Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹42.1 L+₹1.3 L (3.30%)Rejected-Finance MAJUMDER COLONY BURDWAN ROAD SILIGURI DIST DARJEELING WB PIN 734 014 | DARJEELING | WEST BENGAL | 734014 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹45.2 L+₹4.4 L (10.9%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹46.7 L+₹5.9 L (14.6%)Rejected-Finance 35 PATHAK PARA ROAD FLAT NO 32C 3RD FLOOR SHANTINEER APARTMENT BEHALA KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹47.3 L+₹6.6 L (16.1%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BENGDUBI
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
GE/BENG/39 OF 2021-22 SPECIAL REPAIR TO ROOF OF OFFRS MESS AND PROVN OF SHED FOR STORING CONSV MECHANICAL/EQUIPMENT 03 X PORTABLE WATER PUMP FOR SWT AND MINOR WORKS AT CERTAIN UNITS UNDER AGE B/R I AND AGE E/M OF GE BENGDUBI MIL STN
2021_MES_474373_5
GE/BENG/39 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE BENGDUBI
MES Enlisted/ Un-enlisted contractor of Class D and above with category a(i)
8 documents required · 8 mandatory
₹500
GE BENGDUBI
₹76,000
Yes
25 Feb 2022
4 Feb 2022
18 Feb 2022
4 Feb 2022
16 Feb 2022
11 Feb 2022
60 days
Amount
SCHEDULE 'A' (B/R Works)
Dismantling of plain or corrugated steel sheets any gauge, thickness including Nanital or similar pattern in roof coverings including ridges, hips and valley gutter all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F roof trusses (farmed), trusses purlins, crane gantries, rails and fastenings and heavy bracket framing MS tubes medium grade as in truss, purlin, rafters, post etc fixed with and including angle cleat , MS plate etc including necessary welding, fittings etc Fe-410-W (Gde-E-250 quality-A) complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F Pre-painted coloured trapezoidal profiled galvalume/Zincalume sheet thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, Al Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as in roof covering/cladding to wall fixed with self tapping screws (12-14 x 55 with EPDM seals) complete all as specified and directed.
S&F Pre-painted coloured plain galvalume/Zincalume sheet thickness of 0.50 mm TCT confirming to IS-513 (AZ-150 GSM, Al Zn alloy mettalic coating with 550MPA yield stress as per AS-1397) as roof ridge fixed with self tapping screws (12-14 x 55 with EPDM seals), complete all as specified and directed.
S&F in repair PVC 200mm wide eves for roof sheet covering complete all as specified and as directed.
M&L for making good for wall top with cement mortor 1:6 for roof sheet complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation oards/slabs/ blankets, any thickness including cover fillets etc complete all as specified and directed.
S&F Anodised aluminium snap grid frame work size of grid 605mmx605mm for false ceiling and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified complete all as specified.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on false ceiling over a coat of pink primer preparation of new wooden surfaces of any description over 10cm width or girth and complete all as specified and as directed.
M&L for preparation of new surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additivews @ 1.46 litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10Sqm over new surfaces over 1mm thick wall care putty complete as specified and directed.
M&L for old walls washing, rubbing and stopping of distempered and painted surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 Gm/litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additivews @ 1.46 litre/10Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10Sqm over new surfaces over 1mm thick wall care putty complete as specified and directed.
M&L Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper white or any tint over 1mm thick wall care putty complete all as specified and directed.
Excavation in trenches not exc 1.50 mtr wide and not exc 1.5 mtr deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc and getting out in loose/soft soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance exc 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling & mass concrete complete all as specified and directed.
M&L for brick work with old size fly ash bricks with sub class 'B' built in CM 1:6 straight or curved on plan exc 6 m mean radius complete all as specified and directed.
M&L for Reinforced cement concrete M-25 (Design mix) using 20mm graded crushed stone aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete etc all as specified and directed.
M&L Reinforced cement concrete M-25 (Design mix) using 20 mm graded crushed stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L Reinforced cement concrete M-25 (Design mix) using 20 mm graded crushed stone aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Use & Waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surface of concrete complete all as specified and directed.
Use & Waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished surface of concrete complete all as specified and directed.
M&L for TMT bars (Fe-500/ Fe-550D) 10 mm dia & over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
All as per item No. 26.00 here-in-before but 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders complete all as specified and directed.
M&L for Rendering 15mm thickin two layers (10+5mm) externally on fair faces of brick or concrete surfaces in cement mortar 1:4 with water proofing compund in top layerof 5mm thick as per manufacurer's instructions, finished surfaces fair and smooth without using extra cement complete all as specified and directed. (Note: - WPC shall be measured and paid separately under relevent items.)
Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and as directed. (Pidiproof of Dr.fixit or equivalent)
M&L for Rendering 15 mm thick on other than fair faces of brick work or concrete surface in cement mortar (1:6) surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for sand filling under floor or in foundations in layes n. exc 25 cm thick including watering and consolidation all as specified and directed.
M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exc. 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protections, finished even and smooth without using extra cement with construction joints to be given every 3m interval 10 mm wide and in full depth at corners of building and filled with bituminious mastic mortar or equivalent filler complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in lintel upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, fixing of hold fast and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F steel windows with side hung shutter including projection type hinghs with steel handle, and steel pag stay, complete with glazing bars, dovetailed or welder all as specified.
S&F steel windows with side hung shutter including projection type hinghs with steel handle, and steel pag stay, complete without glazing bars, dovetailed or welder all as specified.
S&F galvanised mild steel wire cloth 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 4.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane complete all as specified and directed.
S&F 1.25mm thickness of laths Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and directed.
S&F mild steel safety lever lock with four levers (ISI Marked ) all as approved by Engineer-in-charge.
S&F ball bearing for rolling shutter complete all as specified and as directed.
M&L for 15-20mm thick machine cut kota stone slab in floors etc. over screed base laid and jointed with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed in cement mortar (1:6) complete all as specified and directed.
Ditto all as per item No 46.00 here-in-before but 15-20mm thick machine cut kota stone slab in skirting complete all as specified and directed.
SCHEDULE 'A' (E/M Works)
M&L for concealed point wiring One light point/one fan/light/exjaust/bell point controlled by one switch with FRLS PVC insulated unsheathed multistranded copper conductor cables 1100 Volts grade of 1.5 sqmm size alongwith one earth continuity conductor with FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade of 1.5 sqmm size through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for fixing of switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good to disturbed surface all as specified and directed.
All as per item No 47.00 here-in-before but One 3 pin socket outlet, 5 Amp on independent board all as specified and directed.
All as per item No 47.00 here-in-before but One 3 pin socket outlet, 5 Amp on same board all as specified and directed.
All as per item No 47.00 here-in-before but for one 15 Amp 3 pin switch socket outlet, independent with 2.5 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed.
S&F Switch piano, flush button type, single pole, one way 6 Amp, 230 volt complete all as specified and directed.
S&F switch socket outlet 5 pin 6 amp, 2 in 1 flush type all as specified and directed.
S&F switch socket outlet combination 2 in 1, 5 amp, flush piano universal type controlled by one switch conforming to IS complete all as specified and as directed.
S&F switch socket outlet combination 5 in 1, 5A/16A, flush piano universal type controlled by one switch conforming to IS complete all as specified and as directed.
S&F ceiling rose surface bakelite three terminals complete all as specified and as directed.
S&F ceiling fan regulator electronic stepping type and socket type, SP 230 Volts (2-Module) including necessary electric connection complete all as specified and directed.
S&F in replacement of LED Tube Light luminaries with high performance LED with driver 1 x 18W (4 Feet long, Cool day/Warm white) complete all as specified and directed . Make Havells cat part no. LUMILINEBS18WLED865SPWH OR EQUIVALENT MODEL OF CG /Philips.
S & F Building security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 32 mm GI bracket medium grade 1m long bent to shape including bolt, nut,washer,clam made out of MS flat of size 25X3mm, 4 nos Anchor Bolt of suitable size etc all as specified and as directed.
S&F ceiling fan of 1200 mm sweep BLDC Type, 230 V AC with accessories and connection with ceiling rose with MS hooke made out of ms flat iron size 25 X 5 mm for hanging of suitable length complete all as specified and as directed.
S&F Sheet metal enclosure for MCB, DBs, phosphatised, power coated, double door single pole & Neutral 12 way 240 volt with 200 Amps bus bar at incoming end complete all as specified and directed.
S&F MCB double pole 240 volts, 06 to 32 Amps, breaking capacity 10KA, 240 Volts 'C' curve all as specified and directed. Make:- Legrand /Havells/L&T/ ABB
S&F MCB single pole 240 volts, 06 to 32 Amps, breaking capacity 10KA, 240 Volts 'C' curve all as specified and directed. Make:- Legrand /Havells/L&T/ ABB
M&L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI marked with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trenches /poles/on wall complete including necessary cable glands, aluminium lugs duly crimped, termination etc all as specified and directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness complete all as specified and directed.
Supply & Laying Sub Class 'B' Bricks,old size, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion for UG cable protection complete all as specified and directed.
Material and labour for galvanized iron tubing 40 mm bore light grade with all fitting for protection of cable, laid in trenches / road cossing incl necessary clamp, bolt/nut if any all as specified and directed. (Note: Excavation, earth work shall be measured and paid separately)
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel, GI earth wire protected by 15mm bore light grade GI pipe and other end connected to earthing test point or main switch board as directed including funnel with watering pipe of 20mm bore light grade GI, wire mesh, charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode PCC (1:3:6) type C-1 earth pit, cast iron cover and frame, including necessary excavation and earth work and refilling of black soil good conductor of earth and necessary testing complete all as specified and directed and shown on electrical plate No 3 of MES Schedule Part-I complete all as specified and as directed.
Supply, install, testing & commissioning of hi wall, split-type Air Conditioner Unit of capacity 2.0 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with in-built air ionizer & plasma filter for better indoor air quality with minimum 5 star rated incl electric connection complete all as specified and as directed. NOTE : (i) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall of Non-CFC type & as per the latest technology. (ii) The cost of additional refrigerant pipes required (if any) is deemed to be included in the unit quoted rates. (iii) Suitable piping of adequate length & size 5/8" for drainage of condensate water from indoor unit shall be provided & the cost of the same is deemed to be included in the unit quoted rates. (iv) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates.
Supply, install, testing & commissioning of copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut out & time delay & of capacity 4.0 KVA incl electric connection complete all as specified and as directed.
M&L for sub main wiring with 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm alongwith one run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC conduit 25mm bore ISI marked complete all as specified and directed. Note :- (a) PVC Conduit shall be included in same rate. (b) For concealed sub-main wiring cutting chases shall be included in rate. (c) All the incomming and outgoing cable should be connected throgh proper lugs & sockets as per site requirement)
S&F single pole and neutral enclosure with a two pin and earth plug socket with double pole one MCB upto 20 Amp complete all as specified and directed.
Supply, Testing & Commissioning of portable fire pump compliance to IS -942 Specification with following Tech requirements included all spare parts like, Suction pipe, delivery hose, sitable T&P etc complete all as specified and directed. (Make: Kirloskar / KSB/ CG) Technical Specification (a) Model : MFP 275 D M (b) Make : Fire Fly fire pumps Pvt Ltd ror Equivalent. (c) Performance : 275 lpm @ 4.5 Bar : 100 lpm @ 5.0 Bar : 450 lpm @ 3.0 Bar : 500 lpm @ 1.0 Bar (d) Maximum Discharge: 500lpm (e) Maximum Pressure: 5.5 Bar (f) Fuel : Diesel (g) Engine: Lambardin/Kohler Make, Single Cylinder, 4 Stroke Diesel Engine (h) Engine Power : 9 HP at 36000 rpm (j) Fuel Tank Capacity: 5 Litre (k) Priming System : Exhaust Ejector Priming suction height upto 5.0 Meters (l) Suction : 75 mm (m) Delivery Outlet : 63 mm x 1 with screw down type valve (n) Typical Dimensins : L-570 x w-525 --560mm (o) Weight : 80 Kg (With Battery & Oil)
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 62800.00 (refer Tender Srl Page No 38). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
M/S P. RAI CHOUDHURY AND CO.
J T ENTERPRISE
MUKHERJEE ENTERPRISE
UNIVERSAL CONSTRUCTION
PRADIP KUMAR BOSE
Paritosh Saha
M/S K M CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .