Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical not fulfilling all NIT conditions |
Tender Value
₹46.3 L
EMD Value
₹92,650
Closing Date
26 Mar 2024, 3:00 pmClosed
Assistant General Manager EM
Food Corporation of India Zonal Office North Zone Plot A 2A A 2B Sector 24 Noida
Renovation and upgradation of Electrical Installations including Wiring and LED lighting arrangement in FCI ZO North Building Noida UP
2024_FCI_801154_1
EM/2023-24/03
Open Tender
Electrical Works
Works
120 days
FCI Zonal Office North Noida
As per MTF
12 documents required · 12 mandatory
₹0
₹92,650
Yes
3 May 2024
16 Mar 2024
27 Mar 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
Amount
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A Switch
15/16 A Switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings) (Confoming to relevant BIS/IS standard or equivalent).
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Confoming to relevant BIS/IS standard or equivalent)
1 or 2 module (75mmx75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required (Confoming to relevant BIS/IS standard or equivalent).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSHR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLSHR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate etc. as required.
Supply, Installation, Testing and Commissioning of 100W LED Flood Light with IP66 Protection, Pressure Die Cast Aluminium Housing (LM6/ADC12) , System Lumen Output of >120 Lm/W, THD<10%, CRI >70, CCT 5700K ANSI BIN, Driver should be constant current Asphalt based fully potted driver Rated IP66, Operating Voltage 120V - 270V, Heat Resistance PC Diffuser min IK07Driver shall have the feature of 325V±10V and 440V sustain upto 8 hrs, Driver shall have Surge Protection 5 KV inbuilt in the driver and 10KV Addtional insdie the driver compartment, LED Source >50000 Burning Hours @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number) (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply, Installation, Testing and Commissioning of 10W LED Bulk Head in PDC Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, Driver Isolated Type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, 100V Sustain upto 48 Hrs, Surge Protection 4KV, PMMA/PS Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number)(5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply, Installation, Testing and Commissioning of 36-40W LED Recess Panel (1'x4') in CRCA Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, Driver Isolated Type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, 100V Sustain upto 48 Hrs, Surge Protection 4KV, PMMA Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number) alongwith cutting the false ceiling and making good the same as required.(5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply of 18W to 20W LED Recess Panel (1'x1') in CRCA Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, 100V Sustain upto 48 Hrs, Surge Protection 2.5KV, PMMA Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number) alongwith cutting the false ceiling and making good the same as required. (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply of 18W to 20W LED Surface Panel (1'x1') in CRCA Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, Surge Protection 2.5KV, PMMA Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number). (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply of 36-40W LED Surface Panel (1'x4') in CRCA Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, Driver Isolated Type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, 100V Sustain upto 48 Hrs, Surge Protection 4KV, PMMA Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number). (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supply of 36-40W LED Recess Tile (2' X2') in CRCA Housing, System Lumen Output >120 Lm/W, LED Driver should be constant current type, THD<10%, CRI>80, CCT 5700 ANSI BIN, Operating Voltage 120V to 270V, 100V Sustain upto 48 Hrs, Surge Protection 4KV, PMMA Diffuser, LED Source >50000 Burning Hrs @L70, LM79 Report from In House NABL Lab is must and LM80 Report from LED Manufacturer, Luminaires & Driver shall have the BIS Certified (R- Number). (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. (with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8way (8+24), Double Door
12way (8+36), Double Door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc as required
100 A, 30KA, FPMCCB
Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing TPN 63 Amp, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air deliveryminimum 215 CMM, 380 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Minimum 5 years Manufacturer Warranty mandatory)
Supply of 300 mm Exhaust Fan , 1400 RPM motor, heavy duty, with steel body with all accessories suitable for single phase, AC 230 volts,50 Hz supply. (Minimum 2 years Manufacturer Warranty mandatory)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Earthing with G.I. earth pipe (B Class) 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) .
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 * 6 sq mm (19mm)
4 * 16 sq mm (28mm)
3.5 * 50 sq mm (35mm)
3.5 * 150 sq mm (50mm)
Installation, testing and commissioning of pre-wired, LED fitting of all types, complete with all accessories directly on ceiling/ wall, including connections with 3X1.5 sq. mm FRLSHR PVC insulated, copper conductor, single core cable and earthing etc. as required
Supplying and fixing SMC 1 phase Junction Box (with hinged door) on existing Pole/wall with provision for mounting 10 A SP MCB with Neutral Link and earth bolt , 415V AC, 50 Hz confirming to (Conforms to IS/IEC:60947-1 & 3) with suitable brass glands, thimbles , nuts and bolts including making connections and dismantling old boxes as required (240 * 130* 110 mm dimension) (Material supplied shall be batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/HUME/METAL pipe as required.
upto 35 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required.
upto 35 sq.mm (clamped with 1mm thick saddle)
Above 35 sq.mm and upto 95 sq.mm( clamped with 25x3mm MS Flat Clamp)
Above 95 sq.mm and upto 185 sq.mm( clamped with 25/40x3mm MS Flat Clamp)
Supply of Aluminium stranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Innersheathed for Multicore Cables , Armoured (galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 for following sizes ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material)
2 * 6 sq mm - Aluminium Armoured
4 * 16 sq mm - Aluminium Armoured
3.5 * 50 sq mm - Aluminium Armoured
3.5 * 150 sq mm - Aluminium Armoured
Dismantling Tile work in floors and roofs laid in Cement Mortar including Stacking material within 50 metres lead.
For thickness of tiles 10mm to 25mm
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material and disposal of unserviceable material within 50 metres lead.
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.
150 mm wide x 40 mm deep. ( 2 Partition)
200 mm wide x 40 mm deep. ( 2 Partition)
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification:
150 mm wide x 50 mm deep.
200mm wide x 50 mm deep
Supply of 400 mm wall Fan complete with double ball bearing, motor, blades, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required. (Minimum 2 years Manufacturer Warranty mandatory)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group 'C'
Providing and fixing M.V. danger notice plate of 200mm x 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250mm x 200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Dismantling of old switch sockets , recessed unservicable conduits ,MCB DBs, GI boxes , end boxes etc and making good the same complete etc. as required.
Credit for Dismantled Electrical items :
Iron Scrap - switch boxes, MCB DBs, GI scrap, Panel Scrap (except MCCBs, RCCBs and MCBs) etc., "AS IS WHERE IS BASIS"
Scrap Aluminium wiring and cables etc. "AS IS WHERE IS BASIS"
Old dismantled Twin (1' x 4') tube fitting etc. without Illuminor supply as required "AS IS WHERE IS BASIS"
Old dismantled (1' x 1') CFL fitting etc.as required "AS IS WHERE IS BASIS"
Old dismantled Ceiling Fan as required "AS IS WHERE IS BASIS"
Old dismantled Exhaust Fan as required "AS IS WHERE IS BASIS"
Old dismantled Wall Fan as required "AS IS WHERE IS BASIS"
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .