Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹31.5 LAccepted-AOC | 1 | Accepted-AOC AOC | |
| 2 | 2₹35.7 L+₹4.2 L (13.3%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹35.8 L+₹4.3 L (13.8%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | 3 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
12 Jun 2021, 6:00 pmClosed
CWE LUCKNOW
229 MG ROAD LUCKNOW CANTT
PROVN OF SMART METERING SYSTEM AND AUTOMATION SYSTEM FOR STREET LIGHTS AT GAUR ENCLAVEUNDER GE (E/M) LUCKNOW
2021_MES_443148_1
CWE/LKO/EM/T-07 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
MES contractors enlisted in Class D and category b(i) and for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work and having executed similar nature of work
8 documents required · 8 mandatory
₹500
GE EM LUCKNOW
₹72,000
Yes
23 Jun 2021
15 May 2021
14 Jun 2021
15 May 2021
12 Jun 2021
31 May 2021
Amount
Taking down Old/unserviceable electric meter from site by disconnecting of all electric connections and deposited the same in MES store yard incl making good the disturbed surface of wall etc complete all as specified & directed.
Supply and Installation of IS16444 LPRF Single Phase Tamper proof Meter with the following specifications: • AC Single Phase , Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10-60 A conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Ratio Frequency (LPRF) communication facility in 865-867 MHz CyanConnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, monthly billing survey for Cumulative Energy and Max Demand • The meter would support both postpaid and prepaid funtionality and would have a connect / disconnect switch for the purpose complete all as specified & directed. MAKE: Secure, L&T, Schnieder
Supply and Installation of IP-67 protection Gateway compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Internet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network. complete all as specified & directed. Make: Secure, L&T, Schnieder, CyanConnode
Supply and fixing of 2 * 0.5 sq mm copper flexible cable including suitable flexible PVC pipe of dia 10 mm for providing power supply to the Main Meter Monitoring Unit complete all as specified & directed.
Supply and Configuration of the Web based Software per meter with following modules:- (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data complete all as specified & directed. (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. Contd......
(iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis.
(vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export The system would support export of metering and billing data in excel format.
(x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email. Make: Innologix, Schneider, Oracle Note: (a) The software would be hosted on MEITY (Ministry of Information Technology) approved GCC (Government Community Cloud) (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc.
Supply, Installation Testing & Commissioning of Meter Billing Computer each having the following specifications: Processor: INTEL i5 processor, RAM: 4 GB RAM, Hard Disk: 1TB and LAN port.Inbuilt softwares: Anti virus software, Web protection software, Restore software and Windows 7 pro or better, 21" Monitor and mouse (01 no.) - common for both complete all as specified & directed. Make of Computer: HP / IBM / DELL
Supply, Installation, Testing and Commissioning of 1.0 KVA UPS capable of providing 30 mins Power Backup complete all as specified & directed. Make: APC / Numeric / Luminous)
Supply, Installation, Testing and Commissioning of A4 size Laserjet printer complete all as specified & directed. Make: Canon / HP
One year comprehensive maintenance including operating costs . They would include the following items: (a) Monthly sim charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaise with the telecom service providers for necessary resolution. (b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes.
(d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work. (e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc. (f) Reports Development - The additional reports as needed for the success of the project would be developed (g) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required
Taking down carefully the old street light fittings 60 watt any type from the poles and refixing to use another location on poles after repair by replacement of unserviceable parts , complete all as specified and as directed. Note :- Replacement of the parts shall be measured & paid separately as supply only under respective item.
Supply only LED driver ( 35 V/45V/65V DC) suitable for LED street lights of 45 Watt, complete all as specified and as directed..
Supply & Fixing 6 Sqmm x3 core nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVCinsulated and PVC sheathed complete all as specified & directed.
Supply & fixing of multistep dimmable LED Street Light Single Piece Pressure Die Cast Aluminium Housing (LM6 Alloy)of high quality integrated LED Luminaire with a system lumen of 7200Lm and system wattage between 60W with an efficiency 120lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be top openable & of high quality pressure die cast aluminum LM6 Alloy with PF > 0.95 and THD < 10% & Surge Protection of 4KV. Input voltage of 140-270V. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (16-18 Hrs. per day) & OD suitable for 60mm, The Ingress protection should be minimum IP 66 with an IK rating of 07. The luminaire should have Integrated peanut optics to provide a high quality glare free lighting system The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. The LED used in the luminaire shall be SMD type only of make Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be compliant to CISPR 15 & IES 61547 (EMC, EMI compliant). The Driver should be potted /encapsulated & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The minimum length of the luminaire should be 400 mm and the width of the Luminaire should be more than 250mm ensuring a stable optical and thermal management. The weight of the luminaire should be 4.5 Kg. It should have a provision of 10KV series SPD.BIS approval for Both Driver and the luminaire needs to be submitted for records.. all as specified and directed.
Supply & Fixing commisioning of Feeder Panel for Remote Management, Switching and Monitoring of Street lights using Amp light control systems to be supplied with 5 year Software as a Service and Data Hosting Charges considering 1 feeder pillar cabinet for 40 Nos of LED streetlights.Feeder pillar should have Multi step dimming option for suitable fixture .Supply and installation of cabinet based group lighting management system. Lighting cabinets / feeder pillar to be connected independently to lighting management system server through a non proprietary and professional network such as G.P.R.S. / GSM with open internet providing with the following. (a) Automatic (with a timer), remote (with GPRS / GSM) and manual switching option. (b) Remote energy measurement (c) Near real time monitoring (d)Alarms and report generation (e) Emergency override - locally and remotely (f) Web based user interface with integrated visual maps (g) Data security and secured system access (h) Prevent unauthorised physical access to the street light control box (i)secured 128 BIT encrypted communication between serve and street light feeder panel.
M & L for One year comprehensive maintenance including operating costs . They would include the following items: (a) Monthly sim charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaise with the telecom service providers for necessary resolution. (b) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. Contd.......
(c) Software installation on any alternate / backup server if required (h) The communication network monitoring and support (i) Configuration of the repaired / replaced hardware in the system (j) Trouble shooting and necessary actions to run the system as required. (k) Software bug fixing as and when required
Unnati Engineers
FUTURE Inc.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .