| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹24.5 L+₹27,187 (1.12%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹24.5 L+₹34,097 (1.41%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹28.7 L+₹4.5 L (18.6%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L4 | Rejected-Finance Other than Lowest Tenderer | |
| 5 | L5₹31.5 L+₹7.3 L (30.1%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹33.8 L
EMD Value
₹67,700
Closing Date
2 Jul 2020, 6:00 pmClosed
GE Nagrota
Office complex of GE Nagrota
Day to day complaints of internal electricfication, repair / rewinding of varrious capacity of fan at various location and rewiring of bldg no. P-274, TS-440 and TS-438 at RandO under GE Nagrota.
2020_MES_348153_2
GEN-15/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Nagrota
As per NIT
8 documents required · 8 mandatory
₹500
GE Nagrota
₹67,700
Yes
18 Sept 2020
12 Jun 2020
4 Jul 2020
12 Jun 2020
2 Jul 2020
19 Jun 2020
Amount
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective switch/socket/ceiling rose/holders/fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc, complete all as specified and directed.
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs / MCB DBs/TPN/ TPN DBs any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc, complete all as specified and directed.
NOTE FOR ITEM NO 1 to 2 :- (a) All T & P/Stationeries and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily, as directed. (b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after reciving, Rs 500/- per complaint will be penalised.
Supply only in replacement Switch piano flush type 5 Amps single pole one way complete, complete all as specified and directed.
Supply only in replacement socket out let multipurpose suitable for 2/3 pin 5 amp flush type, complete all as specified and directed
Supply only in replacement switch socket combination 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
Supply only in replacement switch socket combination 2 in 1, 5 pin 5 /15 Amps flush type, complete all as specified and directed.
Supply only in replacement ceiling rose surface type, 2-3 terminal 65x50mm, complete all as specified and directed
Supply only in replacement step type fan regulator 300 watt, 230 volts, 50 HZ, AC, complete all as specified and directed.
Supply only in replacement batten/angle type holder insulated body with back plate, complete all as specified and directed.
Supply only in replacement bell push piano type 5 Amps, complete all as specified and directed.
Supply only in replacement electric bell ding dong 230 volt AC, complete all as specified and directed.
Supply only in replacement Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, Cat part No. BLRB DB 118 ( for batten fitting) & Cat part no. BLRB18W CW LED (for LED 18 watt ) of Bajaj or equivalent in approved make, complete all as specified and directed.
Supply only in replacement baton integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 as per Cat No BCLSB 05 WH of Bajaj or equivalent in approved make, complete all as specified and directed.
Supply only in replacement white powder coated CRCA housing with LEDs 36W, 230 V, 50 Hz recess mounting LED 2 feet x 2 feet luminaries, Swamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat part No.BZRSQL 36W GZ WH of Bajaj or equivalent in approved make, complete all as specified and directed.
Supply only in replacement LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and directed.
Supply only in replacement LED bulb 7 watt, complete all as specified and directed.
Supply only in replacement LED tube rod suitable for any type of LED Tube Light fitting of 18/20 watt, complete all as specified and directed.
Supply only in replacement compact electronic ballast and FTL Rod suitable for any type fluorescent tube light fitting of 1x36 watt, connecting and testing, complete all as specified and directed.
Supply only in replacement compact electronic ballast and FTL Rod suitable for any type fluorescent tube light fitting of 1x28 watt, connecting and testing, complete all as specified and directed.
Supply only in replacement compact electronic ballast and FTL Rod suitable for any type fluorescent tube light fitting of 1x14 watt, connecting and testing, complete all as specified and directed.
Supply only in replacement modular Switch piano flush type 6 Amps, 230 V AC single pole one way, complete all as specified and directed.
Supply only in replacement modular Switch piano flush type 16 Amps, 230 V AC single pole one way, complete all as specified and directed.
Supply only in replacement modular socket outlet with shutter multipurpose suitable for 2 pin and 3 pin 6 amp flush type, complete all as specified and directed.
Supply only in replacement modular socket outlet with shutter multipurpose suitable for 6 pin 16 amp flush type, complete all as specified and directed.
Supply only in replacement modular bell Switch 6 Amps, 220 V single pole, complete all as specified and directed.
Supply only in replacement electronic modular fan regulator,Two module, electronic,step type and connection, complete all as specified and directed.
Supply only in replacement MCB single pole 32/40Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB single pole 40 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB TP/TPN 50 to 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Taking down carefully aluminium conductor point wiring (light fan, socket and power) complete with fittings such as switches, sockets, lamps holder, utility light fitting, fan regulator etc and making good disturbed surface of walls and floors etc. and keeping in safe custody for taking credit, complete all as specified and directed.
M & L for Point wiring with PVC insulated, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into with and including PVC casing capping not less than 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed steel concealed terminal boxes of reqd size made out of 1.2 mm thick sheet covered with 2.8 mm thick plastic laminated bakalite (hylam) ISI marked sheet suitable for switches/sockets/regulators complete all as specified & directed for the following :-
One light/fan/exhaust point /bell point controlled by one switch
One point for socket outlet 5 amp on independent board
All as per ser itme no. 32.00 here in before but point wiring for one 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board
S & F in repair Sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
S & F in repair Sheet metal enclosure distribution board SPN 2 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail, complete all as specified and directed.
S & F in repair Sheet metal enclosure double door for distribution board factory made for MCB DB load link TPN 4 way suitable for MCCB as incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification, complete all as specified and directed.
S&F in repairs of MCCB 125 Amps, 4 pole, 415 Volts, 16 KA, with adjustable thermal and adjustable magnetic settings as per existing at site, complete all as specified and directed by Engr-in-Charge.
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmm as earth continuity conductor connected to commen earth and earth dolly including taking down old cable, complete all as specified and directed.
S & F Switch piano flush type 5 Amps single pole one way, complete all as specified and directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
S & F Switch socket combination 2 in 1 5 pin 5 /15 Amps flush type, complete all as specified and directed.
S & F Ceiling rose surface bakalite, 3 phase complete PVC/polycarbonate isolated body, complete all as specified and directed.
S & F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required, complete all as specified and directed
S & F in repairs Integrel sleek extruded batten aluminium /CRCA channel fitting with LED 18 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, Cat part No. BLRB DB 118 ( for batten fitting) & Cat part no. BLRB18W CW LED (for LED 18 watt ) of Bajaj or equivalent in approved make, complete all as specified and directed.
S & F in repairs white powder coated CRCA housing with LEDs 36W, 230 V, 50 Hz recess mounting LED 2 feet x 2 feet luminaries, Swamless front frame with flat white hight transmission acrylic cover complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size of Cat part No.BZRSQL 36W GZ WH of Bajaj or equivalent in approved make, complete all as specified and directed.
S & F in repairs LED light fitting 1x9W bulk head luminaries IP 65 complete with all accessories including LED lamp 9 watt , connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V 50 Hz, complete all as specified and directed.
S &F Lamp holder PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S & F LED bulb 7 watt , complete all as specified and directed.
S & F MCB single pole 32/40 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
S & F MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply and laying or fixing including removing of existing cable 1100 volts grade cable PVC insulated aluminium conductor un-armoured of 16 Sqmm 2 core flat or circular, served with inner sheathing of pace tape and overall PVC sheathed in service connection suspended by insulated hangers not more than one Mtr apart including 4 mm dia suspension GI wire, complete all as specified and as directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion, complete all as specified and directed.
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles, stay foundation and under ground electric power cables and getting out, complete all as specified and directed..
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point, complete all as specified and directed.
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge..
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
All as per ser iitem No. 58.00 here in above but cross sectional area 25 sqmm 4 core
All as per ser iitem No. 58.00 here in above but cross sectional area 16 sqmm 2 core
Supply only installation and commissioning and testing of LT pannel cubical type suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply systemfabricated from stainless steel totally enclosed dust weather and verminn proof, 3.00 mm thick for outer sheell and 2 mm thick for inhnner shell hvaing MS section not less than 50x50x6mm thick having TPN aluminium busbar of capacity 200 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement with MCCB FP 100 Amp, 16 KV, 415 50 HZ with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with gland including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of valtage, amp with indicators RYB painting with wo coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-charge. Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be deemed to included in the quoted rate.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 3 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Disconnecting and taking down unserviceable Ceiling Fan, 1400/1200 mm sweep , 230 Volts AC supply Elecric driven single phasefrom position for winding and refixing for the same after winding, necessary connection, complete all as specified and directed. Note: Winding shall be measured and paid in respective item.
All as per ser itme no. 63.00 here in before but exhaust fan of size 450/380/300/255mm sweep
All as per ser item no 63.00 here in before but wall mounted fan of size 450/400 mm sweep
M&L for collecting unserviceable ceiling fans 1200mm sweep 230 v, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the ceiling fan and taking out complete burnt winding from fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling , greesing & painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface of the fan with and including replacement of rusted /unserviceable nuts, bolts split pin rubber reel , machine screws, shaft etc including replacement of defective / unserviceable parts / spares as required reassembling the fan and testing complete deposinging the complete repaired fan to E/M store yard of GE Nagrota including transportation, complete all as specified and derected.
All as per ser itme no. 66.00 here in before but ceiling fan of size 1400mm sweep
M&L for collecting unserviceable exhaust fan 450mm sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the exhaust fan and taking out complete burnt winding from exhaust fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface replacement of rubber pads and depositing the exhaust fan to E/M store yard GE Nagrota including transportation and testing etc complete all as specified and derected.
All as per ser item no 68.00 here in before but exhaust fan of size 380 mm sweep
All as per ser item no 68.00 here in before but exhaust fan of size 300 mm sweep
M&L for collecting unserviceable PVC exhaust fan 250mm sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the exhaust fan and taking out complete burnt winding from PVC exhaust fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing and depositing the exhaust fan to E/M store yard GE Nagrota including transportation and testing etc, complete all as specified and derected.
M&L for collecting unserviceable wall mounted fan 450/400mm, sweep 230 V, AC supply, single phase from E/M store yard of GE Nagrota , Dismantling the wall mounted fan and taking out complete burnt winding from wall mounted fan motor and rewinding the same with super enameled copper winding wire of existing gauge & size including thoroughly cleaning all the components of fan, oiling & greesing painting with one coat of syntetic enemel paint after scrbbing and perparing the old painted surface replacement of rubber pads and depositing the wall mounted fan to E/M store yard GE Nagrota including transportation and testing etc, complete all as specified and derected.
Taking down carefully from position , ceiling fan, 1400 mm sweep, 230 volts single phase 50 Hz from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note: Neccessary accessories paid seperately in respective item.
All as per ser item no 73.00 here in before but ceiling fan of size 1200 mm sweep
Taking down carefully exhaust fan 230 volts single phase 50 Hz 450 mm sweep from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note: Neccessary accessories paid seperately in respective item.
All as per ser item no 75.00.00 here in before but exhaust fan of size 300/380 mm sweep
Taking down carefully wall mounted fan 230 volts single phase 50 Hz 450 mm sweep from the position & removing/ cleaning of dust properly, oiling and greasing of bearing including necessary repairs and refixing and connecting up with all requisite accessories complete all as specified and directed. Note: Neccessary accessories paid seperately in respective item.
Supply only in replacement of gun metal bush of required size suitable for ceiling fans and exhaut fans, complete all as specified and directed
Supply only in replacement of hanger for ceiling fan 1200mm/ 1400 mm sweep with nuts, bolts, washers, complete all as specified and directed.
Supply only in replacement ofaluminium blades for ceiling fan 1200 mm sweep, complete all as specified and directed.
Supply only in replacement of aluminium blades for ceiling fan 1400 mm sweep, complete all as specified and directed.
Supply only in replacement of bearing suitable for ceiling fan of any size, complete all as specified and directed.
Supply only in replacement of bearing suitable for Exhaust fan/Air circulator/wall mounted fan of any size, complete all as specified and directed .
M&L scrubbing and preparing the old painted surfaces of ceiling fan of size 1200/1400mm sweep complete including blade and painting the same with white duco paint and writing the MES Nos of the fans, 25mm with black synthetic enamel paint and including oiling greasing of any make, complete all as specefied and directed.
M&L scrubbing and preparing the old painted surfaces of exhaust fan of size 300/450mm sweep complete including blade and painting the same with white duco paint and writing the MES Nos of the fans, 25mm with black synthetic enamel paint and including oiling greasing of any make, complete all as specefied and directed.
Supply & Fix canopy top and bottom for ceiling fans, complete all a spcified and directed.
S & F in repairs flexible twin core 23/0.0076 with copper conductor including connecting fan of any make, complete all as specified and directed.
S&F in replacement 300mm long fan down rod with clamp heavy duty as required, complete all as specified and directed.
S&F in replacement exhaust fan frame made out of MS sheet of any make and size of exhaust fan with suitable size of nut bolt and washers, complete all as specified and directed
Material and labour for replacement of Unserviceable Louvers with new louvers of exhaust fan 450mm sweep, complete all as specified and directed.
Material and labour for replacement of Unserviceable Louvers with new louvers of exhaust fan 300/380 mm sweep, complete all as specified and directed.
S&F in repairs oil filled condenser of 2.5 MFD capacity after removing existing unserviceable condenser from any situation, complete all as specified and directed.
S&F in repairs oil filled condenser of 4 MFD capacity after removing existing unserviceable condenser from any situation, complete all as specified and directed.
S&F in replacement blade suitable for wall mounted fan 400/450 mm sweep fan, complete all as specified and directed
Supply & fix in replacement for shackle assembly for ceiling fan, complete all as specified and directed.
Point wiring with PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches, sockets, regulators with and including 1.5sqmm FRLS multi stranded copper conductor drawing as continuous earth wire connected to main earth and earth dolly complete all as specified for the following;-
One light/fan/exhaust point /bell point controlled by one switch
One point for socket outlet 5 amp on same board
One point for socket outlet 5 amp on independent board
All as per ser itme no. 96.00 here in before but point wiring for one 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 93622.00 during AOC Note:- Tenderers shall not quote for this Schedule
Nitika electricals and engineers works
M/S MANISHA BUILDERS
VIJAY BUILDERS
R K BUILDERS
Allied Technologies
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .