Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.0 L+₹62,567.35 (4.06%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.7 L+₹1.3 L (8.27%)Rejected-AOC AUSTINABAD CHINTAMBAR COLONY PORT BLAIR SOUTH ANDAMAN 744 103 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-AOC L3 | |
| 4 | L4₹17.0 L+₹1.6 L (10.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹17.2 L+₹1.8 L (11.7%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹28,900
Closing Date
5 Jan 2021, 6:00 pmClosed
GE (I) Campbell Bay
Garrison Engineer (I), Military Engineer Services, Army Land, Great Nicobar Islands, Campbell Bay, Pin 744 302
PROVISION OF CLOSED SHED FOR DIESEL STORAGE AT INS KARDIP KAMORTA UNDER GE(I) CAMPBELL BAY
2020_MES_403580_1
8729/E8
Open Tender
Civil Works
Item Rate
180 days
Campbellbay, Kamorta
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹28,900
Yes
15 Mar 2021
15 Dec 2020
7 Jan 2021
22 Dec 2020
5 Jan 2021
22 Dec 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as in beams, bands, cantilevers, bressummers, lintels over 1.5m span, all as specified and directed.
M&L for Reinforced cement concrete M30 (Design Mix) using 20 mm graded stone aggregate as Chajjas all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns raft and raft beams sides and soffits of foundation and plinth beam and similar work vertical or to batter all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, column and stanchions for rough finished surfaces of concrete square, Circular rectangular on plan or polygonal all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete flat all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks of PCC 1:3:6 type C-1 using 20 mm graded aggregate , exc. 10 cm in width and setting in mortar 1:6, complete all as specified and directed.
M&L for Mild steel TMT reinforcement Bars of 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clip all as specified and directed.
Same as above but 6mm to 8mm
M&L for Mild steel TMT reinforcement bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securing with clip all as specified and directed.
M&L for Hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface all as specified and as directed.
M&L for 100 mm thick PCC 1:3:6 type C-2, (using 40 mm graded aggregate) as sub base floor complete all as specified and directed.
M&L for 75m mm thick plain cement concrete type B-2, 1:2:4 mix using 40mm graded stone aggregate as in plinth protection, pavings, path etc. surface finished even and smooth without using extra cement complete as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-1, (using 20 mm graded aggregate) as floor finished even and rough including making 6 mm wide grooves to full depth at 2 to 3 m interval and at every change of direction and filling the grooves with mixture of bitumen and sand mixed in the ratio of 1:3 by weight complete all as specified and directed.
M&L for nonskid coloured Ceramic joint free tiles (Matt finish) 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cement mortar 1:6 over 25 mm thick PCC screed 1:2:4 type B-0 using 12.5 mm graded stone aggregate all as specified and directed.
M & L for chequered cement concrete tiles of size 20cmX20cmX25mm thick set jointed and pointed in grey cement and pigment to match over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S & F aluminium (dia cast ) body door closer hydraulically regulated designation No 3. universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg and fixed complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed..
M&L for Rendering 15 mm thick in cement plaster 1:4 on external fair faces of solid block or concrete surfaces finished fair and even without using extra cement complete all as specified and directed.
M&L for Rendering 10 mm thick in cement plaster 1:6 on fair faces ofsolid block or concrete surfaces finished fair and even without using extra cement all as specified and directed.
S&F Roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. confirming to Fe 410-W (Gde E-250) quality A all as specified and directed.
S & F for mild steel screw bolts 16 to 20 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends to be fitted with washer and one hexagonal or square nut exceeding 22.5 and n.exce 30 CM long all as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa, (AZ-150) as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
S&F of Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa, (AZ-150) as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat of colour wash over one coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coat of cement base paint over one coat of primer complete all as specified and directed.
M&L for Preparation of new or previously un treated surfaces of steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome paint all as specified and directed.
S&F Mild steel work as in wind ties, including all necessary drilling, bolting or riveting required size etc , and similar work confirming to Fe 410 - 0 or Fe 310 -0 all as specified and directed.
M&L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc., complete all as specified and directed.
S&F of Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S&F of Anodised aluminium window and ventilator shutters glazed and gauged, side hung type without sash bars for aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long 1No, hingestype B-21 100 mm long 2 Nos, suitable handles 1 No etc., complete all as specified and directed.
S&F of 4 mm thick Sheet Glass, ordinary quality and glazing with oil putty in sqare n.exce .5 sqm in each pane in aluminum windows etc all as specified and directed.
M&L for 12 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to aluminum doors / partitions all as specified and directed.
S & F anodised aluminium snap grid frame (with minimum 15 micron uniform anodic coating) size of 605x605mm consisting of Tee/Angle section, size 40x40x2mm as approved make conforming to IS-733 in frames of false ceiling including aluminium cleats with necessary CP brass/stainless steel shunk screws. Aluminium perimetre angles fixed to wall/wooden frame at centre to centre and fixing frame to level adjusting anchors 8mm dia GI wire with hook in Tee members at 1.5m centre to centre fixed to steel trussed roofs all as specified and directed.
S & F perforated particle board/ tiles 12mm thick for insulation and accoustic purpose, 600mmx600mm size fixed in ceiling on snap grid with fixing clips etc all as specified and directed.
M&L for XLPE insulated, armoured heavy duty underground electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 16 sqmm 2 core laid in trenches / fixing on walls / poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
M & L HDPE Double Wall Corrugated (DWC)pipes,ISI marked,with outer diameter 50 mm and inner diameter 38 mm conforming to IS-14930 Part-II including necessary pipe fittings such as couplers,end caps,bends,clamps etc laid in trenches/on wall for cable protection complete for cable protection complete all as specified and directed .
Material and labour for point wiring 1.5 sq mm FRLS Copper cable 1100 volt grade drawn in and including stove enamelled steel ERW conduit not less than 19mm dia including spacers, saddles, screws etc & 1.5 sqmm PVC insulated copper earth wire including including connected to flame proof switches/sockets etc on independant all as specified and directed.
Supply & Fix Switch piano, flush type single pole, one way 5 Amp complete all as specified and directed
S&F BULK HEAD CFL light fitting flameproof type FLP-WP of 1x 26 W built in control gear box made of aluminium alloy LM6 , with all accessories, ballast, lamp holders, etc. internally prewired complete all as specified and directed
S&F sheet metal enclosure factory made double door for DB 240 volts with 200 amps rated bus bar SPN 4 way complete all as specified and as directed.
S&F MCB SPN-20 amps, 'C' curve, 240 volts complete all as specified and directed
S&F MCB SP 5 to 32 amps, 'C' curve, 240 volts complete all as specified and directed
M&L Sheet metal enclosure weather proof for mounting over wall / floor including locking arrangement for housing of 4 Way SPN DB & switches complete all as specified & directed
M&L flameproof exhuast fan of 300 sweep complete all as specified & directed
M & L For Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 15mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
S K ENTERPRISES
SUMAN
USR Transport
M/s K Moorthi
P Babu
DEEPAK AGENCIES
B.R. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .