Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | Admitted-Finance |
| 2 | Admitted-Finance NOT AVAILABLE | Admitted-Finance |
| 3 | Admitted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹63,100
Closing Date
26 Dec 2022, 3:00 pmClosed
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
MH
Providing, installation, testing and commissioning of electro-mechanical machinery alongwith allied works at WSS Kail
2022_PHE_199965_1
ENIT NO. 03-JJM OF 2022-23
Open Tender
Repair and Maintenance Works
Item Rate
60 days
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
Providing, installation, testing and commissioning of electro-mechanical machinery alongwith allied works at WSS Kail
5 documents required · 5 mandatory
₹500
XEN JAL SHAKTI PHE MECHANICAL DIVISION UDHAMPUR
₹63,100
2 Jan 2023
17 Dec 2022
27 Dec 2022
17 Dec 2022
26 Dec 2022
17 Dec 2022
Amount
Providing, installation, testing and commissioning of 5000 GPH x 250 meter head HC pump set with suitable rating prime mover in compliance with the technical conditions and allied works by way of surveying of site, designing of pump machinery and prime mover in conformity with site conditions. Laying of M-20 grade RCC foundation block for each pump of size 6’x3’x4’ by using reinforcement steel of 10mm dia. The foundation block as per size of pump set should have additional margin of 6” on all sides. The foundation block may be combined for all the pumps which must includes space on all sides of pump set and space between the pump sets. Providing, fabrication and laying of 80mm dia MS suction pipe line to the pump set of length as per site conditions including 80mm dia MS bends, MS flanges, expanders/reducers / dismantling joints / saddles/ pipe extension pieces, manifold, 80mm dia Cast Iron sluice valve-1no. and / or foot valve-1no., gaskets, nuts, bolts, washers as per site requirement. Providing, fabrication and laying of 80mm dia MS delivery pipe as per site conditions including MS bends, MS flange, expanders/reducers / dismantling joints/ saddles/ pipe extension pieces, Cast steel Sluice valve 80mm dia and NRV 80mm alongwith by pass arrangement (class 300 accompanied with manufacturer’s in house test certificate)gaskets, nuts, bolts, washers,100mm dia manifold as per requirement and making connection with the rising main. Job includes greasing work, P/F of graphited gland packing and thereafter testing on no load and then on full load and commissioning thereof. Job includes providing / fitting and laying of copper cable 50mm2 from motor to panel in six leads approximately 36 meters for each motor, then p/f and laying 95mm2 copper cable from panel upto MCCB in four leads and further upto voltage stabilizer in four leads approximately 30 meters in length conforming to ISI standards with proper thimbling and insulation material. Job covers providing and fitting of 250 ampere MCCB of 50KA breaking strength. Proper earthing of the equipment should be done for safety of machinery. Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools, tackles, and material handing equipments etc.
Providing, carriage, installation, testing and commissioning of 3 phase, 100 KVA voltage stabilizer copper wound, first quality CRGO silicon steel core, naturally- oil cooled, manually operated, 14 gauge container chamber alongwith allied works at WSS Kail. Job includes providing of 100 KVA voltage stabilizer complete with mineral insulating oil, MCCB, change over switch complete with safety and protection devices etc. Job includes providing and fitting of single core armoured Al. cable of 150mm2 from electric pole to main switch in four leads approximately 50 meters length of each lead and then providing and fitting of 95mm2 copper cable from main switch to voltage stabilizer in four leads approximately 20 meters in length and must have required insulation and thimbling as per site requirement .The voltage stabilizer should have 5 upwards steps and 2 downwards steps (or as per the designed/ specified voltage range) from the line voltage i.e. it should work from 180V to 400+5%. Proper earthing of the equipment shall be done. Complete Job includes cost of machinery, equipments and material, transportation charges, manual carriage charges, labour charges, loading /unloading charges, hire charges of tools and tackles etc. Note:- 1. Any other accessory / job which has not been mentioned here but is mandatory and inevitable for accomplishment of work and proper functioning of the equipments shall also be provided and executed at no extra cost.
GANPATI ELECTRICAL AND MECHANICAL WORKS
N B Engineering and Electric Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .