| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹5.8 L+₹70,840 (13.9%)Rejected-AOC | L2 | Rejected-AOC other than lowest | |
| 3 | L3₹6.0 L+₹87,760 (17.2%)Rejected-AOC | L3 | Rejected-AOC other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
10 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) REASI
REASI C/O 56 APO
REPAIR TO DRAIN AND SEWAGE LINE AT REASI UNDER AGE(I) REASI
2022_MES_499364_1
AGE (I)REASI-38/2021-22
Open Tender
Civil Works
Item Rate
270 days
AGE (I) REASI
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE (I) REASI
₹20,000
Yes
3 Mar 2022
4 Jan 2022
12 Feb 2022
4 Jan 2022
10 Feb 2022
19 Jan 2022
60 days
Amount
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles including removing the rubbish obtained from demolition n.exc 50m, complete, all as specified and directed.
M&L for brick work built in CM 1:4 with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, complete all as specified and directed.
M&L for Random rubble masonry built in cement mortar 1:6, uncoursed, well bonded, bedded and solidly hearted, complete, all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6, complete, all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, complete, all as specified and directed.
M&L for 15 mm thick rendering on other than fair faces of brick or stone surfaces of wall in cement mortar 1:4 and finished even and smooth without using extra cement, complete, all as specified and directed.
M&L for 20 mm thick rendering on other than fair faces of stone masonry surfaces of wall in cement mortar 1:4 and finished even and smooth without using extra cement, complete, all as specified and directed.
M&L for preparing plastered or unplastered new surfaces of walls and applying three coats of white wash, complete, all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete, all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, rough finished surface of concrete, complete, all as specified and directed.
TMT bars 10mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips, complete, all as specified and directed.
TMT round bars 10mm dia and over in handle and binding and fixing with mild steel wire, complete, all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregates as in lintels upto 1.50 metre clear span,cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form works, complete, all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in surface channels and drains, complete, all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete, all as specified and directed.
M&L for 100mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in floor and finished even and fair, complete, all as specified and directed.
M&L for Machine pressed precast conctete prelaminated rubberised coloured interlocking paver block of approved shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade set jointed and laid with grey cement and pigment, complete, all as specified and directed.
Supply only sand for filling under floors or in foundation or for laying floor finishes, complete, all as specified and directed.
Excavation in trenches in soft/ loose soil n.exc 1.5 m deep and getting out including forming bottom to required level or slop for laying pipe, concrete bed manhole etc n.exc 10 Sqm on plan complete all as specified and as directed. Note : Pipe and concrete bed shall be measured and paid separately.
Returning filling in soft/ loose soil including spreading levelling, watering and well ramming in layers not exc 25 mm thick complete, all as specified and as directed.
Removing of excavated surplus materials to a distance exc 50 m but n.exc 100 m and depositing where directed at a level n.exc 1.5 mtrs above the starting point complete, all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling and mass concrete, complete all as specified and directed.
M&L salt glazed stone ware drain pipes of internal diameter 150 mm grade 'A' laid in trenches and jointed, complete, all as specified and directed.
Demolition or breaking up 150 mm dia drain pipe including fittings of any desciption in any position and removing rubbish upto a distance of n. exc 50 mtr, complete all as specified and directed.
M&L concrete bed to drain pipes of bore 150mm including packing under,and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate including necessary shuttering and supports, complete, all as specified and directed. Note:- (i) Thickness of bed below barrel of pipe -10 cm. (ii) Width of bed :- 15 cm beyond either side of the pipe.
S&F in repair 110mm bore PVC (SWR) branch bends any radius complete, all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floors, complete all as specified and directed.
Demolition of reinforced cement concrete as in cover slabs of any description, removal of debris to beyond MoD land, complete all as specified and directed.
M&L for precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in manhole cover slab with plain fair faces and set in CM 1:4, complete all as specified and directed.
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of ₹ 9,395.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
M/S THAPPA TRADERS
m/s vaid contractor and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .