Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹50.1 L+₹3.4 L (7.22%)Rejected-Finance KHAWASNIWAS NEAR POLICE QTRDEORALI GANGTOK SIKKIM | L2 | Rejected-Finance Higher Bid value. | |
| 3 | L3₹50.1 L+₹3.4 L (7.23%)Rejected-Finance | L3 | Rejected-Finance Higher Bid value. | |
| 4 | L4₹50.2 L+₹3.4 L (7.28%)Rejected-Finance | L4 | Rejected-Finance Higher Bid value. | |
| 5 | L5₹50.3 L+₹3.5 L (7.53%)Rejected-Finance | L5 | Rejected-Finance Higher Bid value. |
Tender Value
Refer Docs
EMD Value
₹82,600
Closing Date
7 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Gangtok
GE Gangtok New Mil Stn Gangtok, Sikkim PIN-737102
SPL REPAIR TO SEMI UNDERGROUND SUMP AT UPPER PENANGALA PROVN OF STAIRCASE FROM FOL DUMP TO DISH WASH POINT NEAR ORs MESS AT 617 EME BN AND COVERSHED IN FRONT OF BLDG NO P109 P109A OF NO I FID33 CISU UNDER GE GANGTOK
2023_MES_627540_1
8183/A/E8
Open Tender
Miscellaneous Works
Works
182 days
GE Gangtok New Mil Stn Gangtok
As per tender documents.
8 documents required · 8 mandatory
₹500
GE Gangtok
₹82,600
Yes
28 Dec 2023
8 Nov 2023
9 Dec 2023
9 Nov 2023
7 Dec 2023
16 Nov 2023
Amount
M&L for excavation over area in soft loose soil n. exc. 1.50m deep and getting out etc. copmlete all as specified.
Demolition of Reinforced Cement Concrete of any description and in any position.
M&L for demolation concrete in ground floores and pavings n. exc. 15 cm thickness below or above ground level.
M&L for cement concrete in steps etc. type C1 (1:3:6) 20mm graded stone aggt.
M&L for PCC 1:3:6 type C2 (using 40 mm grade stone aggregate), 75 mm thick as in plinth protection / approach path of bldg complete all as specified and directed by the Engr-in-Charge.
M&L for Cement concrete 40mm thick Type B1 (1:2:4) 20mm graded stone aggt in flooring
M&L for excavation in trenches n. exc. 1.5m wide and n. exc. 1.50m deepth for foundation, and getting out in soft loose soil etc. copmlete all as specified.
M&L for removing excaveted materials n. exc. 50m and depositing wherw directed at a level n. exc.1.5m above the starting point out etc. copmlete all as specified.
M&L for spreading and leveling in layers n. exc. 25cm thick and well ramming including watering as requiered.
M&L for cement concrete type D2 1:4:8 (40mm graded stone aggt) as in foundation etc. Complete all as specified.
M&L RCC M30 using 20mm graded stone aggr as in foundation, including rafts, footing, foundation beam, plinth beam, using liquid WPC complete all as specified and as directed. Note : liquid WPC measured and paid saperately in relevent items.
M&L RCC M30 using 20mm graded stone aggr as in wall, retaining wall, using liquid WPC complete all as specified and as directed. Note : liquid WPC measured and paid saperately in relevent items.
M&L RCC M30 using 20mm graded stone aggr as in slabs supported on walls beams and coulmns in floores, using liquid WPC complete all as specified and as directed. Note : liquid WPC measured and paid saperately in relevent items.
M&L RCC M30 using 20mm graded stone aggr as in beams, cantilevers etc., using liquid WPC complete all as specified and as directed. Note : liquid WPC measured and paid saperately in relevent items.
M&L for formwork to fair finish of sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work; vertical or to batter etc. complete
M & L for formwork to edges of concrete flats floors and etc. Exc. 5cm but n. exc. 10cm complete all as specified and as directed.
M & L for formwork to fair finish for faces of wall, retaining wall, staircase railing etc. complete all as specified and as directed.
M & L for formwork to fair finishes of soffits of suspended slabs such as roof slabs landing and similar slabs etc.
M&L TMT Bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip) completed.
M&L TMT Bars 5mm dia and over upto including 10mm fda cut to length bend to shape required including cranking bending spirally for column, hooking ends & binding with and including mild steel mild steel wire (annealed not less that 0.90 mm dia or securing with chip) completed.
M&L for 20 mm thick rendering in two layers 10 mm each in cement mortar (1:4) with using water proofing compound in external layer as per manufacturer instructions on fair faces of brick / concrete surfaces, top layer finishes even and smooth using extra cement complete all as specified and directed. Note : liquid WPC measured and paid saperately in relevent items.
M&L for precast cement concrete in cover slabs (for manholes) set in CM 1:4 type B1 1:2:4 (20mm graded stone aggt ) etc. all as specified and as directed.
Material & labour for PCC 1:3:6 type C2 (using 40 mm grade stone aggregate), 75 mm thick as in plinth protection / approach path of bldg complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:3:6, type C-2 as in Plum concrete in retaining walls etc. including plums of stone boulders (Basalt, trap or any other approved) of size 200 to 300mm complete all as specified and as directed. Ref TD Drg No SZ/TD/332/2015 Sheet No 1/1. Note : Boulders will be measured & paid in seperate item.
Supply only Boulders exceeding 20 cm and upto 30cm dia (Basalt, trap or any other approved) of size 200 to 300mm complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and as directed.
Material & labour for hardcore of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders.
Mild stell bar Fe 410 (Gde E250) quailty - or Fe 290E-165) 16mm dia as in rungs.
S&F cast iron vent pipe 75mm dia fix in concrete etc. all as specified ans as directed.
Supply only Liquid water proofing compound.
M&L for demolition & dismantling of concrete in ground floors and pavings n. exc. 15cm thickness (below or above ground level) etc. all as specified and as directed.
M&L for cutting hole 30 Cm depth and exc. 150 Sqcm but not exc. 400sq cm in stone walls built in cement mortar and walls of cement concrete and making goodin cement mortar 1:3 or cement concrerte 1:2:4 type B1 as requiered etc. all as specified and as directed.
M&L for excavation in post holes each n. exc. 0.5 Cum getting out & returning filling in soft loose soil and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm etc.
M&L for PCC 1:3:6 Type D2 40mm graded stone aggt as in foundation, etc. all as specified and as directed.
Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as in roof complete all as specified and directed by the Engr-in-Charge.
Supply and fix 0.50mm thick pre-painted galvalume aluminium zinc coating GI based plain steel sheets of any colour having tensile strength of 550 Mpa as in ridges, valley, eaves, etc. and fixed with self tapping screws complete all as specified and directed by the Engr-in-Charge.
M&L for mild steel rolled sections conforming to Fe - 290 (Gde E-165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including truss.
M&L for preparation of new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide completed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L for brushing neat cement slurrywith 3.0 Kg of cement per sqm.
M&L for 20mm thick screed bed in cement mortar (1:6) for laying floor finishes etc
M&L for lacquer coated coloured chequered cement conc tiles 300x300x25 mm thick set jointed and pointed in neat cement slurry in floores and steps and in vertical surfaces with greay cement and matching pigment over screed bed etc. all as specified and as directed.
M&L for returning filling in, including spereading, levelling, watering and well ramming in layers not exc. 25 cm. etc. all as specified and as directed.
M&L for RR uncoursed well bonded beded and solidly hearted built in 1:6 CM all as specified.
M&L for providing, type B1 1:2:4 20mm graded stone aggt in cement concrete in steps, coping kerbs or mud stops, rounded or chamfered on edges etc all as specified and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, in soft loose soil complete all as specified and directed by the Engr-in-Charge.
M&L for 15mm thick rendering 1:4 CM on fair faces to receive tile etc all as specified and as directed.
S/F 75mm bore PVC pipe (SWR) single socketed, in any length with rubber ring joints, as in weep holes complete all as specified and directed.
S/F of geosynthetic materials 75 mm dia as in weep holes cover as directed.
Dismantling and taking out old unserviceable rusted GI water mains and removal complete all as specified and as directed by Engineer-in-Charge :-
40mm dia bore
50mm dia bore
S&F GI tubing medium grade ISI marked laid in trenches / laid under floor on ground / floor including all fittings such as elbow, union, reducer, tees, bends etc. and short length complete all as specified and as directed by Engineer-in-Charge for the following sizes :-
40mm dia bore
50mm dia bore
S&F in replacement gun metal gate valves of size 40mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed.
S&F in replacement gun metal gate valves of size 50mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed.
S&F Bends, tapers, tee pieces (single & double branch) any type and angle / radius and straight connecting pieces but all ends flanged complete all as specified and as directed by Engineer-in-Charge.
Excavation trenches n. exc. 1.5m wide and n. exc. 1.50m depth for laying / repairs to pipe line and getting out in any soft loose soil all as specified and directed by Engineer-in-Charge.
Returning and filling in excavated soil including spreading, levelling, watering and well ramming in layers n. exc. 25cm.
Removing surplus excavated soil not exceeding 50m and depositing where directed at level not exceeding 1.5m above starting point.
M&L for PCC type D2 (1:4:8) using 40mm graded stone aggregates as in supporting pillar / block including necessry form wrok as required complete for resting GI pipes.
M&L for submain wiring alongwith earth wire of size 3 x 4.0 Sqmm with PVC insulated unsheathed single core stranded copper conductor (FRLS) cable of working voltage 1100 volts grade conforming to IS-694 Part-I & II of 2000 drawn in and including 25mm size PVC rigid non metallic casing caping (double lock) with all casing capping fittings & accessories with PVC gang box including 4 Sqmm PVC insulated unsheathed single core stranded copper conductor (FRLS) cable as earth continuity conductor connected to earth dolly complete all as specified and directed. Note : Three runs of PVC wire wirh one run of PVC casing and caping will be measured and paid........
S&F switch socket combination, 2 in 1, 6 pin, 5/6 Amps and 15/16 Amps, multipurpose, flush, non shutter, non inter locking type, 230 volt flush type, white / ivory finish with two fixing hole including suitable gang box complete all as directed.
S&F double door MCB DB SPN 4 way horizontal type for outgoing made out of steel sheet phosphatised power painted, neutral link, earth bar din rail.
Supply, install, testing & commissioning of electric water heater in repairs, storage vertical type, 5 star rated, 25 ltr capacity comprising of high wattage heating element for instant heating, extra thick inner tank of superior grade, rust & shock proof ABS ourter body, non-ferrous pressure plate with & including provn of 04 Nos grouting bolts suitably flushed to wall or any other surface including water & electric connection with 3 core PVC insulated, sheathed, stranded copper conductor cable / flexible chord complete all as specified and as directed.
S&F MCB single pole, 6 to 32 Amps, 240 Volts, 10 KA rapturing capacity c curve complete all as directed by Engineer-in-Charge.
S&F MCB SPN 40 Amps, 240 Volts, 10 KA rapturing capacity c curve complete all as directed by Engineer-in-Charge.
M/S S. S CHETTRI AND SONS
KAMLESH ENTERPRISE
KARMA SHERPA
DHARMINDER SINGH
SANJAY KAUSHIK
BIJAY MITTAL
KARMA TSETEN BHUTIA
MAHENDRA KHAWAS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .