Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹23.7 L+₹1.3 L (5.70%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹23.9 L+₹1.4 L (6.36%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹24.3 L+₹1.8 L (8.05%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹24.8 L+₹2.3 L (10.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
3 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_351760_1
CA NO CWE/JAL/E-21/2020-21 8320/21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jalandhar Cantt
Class D Category a(i) or b(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
Garrison Engineer East JRC
₹74,000
Yes
18 Aug 2020
11 Jun 2020
5 Aug 2020
11 Jun 2020
3 Aug 2020
4 Jul 2020
60 days
Amount
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sqmm, all as specified and directed by Engineer in charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.
Supply & laying un-reinforced precast concrete cable cover, class HV, type I, flat, size 300mm x 180mm x 40mm, ISI marked laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
Supply and fix cable jointing kit for 11 KV (earthed) grade for indoor end termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 240 sqmm, all as specified and directed by Engineer in charge.
M & L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directed by Engineer-in-charge.
Supply, installation, connecting, testing and commissioning out door type 11 KV, 630 Amps, Outdoor fixed type (IP54), RMU (Ring main unit) 5-way with Bus metering Unit comprising of 2 Nos 630 Amps, manually operated Load Break Switch (Comprising Two Nos. Incomers) & 2 No. motor operated Vacuum Circuit Breaker as Outgoing and 1 No. bus sectionalizer consist of manually operated Load break switch. All LBS, VCB and Bus Sectionalizer shall be enclosed inside robotically /manually/TIG welded stainless steel 304 (Non Ferrite Non Megnetic Grade) filled with SF6 gas at suitable pressure in accordance with the IEC 60298. tank having min. thickness 2.5 mm having IP 67 Degree of Protection. RMU should be provided with internal busbars, as well as earthing busbars should be of copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of 21kA/3 sec as per IEC62271-200. RMU shall be equipped with site replacable bushing. The earthing busbar shall be provided inside each cable compartment for soilid earthing of Cable sheilds.The outer enclosure main door should cover entire part of the switchgear including front cover and cable doors for providing complete IP 54 protection including raised foundation of suitable size, minimum 50 cm above and 01 meter below the natural ground levels and all as per manufacur's drawing. The unit shall include the following with all necessary standard fitting as required at site.
(a) 2 Nos. Incoming Load Break Switch module should consist of following accessories : 630A Load Break Switch module for making and breaking of fault current alongwith Earth Swicth of full making capacity Short time current - Not less than 21KV/ 1 sec Making Capacity - 50KA Auxiliary contacts - 1NO + 1NC Power frequency withstand voltage - 28KV Impulse withstand voltage - 75KV Nominal operating gas pressure - 1.3 (minimum) Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11 KV XLPE cable, Right angle boots (push on type) Suitable site replaceable Cable bushings. Arc proof cable covers with self Interlocking mechanism with earth switch Capacitive voltage indication fixed type system as per IEC61243 (i) -Impulse withstand voltage- 75kVP (an altitude<1000 m above msl) (ii) -SF6 Gas pressure indicator-03 Nos for whole RMU (iii)- Live cable indicating LEDs energised through capacitive voltage dividers. (iv) All feeders of RMU shall be provided with multifunction meters having complete range of measurement including maximum demand and shall have serial port for communication. (v) Metering compartment of RMU shall be provided with auxiliary transformer of suitable capacity to supply power to batterry charger. (vi) Integral earthing switch with making switch (vii) Emergency Trip push button (viii) RMU shall be provided with metering and protection CTs shall be 200-100/5/1, 5P10, 2.5VA and for metering CT shall be 200-100/5/1A class 1, 2.5 VA
(b) 1 No. busbar sectionalizer module should consist of following accessories : Sectionalizer load break switch 12kV, 630A Snap action mechanism for manual operation (c ) Outgoing Breaker module should consist of following accessories: (i) 630A Vaccum Circuit Breaker module for making and breaking of fault current alongwith Earth Swicth of full making capacity. VCB should be capable to clear 40 dead short circuit operation. (ii) Short time current - Not less than 21KV/ 1 sec (ii) Making Capacity - 50KA (iii) Auxiliary contacts - 1NO + 1NC (v) Power frequency withstand voltage - 28KV (vi) Impulse withstand voltage - 75KV (vii) Nominal operating gas pressure - 1.3 (minimum) Bar abs. (viii) Front cover mechanism - IP2X (ix) Cable covers - 3X (x) Stored Enegry mechanism for Motor operation- 24VDC (xi) Cable box for front termination of the cable suitable upto 3 core 400 Sqmm, 11 KV XLPE cable (xii) Right angle boots (push on type) (xiii) Self Powered Microprocessor based Relay (3 O/C & E/F) with standard settings (xvi) Digital Multifunction meter (A, V, KW, KVA, F, PF) with RS 485 port type Rishabh/ Elmeasure (xvii) Suitable site replaceable Cable bushings (xviii) Arc proof cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB (xix) Capacitive voltage indication fixed type system (xx) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged, 230 V AC shunt Trip coil for external trip (xxi) Transformer card for auxiliary protection as per manufacturer's design conforming to relevant IS
(d) Bus Connected PT Unit -2 No. for Metering (1 No. Metering module for each breaker) consisting of following:- Type M: Air Insulated metering module 12KV, 630A, 21KA for 3sec. (i) - 3 Voltage Transformers of the ratio 11kV/√3 / 110 V/√3, 50 VA, Class 1.0 with HT fuses on primary side and MCB on secondary side. (ii) -Microprocessor based IDMT(50, 50N, 51, 51N) relay for overcurrent, short circuit and earth fault protection. (iii) - 1 CFL Illumination. (iv) - 2 Space Heater with thermostat. (v) - Each RYB phase indications for 2 incomers and 2 out going. (vi)- 1 Cable support bus bars, standard for 5 way unit, (vii)- 1 set Bushings for external busbar connection along with Busbar cover & Sleeved busbars for coupling. (viii) - 2X12 V Battery with battery charger with suitable burden for motor operation. Input 230 V AC & Output 24 V DC. (a) Capacitive voltage indication fixed type VPIS 9-15 kV (b) Necessay interclocking arrangement for safety and operations (c ) One No. Operating Handle for Manual Operation. (d) One No. Manometer. (e) Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (f) Above switchgear shall confirm to all relevant IEC/IS Standards. (g) Manual operation of Vacuum Circuit Breaker should be possible without dismantling the motor from RMU. The motor should be fitted in such a way that it should not be outside front covers of RMU. (h) Coupling of RMU and Metering module should be with the help of Bolted type arrangement, so that the coupling at site shall be easy. Plug-in type bushing shall not be acceptable. (j) All Cable bushing should be replaceable type. (k) Module should accommodate as per manufacture's design. (l) RMU cable box shall be front accesible type to have easy access to protection and metering CTs. Vaccum Interupter should be of same make. Cable box should be arc proof with bolted door and interlocked with respective earthing switchs. Doors should be removable for the ease aceess to terminate cables. Note :- (i) The contractor will submit NABL accredited lab test reports of the RMU's in original and the same shall be produced well before claiming RAR payment of the RMU.(ii) Pre-despatch inspection shall be carried out by Rep of Accepting Officer.All arrangement for the same shall be provided by the contractor & shall be considered within quoted rates and all civil work like Excavation, PCC fdn, Brick work, RCC slab & all other works as per manufacturer's instructions shall deemed to be included in unit rate quoted by the contractor.
Supply installing, commissioning & testing HT 11 KV, 3 phase 50 Hz, repturing capacity 350 MVA, indoor type, totally metal clad withdrawable type Vacuum Circuit Breaker Outgoing panels with Copper bus bar of suitable rating horizontal isolation type VCB of capacity minimum 800 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25KA, No of operation of Vacuum Interrupter Bottles for better performance: (i) Mechanical life-30,000, (ii) Rated electrical operations-10,000/- & (iii) Rated Short Circuit Current -100 All the main components like VI/VCB/Relays/Meters shall be of same make. Panel and VCB parameters are as below:- (i) Rated Voltage level/PF withstand voltage/impulse level 12 KV/28KV/75KVp. (ii) Continuous current rating minimum 800A. (iii) Short circuit withstand current minimum 25KA for 3sec. (iv) One no minimum 800 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:-
M&L for earthing complete using galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically at a depth not less than 2.25 metres deep below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below normal ground level connected with and including GI stips 32mm x 6mm in and including GI pipe 50mm bore medium grade as protection pipe (from top of earth plate upto the body of equipment) by means of GI bolts, nuts, check nuts, GI washers, timbles; earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh PCC chamber of size 300mm x 300mm x 300mm (top of chamber minimum 15cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate and angle iron frame including necessary excavation/ earthwork in any type of soil/ rock and as shown in electrical plate No. 3 of SSR part-I (2009) testing on completion complete all as specified with the following:- (i) Test point GI of size 75mm x 75mm x 25mm. (ii) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with brass wire mesh embedded infloor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit withopen top suitable for watering of earth pits). (iii) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25cm thick with 2 Nos MS handles of 12mm dia shitable for carrying of pit cover. (iv) Angle iron frame made of 40mm x 40mm x 4mm angle iron for 30mm x 30mm PCC pit for holding the pit cover. Note : (a) The unit rate shall be include for protection pipe GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32mm x 6mm from the earth plate and upto metallic body of the equipment/panel board etc. or 7.5 metre whichever is more. (b) PCC pit shall be provded at least 0.5 metre away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. (c) RCC pit cover shall be 80mm thick pre-cast RCC (1:2:4) type B-1 reinforced with XPM weighing not less than 4Kg/ Sqm of size 300 mm x 300 mm in lieu of CI cover.
Material and labour for fixing cable route indicators made of PCC (1:3:4) duly engraved “MES HT CABLE / HT JOINT” coloured with two coats of synthetic paint in brown of size 150 x 150 x 900 mm fixed 300mm below ground level in PCC(1:3:6) all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass-concrete including form work complete all as specified and directed.
S&F mild steel works as in posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire fencing/chain link fencing etc flat iron fillets (for securing chain link fencing etc) including all necessary drilling, bolting or reveting, welding etc and embeding in concrete and securing etc. and similar works conforming to Fe- 410-0 or Fe-310-0. All as specified and directed by Engr-in-Charge.
S& F chain link fencing including 10 gauge thick galvanised steel wire and 50x50mm size mesh fixed to steel fencing post by nut and bolts etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
M &L steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed .
S&F Mild steel bolts. purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. approved by Engineer-in-Charge.
M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. as specified and directed
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6mmean radius built in CM 1:4 complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on brick or concrete surface all as specified and directed
Materials and labour for broken stone or boulder hard core of gauge n.exc, 63mm deposited spread and leveled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
Material and labour for Cement concrete 1:4:8 Type D2 (40 mm graded aggregate) in foundations, filling and mass concrete all as specified and directed.
Material and labour for Cement concrete 1:3:6 Type C2 (20 mm graded aggregate) 100mm thick as in subbase of flooring complete all as specified and directed.
M & L for 30mm sand cushion, filling under floors or in foundations including watering and consolidation all as specified and directed.
M & L for laying 60 mm thick machine pressed precast concrete interlocking paver block and shape and size conforming to IS -15658-2006 of M-30 Grade with grey cement and pigment complete all as specified and directed. NOTE: The sample shall be got approved from the GE before bulk procurement and lots shall be got tested independtly by the GE.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point as specified and directed
GULSHAN SINGH GHAI AND SON
R D Bansal
SATISH AND CO
AK Construction Co
Raman Electric Trading Co
M/S BALWINDER SINGH
UNITED ENGINEERING CORPORATION
siddharthenterprises
CHOUDHARY AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .