| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | ₹26.0 L Quoted ₹27.5 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹29.9 LRejected-Finance | ₹29.9 L | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹33.0 LRejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹33.0 L | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹33.2 LRejected-Finance | ₹33.2 L | L4 | Rejected-Finance Being other than lowest bidder |
| 5 | L5₹35.0 LRejected-Finance 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹35.0 L | L5 | Rejected-Finance Being other than lowest bidder |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L3 | Srinivasa Consructions L4 | MS ENTERPRISES L6 | SUN LIGHT HOUSE L1 | SVG SUPPLIES L5 | Srinivash Engineers L2 | DPS sales and services india L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L in replacement for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed. | 6 | Each | 72 ₹432 | 36 ₹216 | 163 ₹978 | 150 ₹900 | 100 ₹600 | 50 ₹300 | 350 ₹2,100 |
| 2.00 | M&Lin replacement for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed. | 6 | Each | 81 ₹486 | 40 ₹240 | 163 ₹978 | 100 ₹600 | 120 ₹720 | 50 ₹300 | 350 ₹2,100 |
| 3.01 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.
Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose. | 30 | Each | 180 ₹5,400 | 200 ₹6,000 | 263 ₹7,890 | 200 ₹6,000 | 110 ₹3,300 | 80 ₹2,400 | 900 ₹27,000 |
| 3.02 | Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.
Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.
(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes. | 30 | Each Job | 360 ₹10,800 | 200 ₹6,000 | 273 ₹8,190 | 500 ₹15,000 | 130 ₹3,900 | 100 ₹3,000 | 1,400 ₹42,000 |
| 3.03Notes for Item Nos 3.01 to 3.02 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/ M, Secunderabad and the same shall be submitted to E/ M No II store on daily basis. | ||||||||||
| 3.04Notes : 1.Contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measures are to be adopted by the contractor on site 3. The complaints shall be rectified within 24 hrs , if the complaints is / are not attended / not completed within 24 hours recovery will be done at Rs 100 per complaint per day M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- | ||||||||||
| 4.00 | S&F in replacement Stay assembly comprising of 7/ 10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/ mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/ bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/ taking out old existing unsv stay assembly complete all as specified and directed. | 5 | Per Set | 1,170 ₹5,850 | 3,000 ₹15,000 | 2,993 ₹14,965 | 1,500 ₹7,500 | 1,200 ₹6,000 | 900 ₹4,500 | 2,250 ₹11,250 |
| 5.00 | M&L in replacement for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size with insulator/ stretching of ACSR conductor including disconnecting/ taking out old existing unsv ACSR conductors complete all as specified and directed. | 2 | Qtl | 18,900 ₹37,800 | 23,000 ₹46,000 | 9,993 ₹19,986 | 15,000 ₹30,000 | 25,000 ₹50,000 | 12,000 ₹24,000 | 7,200 ₹14,400 |
| 6.00 | S&F in replacement of Galvanised steel wire (GI) 4mm dia including disconnecting/ taking out old existing unsv GI wire complete all as specified and directed. | 0.5 | Qtl | 8,100 ₹4,050 | 10,000 ₹5,000 | 8,863 ₹4,431.5 | 5,500 ₹2,750 | 4,200 ₹2,100 | 4,500 ₹2,250 | 15,300 ₹7,650 |
| 7.00 | M/ L in replacement for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing unsv cross arms complete all as specified and directed. | 1 | Qtl | 9,000 ₹9,000 | 10,000 ₹10,000 | 8,883 ₹8,883 | 6,000 ₹6,000 | 9,500 ₹9,500 | 7,888 ₹7,888 | 6,750 ₹6,750 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
31 Dec 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR/ RENEWAL OF OH LINE, LT UG CABLE, REPLACEMENT OF OH LINE, CUTTING OF TREE BRANCHES AND ALLIED WORKS AT MCEME, DEPOT BN, EME RECORDS, NML, OHL, ECO, FALUKNAMA, AGAMAN AND ADJOINING AREA UNDER AGE EM II OF GE(UTILITY) SECUNDERABAD
2025_MES_742661_1
GE (U)/SEC/TOKEN/58 OF 2025-26
Open Tender
Electrical and Maintenance Works
270 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹80,000
Yes
23 Feb 2026
3 Dec 2025
7 Jan 2026
3 Dec 2025
31 Dec 2025
17 Dec 2025
Amount
M&L in replacement for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed.
M&Lin replacement for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed.
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Notes for Item Nos 3.01 to 3.02 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/ M, Secunderabad and the same shall be submitted to E/ M No II store on daily basis.
Notes : 1.Contractor should visit the site before quoting the tender to know the working condition of the station. 2. All requisite safety measures are to be adopted by the contractor on site 3. The complaints shall be rectified within 24 hrs , if the complaints is / are not attended / not completed within 24 hours recovery will be done at Rs 100 per complaint per day M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
S&F in replacement Stay assembly comprising of 7/ 10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/ mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/ bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/ taking out old existing unsv stay assembly complete all as specified and directed.
M&L in replacement for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size with insulator/ stretching of ACSR conductor including disconnecting/ taking out old existing unsv ACSR conductors complete all as specified and directed.
S&F in replacement of Galvanised steel wire (GI) 4mm dia including disconnecting/ taking out old existing unsv GI wire complete all as specified and directed.
M/ L in replacement for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing unsv cross arms complete all as specified and directed.
Supply &Fix in Replacement of MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/ IS:13947-II) in exisitng LT Panel box/ Feeder Pillar boxes (KIOSK), in MCCB DBs of capacity 315-400 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/ taking out existing old unsv/ burned MCCB complete all as specified and directed.
All as per item No 8.00 here in before but of capacity 250 Amps, 4 pole, 25 KA
All as per item No 8.00 here in before but of capacity 200 Amps, 4 pole, 25 KA
All as per item No 8.00 here in before but of capacity 160 Amps, 4 pole, 25 KA
All as per item No 8.00 here in before but of capacity 125 Amps, 4 pole, 16 KA
All as per item No 8.00 here in before but of capacity 100 Amps, 4 pole, 16 KA
All as per item No 8.00 here in before but of capacity 63 Amps, 4 pole, 16 KA
S&F in replacement MCCB, 63 Amps, 3 pole, 415 Volts with breaking capacity 16KA, including disconnecting/ taking out existing old unsv/ burned MCB complete all as specified and directed.
All as per item No 9.00 here in before but of capacity 100 Amps, 3 pole, 415 Volts with breaking capacity 16KA
All as per item No 9.00 here in before but of capacity 160 Amps, 3 pole, 415 Volts with breaking capacity 16KA
S&F in replacement MCB, SP 10-32 Amps, 'C' Curve with breaking capacity 6KA, including disconnecting/ taking out existing old unsv/ burned Isolator complete all as specified and directed.
Supply, lay, commissioning and testing in replacement of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LTUG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 13.00 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 13.00 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core
All as per item No 13.00 above but suitable for aluminium conductor cable of size 240 sqmm, 3.5 Core
All as per item No 13.00 above but suitable for aluminium conductor cable of size 300 sqmm, 3.5 Core
Supply and lay in replacement in trenches/ fixed to walls/ poles etc connecting by using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No 14.00 above but 2 Core 10 Sqmm
All as per item No 14.00 above but 4 Core 16 Sqmm
All as per item No 14.00 above but 4 Core 25 Sqmm
All as per item No 14.00 above but 3.5 Core 35 Sqmm
All as per item No 14.00 above but 3.5 Core 50 Sqmm
All as per item No 14.00 above but 3.5 Core 70 Sqmm
All as per item No 14.00 above but 3.5 Core 95 Sqmm
All as per item No 14.00 above but 3.5 Core 120 Sqmm
All as per item No 14.00 above but 3.5 Core 150 Sqmm
All as per item No 14.00 above but 3.5 Core 185 Sqmm
All as per item No 14.00 above but 3.5 Core 240 Sqmm
All as per item No 14.00 above but 3.5 Core 300 Sqmm
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/ 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: (Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevant Item)
Taking out and Relaying of LT cable of size 70 sq. mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: (Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevant Item)
Taking out and Relaying of LT cable of size 185 sq. mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: (Earth work , sand Cushioning, brick protection, LT Joints shall be measured and paid separately under Relevant Item)
Supplying, erecting and fixing in replacement steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
All as per item No 19.00 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Spreading riddled earth (after preparation of excavated earth) in Cable duct with sand cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM(6.25 Cm below cable and 11.75 cm above cable) will be measured for payment purpose. Quoted rate inclusive of all arrangement as mentioned.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/ drain crossing by adopting trenchless tunnelling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any type of soils including hard rock, HDPE pipe medium duty of size 100 mm dia in any length including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed.
Supply and laying in replacement GI tubing light grade of size 40 mm for cable protection on road/ drain/ floor/ pole including necessary clamps 40x4mm all as specified and as directed..
Supply and laying in replacement GI tubing light grade of size 50 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and as directed.
Supply and laying in replacement GI tubing light grade of size 80 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and as directed.
Restricting/ Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and pruning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/ 4/ 6 runs) i.e. one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc.
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/ maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamel base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Trimming/ pruning and removing of tree branches or any other foreign objects from HT/ LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way / 4 way/ 6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premises/ around 2/ 4 Pole structure/ along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
Supply and fixing in replacement steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F in replacement hot press moulded SMC junction/ terminal box of size with internal dimensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat of Size 4 Sqmm complete all as specified and directed.
All as per item No-69 above but of size 6 Sqmm complete all as specified and directed.
All as per item No-69 above but of size 10 Sqmm complete all as specified and directed.
S&F in replacement LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
Supply and fix in replacement of aluminium cable lugs of following sizes :-
16 to 25 Sqmm Size
35 to 50 Sqmm Size
70 to 95 Sqmm Size
120 to 150 Sqmm Size
185 to 240 Sqmm Size.
S&F in replacement of MCCB factory made enclosure box with neutral link for TP System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) MCCB 63 Amps 16 KA TP .
S&F in replacement of MCCB factory made enclosure box with neutral link for TP System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) MCCB 100 Amps 16 KA TP .
Supply and fix in replacement on wall with necessary arrangements busbar chamber 100 amps 4 way 4 pole wall mounted , made out of 1.6 mm thick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Supply and fix on wall in replacement with necessary arrangements busbar chamber 200 amps 4 way 4 pole wall mounted , made out of 1.6 mm thick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
M&L for repairing of automatic operation of high mast lantern including all arrangements required including crane and replacement of all unserviceable spares of high mast lighting system of height 12 m to 20 meter . Quoted rates deemed to be inclusive of the following:- (i) crane as required for taking down of high mast pole including light without any damage to the mast, lantern and lights etc and refixing the same after repairing of the all problem on the same position (ii) Necessary disconnection and reconnection of electrical connection. (iii) Replacement of all unserviceable spare like High mast head, high mast ring , stainless steel wire, clamp, winch, transition plate, service door , Hook ring, nose plate, cabinet, gear, reel, transmission belt etc including servicing of gear box , filling of gear oil, greasing etc complete (quoted rates deemed to be inclusive of all spares required for proper functioning of lantern system except stainless steel wire, High mast head, high mast ring etc.
Supply only steel wire rope 6mm dia (7/ 19 construction) suitable for high mast system including u bolt complete all as directed
Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at high mast pole of capacity upto 2.2/ 3 HP and refixing of the same including necessary arrangement complete all as directed
Supply only in replacement power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed.
All as per item No 57.00 above but 10 KVAR Capacitor Bank complete all as specified and directed.
All as per item No 57.00 above but 20 KVAR Capacitor Bank complete all as specified and directed.
S&F APFC relay etaCON M series with auto-set function 7/ 8/ 12 stage APFC relay complete all as specified and directed.
Supply and fix in replacement Power contactor coil of Power contactor of having capacity 360/ 400 Amps 4 pole 2NO +2NC complete all as specified and directed.
Supply and fix in replacement Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed.
Supply and fix in replacement Power contactor of having capacity 360 Amps 4 pole 2NO +2NC complete all as specified and directed.
Disconnecting electrical connection and overhauling the mechanical parts incl Greasing Oiling and re-assembling the same as required and , made the Crane serviceable including making all electrical Connection and Testing complete all spd and directed for following capacity Note : All Spares parts of Crane measured and paid separately under relevant Item.
Capacity 05 ton
Capacity 10 ton
Supply and fixing in replacement of 3P power contactor rating 26-40 Amps incl taking down unserviceable one complete all as specified and directed
Supply only Over load relay Magnetic type of range 26 - 40 Amps
Testing (full load test , deflection test , capacity test , speed test , and break test) and serviceability checking of each cranes by authorised Engineer in presence of JE (E/ M) and generating & submission of the test certificate with list of defects if any to be produced in duplicate. The capacities of cranes to be tested are as under :-
Electrically operated over head travelling (EOT) cranes of capacity from 05 ton to 10 ton - 02 Nos.
Supply only crane gear oil for filling/ topping up of Type EP-320 thick level complete all as directed.
M&L for preparation of old painted surfaces for outdoor/ indoor Amf panel/ LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032 complete all as specified .
S&F in replacement cable route indicator for LT UG cable of 1100 volts bolted with 25x5 mm flate iron member of height 0.60 mtrs and 80 mm CI plate embedded in PCC 1:3:6 type C2 of size 15x15x20 cm block complete all as specified
Supply and fixing in replacement lantern of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aluminium painting over a coat of red oxide primer complete all as directed
Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Supply, Installation, test and Commissioning in replacement factory fabricated, out door type, LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, , suitable for 440 Volt 3 Phase 4 Wire System , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable , cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following
(a) Aluminium bas bar 300amps - 04 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 200 amps , 415 volt , 25 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 No
Srinivash Engineers (BID ID -3505533)
L and S ENTERPRISES (BID ID -3506348)
Srinivasa Consructions (BID ID -3506464)
SVG SUPPLIES (BID ID -3506628)
MS ENTERPRISES (BID ID -3511264)
DPS sales and services india (BID ID -3506895)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
NIT.pdf
Tender Documents • 0.26 MB
BOQ_831630.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid