.3 25 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : HSR 22.98 22.98.1 25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : HSR 22.103 22.103.1 15 mm nominal bore 22.103.3 25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181
Providing & fixng CPVC Unior 25mm dia complete in all respect Make Prince, finolex & diplast (N.S.)
Providing & fixng CPVC Handel Valve 25mm dia complete in all respect Make Prince, finolex & diplast (N.S.)
Providing & fixng CPVC Tank nipple 25mm dia complete in all respect Make Prince, finolex & diplast (N.S.)
Haryana Swimming and Sports Academy
the azad haryana co-op multi Purpose Society
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .