Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-Finance | ₹12.2 L | L1 | Accepted-Finance L1 |
| 2 | L2₹12.2 LRejected-Finance | ₹12.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹12.2 LRejected-Finance | ₹12.2 L | L3 | Rejected-Finance L3 |
Tender Value
₹12.2 L
EMD Value
₹24,382
Closing Date
24 Feb 2026, 12:00 pmClosed
DDAADMNS24PGS
New Administrative Building Alipore, Kolkata-700027
Construction of packaging cum value addition shed 4 (four) number under PKVY fund. in the district of South 24Pgs.
2026_DOA_1003283_1
NIT07202526
Open Tender
CIVIL WORKS
See the tender notice
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹24,382
27 Feb 2026
11 Feb 2026
26 Feb 2026
11 Feb 2026
24 Feb 2026
11 Feb 2026
Within Gosaba P.S.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm
Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. includingwateringand rammingetc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation.1/3 of earth work in cutting.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor [Pakur Variety] 1:3:6 proportion
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc.For trusses spanning up to 12.00 m TRUSS 40mm NB Medium @3.56kg/m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping).300 mm lapping each way With 0.71 mm sheet
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement Pakur Variety 35 mm. Thick.
Brick work with 1st class bricks in cement mortar (1:4) In foundation & plinth
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 1:3 ,20 mm thick plaster
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick clear glass. For window
Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974with non-friction projecting type,box type hinges,glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete(1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Open able steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only.
M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S.flats and bars.
M.S.gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting,bolting,welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface :two coats.
Applying decorative cement based paint of approved quality afterpreparing the surface including scraping the same thoroughly(plastered or concrete surface) as per manufacturer's specification.
Neat cement punningabout 1.5mmthick inwall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Supplying and Drawing 1.1KV single core stranded 'FR' PVCi nsulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following size sinthe pre laid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Distribution wiringin 1.1KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) insuitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated &unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch(Anchormake) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment andmending good damages to building works[PVC casing-capping on surface and Switch board concealed]Average rum 5m.
Within Namkhana P.S.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm
Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. includingwateringand rammingetc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation.1/3 of earth work in cutting.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor [Pakur Variety] 1:3:6 proportion
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc.For trusses spanning up to 12.00 m TRUSS 40mm NB Medium @3.56kg/m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping).300 mm lapping each way With 0.71 mm sheet
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement Pakur Variety 35 mm. Thick.
Brick work with 1st class bricks in cement mortar (1:4) In foundation & plinth
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 1:3 ,20 mm thick plaster
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick clear glass. For window
Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974with non-friction projecting type,box type hinges,glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete(1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Open able steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only.
M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S.flats and bars.
M.S.gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting,bolting,welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface :two coats.
Applying decorative cement based paint of approved quality afterpreparing the surface including scraping the same thoroughly(plastered or concrete surface) as per manufacturer's specification.
Neat cement punningabout 1.5mmthick inwall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Supplying and Drawing 1.1KV single core stranded 'FR' PVCi nsulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following size sinthe pre laid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Distribution wiringin 1.1KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) insuitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated &unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch(Anchormake) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment andmending good damages to building works[PVC casing-capping on surface and Switch board concealed]Average rum 5m.
Within Joynagar-II P.S.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm
Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. includingwateringand rammingetc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation.1/3 of earth work in cutting.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor [Pakur Variety] 1:3:6 proportion
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc.For trusses spanning up to 12.00 m TRUSS 40mm NB Medium @3.56kg/m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping).300 mm lapping each way With 0.71 mm sheet
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement Pakur Variety 35 mm. Thick.
Brick work with 1st class bricks in cement mortar (1:4) In foundation & plinth
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 1:3 ,20 mm thick plaster
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick clear glass. For window
Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974with non-friction projecting type,box type hinges,glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete(1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Open able steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only.
M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S.flats and bars.
M.S.gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting,bolting,welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface :two coats.
Applying decorative cement based paint of approved quality afterpreparing the surface including scraping the same thoroughly(plastered or concrete surface) as per manufacturer's specification.
Neat cement punningabout 1.5mmthick inwall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Supplying and Drawing 1.1KV single core stranded 'FR' PVCi nsulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following size sinthe pre laid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Distribution wiringin 1.1KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) insuitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated &unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch(Anchormake) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment andmending good damages to building works[PVC casing-capping on surface and Switch board concealed]Average rum 5m.
Within Baruipur P.S.
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm
Earthwork in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mm. includingwateringand rammingetc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)With earth obtained from excavation of foundation.1/3 of earth work in cutting.
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity).
Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor [Pakur Variety] 1:3:6 proportion
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental changes such as electricity charges, labour insurance charges etc.For trusses spanning up to 12.00 m TRUSS 40mm NB Medium @3.56kg/m
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).With 0.5 mm thick sheet
Aluminium sheet ridging fitted with self tapping screws, EPDM washers etc complete.(Minimum 225mm end lapping).300 mm lapping each way With 0.71 mm sheet
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement Pakur Variety 35 mm. Thick.
Brick work with 1st class bricks in cement mortar (1:4) In foundation & plinth
Brick work with 1st class bricks in cement mortar (1:4) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] 1:3 ,20 mm thick plaster
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 4mm thick clear glass. For window
Supplying, fitting and fixing windows and ventilators with or with out integrated grills conforming to IS1038-1975 and manufactured from rolled steel sections conforming to IS7452-1974with non-friction projecting type,box type hinges,glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete(1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Open able steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only.
M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S.flats and bars.
M.S.gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting,bolting,welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.
Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface :two coats.
Applying decorative cement based paint of approved quality afterpreparing the surface including scraping the same thoroughly(plastered or concrete surface) as per manufacturer's specification.
Neat cement punningabout 1.5mmthick inwall, dado,window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m
Supplying and Drawing 1.1KV single core stranded 'FR' PVCi nsulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following size sinthe pre laid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm).
Distribution wiringin 1.1KV grade 2x22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) insuitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated &unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch(Anchormake) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment andmending good damages to building works[PVC casing-capping on surface and Switch board concealed]Average rum 5m.
total item 1 to 4.24
18% GST on item 5
total item 5 and 6
1% cess on item 7
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.42 MB
Tendernotice_2.pdf
PDF • 0.56 MB
Tendernotice_3.pdf
PDF • 0.11 MB
Tendernotice_4.pdf
PDF • 0.36 MB
Tendernotice_5.pdf
PDF • 0.29 MB
Tendernotice_6.pdf
PDF • 0.36 MB
Tendernotice_7.pdf
PDF • 0.36 MB
NIET07202526.pdf
Tender Documents • 1.41 MB
BOQ_2459685.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid