| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.8 LAdmitted-Finance | +4.90% | ₹1.8 L | L1 | Admitted-Finance |
Tender Value
₹1.8 L
EMD Value
₹3,500
Closing Date
26 Mar 2026, 6:00 pmClosed
EE PWD Elect Dn Udaipur
EE PWD Elect Dn Udaipur
AMC of ACs in TB Hospital Badi, Udaipur (2025-26)
2026_CEPWD_547720_2
NIT_23_2025-26_EE_PWD_ED_Udr
Open Tender
Electrical Works
365 days
Udaipur
As per bid
2 documents required · 2 mandatory
₹500
EE PWD Elect Dn Udaipur through Egras Challan
₹3,500
Yes
EE PWD Elect Dn Udaipur
6 Apr 2026
20 Mar 2026
27 Mar 2026
20 Mar 2026
26 Mar 2026
20 Mar 2026
24 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair / replacement of compressor, condensing/ cooling coil , refrigerant piping , fan motor , remote , charging of refrigerant when ever required and periodical servicing as per OEM's recommendations to meet out the efficient performance of the equipment. | |||||
1.5/1.8/2.0 Tr Split type air conditioner | - | Job / Yr | - | - | |
1.5/2.0/3.0/4.0 Tr Cassette type Split type air conditioner | - | Job / Yr | - | - | |
| 2Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
2.5 sq.mm x 3 core | - | Mtr. | - | - | |
| 3SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves, chase cutting, supports, making good the same with sand cement plaster etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
Annexure "A" attached with this BSR . | - | Kg | - | - | |
| 4Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
20 mm | - | Mtr. | - | - | |
| 5Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capillary and strainer/ filter. | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Financial_Bid_2_AMC_AC_TB.pdf
Tender Documents • 4.35 MB
BOQ_976565.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid